Clin Chem ; 69(11): 1227-1237, 2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37725906

RESUMEN

It is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs). Using commutable EQAMs makes it possible to evaluate metrological traceability and/or equivalence of results between IVD-MDs. The criterion for assessing commutability of an EQAM between 2 IVD-MDs is that its result should be within the prediction interval limits based on the statistical distribution of the clinical sample results from the 2 IVD-MDs being compared. The width of the prediction interval is, among other things, dependent on the analytical performance characteristics of the IVD-MDs. A presupposition for using this criterion is that the differences in nonselectivity between the 2 IVD-MDs being compared are acceptable. An acceptable difference in nonselectivity should be small relative to the analytical performance specifications used in the external quality assessment scheme. The acceptable difference in nonselectivity is used to modify the prediction interval criterion for commutability assessment. The present report provides recommendations on how to establish a criterion for acceptable commutability for EQAMS, establish the difference in nonselectivity that can be accepted between IVD-MDs, and perform a commutability assessment. The report also contains examples for performing a commutability assessment of EQAMs.


Asunto(s)
Servicios de Laboratorio Clínico , Ensayos de Aptitud de Laboratorios , Humanos , Estándares de Referencia , Juego de Reactivos para Diagnóstico
2.
Clin Chem ; 69(9): 966-975, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37566391

RESUMEN

A secondary higher-order calibrator is required to be commutable with clinical samples to be suitable for use in the calibration hierarchy of an end-user clinical laboratory in vitro diagnostic medical device (IVD-MD). Commutability is a property of a reference material that means results for a reference material and for clinical samples have the same numeric relationship, within specified limits, across the measurement procedures for which the reference material is intended to be used. Procedures for assessing commutability have been described in the literature. This report provides recommendations for establishing a quantitative criterion to assess the commutability of a certified reference material (CRM). The criterion is the maximum allowable noncommutability bias (MANCB) that allows a CRM to be used as a calibrator in a calibration hierarchy for an IVD-MD without exceeding the maximum allowable combined standard uncertainty for a clinical sample result (umaxCS). Consequently, the MANCB is derived as a fraction of the umaxCS for the measurand. The suitability of an MANCB for practical use in a commutability assessment is determined by estimating the number of measurements of clinical samples and CRMs required based on the precision performance and nonselectivity for the measurand of the measurement procedures in the assessment. Guidance is also provided for evaluating indeterminate commutability conclusions and how to report results of a commutability assessment.

3.
Clin Chem Lab Med ; 61(10): 1719-1729, 2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37071928

RESUMEN

OBJECTIVES: The clinical use of soluble transferrin receptor (sTfR) as an iron status indicator is hindered by a lack of assay standardization and common reference ranges and decision thresholds. In 2009, the WHO and National Institute for Biological Standards and Controls (NIBSC) released a sTfR reference material (RM), 07/202, for assay standardization; however, a comprehensive, formal commutability study was not conducted. METHODS: This study evaluated the commutability of WHO 07/202 sTfR RM and human serum pools and the impacts of their use as common calibrators. Commutability was assessed for six different measurement procedures (MPs). Serum pools were prepared according to updated CLSI C37-A procedures (C37) or non-C37 procedures. The study design and analyses were based on Parts 2 and 3 of the 2018 IFCC Commutability in Metrological Traceability Working Group's Recommendations for Commutability Assessment. WHO 07/202 and serum pools were used for instrument/assay and mathematical recalibration, respectively, to determine if their use decreases inter-assay measurement variability for clinical samples. RESULTS: The WHO 07/202 RM dilutions were commutable for all 6 MPs assessed and, when used for instrument calibration, decreased inter-assay variability from 208 to 55.7 %. Non-C37 and C37 serum pools were commutable for all 6 MPs assessed and decreased inter-assay variability from 208 to 13.8 % and 4.6 %, respectively, when used for mathematical recalibration. CONCLUSIONS: All materials evaluated, when used as common calibrators, substantially decreased inter-assay sTfR measurement variability. MP calibration to non-C37 and C37 serum pools may reduce the sTfR IMPBR to a greater extent than WHO 07/202 RM.


