Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Anal Toxicol ; 47(3): 287-298, 2023 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-36542823

RESUMEN

Benzodiazepines and z-hypnotics are detected in the majority of fatal overdose cases in Norway, often in combination with other drugs of abuse, and their concentrations in peripheral blood (PB) might be important to elucidate the cause of death. In some forensic autopsies, PB is however not available. The aim of the present study was to compare concentrations of benzodiazepines and z-hypnotics in five alternative matrices to assess whether these concentrations are comparable to concentrations in PB. A total of 109 forensic autopsy cases were included. PB, cardiac blood (CB), pericardial fluid (PF), psoas muscle (PM), lateral vastus muscle (LVM) and vitreous humor (VH) from each case were analyzed using ultra high performance liquid chromatography--tandem mass spectrometry. We were able to detect clonazepam, 7-aminoclonazepam, flunitrazepam, 7-aminoflunitrazepam, nitrazepam, 7-aminonitrazepam, diazepam, nordiazepam, oxazepam, alprazolam, midazolam, zopiclone and zolpidem in all the analyzed matrices. Concentrations measured in VH were generally much lower than those of PB for all compounds except zopiclone. 7-Amino metabolite concentrations were high compared to the parent compounds, although less so for the muscle samples. Concentrations of the parent nitrobenzodiazepines in muscles were higher than those in PB, but for the other compounds, concentrations in muscle showed good correspondence with PB. Both CB and PF were viable alternative matrices for PB, although a larger variation and a tendency for higher concentrations in PF were observed. This study shows that CB, PM, LVM and PF can give comparable concentrations to PB for benzodiazepines and z-hypnotics, while VH was less suitable. The concentrations in alternative matrices must, however, be interpreted carefully.


Asunto(s)
Benzodiazepinas , Hipnóticos y Sedantes , Autopsia , Compuestos de Azabiciclo
2.
Scand J Public Health ; 51(1): 21-27, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34538164

RESUMEN

BACKGROUND: People who inject drugs (PWID) have a high risk of premature death due to fatal overdoses. Newly emerged fentanyls, much more potent than heroin and other opioids, may increase this risk further. Therefore, precise information on injected drugs is critical to improving prevention strategies. AIMS: This study aimed to analyse drug residues in used injection equipment in order to determine drug and drug combinations and compare and complement findings with self-reported information. METHODS: Used syringes and needles (n=766) were collected at the supervised drug consumption facilities, the needle exchange service and two low-threshold health services for problem drug users in Oslo, Norway. The material was collected every third month from June 2019 to June 2020 and analysed for 64 substances using highly specific analytical methods (ultra-high performance liquid chromatography tandem mass spectrometry). Additionally, a street-recruited sample of PWID was interviewed from 2017 to 2019 regarding their drug injection habits (n=572). RESULTS: Heroin (65.5%) or amphetamines (59.8%), often in combination (30.5%), were commonly detected in drug residues. Other opioids, stimulants or benzodiazepines were rarely detected (6.1%). Fentanyl was detected in only one syringe. Heroin was the most reported drug (77.6% during the past four weeks, 48.3% daily/almost daily), followed by amphetamines (57.5% during the past four weeks, 23.1% daily or almost daily). Injection of methadone, buprenorphine and dissolved tablets was self-reported more frequently than determined in drug residue findings. CONCLUSIONS: Analysis of the injection equipment proved useful as a non-invasive, rapid and accurate means to obtain detailed information on injected drugs in Oslo and supplement traditional PWID survey information.


