Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Arch Orthop Trauma Surg ; 144(4): 1843-1850, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38400899

RESUMEN

INTRODUCTION: The adoption of new technology should be supported by improvements in patient-reported outcomes (PROMs). The purpose of this study was to assess the one-year PROMs of patients who underwent total hip arthroplasty (THA) using a novel, fluoroscopy-based, robotic-assisted (RA-THA) system when compared to a manual, fluoroscopic-assisted technique (mTHA). MATERIALS AND METHODS: A review of 91 consecutive mTHA and 85 consecutive RA-THA via a direct anterior approach was conducted. All cases were performed by the same surgeon at the same institution, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Outcomes included one-year Veterans RAND-12 (VR-12) Physical/Mental, Hip Disability and Osteoarthritis Outcome (HOOS) Pain/Physical Function/Joint Replacement, and University of California Los Angeles (UCLA) Activity scores, as well as the difference between pre-operative and one-year post-operative PROMs. RESULTS: Patients in the RA-THA cohort had lower pre-operative HOOS-JR scores compared to patients in the mTHA cohort (37.0 vs. 43.1; p = 0.031). Cohorts experienced similar one-year post-operative VR-12, HOOS, and UCLA Activity scores. Patients in the RA-THA cohort experienced greater improvements across all pre- and post-operative HOOS scores compared to patients in the mTHA cohort: Pain (+ 54.7 vs. +42.1; p = 0.009), Physical Function (-41.6 vs. -28.7; p = 0.007), and Joint Replacement (+ 46.6 vs. +33.0; p = 0.002). These differences exceeded minimum clinically important difference (MCID). CONCLUSIONS: Both manual and robotic cohorts experienced benefit from THA at one-year post-operative. Importantly, the use of a novel, fluoroscopy-based robotic assistance system for primary THA resulted in greater improvements in PROMs at one-year relative to manual technique.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osteoartritis , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Resultado del Tratamiento , Medición de Resultados Informados por el Paciente , Dolor , Fluoroscopía
2.
Med Eng Phys ; 124: 104105, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38418018

RESUMEN

Accurate pre-operative templating of prosthesis components is an essential factor in successful total hip arthroplasty (THA), including robotically-assisted THA (RA-THA) techniques. We sought to validate the accuracy of a novel, robotic-optimized THA planning software compared to a predicate THA planner for component sizing. We analyzed a series of 199 patients who received manual THA (mTHA) and fluoroscopy-based RA-THA at a single institution. All cases were templated using a predicate pre-operative templating software. For RA-THA cases, the novel robotic-optimized pre-operative planner software was also used for templating. The differences between templated and implanted acetabular cup, femoral head, and stem component sizes were compared based on matching within 1, 2, and ≥3 sizes. Differences in templated and implanted femoral stem implant geometry were also compared. The robot-optimized pre-operative RA-THA plans demonstrated equivalent accuracy to that of predicate pre-operative plans for both RA-THA and mTHA cases. Templated acetabular cups (90.4 vs. 86.8 vs. 82.8; p = 0.421), femoral stems (76.0 vs. 65.1 vs. 67.7; p = 0.096), and femoral heads (91.3 vs. 96.2 vs. 88.2; p = 0.302) were within +/-1 size of implanted components. No significant differences were detected in the proportion of matching templated and implanted stem geometry across the study cohorts.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/cirugía , Reproducibilidad de los Resultados , Cuidados Preoperatorios/métodos , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Programas Informáticos , Estudios Retrospectivos
3.
Arch Orthop Trauma Surg ; 144(1): 501-508, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37740783