Asunto(s)
Receptores de Transferrina , Suero , Humanos , Estándares de Referencia , Calibración , Organización Mundial de la Salud
4.
J Prim Care Community Health ; 14: 21501319231166921, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37073905

RESUMEN

Physician burnout has been increasing in the United States, especially in primary care, and the use of Electronic Health Records (EHRs) is a prominent contributor. This review article summarizes findings from a PubMed literature search that shows the significant contributors to EHR-related burnout may be documentation and clerical burdens, complex usability, electronic messaging and inbox, cognitive load, and time demands. Documentation requirements have escalated and have inherently changed from paper-based records. Many clerical tasks have also shifted to become additional physician responsibilities. When considering factors of efficiency, effectiveness, and user satisfaction, EHRs overall have an inferior usability score when compared to other technologies. The volume and organization of data along with alerts and complex interfaces require a substantial cognitive load and result in cognitive fatigue. Patient interactions and work-life balances are negatively affected by the time requirements of EHR tasks during and after clinic hours. Patient portals and EHR messaging have created a separate source of patient care outside of face-to-face visits that is often unaccounted productivity and not reimbursable.


Asunto(s)
Agotamiento Profesional , Médicos , Humanos , Estados Unidos , Registros Electrónicos de Salud , Médicos/psicología , Agotamiento Profesional/epidemiología , Agotamiento Profesional/psicología , Documentación , Atención Primaria de Salud
5.
J Clin Med ; 12(5)2023 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-36902574

RESUMEN

While the Food and Drug Administration's black-box warnings caution against concurrent opioid and benzodiazepine (OPI-BZD) use, there is little guidance on how to deprescribe these medications. This scoping review analyzes the available opioid and/or benzodiazepine deprescribing strategies from the PubMed, EMBASE, Web of Science, Scopus, and Cochrane Library databases (01/1995-08/2020) and the gray literature. We identified 39 original research studies (opioids: n = 5, benzodiazepines: n = 31, concurrent use: n = 3) and 26 guidelines (opioids: n = 16, benzodiazepines: n = 11, concurrent use: n = 0). Among the three studies deprescribing concurrent use (success rates of 21-100%), two evaluated a 3-week rehabilitation program, and one assessed a 24-week primary care intervention for veterans. Initial opioid dose deprescribing rates ranged from (1) 10-20%/weekday followed by 2.5-10%/weekday over three weeks to (2) 10-25%/1-4 weeks. Initial benzodiazepine dose deprescribing rates ranged from (1) patient-specific reductions over three weeks to (2) 50% dose reduction for 2-4 weeks, followed by 2-8 weeks of dose maintenance and then a 25% reduction biweekly. Among the 26 guidelines identified, 22 highlighted the risks of co-prescribing OPI-BZD, and 4 provided conflicting recommendations on the OPI-BZD deprescribing sequence. Thirty-five states' websites provided resources for opioid deprescription and three states' websites had benzodiazepine deprescribing recommendations. Further studies are needed to better guide OPI-BZD deprescription.

6.
Clin Chem ; 69(3): 228-238, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36660772

RESUMEN

Equivalent results for the same measurand in clinical samples (CSs), measured using different end-user in-vitro diagnostic medical devices (IVD-MDs), are essential for the application of clinical practice guidelines for diagnosis, treatment, monitoring, or risk assessment. The International Organization for Standardization (ISO) document 17511:2020 specifies how to establish metrological traceability to the highest available reference system component to enable equivalent results among IVD-MDs. Commutability with CSs is an essential property of a reference material used as a calibrator in a calibration hierarchy. However, not all calibrators in a calibration hierarchy are required to be commutable; different calibration hierarchies have different requirements for which calibrators must be commutable with CSs. Because assessment of commutability is a substantial effort, it is therefore important to determine which calibrators need to be commutable when implementing a calibration hierarchy. We provide guidance on which calibrators must be commutable with CSs, when a correction for any noncommutability bias is appropriate, and when commutability of a calibrator with CSs is not required for various types of calibration hierarchies described in ISO 17511:2020.