Asunto(s)
Residuos de Medicamentos , Drogas Ilícitas , Abuso de Sustancias por Vía Intravenosa , Humanos , Drogas Ilícitas/análisis , Abuso de Sustancias por Vía Intravenosa/epidemiología , Residuos de Medicamentos/análisis , Heroína/análisis , Autoinforme
3.
Forensic Sci Int ; 329: 111082, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34775328

RESUMEN

Cannabis is the most widely used illicit substance worldwide. A limited number of studies have investigated whether tetrahydrocannabinol (THC) and cannabidiol (CBD) can be detected in other postmortem matrices than blood and urine. The aim of this study was to investigate the distribution of THC and CBD in several different postmortem matrices. Concentrations in peripheral blood were compared to those in cardiac blood, pericardial fluid, psoas muscle, vastus lateralis muscle, and vitreous humor. A total of 39 postmortem forensic autopsy cases were included. THC and CBD were analyzed using gas chromatography-mass spectrometry. We were able to detect both THC and CBD in most of the analyzed matrices. For vitreous humor, however, only approximately 50% of the cases were available for analysis, and only two were found to be positive. Median concentrations in peripheral blood were 0.0040 (0.00042-0.056) mg/L for THC and 0.0013 (0-0.023) mg/L for CBD. The concentration ratios between pericardial fluid and cardiac blood compared to peripheral blood were< 1 for both THC and CBD for the majority of the cases. For THC, a median ratio of 0.60 (0.063-7.2) and 0.65 (0.068-4.8) were found for pericardial fluid and cardiac blood, respectively, compared to peripheral blood, whereas for CBD the corresponding median ratios were 0.40 (0.010-1.9) and 0.80 (0.017-2.4). The THC concentrations in psoas muscle and vastus lateralis muscle were high compared to those in peripheral blood in several cases, and large variations in the muscles to peripheral blood concentration ratios were seen. This was also the case for CBD. Our study shows that THC and CBD can be detected in postmortem matrices other than peripheral blood, and results from other matrices might provide important information in forensic cases where peripheral blood is not available. However, vitreous humor was not suitable for detecting neither THC nor CBD.


Asunto(s)
Cannabidiol , Cannabis , Detección de Abuso de Sustancias , Autopsia , Dronabinol
4.
Addiction ; 116(11): 3104-3112, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33739552

RESUMEN

AIMS: To study whether the preparation procedure, and its acidic and heating conditions, used by heroin users to prepare heroin for intravenous administration affects the final composition of the fluid to be injected. METHODS: Samples from different seizures of illegal heroin provided by the Norwegian police were prepared by adding water and ascorbic acid before heating under controlled conditions in the laboratory. Further, three seizures were prepared with different amounts of ascorbic or citric acid relative to their diacetylmorphine content. Pure diacetylmorphine base or salt was also submitted to the procedure applying two different heating intensities. The seizures and the final product after preparation were analysed for diacetylmorphine, 6-acetylmorphine and morphine using liquid chromatography with tandem mass spectrometry (LC-MS-MS). RESULTS: After preparation, a decrease of 19.8% (25th and 75th percentiles = -29.2 and -15.3) in the initial diacetylmorphine content was observed. Both the 6-acetylmorphine and morphine content increased but, due to their low content in the initial product, diacetylmorphine still represented 83.9% (25th and 75th percentiles = 77.3 and 88.0) of the sum of these three opioids in the final solution. The loss of water during preparation caused an increase in the concentration of diacetylmorphine, 6-acetylmorphine and morphine, depending on the heating intensity applied. The content of these opioids was affected by the quantity and type of acid added in relation to the heroin purity and the level of diacetylmorphine dissolved being proportional to the amount of ascorbic acid, but not citric acid, in the sample with high heroin purity. CONCLUSIONS: Preparation of heroin for intravenous injection appears to change the amount or concentration of diacetylmorphine and its active metabolites, 6-acetylmorphine and morphine in the final product, depending on heroin purity, amount and type of acid used or heating conditions. These circumstances can contribute to unintentional variations in the potency of the final injected solution, and therefore affect the outcome after injection.


