Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Diabetes Technol Ther ; 26(4): 263-275, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38194227

RESUMEN

Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC) that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing. Specifically, it is proposed that at least 7.5% of comparator BG concentrations are <70 mg/dL (3.9 mmol/L) and >300 mg/dL (16.7 mmol/L), respectively, and that at least 7.5% of BG-RoC combinations indicate fast BG changes with impending hypo- or hyperglycemia, respectively. These proposed characteristics of the comparator data can facilitate the harmonization of testing conditions across different studies and CGM systems and ensure that the most relevant scenarios representing real-life situations are established during performance testing. In addition, a study protocol and testing procedure for the manipulation of glucose levels are suggested that enable the collection of comparator data with these characteristics. This work is an important step toward establishing a future standard for the performance evaluation of CGM systems.


Asunto(s)
Glucemia , Hiperglucemia , Humanos , Automonitorización de la Glucosa Sanguínea/métodos , Monitoreo Continuo de Glucosa , Hiperglucemia/diagnóstico , Hiperglucemia/prevención & control
3.
J Diabetes Sci Technol ; 17(1): 107-116, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-34486426

RESUMEN

BACKGROUND: Providing real-time magnitude and direction of glucose rate-of-change (ROC) via trend arrows represents one of the major strengths of continuous glucose monitoring (CGM) sensors in managing type 1 diabetes (T1D). Several literature methods were proposed to adjust the standard formula (SF) used for insulin bolus calculation by accounting for glucose ROC, but each of them provides different suggestions, making it difficult to understand which should be applied in practice. This work aims at performing an extensive in-silico assessment of their performance and safety. METHODS: The methods of Buckingham (BU), Scheiner (SC), Pettus/Edelman (PE), Klonoff/Kerr (KL), Aleppo/Laffel (AL), Ziegler (ZI), and Bruttomesso (BR) were evaluated using the UVa/Padova T1D simulator, in single-meal scenarios, where ROC and glucose at mealtime varied between [-2,+2] mg/dL/min and [80,200] mg/dL, respectively. Efficacy of postprandial glucose control was quantitatively assessed by time in, above and below range (TIR, TAR, and TBR, respectively). RESULTS: For negative ROCs, all methods proved to increase TIR and decrease TAR and TBR vs SF, with KL, PE, and BR being the most effective. For positive ROCs, a general worsening of the performances is present, only BR improved the glycemic control when mealtime glucose was close to hypoglycemia, while SC resulted the safest in the other conditions. CONCLUSIONS: Insulin bolus adjustment methods are effective for negative ROCs, but they generally appear to overdose for positive ROCs, calling for safer strategies in such a scenario. These results can be useful in outlining guidelines to identify which adjustment to apply based on the mealtime condition.


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico
4.
Diabetologia ; 66(1): 3-22, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36198829

RESUMEN

A technological solution for the management of diabetes in people who require intensive insulin therapy has been sought for decades. The last 10 years have seen substantial growth in devices that can be integrated into clinical care. Driven by the availability of reliable systems for continuous glucose monitoring, we have entered an era in which insulin delivery through insulin pumps can be modulated based on sensor glucose data. Over the past few years, regulatory approval of the first automated insulin delivery (AID) systems has been granted, and these systems have been adopted into clinical care. Additionally, a community of people living with type 1 diabetes has created its own systems using a do-it-yourself approach by using products commercialised for independent use. With several AID systems in development, some of which are anticipated to be granted regulatory approval in the near future, the joint Diabetes Technology Working Group of the European Association for the Study of Diabetes and the American Diabetes Association has created this consensus report. We provide a review of the current landscape of AID systems, with a particular focus on their safety. We conclude with a series of recommended targeted actions. This is the fourth in a series of reports issued by this working group. The working group was jointly commissioned by the executives of both organisations to write the first statement on insulin pumps, which was published in 2015. The original authoring group was comprised by three nominated members of the American Diabetes Association and three nominated members of the European Association for the Study of Diabetes. Additional authors have been added to the group to increase diversity and range of expertise. Each organisation has provided a similar internal review process for each manuscript prior to submission for editorial review by the two journals. Harmonisation of editorial and substantial modifications has occurred at both levels. The members of the group have selected the subject of each statement and submitted the selection to both organisations for confirmation.