Asunto(s)
Calibración , Humanos , Estándares de Referencia
7.
BMJ Case Rep ; 15(2)2022 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-35110278

RESUMEN

DiGeorge syndrome (DGS) is caused by a chromosomal microdeletion at 22q11.2 that results in impaired development of the pharyngeal pouch system. Patients with DGS may have developmental abnormalities of craniofacial structures, parathyroid glands, thymus and cardiac outflow tract. Doctors have been routinely testing for DGS in newborns with conotruncal cardiac anomalies since the late 1990s; before then, however, they relied on complex diagnostic criteria and the disease was often missed. Adults born with conotruncal defects before the late 1990s may have undiagnosed DGS. We present one such case: a 35-year-old woman with a cardiac diagnosis of tetralogy of Fallot and unilateral absence of a pulmonary arter who was found to have DGS. Identifying DGS in adults is important both for disease management and genetic counselling. Our case emphasises the importance of screening for DGS in adults who were born with conotruncal cardiac abnormalities before widespread neonatal testing became common.


Asunto(s)
Síndrome de DiGeorge , Cardiopatías Congénitas , Adulto , Deleción Cromosómica , Síndrome de DiGeorge/diagnóstico , Síndrome de DiGeorge/genética , Femenino , Corazón , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/genética , Humanos , Recién Nacido
8.
Curr Diab Rep ; 20(11): 59, 2020 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-33015726

RESUMEN

PURPOSE OF REVIEW: Nonalcoholic fatty liver disease (NAFLD) is an often unrecognized complication of type 2 diabetes (T2DM) associated with significant economic burden and poor long-term hepatic and extrahepatic outcomes. Our goal is to review evidence about the complex association between NAFLD and T2DM and highlight the potential for disease co-management with the available medications used for the treatment of diabetes. RECENT FINDINGS: A milieu of metabolic factors such as insulin resistance, glucotoxicity, and lipotoxicity, as well as genetics and other factors, contribute to the pathogenesis and co-existence of NAFLD with T2DM. The presence of T2DM in patients with NAFLD increases the risk of disease progression to steatohepatitis (NASH) and advanced fibrosis, cirrhosis, and even hepatocellular carcinoma. In addition to lifestyle modification, pioglitazone and glucagon-like peptide 1 receptor agonists (GLP-1RAs) both reduce the high cardiovascular risk and improve liver histology in patients with NAFLD. Sodium-glucose cotransporter (SGLT-2) inhibitors also appear to reverse metabolic abnormalities as well as liver disease in NAFLD, but their impact on liver histology has not been fully established. Lastly, metformin, dipeptidyl dipetidase-4 (DPP-4) inhibitors, and insulin appear to have modest to no effect on modifying the natural history of NAFLD. Early recognition of NAFLD and monitoring for NASH with advanced liver fibrosis in patients with T2DM are crucial. The presence of NASH in a patient with T2DM should call for taking advantage of antidiabetic medications with proven efficacy to improve cardiometabolic health and prevent liver disease progression.


Asunto(s)
Diabetes Mellitus Tipo 2 , Resistencia a la Insulina , Enfermedad del Hígado Graso no Alcohólico , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Enfermedad del Hígado Graso no Alcohólico/tratamiento farmacológico , Pioglitazona
9.
Clin Chem Lab Med ; 58(11): 1829-1835, 2020 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-32883061

RESUMEN

Background Clinical laboratories use internal quality control (QC) data to calculate standard deviation (SD) and coefficient of variation (CV) to estimate uncertainty of results and to interpret QC results. We examined the influence of different instruments, and QC and reagent lots on the CV calculated from QC data. Methods Results for BioRad Multiqual frozen liquid QC samples over a 2-year interval were partitioned by QC and reagent lots. The mean and CV were calculated for each partition for each of three Abbott Architect c8000 instruments for measuring serum alanine amino transferase (ALT), creatinine (enzymatic), glucose and sodium. Results CVs differed among partitions and instruments for two QC levels by 5.8- and 3.3-fold for ALT, by 4.7- and 2.1-fold for creatinine, by 2.0- and 2.6-fold for glucose, and by 2.1- and 2.0-fold for sodium. Pooled CVs for two QC levels varied among instruments by 1.78- and 1.11-fold for ALT, by 1.63- and 1.11-fold for creatinine, by 1.08- and 1.06-fold for glucose, and by 1.24- and 1.31-fold for sodium. Conclusions The CVs from QC data varied substantially among QC and reagent lots and for different identical specification instruments. The CV used to estimate uncertainty for a measurement result or as the basis for interpreting individual QC results must be derived over a sufficient time interval to obtain a pooled CV that represents "typical" performance of a measuring system. An estimate of uncertainty provided to users of laboratory results will itself have uncertainty that can influence medical decisions.