Asunto(s)
Heroína , Laboratorios , Administración Intravenosa , Humanos , Proyectos de Investigación
5.
Acta Vet Scand ; 62(1): 30, 2020 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-32546243

RESUMEN

BACKGROUND: Exposure to anticoagulant rodenticides (ARs) in dogs is among the most common causes of poisoning in small animal practice, but information about toxicokinetic of these rodenticides in dogs is lacking. We analysed blood and faeces from five accidentally exposed dogs and 110 healthy dogs by reversed phase ultra-high performance liquid chromatography-tandem mass spectrometry. The aim of the study was to estimate elimination of brodifacoum, bromadiolone and difenacoum after acute exposure, calculate the half-lives of these rodenticides in dogs, estimate faecal elimination in a litter of puppies born, and further to identify the extent of AR exposure in a healthy dog population. RESULTS: Three dogs were included after single ingestions of brodifacoum; two dogs ingested bromadiolone and one dog ingested difenacoum. Maximum concentrations in faeces were found after day 2-3 for all ARs. The distribution half-lives were 1-10 days for brodifacoum, 1-2 days for bromadiolone and 10 days for difenacoum. Brodifacoum and difenacoum had estimated terminal half-lives of 200-330 days and 190 days, respectively. In contrast, bromadiolone had an estimated terminal half-life of 30 days. No clinical signs of poisoning or coagulopathy were observed in terminal elimination period. In blood, the terminal half-life of brodifacoum was estimated to 8 days. Faeces from a litter of puppies born from one of the poisoned dogs were examined, and measurable concentrations of brodifacoum were detected in all samples for at least 28 days after parturition. A cross-sectional study of 110 healthy domestic dogs was performed to estimate ARs exposure in a dog population. Difenacoum was detected in faeces of one dog. Blood and faecal samples from the remaining dogs were negative for all ARs. CONCLUSIONS: Based on the limited pharmacokinetic data from these dogs, our results suggest that ARs have a biphasic elimination in faeces using a two-compartment elimination kinetics model. We have shown that faecal analysis is suitable and reliable for the assessment of ARs exposure in dogs and a tool for estimating the AR half-lives. Half-lives of ARs could be a valuable indicator in the exposed dogs and provides important information for veterinarians monitoring AR exposure and assessment of treatment length in dogs.


Asunto(s)
Anticoagulantes/farmacocinética , Perros/metabolismo , Rodenticidas/farmacocinética , 4-Hidroxicumarinas/sangre , 4-Hidroxicumarinas/metabolismo , 4-Hidroxicumarinas/farmacocinética , Animales , Anticoagulantes/sangre , Anticoagulantes/metabolismo , Cromatografía Líquida de Alta Presión/veterinaria , Perros/sangre , Heces/química , Espectrometría de Masas/veterinaria , Rodenticidas/sangre , Rodenticidas/metabolismo
6.
J Anal Toxicol ; 42(7): 446-458, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-29762694

RESUMEN

Peripheral blood (PB) is considered to be the golden standard for measuring postmortem drug concentrations. In several cases, PB is however not available, but information regarding drug findings might still be crucial in order to determine the cause of death. Antidepressants are frequently detected in postmortem samples from forensic toxicology cases, but the literature investigating concentrations in other matrices than peripheral and heart blood is limited.We here describe a study for comparison of concentrations for a large number of different drugs in six different matrices. A total of 173 postmortem cases were included in the study material. The results from 44 cases with findings of antidepressants (amitriptyline/nortriptyline, citalopram, mianserin, mirtazapine, paroxetine, sertraline, trimipramine and venlafaxine) are presented in this article. Concentrations in peripheral and cardiac blood (CB), pericardial fluid (PF), two muscle samples and vitreous humour (VH) are compared. Ratios between concentrations in different matrices have also been compiled from available literature.All the investigated antidepressants were detected in all different matrices, and comparable concentration levels were found in the different matrices with a few exceptions. Concentrations in VH were generally lower than in the other matrices, and in a few cases with low concentrations in blood the antidepressants were not detected in VH. For most of the cases, ratios of 0.5-2 were found between concentration in PB and that in the other matrices. Some deviant concentrations where however found.This study shows that CB, PF, muscle and VH can provide important indications of the corresponding concentrations in PB when PB is not available.