Asunto(s)
Diabetes Mellitus , Insulina , Humanos , Estados Unidos , Insulina/uso terapéutico , Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus/tratamiento farmacológico , Tecnología
5.
Diabetes Care ; 45(12): 3058-3074, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36202061

RESUMEN

A technological solution for the management of diabetes in people who require intensive insulin therapy has been sought for decades. The last 10 years have seen substantial growth in devices that can be integrated into clinical care. Driven by the availability of reliable systems for continuous glucose monitoring, we have entered an era in which insulin delivery through insulin pumps can be modulated based on sensor glucose data. Over the past few years, regulatory approval of the first automated insulin delivery (AID) systems has been granted, and these systems have been adopted into clinical care. Additionally, a community of people living with type 1 diabetes has created its own systems using a do-it-yourself approach by using products commercialized for independent use. With several AID systems in development, some of which are anticipated to be granted regulatory approval in the near future, the joint Diabetes Technology Working Group of the European Association for the Study of Diabetes and the American Diabetes Association has created this consensus report. We provide a review of the current landscape of AID systems, with a particular focus on their safety. We conclude with a series of recommended targeted actions. This is the fourth in a series of reports issued by this working group. The working group was jointly commissioned by the executives of both organizations to write the first statement on insulin pumps, which was published in 2015. The original authoring group was comprised by three nominated members of the American Diabetes Association and three nominated members of the European Association for the Study of Diabetes. Additional authors have been added to the group to increase diversity and range of expertise. Each organization has provided a similar internal review process for each manuscript prior to submission for editorial review by the two journals. Harmonization of editorial and substantial modifications has occurred at both levels. The members of the group have selected the subject of each statement and submitted the selection to both organizations for confirmation.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Humanos , Insulina/uso terapéutico , Automonitorización de la Glucosa Sanguínea , Consenso , Glucemia , Sistemas de Infusión de Insulina , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Insulina Regular Humana/uso terapéutico , Glucosa/uso terapéutico , Tecnología , Hipoglucemiantes/uso terapéutico
6.
Acta Diabetol ; 59(7): 921-928, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35416537

RESUMEN

AIM: Whether glucose sensor alarms improve metabolic control and are accepted by individuals with diabetes is unclear. Here, we investigated whether switching from a standard flash glucose monitoring system (FGM1) to a system equipped with hypo- and hyperglycemia alarms (FGM2) improves glycemic control and psychological outcomes in adults with type 1 diabetes (T1D). METHODS: Subjects with T1D and > 4% of time in hypoglycemia or > 40% of time in hyperglycemia were studied while wearing FGM1 (4 weeks) and after switching to FGM2 for 8 weeks. The primary endpoint was the change in time in range (TIR 70-180 mg/dl [3.9-10.0 mmol/L]) after 4 weeks of FGM2 use. Time below range (TBR), time above range (TAR), mean glucose, coefficient of variation (CV), sensor scans, treatment satisfaction, and hypoglycemia fear were secondary outcomes. RESULTS: We included 38 subjects aged 33.7 ± 12.6 year. During 4 weeks of FGM2 use, TIR increased from 52.8 to 57.0% (p = 0.001), TBR decreased from 6.2 to 3.4% (p < 0.0001) as did time < 54 mg/dl (from 1.4 to 0.3%, p < 0.0001) and CV (from 39.6% to 36.1%, p < 0.0001). These changes were confirmed after 8 weeks of FGM2 use. Treatment satisfaction improved and fear of hypoglycemia decreased. Subjects who had > 4% of time in hypoglycemia at baseline showed the greatest improvements in glucose control and treatment satisfaction. CONCLUSION: Switching from FGM1 to FGM2 improved TIR and treatment satisfaction and reduced fear of hypoglycemia. Participants who benefited most from switching from FGM1 to FGM2 were those prone to hypoglycemia.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hiperglucemia , Hipoglucemia , Adulto , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/complicaciones , Humanos , Hiperglucemia/complicaciones , Hiperglucemia/prevención & control , Hipoglucemia/complicaciones , Hipoglucemiantes/uso terapéutico , Insulina
7.
Diabetes Res Clin Pract ; 185: 109784, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35183648

