Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Nanomedicine ; 18: 595-610, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36760757

RESUMEN

Introduction: The formation of diabetic ulcers (DU) is a common complication for diabetic patients resulting in serious chronic wounds. There is therefore, an urgent need for complex treatment of this problem. This study examines a bioactive wound dressing of a biodegradable electrospun nanofibrous blend of poly(L-lactide-co-ε-caprolactone) and poly(ε-caprolactone) (PLCL/PCL) covered by a thin fibrin layer for sustained delivery of bioactive molecules. Methods: Electrospun PLCL/PCL nanofibers were coated with fibrin-based coating prepared by a controlled technique and enriched with human platelet lysate (hPL), fibroblast growth factor 2 (FGF), and vascular endothelial growth factor (VEGF). The coating was characterized by scanning electron microscopy and fluorescent microscopy. Protein content and its release rate and the effect on human saphenous vein endothelial cells (HSVEC) were evaluated. Results: The highest protein amount is achieved by the coating of PLCL/PCL with a fibrin mesh containing 20% v/v hPL (NF20). The fibrin coating serves as an excellent scaffold to accumulate bioactive molecules from hPL such as PDGF-BB, fibronectin (Fn), and α-2 antiplasmin. The NF20 coating shows both fast and a sustained release of the attached bioactive molecules (Fn, VEGF, FGF). The dressing significantly increases the viability of human saphenous vein endothelial cells (HSVECs) cultivated on a collagen-based wound model. The exogenous addition of FGF and VEGF during the coating procedure further increases the HSVECs viability. In addition, the presence of α-2 antiplasmin significantly stabilizes the fibrin mesh and prevents its cleavage by plasmin. Discussion: The NF20 coating supplemented with FGF and VEGF provides a promising wound dressing for the complex treatment of DU. The incorporation of various bioactive molecules from hPL and growth factors has great potential to support the healing processes by providing appropriate stimuli in the chronic wound.


Asunto(s)
Nanofibras , Factor A de Crecimiento Endotelial Vascular , Humanos , alfa 2-Antiplasmina , Poliésteres/farmacología , Células Endoteliales , Cicatrización de Heridas , Vendajes
2.
Cardiovasc Intervent Radiol ; 45(2): 236-243, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34913987

RESUMEN

PURPOSE: Due to thromboembolic complications and in-stent-stenosis after flow diverter (FD) treatment, the long-term use of dual antiplatelet treatment (DAPT) is mandatory. The tested nano-coating has been shown to reduce material thrombogenicity and promote endothelial cell proliferation in vitro. We compared the biocompatibility of coated (Derivo Heal) and non-coated (Derivo bare) FDs with DAPT in an animal model. METHODS: Derivo® bare (n = 10) and Derivo® Heal (n = 10) FD were implanted in the common carotid arteries (CCAs) of New Zealand white rabbits. One additional FD, alternately a Derivo bare (n = 5) or Derivo Heal (n = 5), was implanted in the abdominal aorta (AA) for assessment of the patency of branch arteries. Histopathological examinations were performed after 28 days. Angiography was performed before and after FD implantation and at follow-up. RESULTS: Statistical analysis of the included specimens showed complete endothelialization of all FDs with no significant differences in neointima thickness between Derivo® bare and Derivo® Heal (CCA: p = 0.91; AA: p = 0.59). A significantly reduced number of macrophages in the vessel wall of the Derivo Heal was observed for the CCA (p = 0.02), and significantly reduced fibrin and platelet deposition on the surface of the Derivo Heal was observed for the AA. All branch arteries of the stented aorta remained patent. CONCLUSION: In this animal model, the novel fibrin-based coated FD showed a similar blood and tissue compatibility as the non-coated FD.