Asunto(s)
Técnicas de Laboratorio Clínico/estadística & datos numéricos , Indicadores y Reactivos/química , Alanina Transaminasa/sangre , Creatinina/análisis , Glucosa/análisis , Humanos , Control de Calidad , Sodio/análisis , Factores de Tiempo , Incertidumbre
10.
J Clin Med ; 9(7)2020 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-32708920

RESUMEN

Pharmacogenetic testing (PGT) is increasingly being used as a tool to guide clinical decisions. This article describes the development of an outpatient, pharmacist-led, pharmacogenetics consult clinic within internal medicine, its workflow, and early results, along with successes and challenges. A pharmacogenetics-trained pharmacist encouraged primary care physicians (PCPs) to refer patients who were experiencing side effects/ineffectiveness from certain antidepressants, opioids, and/or proton pump inhibitors. In clinic, the pharmacist confirmed the need for and ordered CYP2C19 and/or CYP2D6 testing, provided evidence-based pharmacogenetic recommendations to PCPs, and educated PCPs and patients on the results. Operational and clinical metrics were analyzed. In two years, 91 referred patients were seen in clinic (mean age 57, 67% women, 91% European-American). Of patients who received PGT, 77% had at least one CYP2C19 and/or CYP2D6 phenotype that would make conventional prescribing unfavorable. Recommendations suggested that physicians change a medication/dose for 59% of patients; excluding two patients lost to follow-up, 87% of recommendations were accepted. Challenges included PGT reimbursement and referral maintenance. High frequency of actionable results suggests physician education on who to refer was successful and illustrates the potential to reduce trial-and-error prescribing. High recommendation acceptance rate demonstrates the pharmacist's effectiveness in providing genotype-guided recommendations, emphasizing a successful pharmacist-physician collaboration.

11.
Clin Chem ; 66(6): 769-778, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32335671

RESUMEN

Establishing metrological traceability to an assigned value of a matrix-based certified reference material (CRM) that has been validated to be commutable among available end-user measurement procedures (MPs) is central to producing equivalent results for the measurand in clinical samples (CSs) irrespective of the clinical laboratory MPs used. When a CRM is not commutable with CSs, the bias due to noncommutability will be propagated to the CS results causing incorrect metrological traceability to the CRM and nonequivalent CS results among different MPs. In a commutability assessment, a conclusion that a CRM is commutable or noncommutable for use with a specific MP is made when the difference in bias between the CRM and CSs meets or does not meet a criterion for that specific MP when compared to other MPs. A conclusion regarding commutability or noncommutability requires that the magnitude of the difference in bias observed in the commutability assessment remains unchanged over time. This conclusion requires the CRM to be stable and no substantive changes in the MPs. These conditions should be periodically reverified. If an available CRM is determined to be noncommutable for a specific MP, that CRM can be used in the calibration hierarchy for that MP when an appropriately validated MP-specific correction for the noncommutability bias is included. We describe with examples how a MP-specific correction and its uncertainty can be developed and applied in a calibration hierarchy to achieve metrological traceability of results for CSs to the CRM's assigned value.


Asunto(s)
Sesgo , Guías como Asunto , Juego de Reactivos para Diagnóstico/normas , Calibración , Humanos , Estándares de Referencia
12.
Am J Med ; 133(5): 536-543, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32017891

