Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Med Phys ; 51(5): 3165-3172, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38588484

RESUMEN

BACKGROUND: Simulated error training is a method to practice error detection in situations where the occurrence of error is low. Such is the case for the physics plan and chart review where a physicist may check several plans before encountering a significant problem. By simulating potentially hazardous errors, physicists can become familiar with how they manifest and learn from mistakes made during a simulated plan review. PURPOSE: The purpose of this project was to develop a series of training datasets that allows medical physicists and trainees to practice plan and chart reviews in a way that is familiar and accessible, and to provide exposure to the various failure modes (FMs) encountered in clinical scenarios. METHODS: A series of training datasets have been developed that include a variety of embedded errors based on the risk-assessment performed by American Association of Physicists in Medicine (AAPM) Task Group 275 for the physics plan and chart review. The training datasets comprise documentation, screen shots, and digital content derived from common treatment planning and radiation oncology information systems and are available via the Cloud-based platform ProKnow. RESULTS: Overall, 20 datasets have been created incorporating various software systems (Mosaiq, ARIA, Eclipse, RayStation, Pinnacle) and delivery techniques. A total of 110 errors representing 50 different FMs were embedded with the 20 datasets. The project was piloted at the 2021 AAPM Annual Meeting in a workshop where participants had the opportunity to review cases and answer survey questions related to errors they detected and their perception of the project's efficacy. In general, attendees detected higher-priority FMs at a higher rate, though no correlation was found between detection rate and the detectability of the FMs. Familiarity with a given system appeared to play a role in detecting errors, specifically when related to missing information at different locations within a given software system. Overall, 96% of respondents either agreed or strongly agreed that the ProKnow portal and training datasets were effective as a training tool, and 75% of respondents agreed or strongly agreed that they planned to use the tool at their local institution. CONCLUSIONS: The datasets and digital platform provide a standardized and accessible tool for training, performance assessment, and continuing education regarding the physics plan and chart review. Work is ongoing to expand the project to include more modalities, radiation oncology treatment planning and information systems, and FMs based on emerging techniques such as auto-contouring and auto-planning.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Planificación de la Radioterapia Asistida por Computador/métodos , Física Sanitaria/educación , Humanos , Errores Médicos/prevención & control
2.
J Appl Clin Med Phys ; 24(10): e14151, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37708093

RESUMEN

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. While must is the term to be used in the guidelines, if an entity that adopts the guideline has shall as the preferred term, the AAPM considers that must and shall have the same meaning. Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances.


Asunto(s)
Física Sanitaria , Oncología por Radiación , Humanos , Estados Unidos , Física Sanitaria/educación , Sociedades , Revisión por Pares
3.
J Appl Clin Med Phys ; 24(10): e14130, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37646429

RESUMEN

Concept inventories are multiple choice exams designed with the intention to test core concepts on specific subjects and evaluate common misconceptions. These tests serve as a useful tool in the classroom to assess value added by the instructor's educational methods and to better understand how students learn. They can provide educators with a method to evaluate their current teaching strategies and to make modifications that enhance student learning and ultimately elevate the quality of medical physics education. The use of concept inventories in introductory college physics courses revealed important gaps in conceptual understanding of physics by undergraduate students and motivated a shift of physics teaching towards more effective methods, such as active learning techniques. The goal of this review is to introduce medical physicists to concept inventories as educational evaluation tools and discuss potential applications to medical physics education by development through multi-institutional collaboration.