Asunto(s)
Fibrina , Stents , Animales , Plaquetas , Arteria Carótida Común , Materiales Biocompatibles Revestidos , Neointima , Conejos
3.
Nanomaterials (Basel) ; 11(2)2021 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-33670150

RESUMEN

Chronic wounds affect millions of patients worldwide, and it is estimated that this number will increase steadily in the future due to population ageing. The research of new therapeutic approaches to wound healing includes the development of nanofibrous meshes and the use of platelet lysate (PL) to stimulate skin regeneration. This study considers a combination of a degradable electrospun nanofibrous blend of poly(L-lactide-co-ε-caprolactone) and poly(ε-caprolactone) (PLCL/PCL) membranes (NF) and fibrin loaded with various concentrations of PL aimed at the development of bioactive skin wound healing dressings. The cytocompatibility of the NF membranes, as well as the effect of PL, was evaluated in both monocultures and co-cultures of human keratinocytes and human endothelial cells. We determined that the keratinocytes were able to adhere on all the membranes, and their increased proliferation and differentiation was observed on the membranes that contained fibrin with at least 50% of PL (Fbg + PL) after 14 days. With respect to the co-culture experiments, the membranes with fibrin with 20% of PL were observed to enhance the metabolic activity of endothelial cells and their migration, and the proliferation and differentiation of keratinocytes. The results suggest that the newly developed NF combined with fibrin and PL, described in the study, provides a promising dressing for chronic wound healing purposes.

4.
Biomed Mater ; 16(2): 025024, 2021 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-33629665

RESUMEN

An ideal decellularized allogenic or xenogeneic cardiovascular graft should be capable of preventing thrombus formation after implantation. The antithrombogenicity of the graft is ensured by a confluent endothelial cell layer formed on its surface. Later repopulation and remodeling of the scaffold by the patient's cells should result in the formation of living autologous tissue. In the work presented here, decellularized porcine pericardium scaffolds were modified by growing a fibrin mesh on the surface and inside the scaffolds, and by attaching heparin and human vascular endothelial growth factor (VEGF) to this mesh. Then the scaffolds were seeded with human adipose tissue-derived stem cells (ASCs). While the ASCs grew only on the surface of the decellularized pericardium, the fibrin-modified scaffolds were entirely repopulated in 28 d, and the scaffolds modified with fibrin, heparin and VEGF were already repopulated within 6 d. Label free mass spectrometry revealed fibronectin, collagens, and other extracellular matrix proteins produced by ASCs during recellularization. Thin layers of human umbilical endothelial cells were formed within 4 d after the cells were seeded on the surfaces of the scaffold, which had previously been seeded with ASCs. The results indicate that an artificial tissue prepared by in vitro recellularization and remodeling of decellularized non-autologous pericardium with autologous ASCs seems to be a promising candidate for cardiovascular grafts capable of accelerating in situ endothelialization. ASCs resemble the valve interstitial cells present in heart valves. An advantage of this approach is that ASCs can easily be collected from the patient by liposuction.


Asunto(s)
Válvulas Cardíacas , Pericardio/metabolismo , Ingeniería de Tejidos/métodos , Andamios del Tejido , Tejido Adiposo/citología , Animales , Bioprótesis , Proliferación Celular , Colágeno/química , Matriz Extracelular Descelularizada/química , Células Endoteliales/citología , Matriz Extracelular/metabolismo , Fibrinógeno/química , Fibronectinas/química , Células Endoteliales de la Vena Umbilical Humana , Humanos , Técnicas In Vitro , Lipectomía , Microscopía Fluorescente , Pericardio/patología , Células Madre , Porcinos , Trombina/química , Andamios del Tejido/química , Factor A de Crecimiento Endotelial Vascular/metabolismo
5.
RSC Adv ; 11(11): 5903-5913, 2021 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-35423133

RESUMEN

Early and late thrombosis remain the most frequent reasons for the failure of synthetic cardiovascular grafts. Long-term hemocompatibility of implanted synthetic grafts can be achieved if a natural living endothelium is formed over its blood-contacting surface. Here we present a modification of a standard expanded polytetrafluorethylene (ePTFE) vessel prosthesis by a controlled preparation of a fibrin mesh enriched with covalently bound heparin and noncovalently bound vascular endothelial growth factor (VEGF) and fibroblast growth factor (FGF). Compared to a bare prosthesis, the coated prosthesis showed excellent antithrombogenic properties after contact with heparinized fresh human blood. Human umbilical vein endothelial cells seeded on the inner surface of the coated prosthesis formed a confluent layer in 5 days, whereas only small colonies of cells were scattered on the bare prosthesis. Viability of the cells was promoted mainly by FGF immobilized on the coating. These findings suggest that the coating may prevent acute thrombus formation and support the self-endothelialization of an implanted ePTFE vascular graft in vivo.

