Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Ann Am Thorac Soc ; 21(5): 814-822, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38330168

RESUMEN

Rationale: Oral appliances are second-line treatments after continuous positive airway pressure for obstructive sleep apnea (OSA) management. However, the need for oral appliance titration limits their use as a result of monitoring challenges to assess the treatment effect on OSA. Objectives: To assess the validity of mandibular jaw movement (MJM) automated analysis compared with polysomnography (PSG) and polygraphy (PG) in evaluating the effect of oral appliance treatment and the effectiveness of MJM monitoring for oral appliance titration at home in patients with OSA. Methods: This observational, prospective study included 135 patients with OSA eligible for oral appliance therapy. The primary outcome was the apnea-hypopnea index (AHI), measured through in-laboratory PSG/PG and MJM-based technology. Additionally, MJM monitoring at home was conducted at regular intervals during the titration process. The agreement between PSG/PG and MJM automated analysis was revaluated using Bland-Altman analysis. Changes in AHI during the home-based oral appliance titration process were evaluated using a generalized linear mixed model and a generalized estimating equation model. Results: The automated MJM analysis demonstrated strong agreement with PG in assessing AHI at the end of titration, with a median bias of 0.24/h (limits of agreement, -11.2 to 12.8/h). The improvement of AHI from baseline in response to oral appliance treatment was consistent across three evaluation conditions: in-laboratory PG (-59.6%; 95% confidence interval, -59.8% to -59.5%), in-laboratory automated MJM analysis (-59.2%; -65.2% to -52.2%), and at-home automated MJM analysis (-59.7%; -67.4% to -50.2%). Conclusions: Incorporating MJM automated analysis into the oral appliance titration process has the potential to optimize oral appliance therapy outcomes for OSA.


Asunto(s)
Polisomnografía , Apnea Obstructiva del Sueño , Humanos , Apnea Obstructiva del Sueño/terapia , Apnea Obstructiva del Sueño/diagnóstico , Estudios Prospectivos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Mandíbula , Anciano , Presión de las Vías Aéreas Positiva Contínua/instrumentación , Presión de las Vías Aéreas Positiva Contínua/métodos , Movimiento , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación
2.
Sleep Sci ; 15(3): 318-325, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36158712

RESUMEN

Objective: In adults with sleep complaints, we assessed the software of automatic analysis of mandibular movements to identify sleep and wake states by confrontation with the polysomnography (PSG) and the actigraphy (ACTG). Material and Methods: Simultaneous and synchronized in-lab PSG, ACTG, and JAWAC were carried out in 100 patients with a sleep complaint. Epoch by epoch analysis was realized to assess the ability to sleep-wake distinction. Sleep parameters as measured by the three devices were compared. These included three regularly reported parameters: total sleep time (TST), sleep onset latency (SOL), and wake after sleep onset (WASO). Also, two supplementary parameters, wake during sleep period (WDSP) and latency to arising (LTA) were added to measure separately the quiet wakefulness states. Results: The epoch by epoch analysis showed that the JAWAC, as compared to ACTG, classified sleep and wake states with greater specificity, while the overall accuracy and sensitivity of the two devices were comparable. The sleep parameters analysis showed that for the JAWAC estimates, the differences in TST, SOL, and LTA values were not statistically significant. However, WDSP and subsequently WASO were slightly underestimated. In contrast, the dissimilarities between ACTG estimates and PSG measurements of all the above sleep parameters were statistically significant; TST was overestimated whilst SOL, LTA, WDSP, and WASO were underestimated. Conclusion: This study indicated that, besides its ability to reliably estimate TST, the JAWAC based on mandibular movements' analysis was able, in adults with sleep complaints, to overcome the important problem of the recognition of the state of quiet wakefulness.