RESUMEN

AIMS: Automated insulin delivery improves glucose control. Aim of this study was to compare in real life the effects on glucose control and patient reported outcomes of an advanced hybrid closed loop system (Control-IQ), versus a simpler system with predictive low glucose suspend function (Basal-IQ). METHODS: Thirty-one type 1 diabetic subjects were studied during Basal-IQ and after switching to Control-IQ. Variables analyzed were time spent in range (70-180 mg/dL), in tight range (70-140 mg/dL), above range (>180 mg/dL), below range (<70 mg/dL), mean glucose, coefficient of variation and glycated hemoglobin. Questionnaires were administered regarding therapy satisfaction (Diabetes Treatment Satisfaction Questionnaire in status/change form), fear of hypoglycemia (Hypoglycemia Fear Survey), quality of sleep (Pittsburgh Sleep Quality Index). RESULTS: After 12 weeks of Control-IQ, time in range increased from 62.7 to 74.0%, p < 0.0001, time in tight range increased from 37.1 to 44.6 %, p < 0.001, time above range decreased from 35.6 to 24.4% p < 0.0001. Improvements were observed in mean glucose and glucose variability. Glycated hemoglobin decreased from 7.0% (53 mmol/mol) to 6.6% (49 mmol/mol), p < 0.0001. Subjects using Control-IQ manifested greater satisfaction and less fear of hypoglycemia. CONCLUSION: Compared to Basal-IQ, Control-IQ improves glucose control and therapy satisfaction.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucosa/uso terapéutico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Medición de Resultados Informados por el Paciente
8.
J Diabetes Sci Technol ; 16(6): 1555-1559, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-34218721

RESUMEN

We present a new mobile platform to be used in clinical trials aimed at both collecting data and assessing new technologies and treatments for diabetes care. The main components of the platform are a mobile app, that automatically collects data from continuous glucose monitoring sensors and activity trackers, and also allows users to manually log daily events; a cloud database for safe data storage; a web interface, which allows clinicians to monitor patients' status in real-time. The platform is modular and highly customizable for a multitude of purposes in clinical research. Preliminary tests performed for daily-life data gathering by both clinicians and users are extremely encouraging.


Asunto(s)
Diabetes Mellitus , Aplicaciones Móviles , Humanos , Automonitorización de la Glucosa Sanguínea , Glucemia , Monitoreo Fisiológico , Recolección de Datos
9.
Diabetes Obes Metab ; 24(3): 522-529, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34866293

RESUMEN

AIMS: To conduct a pooled analysis to assess the performance of intermittently scanned continuous glucose monitoring (isCGM) in association with the rate of change in sensor glucose in a cohort of children, adolescents, and adults with type 1 diabetes. MATERIAL AND METHODS: In this pooled analysis, isCGM system accuracy was assessed depending on the rate of change in sensor glucose. Clinical studies that have been investigating isCGM accuracy against blood glucose, accompanied with collection time points were included in this analysis. isCGM performance was assessed by means of median absolute relative difference (MedARD), Parkes error grid (PEG) and Bland-Altman plot analyses. RESULTS: Twelve studies comprising 311 participants were included, with a total of 15 837 paired measurements. The overall MedARD (interquartile range) was 12.7% (5.9-23.5) and MedARD differed significantly based on the rate of change in glucose (P < 0.001). An absolute difference of -22 mg/dL (-1.2 mmol/L) (95% limits of agreement [LoA] 60 mg/dL (3.3 mmol/L), -103 mg/dL (-5.7 mmol/L)) was found when glucose was rapidly increasing (isCGM glucose minus reference blood glucose), while a -32 mg/dL (1.8 mmol/L) (95% LoA 116 mg/dL (6.4 mmol/L), -51 mg/dL (-2.8 mmol/L)) absolute difference was observed in periods of rapidly decreasing glucose. CONCLUSIONS: The performance of isCGM was good when compared to reference blood glucose measurements. The rate of change in glucose for both increasing and decreasing glucose levels diminished isCGM performance, showing lower accuracy during high rates of glucose change.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Niño , Glucosa , Humanos
10.
Biomedicines ; 9(11)2021 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-34829952