6.
J Vis Exp ; (157)2020 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-32202530

RESUMEN

The growing use of medical devices (e.g., vascular grafts, stents, and cardiac catheters) for temporary or permanent purposes that remain in the body's circulatory system demands a reliable and multiparametric approach that evaluates the possible hematologic complications caused by these devices (i.e., activation and destruction of blood components). Comprehensive in vitro hemocompatibility testing of blood-contacting implants is the first step towards successful in vivo implementation. Therefore, extensive analysis according to the International Organization for Standardization 10993-4 (ISO 10993-4) is mandatory prior to clinical application. The presented flow loop describes a sensitive model to analyze the hemostatic performance of stents (in this case, neurovascular) and reveal adverse effects. The use of fresh human whole blood and gentle blood sampling are essential to avoid the preactivation of blood. The blood is perfused through a heparinized tubing containing the test specimen by using a peristaltic pump at a rate of 150 mL/min at 37 °C for 60 min. Before and after perfusion, hematologic markers (i.e., blood cell count, hemoglobin, hematocrit, and plasmatic markers) indicating the activation of leukocytes (polymorphonuclear [PMN]-elastase), platelets (ß-thromboglobulin [ß-TG]), the coagulation system (thombin-antithrombin III [TAT]), and the complement cascade (SC5b-9) are analyzed. In conclusion, we present an essential and reliable model for extensive hemocompatibility testing of stents and other blood-contacting devices prior to clinical application.


Asunto(s)
Circulación Sanguínea/fisiología , Prótesis Vascular , Ensayo de Materiales/métodos , Modelos Biológicos , Biomarcadores/metabolismo , Recuento de Células Sanguíneas , Circulación Sanguínea/efectos de los fármacos , Recolección de Muestras de Sangre , Proteínas del Sistema Complemento/metabolismo , Heparina/farmacología , Humanos , Sistema Inmunológico/metabolismo , Elastasa Pancreática/metabolismo , Plasma , Stents , beta-Tromboglobulina/metabolismo
7.
Biomed Mater ; 15(1): 015008, 2019 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-31665713

RESUMEN

Decellularized human pericardium is under study as an allogenic material for cardiovascular applications. The effects of crosslinking on the mechanical properties of decellularized pericardium were determined with a uniaxial tensile test, and the effects of crosslinking on the collagen structure of decellularized pericardium were determined by multiphoton microscopy. The viability of human umbilical vein endothelial cells seeded on decellularized human pericardium and on pericardium strongly and weakly crosslinked with glutaraldehyde and with genipin was evaluated by means of an MTS assay. The viability of the cells, measured by their metabolic activity, decreased considerably when the pericardium was crosslinked with glutaraldehyde. Conversely, the cell viability increased when the pericardium was crosslinked with genipin. Coating both non-modified pericardium and crosslinked pericardium with a fibrin mesh or with a mesh containing attached heparin and/or fibronectin led to a significant increase in cell viability. The highest degree of viability was attained for samples that were weakly crosslinked with genipin and modified by means of a fibrin and fibronectin coating. The results indicate a method by which in vivo endothelialization of human cardiac allografts or xenografts could potentially be encouraged.