RESUMEN

BACKGROUND: While robotic-assisted total hip arthroplasty (RA-THA) has been associated with improved accuracy of component placement, the perioperative and early postoperative outcomes of fluoroscopy-based RA-THA systems have yet to be elucidated. METHODS: This retrospective cohort analysis included a consecutive series of patients who received manual, fluoroscopy-assisted THA (mTHA) and fluoroscopy-based RA-THA at a single institution. We compared rates of complications within 90 days of surgery, length of hospital stay (LOS), and visual analog scale (VAS) pain scores. RESULTS: No differences existed between groups with respect to demographic data or perioperative recovery protocols. The RA-THA cohort had a significantly greater proportion of outpatient surgeries compared to the mTHA cohort (37.4% vs. 3.8%; p < 0.001) and significantly lower LOS (26.0 vs. 39.5 h; p < 0.001). The RA-THA cohort had a smaller 90-day postoperative complication rate compared to the mTHA cohort (0.9% vs. 6.7%; p = 0.029). The RA-THA cohort had significantly lower patient-reported VAS pain scores at 2-week follow-up visits (2.5 vs. 3.3; p = 0.048), but no difference was seen after 6-week follow visits (2.5 vs. 2.8; p = 0.468). CONCLUSION: Fluoroscopy-based RA-THA demonstrates low rates of postoperative complications, improved postoperative pain profiles, and shortened LOS when compared to manual, fluoroscopy-assisted THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Resultado del Tratamiento , Fluoroscopía , Complicaciones Posoperatorias , Dolor Postoperatorio
4.
Technol Health Care ; 2023 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-37980586

RESUMEN

BACKGROUND: Robotic assistance in total hip arthroplasty (RA-THA) has been shown to minimize laterality-based differences in acetabular cup positioning. OBJECTIVE: To determine if the use of a novel, fluoroscopy-based RA-THA system mitigates differences in acetabular cup placement between left (L) and right (R) side hip procedures, when compared to manual, fluoroscopic-assisted technique. METHODS: We conducted a retrospective review of 106 consecutive mTHA (40 L/66 R) and 102 RA-THA (48 L/54 R) primary direct anterior approach procedures. All cases were performed by a single right-hand-dominant surgeon, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Outcomes included acetabular cup inclination and anteversion, and the proportion of cups within the Lewinnek safe-zone. RESULTS: The average inclination of mTHA L cases was smaller than that of mTHA R cases (41.10∘± 7.38 vs. 43.97∘± 6.27; p= 0.04). For RA-THA, L and R cup angles were similar. There were fewer overall mTHA hips within the Lewinnek safe-zone compared to RA-THA (0.59 vs. 0.78; p= 0.003), as well as fewer mTHA R cases than RA-THA R cases (0.59 vs. 0.80; p= 0.03) within safe zone. CONCLUSION: Use of a novel, fluoroscopy-based robotic system mitigates laterality-based differences in acetabular cup placement that were observed in a manual, fluoroscopic-assisted cohort.

5.
Technol Health Care ; 2023 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-37980587

RESUMEN

BACKGROUND: Patient obesity is a risk factor for poor acetabular cup positioning in total hip arthroplasty (THA). OBJECTIVE: To assess the impact of using a novel, fluoroscopy-based robotic THA system on acetabular cup placement in obese versus non-obese patients. METHODS: A review of 105 consecutive manual unassisted (mTHA) (47 Obese/58 Non-obese) and 102 robotic-assisted (RA-THA) (50 Obese/52 Non-obese) primary, direct anterior approach THA procedures was conducted. All cases were performed by a single surgeon, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Obesity was defined as a Body Mass Index (BMI) ⩾ 30 kg/m2. Outcomes included acetabular cup inclination and anteversion, and the proportion of cups within the Lewinnek safe-zone. RESULTS: Obese patients in the mTHA cohort had larger cup inclination angles on average compared to non-obese patients (44.82∘± 6.51 vs. 41.39∘± 6.75; p= 0.009). Obese mTHA patients were less likely to have cup placement within the Lewinnek zone compared to non-obese mTHA patients (0.48 vs. 0.67; p= 0.027). Obesity had no effect on the accuracy of RA-THA. CONCLUSION: Obesity affects the placement of the acetabular component in manual THA. The novel, fluoroscopy-based robotic THA system in this study demonstrated accurate cup placement regardless of obesity status.

