Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Asunto principal
Intervalo de año de publicación
1.
Orthop J Sports Med ; 11(8): 23259671231192134, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37576454

RESUMEN

Background: Few studies have examined the short-term clinical outcomes of rotator cuff repair (RCR) with all-suture anchors for medial row anchor fixation. Purpose: To evaluate clinical outcomes of double-row suture bridge RCR using a novel all-suture medial row anchor. Study Design: Case series; Level of evidence, 4. Methods: We enrolled 179 patients before double-row suture bridge RCR (mean age at surgery, 60.0 years; 63% male patients) at a single institution. All patients underwent RCR with all-suture anchor fixation for the medial row and solid anchor fixation for the lateral row. Preoperative (baseline) and follow-up (minimum follow-up time of 2 years; mean, 2.5 years) clinical outcomes were compared using the American Shoulder and Elbow Surgeons (ASES) score and a 10-point numeric pain rating scale (NPRS). We calculated the proportions of patients meeting previously published Patient Acceptable Symptom State (PASS) thresholds for the ASES (≥78.0) and NPRS (≤1.7). We further compared baseline and follow-up outcome scores and the proportions of patients meeting PASS thresholds using paired t tests and McNemar tests, respectively, and calculated effect size to quantify the magnitude of change from baseline to follow-up. Results: Values significantly improved from baseline to follow-up for ASES (from 45.3 ± 19.8 to 87.3 ± 17.1) and NPRS (from 5.2 ± 2.5 to 1.4 ± 2.1). The proportion of patients meeting PASS thresholds also significantly improved for the ASES (from 6% to 77%) and the NPRS (from 7% to 72%). The magnitude of baseline to follow-up change for all measures was large (all effect sizes ≥1.5). Conclusion: Our study demonstrated excellent short-term clinical outcomes and substantial improvements for patients undergoing double-row suture bridge RCR with all-suture anchors for medial row fixation.

2.
J Clin Densitom ; 25(4): 668-673, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36180332

RESUMEN

INTRODUCTION: While prior studies have generally reported rigorous protocols using prespecified CT scanner settings for HU measurements, the present study sought to report on the correlation between DXA and HUs recorded using several CT scanners with varying sequences, simulating measurements performed in "real-world" hospital and Emergency Department (ED) settings. METHODOLOGY: Six raters performed HU measurements of trabecular bone at the L1 vertebral body for forty consecutive patients on Phillips and General Electric (GE) abdominal CT scans obtained between 2017 and 2021. Inter-rater reliability of the HU measurements and their correlations with recorded DXA-based bone assessments were determined. Correlation coefficients were calculated for the HU measurements between scanner vendors as well as for the CT HUs with each DXA measurement. RESULTS: The ICC for L1 HUs read on the Phillips and GE scanners were 0.85 and 0.82, respectively, indicating excellent agreement. The correlation coefficient for the mean HUs on the Phillips and GE scanners was 0.92, also indicating excellent correlation. For both scanner vendors, the HU values most closely correlated with the total femur and femoral neck T-scores. CONCLUSIONS: HU values recorded on a Phillips and GE scanner both demonstrated excellent inter-rater reliability. Correlations were strongest between L1 HU values and total femur DXA T-scores. Readily available abdominal CT image data across multiple hospital settings can be utilized by providers of varying level of imaging interpretation expertise to determine vertebral body Hounsfield units that may help identify osteoporosis risk without additional radiation exposure or cost.


Asunto(s)
Osteoporosis , Humanos , Absorciometría de Fotón/métodos , Osteoporosis/diagnóstico por imagen , Densidad Ósea , Reproducibilidad de los Resultados , Vértebras Lumbares/diagnóstico por imagen , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...