Asunto(s)
Materiales Biocompatibles , Pericardio/trasplante , Aloinjertos , Animales , Materiales Biocompatibles/química , Fenómenos Biomecánicos , Supervivencia Celular , Colágeno/química , Colágeno/ultraestructura , Reactivos de Enlaces Cruzados , Fibrina , Fibronectinas , Glutaral , Xenoinjertos , Células Endoteliales de la Vena Umbilical Humana/citología , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Humanos , Iridoides , Ensayo de Materiales , Microscopía de Fluorescencia por Excitación Multifotónica , Pericardio/química , Pericardio/ultraestructura , Resonancia por Plasmón de Superficie , Resistencia a la Tracción
8.
J Biomed Mater Res A ; 105(11): 2995-3005, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28646555

RESUMEN

Long-term performance of implanted cardiovascular grafts can be ensured if living endothelium overgrows their surface. Surface modifications to implants are therefore being sought that can encourage endothelialization while preventing thrombus formation until the natural endothelium is formed. In the present study, heparin was covalently attached to a fibrin mesh grown from a polyvinyl chloride (PVC) substrate surface by the catalytic action of surface immobilized thrombin on a fibrinogen solution. The coating prevented platelet activation, thrombin generation and clot formation, and reduced inflammatory reactions when exposed to fresh human whole blood circulating in a Chandler loop model. In addition, in vitro seeded human umbilical vein and human saphenous vein endothelial cells showed considerably enhanced attachment and proliferation on the coating. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2995-3005, 2017.


Asunto(s)
Anticoagulantes/química , Anticoagulantes/farmacología , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Heparina/química , Heparina/farmacología , Trombosis/prevención & control , Coagulación Sanguínea/efectos de los fármacos , Prótesis Vascular/efectos adversos , Adhesión Celular/efectos de los fármacos , Células Cultivadas , Células Endoteliales/citología , Células Endoteliales/efectos de los fármacos , Fibrina/química , Hematócrito , Células Endoteliales de la Vena Umbilical Humana , Humanos , Activación Plaquetaria/efectos de los fármacos , Vena Safena/citología , Trombosis/sangre , Trombosis/etiología
9.
Int J Nanomedicine ; 12: 1143-1160, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28223803

RESUMEN

Protein-coated resorbable synthetic polymeric nanofibrous membranes are promising for the fabrication of advanced skin substitutes. We fabricated electrospun polylactic acid and poly(lactide-co-glycolic acid) nanofibrous membranes and coated them with fibrin or collagen I. Fibronectin was attached to a fibrin or collagen nanocoating, in order further to enhance the cell adhesion and spreading. Fibrin regularly formed a coating around individual nanofibers in the membranes, and also formed a thin noncontinuous nanofibrous mesh on top of the membranes. Collagen also coated most of the fibers of the membrane and randomly created a soft gel on the membrane surface. Fibronectin predominantly adsorbed onto a thin fibrin mesh or a collagen gel, and formed a thin nanofibrous structure. Fibrin nanocoating greatly improved the attachment, spreading, and proliferation of human dermal fibroblasts, whereas collagen nanocoating had a positive influence on the behavior of human HaCaT keratinocytes. In addition, fibrin stimulated the fibroblasts to synthesize fibronectin and to deposit it as an extracellular matrix. Fibrin coating also showed a tendency to improve the ultimate tensile strength of the nanofibrous membranes. Fibronectin attached to fibrin or to a collagen coating further enhanced the adhesion, spreading, and proliferation of both cell types.


Asunto(s)
Colágeno/metabolismo , Fibrina/metabolismo , Fibroblastos/citología , Queratinocitos/citología , Nanofibras/química , Polímeros/química , Andamios del Tejido/química , Adhesión Celular , Proliferación Celular , Células Cultivadas , Matriz Extracelular/metabolismo , Fibroblastos/metabolismo , Fibronectinas/metabolismo , Humanos , Queratinocitos/metabolismo , Resistencia a la Tracción , Ingeniería de Tejidos
10.
Anal Chem ; 89(6): 3524-3531, 2017 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-28233990