4.
Korean J Orthod ; 50(6): 373-382, 2020 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-33144526

RESUMEN

OBJECTIVE: To compare computer-aided design and computer-aided manufacturing (CAD/CAM) customized nitinol retainers with standard stainlesssteel fixed retainers over a 12-month study period. METHODS: This randomized controlled trial (RCT) was conducted on 62 patients randomly allocated to a control group that received stainless-steel retainers or a test group that received customized CAD/CAM nickel-titanium retainers. Four time points were defined: retainer placement (T0) and 1-month (T1), 6-month (T2), and 12-month (T3) follow-up appointments. At each time point, Little's irregularity index (LII) (primary endpoint) and dental stability measurements such as intercanine width were recorded in addition to assessment of periodontal parameters. Radiological measurements such as the incisor mandibular plane angle (IMPA) were recorded at T0 and T3. Failure events (wire integrity or debonding) were assessed at each time point. RESULTS: From T0 to T3, LII and other dental measurements showed no significant differences between the two groups. The data for periodontal parameters remained stable over the study period, except for the gingival index, which was slightly, but significantly, higher in the test group at T3 (p = 0.039). The IMPA angle showed no intergroup difference. The two groups showed no significant difference in debonding events. CONCLUSIONS: This RCT conducted over a 12-month period demonstrated no significant difference between customized CAD/CAM nickel-titanium lingual retainers and standard stainlesssteel lingual retainers in terms of dental anterior stability and retainer survival. Both retainers eventually appeared to be equally effective in maintaining periodontal health.

5.
Eur J Orthod ; 42(6): 605-611, 2020 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-32006440

RESUMEN

OBJECTIVE: The aim of this trial was to test whether the use of a smartphone application (app) connected to a toothbrush improves the oral hygiene compliance of adolescent orthodontic patients. DESIGN: The study was designed as a multicentre, randomized, controlled clinical trial. SETTING: Two academic hospitals. ETHICAL APPROVAL: The study was approved by the ethics committee. SUBJECTS AND METHODS: This multicentre randomized controlled trial was conducted on 38 adolescents aged 12-18 years with full-fixed orthodontic appliances. Participants were randomly assigned either to a test group that used an interactive oscillating/rotating electric toothbrush connected to a brushing aid app or to a control group that used an oscillating/rotating electric toothbrush alone. At baseline, all patients received verbal and written oral hygiene instructions. OUTCOME MEASUREMENTS: Data collection was performed at T1 (baseline), T2 (6 weeks), T3 (12 weeks) and T4 (18 weeks-end of the study). At each time point, the plaque index (PI), gingival index (GI) and white spot lesion (WSL) score were recorded. Several app-related parameters were evaluated. Patient-related outcome measures were investigated in the test group. RESULTS: Test and control groups were similar at baseline except for WSL score. Between T1 and T4, PI and GI decreased significantly in both groups but evolutions were globally similar in both groups. Interestingly, at T3 (12 weeks), the PI was significantly lower in the app group than in the control group (P = 0.014). Data showed a marked decline in the use of the app over time in the test group. CONCLUSIONS: This trial, conducted over 18 weeks in two academic hospitals, showed no significant effect of the use of the app in promoting oral hygiene. TRIAL REGISTRATION: Not registered.

6.
Angle Orthod ; 89(1): 117-122, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30080129

RESUMEN

OBJECTIVES: To assess patient compliance and treatment efficacy of preventive expansion treatment with removable Planas functional appliances using an integrated microsensor. MATERIALS AND METHODS: Wear time (WT) and behavior of 69 patients undergoing treatment with Planas functional appliances were assessed and analysed using TheraMon microsensors (Gschladt, Hargelsberg, Austria). Patients were followed up for a period of 9 months, and visits were made every 3 months to download WT data from the microsensor and to assess wearing behavior. From individual WT graphs,10 parameters were derived to characterize compliance for each patient. Treatment efficacy was measured by eight parameters determining the level of expansion after 9 months of treatment. RESULTS: Patients wore their device on average 15.8 ± 5.2 h/d. WT was unrelated to age and gender, but it was positively influenced by patient habits when keeping appliances during eating, sports, care and handling. Treatment efficacy in terms of intercanine and intermolar expansion was 4.4 ± 1.9 mm and 4.6 ± 2.0 mm for the maxilla, and 5.3 ± 2.0 mm and 4.7 ± 2.3 mm for the mandible, respectively. Efficacy was negatively affected by poor compliance (WT < 9 h/d) and by high variability of within-subject WT recordings. CONCLUSIONS: Perfect compliance is not necessary to achieve treatment success, but patients should exhibit sufficient wear time to allow maxillary expansion to occur. The TheraMon microsensor offers a new perspective and aid to individualize treatment prescriptions.