6.
Arthroplasty ; 5(1): 56, 2023 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-37924164

RESUMEN

BACKGROUND: Robot-assisted total hip arthroplasty (RA-THA) improves accuracy in achieving the planned acetabular cup positioning compared to conventional manual THA (mTHA), but optimal dosage for peri-RA-THA and mTHA pain relief remains unclear. This study aimed to compare pain control with opioids between patients undergoing direct anterior approach THA with the use of a novel, fluoroscopic-assisted RA-THA system compared to opioid consumption associated with fluoroscopic-assisted, manual technique. METHODS: Retrospective cohort analysis was performed on a consecutive series of patients who received mTHA and fluoroscopy-based RA-THA. The average amount of postoperative narcotics in morphine milligram equivalents (MME) given to each cohort was compared, including during the in-hospital and post-discharge periods. Analyses were performed on the overall cohort, as well as stratified by opioid-naïve and opioid-tolerant patients. RESULTS: The RA-THA cohort had significantly lower total postoperative narcotic use compared to the mTHA cohort (103.7 vs. 127.8 MME; P < 0.05). This difference was similarly seen amongst opioid-tolerant patients (123.6 vs. 181.3 MME; P < 0.05). The RA-THA cohort had lower total in-hospital narcotics use compared to the mTHA cohort (42.3 vs. 66.4 MME; P < 0.05), consistent across opioid-naïve and opioid-tolerant patients. No differences were seen in post-discharge opioid use between groups. CONCLUSIONS: Fluoroscopy-based RA-THA is associated with lower postoperative opioid use, including during the immediate perioperative period, when compared to manual techniques. This may have importance in rapid recovery protocols and mitigating episode burden of care.

7.
J Robot Surg ; 17(6): 2841-2847, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37770721

RESUMEN

Robotic-assisted total hip arthroplasty (THA) using a computerized-tomography (CT) based workflow increases surgical time relative to traditional manual technique. The purpose of this investigation was to compare the intra-operative efficiencies of two robotic THA systems: a fluoroscopy-based platform (FL-RTHA) and a contemporary, CT-based (CT-RTHA) platform. A review of 107 consecutive FL-RTHA and 159 CT-RTHA primary, direct anterior approach (DAA) THA procedures was conducted. All cases were performed by one of two surgeons operating at the same institution, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Primary outcome variables included averages and consistencies (variances) for surgical times and operating room (OR) times. A secondary outcome was to quantify the duration of robot-active phases in the FL-RTHA workflow. The FL-RTHA cohort experienced shorter surgical times (38.71 min ± 7.00 vs. 75.33 min ± 11.38; p < 0.001) and OR times (101.35 min ± 12.22 vs. 156.74 min ± 17.79; p < 0.001) compared to the CT-RTHA cohort. Surgical times and OR times were both more consistent in the FL-RTHA cohort compared to the CT-RTHA cohort (p < 0.001). Patients who underwent DAA THA with the assistance of a fluoroscopy-based robotic system experienced shorter and more consistent surgical times and OR times compared to patients who underwent similar DAA THA procedures with a contemporary, CT-based robotic platform.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Fluoroscopía , Tomografía Computarizada por Rayos X , Estudios Retrospectivos
8.
Int J Med Robot ; : e2582, 2023 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-37776329

RESUMEN

BACKGROUND: The purpose of this study was to assess the cost-effectiveness of a novel, fluoroscopy-based robotic-assisted total hip arthroplasty (RA-THA) system compared to a manual unassisted technique (mTHA) up to 5 years post-operatively. METHODS: A Markov model was constructed to compare the cost-effectiveness of RA-THA and mTHA. Cost-effectiveness was defined as an Incremental Cost-Effectiveness Ratio (ICER) <$50 000 or $100 000 per Quality Adjusted Life Year (QALY). RESULTS: RA-THA patients experienced lower costs compared to mTHA patients at 1 year ($20 865.12 ± 9897.52 vs. $21 660.86 ± 9909.15; p < 0.001) and 5 years ($23 124.57 ± 10 045.48 vs. $25 756.42 ± 10 091.84; p < 0.001) post-operatively. RA-THA patients also accrued more QALYs (1-year: 0.901 ± 0.117 vs. 0.888 ± 0.114; p < 0.001; 5-years: 4.455 ± 0.563 vs. 4.384 ± 0.537 p < 0.001). Overall, RA-THA was cost-effective (1-year ICER: $-61 210.77; 5-year ICER: $-37 068.31). CONCLUSIONS: The novel, fluoroscopy-based RA-THA system demonstrated cost-effectiveness when compared to manual unassisted THA.