RESUMEN

Fouling from complex biological fluids such as blood plasma to biorecognition element (BRE)-functionalized coatings hampers the use of affinity biosensor technologies in medical diagnostics. Here, we report the effects the molecular mechanisms involved in functionalization of low-fouling carboxy-functional coatings have on the BRE capacity and resistance to fouling from blood plasma. The specific mechanisms of EDC/NHS activation of carboxy groups, BRE attachment, and deactivation of residual activated groups on recently developed ultra-low-fouling carboxybetaine polymer and copolymer brushes (pCB) as well as conventional carboxy-terminated oligo(ethylene glycol)-based alkanethiolate self-assembled monolayers (OEG-SAMs) are studied using the polarization modulation infrared reflection/absorption spectroscopy, X-ray photoelectron spectroscopy, and surface plasmon resonance methods. It is shown that the fouling resistance of BRE-functionalized pCB coatings is strongly influenced by a deactivation method affecting the ultra-low-fouling molecular structure of the brush and surface charges. It is revealed that, in contrast to free carboxy-group-terminated OEG-SAMs, only a partial deactivation of EDC/NHS-activated zwitterionic carboxy groups by spontaneous hydrolysis is possible in the pCB brushes. The fouling resistance of activated/BRE-functionalized pCB is shown to be recovered only by covalent attachment of amino acid deactivation agents to residual activated carboxy groups of pCB. The developed deactivation procedure is further combined with ultra-low-fouling brushes of random copolymer carboxybetaine methacrylamide (CBMAA) and N-(2-hydroxypropyl) methacrylamide (HPMAA) with optimized CBMAA content (15%) providing a BRE-functionalized coating with superior fouling resistance over various carboxy-functional low-fouling coatings including homopolymer pCB brushes and OEG-SAMs. The biorecognition capabilities of pHPMAA-CBMAA(15%) are demonstrated via the sensitive label-free detection of a microRNA cancer biomarker (miR-16) in blood plasma.


Asunto(s)
Materiales Biocompatibles Revestidos/metabolismo , Polímeros/metabolismo , Materiales Biocompatibles Revestidos/química , Humanos , Estructura Molecular , Espectroscopía de Fotoelectrones , Polímeros/síntesis química , Polímeros/química
11.
Anal Chem ; 89(5): 2972-2977, 2017 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-28192973

RESUMEN

A biosensor for the detection of hepatitis B antibodies in clinical saliva was developed. Compared to conventional analysis of blood serum, it offers the advantage of noninvasive collection of samples. Detection of biomarkers in saliva imposes two major challenges associated with the low analyte concentration and increased surface fouling. The detection of minute amounts of hepatitis B antibodies was performed by plasmonically amplified fluorescence sandwich immunoassay. To have access to specific detection, we prevented the nonspecific adsorption of biomolecules present in saliva by brushes of poly[(N-(2-hydroxypropyl) methacrylamide)-co-(carboxybetaine methacrylamide)] grafted from the gold sensor surface and post modified with hepatitis B surface antigen. Obtained results were validated against the response measured with ELISA at a certified laboratory using serum from the same patients.


Asunto(s)
Técnicas Biosensibles/métodos , Anticuerpos contra la Hepatitis B/análisis , Antígenos de Superficie de la Hepatitis B/química , Saliva/metabolismo , Biomarcadores/análisis , Oro/química , Anticuerpos contra la Hepatitis B/sangre , Anticuerpos contra la Hepatitis B/inmunología , Antígenos de Superficie de la Hepatitis B/inmunología , Humanos , Proteínas Inmovilizadas/química , Proteínas Inmovilizadas/inmunología , Inmunoensayo , Polímeros/química , Espectrometría de Fluorescencia , Resonancia por Plasmón de Superficie
13.
Anal Chem ; 88(21): 10533-10539, 2016 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-27689386