RESUMEN

Nonalcoholic fatty liver disease (NAFLD) is the most common chronic liver disease in the United States and is soon to be the leading cause of liver transplantation. Patients at the greatest risk are those with obesity and type 2 diabetes mellitus. In 2019 the American Diabetes Association guidelines called, for the first time, for clinicians to screen for steatohepatitis and fibrosis all patients with type 2 diabetes and liver steatosis or abnormal plasma aminotransferases. This requires primary care physicians to be aware of key aspects related to the diagnosis and treatment of NAFLD, as well as to when to refer to a specialist. Unfortunately, there is still significant medical inertia as clinicians remain unaware of its high morbidity/mortality. Early diagnosis in the primary care setting is critical to prevent progression to end-stage liver disease. Patients with NAFLD are also at a higher risk of developing type 2 diabetes mellitus and cardiovascular disease. Despite general perception to the contrary, weight loss by lifestyle intervention or bariatric surgery and several pharmacological treatments (eg, vitamin E in nondiabetics, pioglitazone or glucagon-like peptide 1 receptor agonists in patients with or without diabetes) can often be successful to reverse steatohepatitis and prevent disease progression.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Atención Primaria de Salud , Humanos , Enfermedad del Hígado Graso no Alcohólico/etiología , Enfermedad del Hígado Graso no Alcohólico/terapia , Atención Primaria de Salud/métodos , Factores de Riesgo
13.
Clin Chem ; 64(3): 447-454, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29348163

RESUMEN

Commutability is a property of a reference material (RM) that relates to the closeness of agreement between results for an RM and results for clinical samples (CSs) when measured by ≥2 measurement procedures (MPs). Commutability of RMs used in a calibration traceability scheme is an essential property for them to be fit for purpose. Similarly, commutability of trueness controls or external quality assessment samples is essential when those materials are used to assess trueness of results for CSs. This report is part 1 of a 3-part series describing how to assess commutability of RMs. Part 1 defines commutability and addresses critical components of the experimental design for commutability assessment, including selection of individual CSs, use of pooled CSs, qualification of MPs for inclusion, establishing criteria for the determination that an RM is commutable, generalization of commutability conclusions to future measurements made with the MPs included in the assessment, and information regarding commutability to be included in the certificate for an RM. Parts 2 and 3 in the series present 2 different statistical approaches to commutability assessment that use fixed criteria related to the medical decisions that will be made using the laboratory test results.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Calibración , Humanos , Estándares de Referencia
14.
Clin Chem ; 64(3): 465-474, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29348164

RESUMEN

A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator based on its ability to fulfill its intended use in a calibration traceability scheme to produce equivalent clinical sample (CS) results among different measurement procedures (MPs) for the same measurand. Three sources of systematic error are elucidated in the context of creating the calibration model for translating MP signals to measurand amounts: calibration fit, calibrator level trueness, and commutability. An example set of 40 CS results from 7 MPs is used to illustrate estimation of bias and variability for each MP. The candidate RM is then used to recalibrate each MP, and its effectiveness in reducing the systematic error among the MPs within an acceptable level of equivalence based on medical requirements confirms its commutability for those MPs. The RM is declared noncommutable for MPs for which, after recalibration, the CS results do not agree with those from other MPs. When a lack of agreement is found, other potential causes, including lack of calibration fit, should be investigated before concluding the RM is noncommutable. The RM is considered fit for purpose for those MPs where commutability is demonstrated.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Estándares de Referencia , Sesgo , Calibración , Humanos
15.
Clin Chem ; 64(3): 455-464, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29348165

RESUMEN

A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator, trueness control, or external quality assessment sample based on the difference in bias between an RM and clinical samples (CSs) measured using 2 different measurement procedures (MPs). This difference in bias is compared with a criterion based on a medically relevant difference between an RM and CS results to make a conclusion regarding commutability. When more than 2 MPs are included, the commutability is assessed pairwise for all combinations of 2 MPs. This approach allows the same criterion to be used for all combinations of MPs included in the assessment. The assessment is based on an error model that allows estimation of various random and systematic sources of error, including those from sample-specific effects of interfering substances. An advantage of this approach is that the difference in bias between an RM and the average bias of CSs at the concentration (i.e., amount of substance present or quantity value) of the RM is determined and its uncertainty estimated. An RM is considered fit for purpose for those MPs for which commutability is demonstrated.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Sesgo , Técnicas de Laboratorio Clínico/estadística & datos numéricos , Interpretación Estadística de Datos , Humanos , Estándares de Referencia , Manejo de Especímenes/normas , Incertidumbre
16.
Hepatology ; 65(4): 1132-1144, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27981615