Asunto(s)
Antidepresivos/análisis , Músculo Esquelético/química , Líquido Pericárdico/química , Cuerpo Vítreo/química , Antidepresivos/sangre , Autopsia , Toxicología Forense/métodos , Humanos , Cambios Post Mortem , Detección de Abuso de Sustancias/métodos
7.
J Anal Toxicol ; 42(5): 311-320, 2018 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-29409037

RESUMEN

In some forensic autopsies blood is not available, and other matrices are sampled for toxicological analysis. The aims of the present study were to examine whether heroin metabolites can be detected in different post-mortem matrices, and investigate whether analyses in other matrices can give useful information about concentrations in peripheral blood. Effects of ethanol on the metabolism and distribution of heroin metabolites were also investigated. We included 45 forensic autopsies where morphine was detected in peripheral blood, concomitantly with 6-acetylmorphine (6-AM) detected in any matrix. Samples were collected from peripheral blood, cardiac blood, pericardial fluid, psoas muscle, lateral vastus muscle, vitreous humor and urine. Opioid analysis included 6-AM, morphine, codeine, and morphine glucuronides. The 6-AM was most often detected in urine (n = 39) and vitreous humor (n = 38). The median morphine concentration ratio relative to peripheral blood was 1.3 (range 0-3.6) for cardiac blood, 1.4 (range 0.07-5.3) for pericardial fluid, 1.2 (range 0-19.2) for psoas muscle, 1.1 (range 0-1.7) for lateral vastus muscle and 0.4 (range 0.2-3.2) for vitreous humor. The number of 6-AM positive cases was significantly higher (P = 0.03) in the ethanol positive group (n = 6; 86%) compared to the ethanol negative group (n = 14; 37%) in peripheral blood. The distribution of heroin metabolites to the different matrices was not significantly different between the ethanol positive and the ethanol negative group. This study shows that toxicological analyses of several matrices could be useful in heroin-related deaths. Urine and vitreous humor are superior for detection of 6-AM, while concentrations of morphine could be assessed from peripheral or cardiac blood, pericardial fluid, psoas muscle and lateral vastus muscle.


Asunto(s)
Consumo de Bebidas Alcohólicas/metabolismo , Toxicología Forense/métodos , Heroína/análogos & derivados , Derivados de la Morfina/análisis , Morfina/análisis , Trastornos Relacionados con Opioides/metabolismo , Detección de Abuso de Sustancias/métodos , Consumo de Bebidas Alcohólicas/sangre , Consumo de Bebidas Alcohólicas/orina , Cadáver , Codeína/análisis , Codeína/sangre , Codeína/orina , Glucurónidos/análisis , Glucurónidos/sangre , Glucurónidos/orina , Heroína/análisis , Heroína/sangre , Heroína/orina , Humanos , Morfina/sangre , Morfina/orina , Derivados de la Morfina/sangre , Derivados de la Morfina/orina , Narcóticos/análisis , Narcóticos/sangre , Narcóticos/química , Narcóticos/orina , Noruega , Trastornos Relacionados con Opioides/sangre , Trastornos Relacionados con Opioides/orina , Líquido Pericárdico/química , Músculos Psoas/química , Músculo Cuádriceps/química , Distribución Tisular , Toxicocinética , Cuerpo Vítreo/química
8.
J Forensic Sci ; 63(3): 911-914, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-28810070

RESUMEN

Zolpidem is a sedative that could be used to drug victims, but its suitability to dissolve in drinks is unknown. In this small study, we added either crushed or whole tablets of zolpidem hemitartrate to carbonated beverages or still water to observe how this affected the taste and appearance. Also, concentrations were measured by ultra-high performance liquid chromatography tandem mass spectrometry at different time intervals. Two crushed tablets (20 mg) in cider (250 mL) lead to a maximum concentration of 84 mg/L zolpidem base after 30 min, while the corresponding concentration after adding fifteen tablets (150 mg) was 467 mg/L. There was little change in taste, but froth and turbidity were observed when adding high doses to carbonated beverages. Carbonated beverages spiked with 20 mg of crushed zolpidem hemitartrate tablets reached concentrations that could cause impairment. Spiking with 150 mg could possibly be lethal if several mouthfuls were ingested.