RESUMEN

Patients with Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS) differ for triggers, mode of start, associated symptoms, evolution, and biochemical traits. Therefore, serious attempts are underway to partition them into subgroups useful for a personalized medicine approach to the disease. Here, we investigated clinical and biochemical traits in 40 ME/CFS patients and 40 sex- and age-matched healthy controls. Particularly, we analyzed serum levels of some cytokines, Fatty Acid Binding Protein 2 (FAPB-2), tryptophan, and some of its metabolites via serotonin and kynurenine. ME/CFS patients were heterogeneous for genetic background, trigger, start mode, symptoms, and evolution. ME/CFS patients had higher levels of IL-17A (p = 0.018), FABP-2 (p = 0.002), and 3-hydroxykynurenine (p = 0.037) and lower levels of kynurenine (p = 0.012) and serotonin (p = 0.045) than controls. Changes in kynurenine and 3-hydroxykynurenine were associated with increased kynurenic acid/kynurenine and 3-hydroxykynurenine/kynurenine ratios, indirect measures of kynurenine aminotransferases and kynurenine 3-monooxygenase enzymatic activities, respectively. No correlation was found among cytokines, FABP-2, and tryptophan metabolites, suggesting that inflammation, anomalies of the intestinal barrier, and changes of tryptophan metabolism may be independently associated with the pathogenesis of the disease. Interestingly, patients with the start of the disease after infection showed lower levels of kynurenine (p = 0.034) than those not starting after an infection. Changes in tryptophan metabolites and increased IL-17A levels in ME/CFS could both be compatible with anomalies in the sphere of energy metabolism. Overall, clinical traits together with serum biomarkers related to inflammation, intestine function, and tryptophan metabolism deserve to be further considered for the development of personalized medicine strategies for ME/CFS.

11.
Diabetes Obes Metab ; 23(8): 1892-1901, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33914401

RESUMEN

AIMS: To conduct a secondary analysis of the SAGE study to evaluate the association between glycaemic control and patient-reported outcomes (PROs), in adults with type 1 diabetes (T1DM) across different age groups and regions. MATERIALS AND METHODS: SAGE was a multinational, cross-sectional, observational study in adults with T1DM. Data were collected at a single visit, analysed according to predefined age groups (26-44, 45-64, and ≥65 years), and reported across different regions. PRO questionnaires were applied to assess hypoglycaemia fear (Hypoglycemia Fear Survey-II), diabetes-related distress (Problem Areas In Diabetes questionnaire), insulin treatment satisfaction (Insulin Treatment Satisfaction Questionnaire), and diabetes-specific quality of life (QoL; Audit of Diabetes-Dependent Quality of Life). Multivariable analysis was performed to evaluate the relationship between glycated haemoglobin (HbA1c) target achievement (<7% and individualised targets) with PRO scores. RESULTS: The PRO scores showed relatively low levels of diabetes-related emotional distress and fear of hypoglycaemia, moderate to high treatment satisfaction, and low diabetes-related impact on QoL. Results were generally comparable across age groups with some regional variability. Achievement of the HbA1c <7% target was associated with less worry about hypoglycaemia, lower diabetes-related emotional distress, higher insulin treatment satisfaction, and higher QoL. Achievement of individualised HbA1c targets was associated with lower diabetes-related emotional distress and higher insulin treatment satisfaction. CONCLUSIONS: Better glycaemic control was most closely associated with low emotional distress due to diabetes and high patient-reported insulin treatment satisfaction.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Anciano , Estudios Transversales , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Calidad de Vida
12.
Diabetes Ther ; 12(5): 1313-1324, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33725276