9.
J Robot Surg ; 17(5): 2073-2079, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37209355

RESUMEN

Accurate acetabular cup position remains a persistent challenge in total hip arthroplasty (THA). Studies investigating the early outcomes of robotic-assisted THA (RA-THA) systems have shown improved cup placement compared to manual THA (mTHA) approaches, however, contemporary robotic platforms are reliant on pre-operative CT imaging. The goal of this study was to analyze the accuracy of a novel, fluoroscopy-based RA-THA system compared to an unassisted mTHA approach and determine the effect of the robotic system on operative time. We performed a retrospective cohort analysis on a consecutive series of 198 patients who received mTHA and RA-THA between March 2021 and July 2022. The primary outcome of interest was the accuracy of acetabular component placement, defined by average cup inclination and anteversion. Secondary outcomes included the proportion of acetabular cups positioned within the Lewinnek safe zone, operative time, and overall room time. The RA-THA group demonstrated significantly higher accuracy of acetabular anteversion to target compared to the manual group (18.5 vs. 21.7˚; p < 0.001), and had a significantly greater proportion of acetabular cups placed within the Lewinnek safe zone (81.6 vs. 59.0%; p < 0.001). The RA-THA cohort had longer operative times compared to mTHA group (39.0 vs. 35.3 min; p = 0.003), but no difference was seen in total operating room time (101.2 vs. 101.2 min; p = 0.982). This study demonstrates that the use of a novel, fluoroscopy-based, pin-less THA robotic platform increased the accuracy of acetabular cup placement, including a 22.6% improvement in safe zone placement, compared to mTHA approach, with no increase in overall case time.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Fluoroscopía
11.
Int J Med Robot ; 19(4): e2518, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37058696

RESUMEN

BACKGROUND: Adoption of robotic-assisted total hip arthroplasty (RA-THA) systems can improve the accuracy of acetabular cup placement, but no group has reported the learning curve of novel, fluoroscopy-based RA-THA systems. METHODS: A learning-curve cumulative summation (LC-CUSUM) analysis was performed on a consecutive series of the first 100 patients who received fluoroscopy-based RA-THA by the study surgeon. Operative times and specific robotic timepoints were compared between learning and proficiency phases. RESULTS: Implementation of fluoroscopy-based RA-THA was associated with a learning curve of 12 cases. A 6-min increase in operative time was seen during the learning phase compared to the proficiency phase (44.3 ± 4.4 vs. 38.0 ± 7.1 min; p < 0.001), with a 3-min longer robotic cup impaction sequence during the learning phase (7.8 ± 1.9 vs. 4.8 ± 1.3 min; p < 0.001). CONCLUSION: Adoption of fluoroscopy-based RA-THA is associated with a brief learning curve of 12 cases, with the most significant improvements in surgical efficiency realised during acetabular cup placement.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Procedimientos Quirúrgicos Robotizados , Humanos , Curva de Aprendizaje , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Fluoroscopía , Estudios Retrospectivos
12.
J Robot Surg ; 17(4): 1561-1567, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36913058

RESUMEN

Accurate and precise positioning of the acetabular cup remains a prevalent challenge in total hip arthroplasty (THA). Robotic assistance for THA has increased over the past decade due to the potential to improve the accuracy of implant placement. However, a common criticism of existing robotic systems is the requirement for preoperative computerized tomography (CT) scans. This additional imaging increases patient radiation exposure, as well as cost, and requires pin placement during surgery. The goal of this study was to analyze the radiation burden associated with a novel, CT-free robotic THA system compared to an unassisted manual THA approach (n = 100/arm). On average, the study cohort had a higher number of fluoroscopic images captured (7.5 vs. 4.3 images; p < 0.001), radiation dose (3.0 vs. 1.0 mGy; p < 0.001), and a longer duration of radiation exposure (18.8 vs. 6.3 s; p < 0.001), per procedure, than the control group. Additionally, no learning curve was detected by CUSUM analysis with respect to the number of fluoroscopic images taken during the adoption of the robotic THA system. While statistically significant, in comparison to published literature, the radiation exposure of the CT-free robotic THA system was comparable to that of unassisted manual THA approach and less than that of CT-based robotic approaches. Thus, the novel CT-free robotic system likely poses no clinically significant increase in radiation exposure to the patient compared to manual approaches.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Exposición a la Radiación , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios de Casos y Controles
13.
Nat Commun ; 13(1): 604, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35105861

RESUMEN

The role of PPM1D mutations in de novo gliomagenesis has not been systematically explored. Here we analyze whole genome sequences of 170 pediatric high-grade gliomas and find that truncating mutations in PPM1D that increase the stability of its phosphatase are clonal driver events in 11% of Diffuse Midline Gliomas (DMGs) and are enriched in primary pontine tumors. Through the development of DMG mouse models, we show that PPM1D mutations potentiate gliomagenesis and that PPM1D phosphatase activity is required for in vivo oncogenesis. Finally, we apply integrative phosphoproteomic and functional genomics assays and find that oncogenic effects of PPM1D truncation converge on regulators of cell cycle, DNA damage response, and p53 pathways, revealing therapeutic vulnerabilities including MDM2 inhibition.