RESUMEN

Functional polymer coatings that combine the ability to resist nonspecific fouling from complex media with high biorecognition element (BRE) immobilization capacity represent an emerging class of new functional materials for a number of bioanalytical and biosensor technologies for medical diagnostics, security, and food safety. Here, we report on a random copolymer brush surface - poly(CBMAA-ran-HPMAA) - providing high BRE immobilization capacity while simultaneously exhibiting ultralow-fouling behavior in complex food media. We demonstrate that both the functionalization and fouling resistance capabilities of such copolymer brushes can be tuned by changing the surface contents of the two monomer units: nonionic N-(2-hydroxypropyl) methacrylamide (HPMAA) and carboxy-functional zwitterionic carboxybetaine methacrylamide (CBMAA). It is demonstrated that the resistance to fouling decreases with the surface content of CBMAA; poly(CBMAA-ran-HPMAA) brushes with CBMAA molar content up to 15 mol % maintain excellent resistance to fouling from a variety of homogenized foods (hamburger, cucumber, milk, and lettuce) even after covalent attachment of BREs to carboxy groups of CBMAA. The poly(CBMAA 15 mol %-ran-HPMAA) brushes functionalized with antibodies are demonstrated to exhibit fouling resistance from food samples by up to 3 orders of magnitude better when compared with the widely used low-fouling carboxy-functional oligo(ethylene glycol) (OEG)-based alkanethiolate self-assembled monolayers (AT SAMs) and, furthermore, by up to 2 orders of magnitude better when compared with the most successful ultralow-fouling biorecognition coatings - poly(carboxybetaine acrylamide), poly(CBAA). When model SPR detections of food-borne bacterial pathogens in homogenized foods are used, it is also demonstrated that the antibody-functionalized poly(CBMAA 15 mol %-ran-HPMAA) brush exhibits superior biorecognition properties over the poly(CBAA).


Asunto(s)
Acrilamidas/química , Resinas Acrílicas/química , Incrustaciones Biológicas/prevención & control , Inocuidad de los Alimentos/métodos , Resinas Acrílicas/síntesis química , Anticuerpos/química , Escherichia coli/inmunología , Alimentos , Oro/química , Nanopartículas/química , Salmonella typhimurium/inmunología , Humectabilidad
14.
PLoS One ; 11(10): e0163697, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27716773

RESUMEN

We describe the production of a highly-active mutant VEGF variant, α2-PI1-8-VEGF121, which contains a substrate sequence for factor XIIIa at the aminoterminus designed for incorporation into a fibrin gel. The α2-PI1-8-VEGF121 gene was synthesized, cloned into a pET-32a(+) vector and expressed in Escherichia coli Origami B (DE3) host cells. To increase the protein folding and the solubility, the resulting thioredoxin-α2-PI1-8-VEGF121 fusion protein was co-expressed with recombinant molecular chaperones GroES/EL encoded by independent plasmid pGro7. The fusion protein was purified from the soluble fraction of cytoplasmic proteins using affinity chromatography. After cleavage of the thioredoxin fusion part with thrombin, the target protein was purified by a second round of affinity chromatography. The yield of purified α2-PI1-8-VEGF121 was 1.4 mg per liter of the cell culture. The α2-PI1-8-VEGF121 expressed in this work increased the proliferation of endothelial cells 3.9-8.7 times in comparison with commercially-available recombinant VEGF121. This very high mitogenic activity may be caused by co-expression of the growth factor with molecular chaperones not previously used in VEGF production. At the same time, α2-PI1-8-VEGF121 did not elicit considerable inflammatory activation of human endothelial HUVEC cells and human monocyte-like THP-1 cells.


Asunto(s)
Escherichia coli/metabolismo , Chaperonas Moleculares/metabolismo , Proteínas Recombinantes de Fusión/metabolismo , Factor A de Crecimiento Endotelial Vascular/metabolismo , Secuencia de Aminoácidos , Células Cultivadas , Cromatografía de Afinidad/métodos , Clonación Molecular , Fibrina/metabolismo , Células Endoteliales de la Vena Umbilical Humana , Humanos , Plásmidos/metabolismo , Pliegue de Proteína , Solubilidad , Tiorredoxinas/metabolismo
15.
Biosens Bioelectron ; 85: 272-279, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27179568

RESUMEN

A plasmonic biosensor for rapid detection of protein biomarkers in complex media is reported. Clinical serum samples were analyzed by using a novel biointerface architecture based on poly[(N-(2-hydroxypropyl) methacrylamide)-co-(carboxybetaine methacrylamide)] brushes functionalized with bioreceptors. This biointerface provided an excellent resistance to fouling even after the functionalization and allowed for the first time the direct detection of antibodies against hepatitis B surface antigen (anti-HBs) in clinical serum samples using surface plasmon resonance (SPR). The fabricated SPR biosensor allowed discrimination of anti-HBs positive and negative clinical samples in 10min. Results are validated by enzyme-linked immunoassays of the sera in a certified laboratory. The sensor could be regenerated by simple treatment with glycine buffer.