RESUMEN

INTRODUCTION: In persons with type 1 diabetes (T1D) insulin dosing can be adjusted based on trend arrows derived from continuous glucose monitoring (CGM). We propose a slide rule with narrower blood glucose intervals and more classes of insulin sensitivity than are available in current models. METHODS: The slide rule was tested in silico, in which a meal was simulated in 100 virtual subjects and the insulin bolus was calculated either in the standard way based on the insulin-to-carbohydrate ratio and the correction factor or according to the slide rule, following which the percentage time spent in range (70-180 mg/dl; %TIR), hypoglycemia (< 70 mg/dl; %THYPO), and hyperglycemia (> 180 mg/dl; %THYPER) was compared between the methods during the 4 h after the meal. Slide rule performance was also tested in real life by analyzing the same variables at during the 4 h postprandial period in 27 individuals with T1D. Only meals starting while the rate of change was at least 1 mg/dl per minute (increasing or decreasing) were considered for analysis. RESULTS: In silico, when the preprandial trend arrow was increasing, our slide rule reduced %THYPER and increased %TIR (p < 0.05), whereas when the preprandial trend arrow was decreasing, it reduced %THYPO and slightly increased %THYPER (p < 0.05). In real life, our slide rule kept subjects on target for 70.8 and 91.6% of postprandial time when preprandial trend arrows were increasing or decreasing, respectively. CONCLUSION: The proposed slide rule performed well both in silico and in real life, suggesting that it could be safely adopted by individuals with T1D to improve glucose control.

13.
Nutr Metab Cardiovasc Dis ; 31(2): 650-657, 2021 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-33594987

RESUMEN

BACKGROUND AND AIMS: Continuous glucose monitoring improves glycemic control in diabetes. This study compared the accuracy of the Dexcom G5 Mobile (Dexcom, San Diego, CA) transcutaneous sensor (DG5) and the first version of Eversense (Senseonics,Inc., Germantown, MD) implantable sensor (EVS). METHODS AND RESULTS: Subjects with type 1 diabetes (T1D) and using EVS wore simultaneously DG5 for seven days. At day 3, patients were admitted to a clinical research center (CRC) to receive breakfast with delayed and increased insulin bolus to induce glucose excursions. At CRC, venous glucose was monitored every 15 min (or 5 min during hypoglycemia) for 6 h by YSI 2300 STAT PLUS™ glucose and lactate analyzer. At home patients were requested to perform 4 fingerstick glucose measurements per day. Eleven patients (9 males, age 47.4 ± 11.3 years, M±SD) were enrolled. During home-stay the median [25th-75th percentile] absolute relative difference (ARD) over all CGM-fingerstick matched-pairs was 11.64% [5.38-20.65]% for the DG5 and 10.75% [5.15-19.74]% for the EVS (p-value = 0.58). At CRC, considering all the CGM-YSI matched-pairs, the DG5 showed overall smaller median ARD than EVS, 7.91% [4.14-14.30]% vs 11.4% [5.04-18.54]% (p-value<0.001). Considering accuracy during blood glucose swings, DG5 performed better than EVS when glucose rate-of-change was -0.5 to -1.5 mg/dL/min, with median ARD of 7.34% [3.71-12.76]% vs 13.59% [4.53-20.78]% (p-value<0.001), and for rate-of-change < -1.5 mg/dl/min, with median ARD of 5.23% [2.09-15.29]% vs 12.73% [4.14-20.82]% (p-value = 0.02). CONCLUSIONS: DG5 was more accurate than EVS at CRC, especially when glucose decreased. No differences were found at home.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/diagnóstico , Transductores , Tecnología Inalámbrica/instrumentación , Adulto , Biomarcadores/sangre , Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/terapia , Diseño de Equipo , Femenino , Control Glucémico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Resultado del Tratamiento
14.
Nutr Diabetes ; 11(1): 1, 2021 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-33414391

