Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Clin Transl Res ; 7(1): 100-107, 2021 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-34104813

RESUMEN

BACKGROUND: Efficient neural processing of visuospatial and proprioceptive input appears to be crucial for avoidance of sport injury. As such, clinically-feasible tests are needed to identify deficiencies found by advanced neuroimaging and electrophysiological tests. Three-dimensional motion capture in a laboratory setting is currently the gold standard for measurement of human movement parameters but is costly and requires extensive training. Non-immersive virtual reality systems with body motion tracking, such as TRAZER, may provide a clinically-feasible and portable means of acquiring similar variables. Test-retest reliability and concurrent validity of these systems are currently lacking. AIM: The aim of the study was to assess the concurrent validity of the TRAZER single-camera system with 3D motion capture system and to assess the test-retest reliability of TRAZER's whole-body reactive agility metrics. METHODS: Participants - For validity, 13 healthy individuals (24.8±3.1 years, 170.0±7.7 cm, 70.0±14.2 kg); for reliability, 18 healthy individuals (23.3±2.5 years, 168.2±11.2 cm, 78.2±17.8 kg). Design - Validity was a single-session cross-sectional study. Reliability was a 3 consecutive day test-retest study. Setting-Controlled laboratory study. Intervention - Assessments utilized randomized movements in eight directions for forty total repetitions as designated by the TRAZER system. TRAZER protocol was simultaneously tracked by Vicon Motion Capture and the TRAZER system. Reliability data were captured on three consecutive days by the TRAZER system. Main Outcome Measures - Maximum acceleration, maximum velocity, and total distance were recorded for validation. In addition to these measures, maximum deceleration, average velocity, average acceleration, average deceleration, and average reaction time were collected for reliability. RESULTS: Overall, a lack of agreement exists between maximum outputs for TRAZER and 3D motion capture (velocity r=0.808, acceleration r=-0.090), but total distance correlation was high (r =.961). ICC values between days 1-2-3 for average measures were high (average velocity=0.847, average acceleration=0.919, and average deceleration=0.948) with the exception of average reaction time being fair (ICC=0.536). ICCs for maximum measures showed a much smaller correlation between days (velocity=0.654, acceleration=0.171, and deceleration=0.416). CONCLUSIONS: Even though there is a lack of strong concurrent validity between measures obtained from TRAZER and 3D motion capture systems, there is strong test-retest reliability of the TRAZER system. The applicability of these findings makes TRAZER clinically relevant in scenarios requiring pre- and post-testing for return to play decisions, or monitoring of a training regimen where demonstration of validation to a gold standard measurement is not relevant. RELEVANCE FOR PATIENTS: When test-retest capability is desired, such as in return-to-play protocols following an injury, Trazer is a reliable option.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...