5.
J Appl Clin Med Phys ; 20(9): 157-162, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31355990

RESUMEN

PURPOSE: Previous studies suggest that within radiation oncology, medical physicists (MP) experience high workloads. Little is known about how MPs use social support (SS) in times of stress. METHODS: In collaboration with the Workgroup on Prevention of Medical Error, the American Association of Physicists in Medicine administered this Human Investigation Committee (HIC) approved email survey to 8566 members. Respondents were considered likely to seek SS if they answered (probably/definitely would) and unlikely to seek support if they answered (probably/definitely would not). Logistic regression was applied to determine associations between demographic factors and willingness to seek support as well as perception of barriers. RESULTS: One thousand two hundred and ninety-seven members (15.1%) accessed and gave consent for the survey. One thousand and one (11.7%) respondents answered all relevant questions. Respondents were predominantly male (69.1%), MP in radiation oncology (81.8%), private practice (51.6%), with practice duration> 10 yr (60.2%). MPs were likely to seek SS for personal physical illness (78.63%), involvement in a medical error (73.94%) or adverse patient outcome (75.17%). MPs sought SS in the setting of personal fatigue (33.2%) or burnout (44.3%). Barriers to seeking SS were lack of time (80.3%), and uncertainty about whom to access (70.7%). MPs responded that they would be most likely to seek support from an equally experienced medical physicist colleague (81.0%). Most MPs (67.0%) identified as having experienced stressors, with serious family illness (35.2%), or burnout (32.8%) being most common. Factors associated with MPs unwillingness to seek SS for medical error included> 20 yr in practice (vs still in training - OR 0.30, P = 0.015), and male gender (OR 0.60, P = 0.003). Male gender was associated with the lowest willingness to seek support (OR 2.10, P = 0.0001), but also with fewer perceived barriers (OR 1.60, P = 0.0075). CONCLUSION: Willingness to seek SS is demonstrated, and MPs want colleagues to provide support. Given these results, peer support could be considered among MPs.


Asunto(s)
Agotamiento Profesional/psicología , Física Sanitaria , Mentores/estadística & datos numéricos , Evaluación de Necesidades/estadística & datos numéricos , Grupo Paritario , Médicos/psicología , Apoyo Social , Estrés Psicológico/prevención & control , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios
6.
Phys Med ; 40: 33-41, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28712717

RESUMEN

The purpose of this study is to evaluate the clinical efficacy of both step-and-shoot IMRT and 3D-Conformal Radiation Therapy modalities (CRT) in treating prostate cancer using radiobiological measures. Another aim was to estimate the risks for developing secondary malignancies in bladder and rectum due to radiotherapy from the corresponding modalities. The treatment plans of ten prostate cancer patients were developed using IMRT and CRT. For the IMRT plans, two beam energies and two treatment protocols were used (the RTOG 0415 and a most restrictive one proposed by Fox Chase Cancer Center (FCCC)). For the evaluation of these plans, the complication-free tumor control probability, the total probability of injury, the total probability of control/benefit, and the biologically effective uniform dose were employed. Furthermore, based on the dosimetric data of IMRT and CRT, the risk for secondary malignancies was calculated for bladder and rectum. The average risk for secondary malignancy was lower for the bladder (0.37%) compared to the rectum (0.81%) based on all the treatment plans of the ten prostate cancer patients. The highest average risk for secondary malignancy for bladder and rectum was for the CRT-6X modality (0.46% and 1.12%, respectively) and the lowest was for the IMRT RTOG-18X modality (0.33% and 0.56%, respectively). The ≥ Grade 2 LENT/SOMA response probability was lower for the bladder than for the rectum in all the plans. For the bladder the highest average value was for the IMRT RTOG-18X (0.9%) and the lowest was for the CRT-18X modality (0.1%). For the rectum, the highest average value was for the IMRT RTOG-6X (11.9%) and the lowest was for the IMRT FCCC-18X modality (2.2%). By using radiobiological measures it is shown that the IMRT FCCC plans had the lowest risks for normal tissue complications, whereas the IMRT RTOG had the highest. Regarding the risk for secondary malignancies, the CRT plans showed the highest values for both bladder and rectum.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Protocolos Clínicos , Humanos , Masculino , Dosificación Radioterapéutica
7.
Lancet Oncol ; 15(9): 1027-38, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24980873