RESUMEN

BACKGROUND: Starting March 2020 the Italian Government imposed a lockdown to limit the spread of SARS-CoV-2. During lockdown outpatient visits were limited and telemedicine (TM) was encouraged. METHODS: We retrospectively analyzed data from continuous or flash glucose monitoring systems shared through different cloud systems during the lockdown by subjects with type 1 diabetes and compared data obtained 4 weeks before and 4 weeks after structured telephonic visit. Variables considered were mean glucose, time spent in target (70-180 mg/dl), hypoglycemia (<70 mg/dl) and hyperglycemia (>180 mg/dl), coefficient of variation, and length of sensor use. RESULTS: During the 4 weeks following the telephonic visit there was an improvement of glycemic control, with a significant reduction of mean glucose values (161.1 before vs 156.3 mg/dl after, p = 0.001), an increase of the time spent in target (63.6 vs 66.3, p = 0.0009) and a reduction of time spent in hyperglycemia (33.4 vs 30.5, p = 0.002). No changes were observed regarding glucose variability, time spent in hypoglycemia, and length of sensor use. Similar results were observed in subjects treated with multiple daily injections or continuous subcutaneous insulin infusion. CONCLUSIONS: A structured telephonic visit appears to be an effective way to replace or integrate routine visits in particular conditions.


Asunto(s)
COVID-19 , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Pandemias , Cuarentena , Telemedicina/tendencias , Adulto , Anciano , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Femenino , Control Glucémico , Humanos , Hiperglucemia/epidemiología , Hipoglucemia/epidemiología , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Italia/epidemiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
15.
Acta Diabetol ; 58(3): 355-362, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33098473

RESUMEN

BACKGROUND: Pregnant women with type 1 diabetes (T1D) have high risk of complications despite improved care based on technology advancements. OBJECTIVE: To assess the effects of pregnancy planning on fetal and maternal outcomes in T1D women treated with continuous subcutaneous insulin infusion (CSII). STUDY DESIGN: We retrospectively assessed maternal and neonatal outcomes in T1D women using CSII who had planned or unplanned pregnancies between 2002 and 2018. The study was done in two European countries with similar sustained programs for pregnancy planning over the study period. RESULTS: Data from 107 pregnancies and newborn babies were collected. Seventy-nine pregnancies (73.8%) had been planned. HbA1c was lower in planned versus unplanned pregnancy before and during all three trimesters of pregnancy (p < 0.0001). Pregnancy planning was associated with a reduction in the occurrence of iatrogenic preterm delivery (RR 0.44, 95% CI 0.23-0.95; p = 0.01). Risk reduction persisted after adjustments for mother's age above 40 years and preeclampsia. High HbA1c before or during pregnancy was associated with an increased risk of iatrogenic preterm delivery (RR 3.05, 95% CI 1.78-5.22, p < 0.0001). Premature newborns needed intensive care more often than those at term (RR 3.10, 95% CI 1.53-4.31; p = 0.002). CONCLUSIONS: Pregnancy planning in T1D women using CSII was associated with better glucose control and decreased risk of iatrogenic preterm delivery. Hence preconception care also improves pregnancy outcome in patients using an advanced mode of insulin delivery. Planned pregnancies could further benefit from the use of new metrics of glucose control.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Servicios de Planificación Familiar , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Resultado del Embarazo/epidemiología , Embarazo en Diabéticas/terapia , Adulto , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/epidemiología , Servicios de Planificación Familiar/métodos , Servicios de Planificación Familiar/estadística & datos numéricos , Femenino , Francia/epidemiología , Control Glucémico/estadística & datos numéricos , Humanos , Recién Nacido , Enfermedades del Recién Nacido/epidemiología , Italia/epidemiología , Masculino , Atención Preconceptiva/métodos , Atención Preconceptiva/normas , Atención Preconceptiva/estadística & datos numéricos , Embarazo , Embarazo en Diabéticas/sangre , Embarazo en Diabéticas/diagnóstico , Embarazo en Diabéticas/epidemiología , Embarazo no Planeado , Pronóstico , Estudios Retrospectivos
16.
Diabetes Ther ; 12(2): 509-525, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33351177