Asunto(s)
Aparatos Ortodóncicos Funcionales , Aparatos Ortodóncicos Removibles , Cooperación del Paciente , Atención Odontológica , Humanos , Aparatos Ortodóncicos , Resultado del Tratamiento
8.
Int Orthod ; 16(4): 652-664, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30391131

RESUMEN

BACKGROUND: Piezocision is a localised piezoelectric alveolar decortication involving minimally invasive corticotomies to accelerate orthodontic treatments. The objective of this proof-of-concept was to describe an innovative protocol combining selective piezocision with minimally invasive bone regeneration to reduce the risk of buccal tissue dehiscences often observed in orthodontic treatments. This proof-of-concept initial report aimed at investigating whether this new surgical concept is relevant. MATERIALS AND METHODS: A patient presenting an asymmetrical dental class II, overcrowdings, midline deviations and buccal bone dehiscences in the lower incisor region was treated with this new treatment approach. RESULTS: From an orthodontic point of view, the dental class II, the overcrowdings and the midlines were completely corrected. From a periodontal perspective, no gingival recession was observed; however, scars related to the piezocision were slightly visible at the mandible. The post-imaging demonstrated the absence of bone dehiscences. Up to 3 years after the completion of the treatment, no relapse was observed. CONCLUSION: This novel approach suggested several advantages and may be further investigated at a larger scale in order to validate the benefits and to define the scope of intervention.


Asunto(s)
Proceso Alveolar/cirugía , Regeneración Ósea , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Piezocirugía/métodos , Técnicas de Movimiento Dental/métodos , Proceso Alveolar/diagnóstico por imagen , Materiales Biocompatibles , Femenino , Recesión Gingival/diagnóstico por imagen , Recesión Gingival/cirugía , Recesión Gingival/terapia , Humanos , Maloclusión Clase II de Angle/terapia , Soportes Ortodóncicos , Alambres para Ortodoncia , Osteotomía , Periostio/diagnóstico por imagen , Periostio/cirugía , Tomografía Computarizada por Rayos X , Técnicas de Movimiento Dental/instrumentación , Adulto Joven
9.
Int Orthod ; 14(4): 449-461, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27836768

RESUMEN

A total of 154 adult patients with sleep complaints underwent a polysomnography and a craniofacial cone beam computed tomography (CBCT). OSA was defined as an apnea and hypopnea index (AHI) or an oxygen desaturation index (ODI) ≥ 10. Soft tissues and craniofacial bones volumes were prospectively measured by CBCT and collected blindly from sleep polysomnography. Among the study patients, 127 (83%) suffered from OSA and 27 (17%) did not. OSA patients demonstrated a narrower maxillo-palatine core volume (11.7±3.2 vs 14.6±4.9cm3) even when adjusting for age, gender, height, neck circumference and body mass index. These upper airway measures provide a comprehensive analysis of bony structures and soft tissues, which can be involved in OSA.


Asunto(s)
Huesos Faciales/diagnóstico por imagen , Apnea Obstructiva del Sueño/diagnóstico por imagen , Adulto , Anciano , Tomografía Computarizada de Haz Cónico , Cara/diagnóstico por imagen , Femenino , Cabeza/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Masculino , Maxilar/diagnóstico por imagen , Persona de Mediana Edad , Polisomnografía , Apnea Obstructiva del Sueño/patología , Adulto Joven
11.
Acta Neurol Belg ; 114(2): 87-93, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24442696

RESUMEN

Our understanding of sleep-disordered breathing has evolved considerably over the past three decades, and clinical techniques of evaluation have progressed tremendously. Myriad imaging techniques are now available for the physician to approach the dynamic features resulting in turbulent airflow, upper airway narrowing or collapse at different levels. Controversy exists in the choice of investigations, probably because the best evaluation should be a combination of different techniques. Physical, radiographic, endoscopic and acoustic evaluations could be integrated to understand the degree and the levels of airway reduction and/or obstruction in a given patient. This review focuses on cost-effective and easily implemented techniques in daily practice, allowing quality assessment of the dynamic anatomy of sleep-disordered breathing: cephalometry, (sleep-)endoscopy and acoustic reflectometry of the upper airway.


Asunto(s)
Diagnóstico por Imagen , Esófago/patología , Faringe/patología , Síndromes de la Apnea del Sueño/patología , Cefalometría , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...