Asunto(s)
Glioma/genética , Mutación , Oncogenes/genética , Proteína Fosfatasa 2C/genética , Adolescente , Adulto , Animales , Neoplasias del Tronco Encefálico/genética , Carcinogénesis/genética , Ciclo Celular , Niño , Preescolar , Daño del ADN , Modelos Animales de Enfermedad , Femenino , Células HEK293 , Humanos , Lactante , Masculino , Ratones , Proteínas Proto-Oncogénicas c-mdm2 , Transcriptoma , Proteína p53 Supresora de Tumor/genética , Adulto Joven
14.
Nat Commun ; 10(1): 2400, 2019 06 03.
Artículo en Inglés | MEDLINE | ID: mdl-31160565

RESUMEN

BET-bromodomain inhibition (BETi) has shown pre-clinical promise for MYC-amplified medulloblastoma. However, the mechanisms for its action, and ultimately for resistance, have not been fully defined. Here, using a combination of expression profiling, genome-scale CRISPR/Cas9-mediated loss of function and ORF/cDNA driven rescue screens, and cell-based models of spontaneous resistance, we identify bHLH/homeobox transcription factors and cell-cycle regulators as key genes mediating BETi's response and resistance. Cells that acquire drug tolerance exhibit a more neuronally differentiated cell-state and expression of lineage-specific bHLH/homeobox transcription factors. However, they do not terminally differentiate, maintain expression of CCND2, and continue to cycle through S-phase. Moreover, CDK4/CDK6 inhibition delays acquisition of resistance. Therefore, our data provide insights about the mechanisms underlying BETi effects and the appearance of resistance and support the therapeutic use of combined cell-cycle inhibitors with BETi in MYC-amplified medulloblastoma.


Asunto(s)
Azepinas/farmacología , Ciclo Celular/efectos de los fármacos , Neoplasias Cerebelosas/tratamiento farmacológico , Meduloblastoma/tratamiento farmacológico , Neurogénesis/efectos de los fármacos , Proteínas/antagonistas & inhibidores , Triazoles/farmacología , Animales , Factores de Transcripción con Motivo Hélice-Asa-Hélice Básico/efectos de los fármacos , Factores de Transcripción con Motivo Hélice-Asa-Hélice Básico/metabolismo , Sistemas CRISPR-Cas , Proteínas de Ciclo Celular/efectos de los fármacos , Proteínas de Ciclo Celular/metabolismo , Línea Celular Tumoral , Linaje de la Célula , Neoplasias Cerebelosas/genética , Ciclina D2/efectos de los fármacos , Ciclina D2/metabolismo , Quinasa 4 Dependiente de la Ciclina/antagonistas & inhibidores , Quinasa 6 Dependiente de la Ciclina/antagonistas & inhibidores , Resistencia a Antineoplásicos , Perfilación de la Expresión Génica , Humanos , Meduloblastoma/genética , Ratones , Células-Madre Neurales/efectos de los fármacos , Células-Madre Neurales/metabolismo , Proteínas Proto-Oncogénicas c-myc/genética , Fase S/efectos de los fármacos
15.
Front Mol Neurosci ; 9: 148, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28105003

RESUMEN

Optomotor behavior represents a stereotyped locomotor response to visual motion that is found in both vertebrate and invertebrate models. The Fly Stampede assay was developed to study an optomotor response in freely walking populations of Drosophila. Here we share optimized assay designs and software for production of a modified stampede assay that can be used for genetic screens, and improved tracking outputs for understanding behavioral parameters of visual-motion responses and arousal state of individual animals. Arousal state influences behavioral performance in the stampede assay. As proof of principle experiments we show parametric modulation of visual stimuli and startle stimuli in both wildtype and mutant flies for the type I family dopamine receptor Dop1R1 (DopR). DopR mutants are hyperactive and perform poorly in the stampede assay, suggesting a potential role in visual perception and/or arousal. The stampede assay creates an efficient platform for rapid screening of mutant animals or circuit manipulations for investigating attentional processes in Drosophila.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...