Asunto(s)
Anticuerpos Antivirales/sangre , Virus de la Hepatitis B/inmunología , Hepatitis B/sangre , Resonancia por Plasmón de Superficie/instrumentación , Acrilamidas/química , Anticuerpos Antivirales/inmunología , Diseño de Equipo , Hepatitis B/inmunología , Antígenos de Superficie de la Hepatitis B/inmunología , Virus de la Hepatitis B/aislamiento & purificación , Humanos , Límite de Detección , Propiedades de Superficie
16.
Int J Nanomedicine ; 11: 771-89, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26955273

RESUMEN

Fibrin plays an important role during wound healing and skin regeneration. It is often applied in clinical practice for treatment of skin injuries or as a component of skin substitutes. We prepared electrospun nanofibrous membranes made from poly(l-lactide) modified with a thin fibrin nanocoating. Fibrin surrounded the individual fibers in the membrane and also formed a thin fibrous mesh on several places on the membrane surface. The cell-free fibrin nanocoating remained stable in the cell culture medium for 14 days and did not change its morphology. On membranes populated with human dermal fibroblasts, the rate of fibrin degradation correlated with the degree of cell proliferation. The cell spreading, mitochondrial activity, and cell population density were significantly higher on membranes coated with fibrin than on nonmodified membranes, and this cell performance was further improved by the addition of ascorbic acid in the cell culture medium. Similarly, fibrin stimulated the expression and synthesis of collagen I in human dermal fibroblasts, and this effect was further enhanced by ascorbic acid. The expression of beta1-integrins was also improved by fibrin, and on pure polylactide membranes, it was slightly enhanced by ascorbic acid. In addition, ascorbic acid promoted deposition of collagen I in the form of a fibrous extracellular matrix. Thus, the combination of nanofibrous membranes with a fibrin nanocoating and ascorbic acid seems to be particularly advantageous for skin tissue engineering.


Asunto(s)
Electroquímica/métodos , Fibrina/química , Fibroblastos/citología , Nanofibras/química , Poliésteres/química , Piel/citología , Ingeniería de Tejidos/métodos , Diferenciación Celular , Proliferación Celular , Células Cultivadas , Colágeno/genética , Colágeno/metabolismo , Matriz Extracelular/metabolismo , Fibrina/metabolismo , Fibroblastos/metabolismo , Técnica del Anticuerpo Fluorescente , Humanos , Técnicas para Inmunoenzimas , ARN Mensajero/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Regeneración/fisiología , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Piel/metabolismo
17.
Anal Bioanal Chem ; 407(14): 3927-53, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25821150

RESUMEN

This review focuses on recent advances in the development of functionalizable antifouling coatings and their applications in label-free optical biosensors. Approaches to the development of antifouling coatings, ranging from self-assembled monolayers and PEG derivatives to ultra-low-fouling polymer brushes, are reviewed. Methods of preparation and characterization of antifouling coatings and the functionalization of antifouling coatings with bioreceptors are reviewed, and the effect of functionalization on the fouling properties of biofunctional coating is discussed. Special attention is given to biofunctional coatings for label-free bioanalysis of blood plasma and serum for medical diagnostics.


Asunto(s)
Incrustaciones Biológicas , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Plasma/química , Suero/química , Polímeros
18.
Bioanalysis ; 6(24): 3325-36, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25534789

RESUMEN

Surface plasmon resonance sensors have made vast advancements in the sensing technology and the number of applications achievable. New developments in surface plasmon resonance sensors have gained considerable momentum promoted by the urgent needs of fast, reliable and label-free methods for detection and quantification of analytes in molecular biology, medicine and other life sciences. However, even if enormous improvements in the limits of detections have been achieved, this technology still faces important challenges to be translated to clinical practice or in-field measurements. This paper reviews the important recent advances of this technology for the label-free detection in real biological samples and we discussed the key challenges to be overcome to transit from prototypes to commercial biosensors.