RESUMEN

BACKGROUND: Malignant tumours arising within the nasal cavity and paranasal sinuses are rare and composed of several histological types, rendering controlled clinical trials to establish the best treatment impractical. We undertook a systematic review and meta-analysis to compare the clinical outcomes of patients treated with charged particle therapy with those of individuals receiving photon therapy. METHODS: We identified studies of nasal cavity and paranasal sinus tumours through searches of databases including Embase, Medline, Scopus, and the Cochrane Collaboration. We included treatment-naive cohorts (both primary and adjuvant radiation therapy) and those with recurrent disease. Primary outcomes of interest were overall survival, disease-free survival, and locoregional control, at 5 years and at longest follow-up. We used random-effect models to pool outcomes across studies and compared event rates of combined outcomes for charged particle therapy and photon therapy using an interaction test. FINDINGS: 43 cohorts from 41 non-comparative observational studies were included. Median follow-up for the charged particle therapy group was 38 months (range 5-73) and for the photon therapy group was 40 months (14-97). Pooled overall survival was significantly higher at 5 years for charged particle therapy than for photon therapy (relative risk 1·51, 95% CI 1·14-1·99; p=0·0038) and at longest follow-up (1·27, 1·01-1·59; p=0·037). At 5 years, disease-free survival was significantly higher for charged particle therapy than for photon therapy (1·93, 1·36-2·75, p=0·0003) but, at longest follow-up, this event rate did not differ between groups (1·51, 1·00-2·30; p=0·052). Locoregional control did not differ between treatment groups at 5 years (1·06, 0·68-1·67; p=0·79) but it was higher for charged particle therapy than for photon therapy at longest follow-up (1·18, 1·01-1·37; p=0·031). A subgroup analysis comparing proton beam therapy with intensity-modulated radiation therapy showed significantly higher disease-free survival at 5 years (relative risk 1·44, 95% CI 1·01-2·05; p=0·045) and locoregional control at longest follow-up (1·26, 1·05-1·51; p=0·011). INTERPRETATION: Compared with photon therapy, charged particle therapy could be associated with better outcomes for patients with malignant diseases of the nasal cavity and paranasal sinuses. Prospective studies emphasising collection of patient-reported and functional outcomes are strongly encouraged. FUNDING: Mayo Foundation for Medical Education and Research.


Asunto(s)
Partículas alfa/uso terapéutico , Braquiterapia/métodos , Neoplasias Nasales/mortalidad , Neoplasias Nasales/radioterapia , Fotones/uso terapéutico , Adulto , Anciano , Estudios de Cohortes , Supervivencia sin Enfermedad , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Nasales/patología , Neoplasias de los Senos Paranasales/tratamiento farmacológico , Neoplasias de los Senos Paranasales/mortalidad , Neoplasias de los Senos Paranasales/patología , Pronóstico , Dosis de Radiación , Medición de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
8.
Med Phys ; 37(9): 4854-60, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20964202

RESUMEN

PURPOSE: Intensity modulated radiation therapy (IMRT) treatment delivery requires higher precision than conventional 3D treatment delivery because of the sensitivity of the resulting dose to small geometric misalignment of the modulated beamlets. The chosen treatment delivery technique will affect the treatment precision in different ways, based on the characteristics of the delivery method. Delivery using a multileaf collimator (MLC) can reduce treatment time and therapist workload, but typically requires a greater number of monitor units and the fields are prone to both systematic and random leaf positioning errors. An alternative to MLC-based fields, patient specific brass compensators, do not suffer from these leaf positioning errors. In our study, we set out to investigate which delivery method will provide the highest levels of dosimetric reproducibility and the minimum amount of interfraction variability. METHODS: In our study, a seven field IMRT plan for a head and neck treatment was created using the Pinnacle3 treatment planning system and the intensity maps for each field were obtained. The intensity maps of the fields were delivered with a Varian 2100C/D linear accelerator, using solid compensators and sliding window (SW) and step-and-shoot (SS) MLC segments. Three fields were selected from the seven-beam IMRT plan for comparison. Analysis was carried out using the MatriXX ion chamber array, radiochromic film, and Varian dynalog files. RESULTS: Our results show that the error in MLC leaf positioning has no gantry angle dependence. The compensator and SW deliveries showed excellent agreement, even when stricter than usual gamma criteria were applied. However, we noted that under these strict conditions, the SS field had at least ten times more pixels out of range than did the compensators. When using step-and-shoot MLC fields, it was observed that the increase in dose rate or the increase of MU/segment degrades the quality of the plan. Analysis of the dynalog files showed that while each individual field had its own propensity for error, all fields showed the same trend: a greater percentage of time the leaves are out of position as dose rate increases, MUs decrease, or both. CONCLUSIONS: The compensator-based field and both types of MLC-based fields have MatriXX results that are within the clinically acceptable tolerance of 3% dose difference and 2 mm DTA. However, when the criteria are tightened, it becomes evident that the compensators have a definite advantage over their comparable MLC-based competitors in terms of interfraction reproducibility. Fewer monitor units are required to deliver each portal, potentially improving patient outcomes and reducing unwanted side effects to both patients and therapists. In centers without MLC, compensators represent a simple and cost effective way to offer patients state of the art treatment. Based on the results of this study, compensator-based IMRT is a reliable, viable option for use in clinics both with and without MLC-equipped linacs.