RESUMEN

INTRODUCTION: Following pivotal trials, real-world evidence is important to assess the impact of new drugs in everyday clinical practice. The RESTORE-1 study aimed to compare effectiveness and safety of the second-generation basal insulins (2BI), i.e., insulin glargine 300 U/ml (Gla-300) vs. degludec 100 U/ml (IDeg-100), in type 1 diabetes (T1D). METHODS: Retrospective, non-inferiority, multicenter study, based on electronic medical records. All patients switching to Gla-300 or IDeg-100 from first-generation basal insulins (1BI) were 1:1 propensity score matched (PSM). Changes during 6 months in HbA1c (primary endpoint), fasting plasma glucose (FPG), body weight, and insulin doses were assessed using linear mixed models for repeated measures. Incidence rates (IR) of hypoglycemic events were assessed. RESULTS: Overall, 19 centers provided data on 585 patients in each PSM cohort. For both groups, statistically significant reductions in HbA1c from baseline to 6 months were documented: - 0.20%; (95% CI - 0.32; - 0.08) in the Gla-300 group and - 0.14%; (95% CI - 0.24; - 0.04) in the IDeg-100 group. The non-inferiority of Gla-300 vs. IDeg-100 was confirmed (non-inferiority margin of 0.30%; upper 95% CI at 6 months, 0.09%). No statistically significant between-group differences emerged in FPG and body weight. Dose changes of basal and short-acting insulin were small in both groups, but higher in the Gla-300 group than in the Deg-100 group (p < 0.006). Incidence rates (IR) of hypoglycemia (blood glucose ≤ 70 mg/dl and < 54 mg/dl) during the 6-month follow-up by treatment were slightly lower in the Gla-300 group than in the Deg-100 group [IR ratios 0.82 (95% CI 0.55; 1.22) and 0.83; (95% CI 0.38; 1.83), respectively]. Hypoglycemic events (blood glucose < 54 mg/dl) decreased at 6 months in both groups (p = 0.01 for Gla-300 and p < 0.001 for IDeg-100). There were no severe hypoglycemic events for Gla-300 and seven events for IDeg-100 (p = 0.02). CONCLUSIONS: Switching from 1BI to 2BI in adults with T1D was associated with similar improvements in glycemic control and overall significant decrease in hypoglycemia, with no severe events with Gla-300. Effectiveness of both insulins was limited by under-titration.

17.
Nutr Metab Cardiovasc Dis ; 30(10): 1813-1819, 2020 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-32807633

RESUMEN

BACKGROUND AND AIMS: Premature cardiovascular disease cause excess mortality in type 1 diabetes (T1D). The Steno T1D Risk Engine was developed and validated in northern European countries but its validity in other populations is unknown. We evaluated the performance of the Steno T1D Risk Engine in Italian patients with T1D. MATERIALS AND METHODS: We included patients with T1D with a baseline visit between July 2013 and April 2014, who were free of cardiovascular disease and had complete information to estimate risk. The estimated cardiovascular risk score was compared with the 5-year rate of cardiovascular events by means of logistic regression. RESULTS: Among 223 patients (mean age 43 ± 13 years, 34.5% male, mean duration of diabetes 22 ± 12 years) the mean estimated cardiovascular risk at 5 years was 5.9% (95% C.I. 5.2-6.5%). At baseline, high estimated risk discriminated the presence of asymptomatic atherosclerosis better than microangiopathy, and was not associated with markers of inflammation or endothelial activation. After a mean follow-up of 4.7 ± 0.5 years, only 3 cardiovascular events were observed and nonetheless the risk score was significantly associated with their incidence (OR 1.22; 95% C.I. 1.08-1.39, p = 0.001). However, the observed event rate was significantly lower than the estimated one (3 vs 13; 95% C.I. 12-14; p < 0.001). CONCLUSION: The Steno T1D Risk Score identified subjects with subclinical atherosclerosis and high cardiovascular risk in an Italian T1D population. However, the absolute risk was significantly overestimated. Further studies in larger population are needed to confirm these results.