Asunto(s)
Bebidas Gaseosas , Agua Potable , Hipnóticos y Sedantes/análisis , Piridinas/análisis , Gusto , Cromatografía Líquida de Alta Presión , Humanos , Hipnóticos y Sedantes/química , Piridinas/química , Espectrometría de Masas en Tándem , Zolpidem
9.
Forensic Sci Int ; 276: 12-17, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28463706

RESUMEN

BACKGROUND AND AIMS: Several publications have suggested increasing cannabis potency over the last decade, which, together with lower amounts of cannabidiol (CBD), could contribute to an increase in adverse effects after cannabis smoking. Naturalistic studies on tetrahydrocannabinol (THC) and CBD in blood samples are, however, missing. This study aimed to investigate the relationship between THC- and CBD concentrations in blood samples among cannabis users, and to compare cannabinoid concentrations with the outcome of a clinical test of impairment (CTI) and between traffic accidents and non-accident driving under the influence of drugs (DUID)-cases. Assessment of THC- and CBD contents in cannabis seizures was also included. METHODS: THC- and CBD concentrations in blood samples from subjects apprehended in Norway from April 2013-April 2015 were included (n=6134). A CTI result was compared with analytical findings in cases where only THC and/or CBD were detected (n=705). THC- and CBD content was measured in 41 cannabis seizures. RESULTS: Among THC-positive blood samples, 76% also tested positive for CBD. There was a strong correlation between THC- and CBD concentrations in blood samples (Pearson's r=0.714, p<0.0005). Subjects judged as impaired by a CTI had significantly higher THC- (p<0.001) and CBD (p=0.008) concentrations compared with not impaired subjects, but after multivariate analyses, impairment could only be related to THC concentration (p=0.004). Analyzing seizures revealed THC/CBD ratios of 2:1 for hashish and 200:1 for marijuana. CONCLUSIONS: More than ¾ of the blood samples testing positive for THC, among subjects apprehended in Norway, also tested positive for CBD, suggesting frequent consumption of high CBD cannabis products. The simultaneous presence of CBD in blood does, however, not appear to affect THC-induced impairment on a CTI. Seizure sample analysis did not reveal high potency cannabis products, and while CBD content appeared high in hashish, it was almost absent in marijuana.


Asunto(s)
Accidentes de Tránsito , Cannabidiol/sangre , Conducir bajo la Influencia , Dronabinol/sangre , Accidentes de Tránsito/legislación & jurisprudencia , Adulto , Conducir bajo la Influencia/legislación & jurisprudencia , Femenino , Humanos , Masculino , Abuso de Marihuana/sangre , Análisis Multivariante , Noruega
10.
Int J Legal Med ; 130(6): 1513-1518, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26966099

RESUMEN

A case of suspected drug-facilitated sexual assault, involving codeine and acetaminophen, possibly mixed in beer, was recently addressed at the Norwegian Institute of Public Health. To examine the case, a small study was performed, spiking beer with preparations containing codeine and acetaminophen and observing the concentrations, appearance, and taste of the solutions. The study revealed the majority of the preparations to be quickly soluble in beer, achieving high concentrations, but at the expense of strong taste and drastic visible changes in the beer.


Asunto(s)
Cerveza/análisis , Codeína/análisis , Narcóticos/análisis , Detección de Abuso de Sustancias , Acetaminofén/análisis , Analgésicos no Narcóticos/análisis , Codeína/efectos adversos , Color , Crimen , Toxicología Forense , Humanos , Narcóticos/efectos adversos , Violación , Solubilidad , Gusto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...