Asunto(s)
Fraccionamiento de la Dosis de Radiación , Radioterapia de Intensidad Modulada/métodos , Gravitación , Radiometría , Reproducibilidad de los Resultados
9.
J Appl Clin Med Phys ; 11(3): 3163, 2010 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-20717082

RESUMEN

In this paper, we present the dosimetric characteristics of a commercially-produced universal GRID block for spatially fractioned radiation therapy. The dosimetric properties of the GRID block were evaluated. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a solid water phantom to determine the relative output of the GRID block as well as its spatial dosimetric characteristics. The surface dose under the block and at the openings was measured using ultra thin TLDs. After introducing the GRID block into the treatment planning system, a treatment plan was created using the GRID block and also by creating a GRID pattern using the multi-leaf collimator. The percent depth doses measured with film showed that there is a shift of the dmax towards shallower depths for both energies (6 MV and 18 MV) under investigation. It was observed that the skin dose at the GRID openings was higher than the corresponding open field by a factor as high as 50% for both photon energies. The profiles showed the transmission under the block was in the order of 15-20% for 6 MV and 30% for 18 MV. The MUs calculated for a real patient using the block were about 80% less than the corresponding MUs for the same plan using the multileaf collimator to define the GRID. Based on this investigation, this brass GRID compensator is a viable alternative to other solid compensators or MLC-based fields currently in use. Its ease of creation and use give it decided advantages. Its ability to be created once and used for multiple patients (by varying the collimation of the linear accelerator jaws) makes it attractive from a cost perspective. We believe this compensator can be put to clinical use, and will allow more centers to offer GRID therapy to their patients.


Asunto(s)
Fraccionamiento de la Dosis de Radiación , Radiometría/instrumentación , Planificación de la Radioterapia Asistida por Computador , Radioterapia/instrumentación , Humanos , Aceleradores de Partículas , Radiometría/métodos , Radioterapia/métodos
10.
Appl Radiat Isot ; 67(9): 1629-37, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19369083

RESUMEN

In light of the increasing use of intensity modulated radiation therapy (IMRT) in modern radiotherapy practice, the use of a flattening filter may no longer be necessary. Commissioning data have been measured for a Varian 23EX linear accelerator with 6 and 18 MV photon energies without a flattening filter. Measurements collected for the commissioning of the linac included percent depth dose curves and profiles for field sizes ranging from 2 x 2 to 40 x 40 cm(2) as defined by the jaws and multileaf collimator. Machine total scatter factors were measured and calculated. Measurements were used to model the unflattened beams with the Pinnacle(3) treatment planning system. IMRT plans for prostate, lung, brain and head and neck cancer cases were generated using the flattening filter and flattening filter-free beams. From our results, no difference in the quality of the treatment plans between the flat and unflattened photon beams was noted. There was however a significant decrease in the number of monitor units required for unflattened beam treatment plans due to the increase in linac output-approximately two times and four times higher for the 6 and 18 MV, respectively.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Aceleradores de Partículas , Fotones , Planificación de la Radioterapia Asistida por Computador/instrumentación , Radioterapia de Intensidad Modulada/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...