Asunto(s)
Enfermedades Cardiovasculares/epidemiología , Técnicas de Apoyo para la Decisión , Diabetes Mellitus Tipo 1/diagnóstico , Adulto , Enfermedades Cardiovasculares/diagnóstico , Diabetes Mellitus Tipo 1/epidemiología , Femenino , Humanos , Incidencia , Italia/epidemiología , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
18.
Nutr Metab Cardiovasc Dis ; 30(10): 1633-1644, 2020 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-32771260

RESUMEN

BACKGROUND AND AIM: Diabetic ketoacidosis (DKA) is a serious medical emergency once considered typical of type 1 diabetes (T1DM), but now reported to occur in type 2 and GDM patients as well. DKA can cause severe complications and even prove fatal. The aim of our study was to review recent international and national guidelines on diagnosis, clinical presentation and treatment of diabetic ketoacidosis, to provide practical clinical recommendations. METHODS AND RESULTS: Electronic databases (MEDLINE (via PUB Med), Scopus, Cochrane library were searched for relevant literature. Most international and national guidelines indicate the same accurate flow chart to diagnose, to evaluate from clinical and laboratory point of view, and treat diabetic ketoacidosis. CONCLUSION: Prompt diagnosis, rapid execution of laboratory analysis and correct treatment are imperative to reduce the mortality related to diabetic ketoacidosis. These recommendations are designed to help healthcare professionals reduce the frequency and burden of DKA.


Asunto(s)
Cetoacidosis Diabética/terapia , Endocrinología/normas , Consenso , Cetoacidosis Diabética/diagnóstico , Cetoacidosis Diabética/mortalidad , Técnicas de Diagnóstico Endocrino/normas , Humanos , Valor Predictivo de las Pruebas , Pronóstico , Factores de Riesgo
19.
Diabetes Ther ; 11(6): 1369-1379, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32395187

RESUMEN

INTRODUCTION: In late February 2020, due to the spread of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), the Italian Government closed down all educational and sport activities. In March, it introduced further measures to stop the spread of coronavirus disease (COVID-19), placing the country in a state of almost complete lockdown. We report the impact of these restrictions on glucose control among people with type 1 diabetes (T1D). METHODS: Data were collected on 33 individuals with T1D who were monitoring their glucose levels using a flash glucose monitoring device and remotely connected to the diabetes clinic on a cloud platform. We retrieved information on average glucose, standard deviation and percentage time in hypoglycaemia (< 70 mg/dl), glucose range (70-180 mg/dl) and hyperglycaemia (> 180 mg/dl). We compared glycaemic measures collected during lockdown to those collected before the SARS-CoV-2 epidemic and to the periods immediately before lockdown. RESULTS: In 20 patients who had stopped working and were at home as a result of the lockdown, overall glycaemic control improved during the first 7 days of the lockdown as compared to the weeks before the spread of SARS-CoV-2. Average glucose declined from 177 ± 45 mg/dl (week before lockdown) to 160 ± 40 mg/dl (lockdown; p = 0.005) and the standard deviation improved significantly. Time in range increased from 54.4 to 65.2% (p = 0.010), and time in hyperglycaemia decreased from 42.3 to 31.6% (p = 0.016). The number of scans per day remained unchanged. In 13 patients who continued working, none of the measures of glycaemic control changed during lockdown. CONCLUSION: Despite the limited possibility to exercise and the incumbent psychologic stress, glycaemic control improved in patients with T1D who stopped working during the lockdown, suggesting that slowing down routine daily activities can have beneficial effects on T1D management, at least in the short term.

20.
N Engl J Med ; 381(18): 1774-1775, 2019 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-31618534
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...