Asunto(s)
Biología/métodos , Resonancia por Plasmón de Superficie/métodos , Biología/instrumentación , Diagnóstico , Humanos , Resonancia por Plasmón de Superficie/instrumentación
19.
Adv Mater ; 26(24): 4087-92, 2014 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-24719300

RESUMEN

Functional cellulose substrates with tetrazole moieties are generated to serve as universal platforms for the spatio-temporal immobilization of synthetic ultra-low fouling polymer brushes and protein species via a nitrile imine-mediated tetrazole-ene cycloaddition (NITEC)-based protocol. Poly(carboxybetaine acrylamide) brushes are grafted from initiators photo-patterned by NITEC utilizing single electron transfer living radical polymerization. Streptavidin is photo-immobilized with remarkable efficiency, opening the possibility to generate new materials for biomedical and biosensing applications.


Asunto(s)
Técnicas Biosensibles/métodos , Inmunoensayo/métodos , Impresión Molecular/métodos , Papel , Fotograbar/métodos , Análisis por Matrices de Proteínas/métodos , Estreptavidina/química , Adsorción/efectos de la radiación , Ensayo de Materiales , Fotoquímica/métodos , Propiedades de Superficie/efectos de la radiación
20.
Tissue Eng Part A ; 20(15-16): 2253-64, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24606163

RESUMEN

Vascular surgery for atherosclerosis is confronted by the lack of a suitable bypass material. Tissue engineering strives to produce bio-artificial conduits to provide resistance to thrombosis. The objectives of our study were to culture endothelial cells (EC) on composite assemblies of extracellular matrix proteins, and to evaluate the cellular phenotype under flow. Cell-adhesive assemblies were fabricated on glass slides as combinations of collagen (Co), laminin (LM), and fibronectin (FN), resulting in three samples: Co, Co/LM, and Co/FN. Surface topography, roughness, and wettability were determined. Human saphenous vein EC were harvested from cardiac patients, cultured on the assemblies and submitted to laminar shear stress (SS) of 12 dyn/cm(2) for 40, 80, and 120 min. Cell retention was assessed and qRT-PCR of adhesion genes (VE-cadherin, vinculin, KDR, CD-31 or PECAM-1, ß1-integrins) and metabolic genes (t-PA, NF-κB, eNOS and MMP-1) was performed. Quantitative immunofluorescence of VE cadherin, vinculin, KDR, and vonWillebrand factor was performed after 2 and 6 h of flow. Static samples were excluded from shearing. The cells reached confluence with similar growth curves. The cells on Co/LM and Co/FN were resistant to flow up to 120 min but minor desquamation occurred on Co corresponding with temporary downregulation of VE cadherin and vinculin-mRNA and decreased fluorescence of vinculin. The cells seeded on Co/LM initially more upregulated vinculin-mRNA and also the inflammatory factor NF-κB, and the cells plated on Co/FN changed the expression profile minimally in comparison with the static control. Fluorescence of VE cadherin and vonWillebrand factor was enhanced on Co/FN. The cells cultured on Co/LM and Co/FN increased the vinculin fluorescence and expressed more VE cadherin and KDR-mRNA than the cells on Co. The cells plated on Co/FN upregulated the mRNA of VE cadherin, CD-31, and MMP 1 to a greater extent than the cells on Co/LM and they enhanced the fluorescence of VE cadherin, KDR, and vonWillebrand factor. Some of these changes sustained up to 6 h of flow, as confirmed by immunofluorescence. Combined matrices Co/LM and Co/FN seem to be more suitable for EC seeding and retention under flow. Moreover, Co/FN matrix promoted slightly more favorable cellular phenotype than Co/LM under SS of 2-6 h.


Asunto(s)
Células Endoteliales/metabolismo , Proteínas de la Matriz Extracelular/farmacología , Regulación de la Expresión Génica/efectos de los fármacos , Resistencia al Corte , Estrés Mecánico , Animales , Adhesión Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Células Endoteliales/efectos de los fármacos , Técnica del Anticuerpo Fluorescente , Perfilación de la Expresión Génica , Humanos , Ratones , Ratas , Vena Safena/citología , Resonancia por Plasmón de Superficie , Factores de Tiempo , Humectabilidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...