Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Crohns Colitis ; 13(11): 1372-1379, 2019 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-30944925

RESUMEN

BACKGROUND AND AIMS: Several factors have been reported to affect faecal calprotectin [FC] values, and significant variation in FC concentrations has been observed in inflammatory bowel disease [IBD] patients. We aimed to evaluate FC variability in IBD patients, and to assess the robustness of a single stool punch. METHODS: This is a single-centre observational case-control study. Disease activity was assessed using endoscopic and clinical activity scores, as well as C-reactive protein levels. Stool samples were collected twice within a 1 to 6 days interval, and FC was measured on punches and homogenates by fluorometric enzyme immunocapture assay. RESULTS: In all, 260 stool samples were collected from 120 patients. Intrastool variability was low, with an intraclass correlation coefficient for single measures between three punches from a single stool sample of 0.91, and median coefficient of variation [CV] of 17%. CV of two stool samples a few days apart [intra-individual variability] were significantly higher [p <0.01] with median CV of 36%. FC standard deviations correlated with mean FC levels either for intrastool or for intra-individual variability, with a Spearman's coefficient of rank correlation of 0.85 and 0.78, respectively [p <0.01]. Disease type, location, activity, and FC levels did not influence variability. CONCLUSIONS: A single stool punch is reliable for FC measurement, considering that intrastool variability is low. Intra-individual variability a few days apart is significantly higher. Therefore, decision-making strategies based on single measurements should consider this variability, to determine the minimum optimal variation to be achieved, rather than a cut-off, especially in high FC levels.


Asunto(s)
Heces/química , Enfermedades Inflamatorias del Intestino/metabolismo , Complejo de Antígeno L1 de Leucocito/análisis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/análisis , Proteína C-Reactiva/análisis , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Manejo de Especímenes , Adulto Joven
2.
Clin Chem Lab Med ; 56(9): 1498-1506, 2018 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-29729138

RESUMEN

BACKGROUND: The measurement of complement components is clinically useful where a deficiency is suspected, or where excessive activation and consumption are present in disease. C2 deficiency carries an increased risk of developing systemic lupus erythematosus, recurrent infections and atherosclerosis. In this study, we have evaluated The Binding Site's Human Complement C2 SPAPLUS® assay. METHODS: Linearity was tested using 13 sample dilutions covering the standard measuring range. Within- and between-assay variabilities were calculated using five samples with different C2 concentrations. The correlation between C2 concentrations in EDTA-plasma and serum was assessed, as was the correlation between C2 measurements by the automated assay and radial immunodiffusion. C2 concentrations were compared with CH50 activity, and quantified in individuals with homozygous or heterozygous C2 deficiency, acquired angioedema and patients with chronic inflammatory conditions. RESULTS: The assay was linear across the measuring range (3.8-42.3 mg/L). Intra- and interassay variability were 2.3%-3.8% and 0%-3.3%, respectively. Comparison between C2 measurements in EDTA-plasma and serum provided a strong correlation (p<0.0001, R2=0.82, slope 0.92), as did the correlation between the automated and radial immunodiffusion methods (p<0.0001, R2=0.89, slope 1.07). A positive correlation between C2 concentration and CH50 activity was demonstrated (p<0.0001, R2=0.48). Significant differences were observed between the median C2 concentrations obtained in healthy controls and the patient clinical samples, with homozygous C2-deficient patients giving below detectable results. CONCLUSIONS: This C2 SPAPLUS® assay allows the automated, rapid and precice quantification of complement C2 protein and could therefore be considered as a replacement for older, more time-consuming methods.


Asunto(s)
Complemento C2/análisis , Inmunoturbidimetría/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Angioedema/patología , Angioedemas Hereditarios/patología , Automatización , Complemento C2/normas , Femenino , Humanos , Inmunoturbidimetría/normas , Lupus Eritematoso Sistémico/patología , Masculino , Persona de Mediana Edad , Valores de Referencia , Adulto Joven
3.
Clin Biochem ; 46(1-2): 79-84, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23041246

RESUMEN

OBJECTIVES: Preliminary results of the IgA Hevylite™ assay including the establishment of the 95% reference interval and assessment of the specificity and sensitivity in different populations are reported. DESIGN AND METHODS: The concentrations of IgA heavy and light chains (HLC) enabling to determine an IgAκ/IgAλ ratio were quantified in 119 apparently healthy individuals to generate 95% reference intervals. The specificity of this assay was assessed in 48 patients with an isolated polyclonal IgA increase. In a retrospective analysis of 68 patients with a monoclonal component type IgA (MC-IgA) identified by serum immunofixation (IFE), IgA HLC ratio values were compared with known results for serum protein electrophoresis (SPE) and free light chain (FLC) ratios. RESULTS: The 95% reference range obtained in 119 controls (0.91-2.04) was close to that quoted by the manufacturer (0.80-2.04). Eight of the 48 patients (16.7%) with a polyclonal IgA increase had an IgA HLC ratio above the upper limit of the 95% reference interval. The IgA HLC ratio identified 65 (95.6%) among 68 patients with MC-IgA identified on the basis of IFE. For 34 of these patients (50%), MC-IgA was not detected by SPE due to its co-migration with alpha-2 or beta-globulins. CONCLUSIONS: Compared with serum IFE, the IgA HLC ratio has a sensitivity of 95.6%. Further studies are needed to assess the specificity of the IgA HLC ratio in patients with an isolated polyclonal increase of serum IgA.


Asunto(s)
Inmunoglobulina A/sangre , Cadenas Pesadas de Inmunoglobulina/sangre , Cadenas Ligeras de Inmunoglobulina/sangre , Paraproteinemias/sangre , Paraproteinemias/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Electroforesis de las Proteínas Sanguíneas/métodos , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Control de Calidad , Valores de Referencia , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
4.
J Immunol Methods ; 276(1-2): 69-77, 2003 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-12738360

RESUMEN

There is a need for simple and sensitive assays to assess innate and adaptive immune responses to microbial agents and vaccines. Herein, we describe a whole blood method allowing to measure the induction of cytokine synthesis at the mRNA level. The originality of this method consists in the combination of PAXgene tubes containing an mRNA stabilizer for blood collection, the MagNA Pure instrument as an automated system for mRNA extraction and RT-PCR reagent mix preparation, and the real-time PCR methodology on the Lightcycler for accurate and reproducible quantification of transcript levels. We first demonstrated that this method is adequate to measure the induction of interleukin (IL)-1beta and IL-1 receptor antagonist (IL-1 RA) mRNA upon the addition of bacterial lipopolysaccharide (LPS) to whole blood. We then showed that this approach is also suitable to detect the production of mRNA encoding T cell-derived cytokines in whole blood incubated with tetanus toxoid as a model of in vitro immune response to a recall antigen. Finally, we demonstrated that this methodology can be used successfully to assess inflammatory as well as T cell responses in vivo, as it allowed to detect the induction of IL-1beta and IL-1 RA after injection of LPS in healthy volunteers, and also the induction of IL-2 upon recall immunisation with tetanus vaccine.


Asunto(s)
Citocinas/sangre , ARN Mensajero/sangre , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Adulto , Citocinas/genética , Humanos , Inyecciones Intravenosas , Proteína Antagonista del Receptor de Interleucina 1 , Interleucina-1/sangre , Interleucina-1/genética , Cinética , Lipopolisacáridos/administración & dosificación , Lipopolisacáridos/farmacología , Masculino , Monitorización Inmunológica/métodos , Sialoglicoproteínas/sangre , Sialoglicoproteínas/genética , Linfocitos T/inmunología , Toxoide Tetánico/inmunología , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...