RESUMEN

The cut-off point of intrahepatic triglyceride (IHTG) content to define nonalcoholic fatty liver disease (NAFLD) by proton magnetic resonance spectroscopy (1 H-MRS) was established based on the 95th percentile in a group of healthy individuals (i.e., ≥5.56%). Whether this threshold correlates with metabolic and histological changes and whether a further accumulation of IHTG is associated with worsening of these parameters has not been properly assessed in a large cohort of patients. In this cross-sectional study, 352 subjects were carefully characterized with the following studies: liver 1 H-MRS; euglycemic insulin clamp with measurement of glucose turnover; oral glucose tolerance test; and a liver biopsy. Hepatic insulin sensitivity (suppression of endogenous glucose production by insulin) was affected early on after IHTG content was ∼1.5% and remained uniformly impaired (∼40%-45%), regardless of further IHTG accumulation. Skeletal muscle insulin sensitivity showed a gradual impairment at low degrees of IHTG accumulation, but remained unchanged after IHTG content reached the ∼6 ± 2% threshold. A similar pattern was observed for metabolic changes typically associated with NAFLD, such as hypertriglyceridemia and low high-density lipoprotein cholesterol (HDL-C). In contrast, adipose tissue insulin sensitivity (suppression of free fatty acids by insulin) showed a continuous worsening across the spectrum of IHTG accumulation in NAFLD (r = -0.38; P < 0.001). Histological severity of liver disease (inflammation, ballooning, and fibrosis) was not associated with the amount of IHTG content. CONCLUSION: IHTG accumulation is strongly associated with adipose tissue insulin resistance (IR), supporting the current theory of lipotoxicity as a driver of IHTG accumulation. Once IHTG accumulation reaches ∼6 ± 2%, skeletal muscle IR, hypertriglyceridemia, and low HDL-C become fully established. Histological activity appears to have an early threshold and is not significantly influenced by increasing amounts of IHTG accumulation. (Hepatology 2017;65:1132-1144).


Asunto(s)
Diabetes Mellitus Tipo 2/sangre , Ácidos Grasos no Esterificados/metabolismo , Hígado/metabolismo , Enfermedad del Hígado Graso no Alcohólico/sangre , Enfermedad del Hígado Graso no Alcohólico/patología , Triglicéridos/metabolismo , Adulto , Anciano , Biomarcadores/metabolismo , Biopsia con Aguja , Estudios Transversales , Diabetes Mellitus Tipo 2/epidemiología , Diabetes Mellitus Tipo 2/patología , Progresión de la Enfermedad , Femenino , Técnica de Clampeo de la Glucosa/métodos , Humanos , Inmunohistoquímica , Insulina/metabolismo , Resistencia a la Insulina/fisiología , Modelos Lineales , Hígado/patología , Pruebas de Función Hepática , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/epidemiología , Valores de Referencia , Medición de Riesgo , Índice de Severidad de la Enfermedad
18.
Scand J Clin Lab Invest ; 76(2): 177-80, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26785381

RESUMEN

OBJECTIVES: The effects of combining multiple calibrations on assay accuracy (bias) and measurement of calibration stability were investigated for total triiodothyronine (TT3), vitamin B12 and luteinizing hormone (LH) using Beckman Coulter's Access 2 analyzer. METHODS: Three calibration procedures (CC1, CC2 and CC3) combined 12, 34 and 56 calibrator measurements over 1, 2, and 3 days. Bias was calculated between target values and average measured value over 3 consecutive days after calibration. Using regression analysis of calibrator measurements versus measurement date, calibration stability was determined as the maximum number of days before a calibrator measurement exceeded 5% tolerance limits. RESULTS: Competitive assays (TT3, vitamin B12) had positive time regression slopes, while sandwich assay (LH) had a negative slope. Bias values for TT3 were -2.49%, 1.49%, and -0.50% using CC1, CC2 and CC3 respectively, with calibrator stability of 32, 20, and 30 days. Bias values for vitamin B12 were 2.44%, 0.91%, and -0.50%, with calibrator stability of 4, 9, and 12 days. Bias values for LH were 2.26%, 1.44% and -0.29% with calibrator stability of >43, 39 and 36 days. Measured stability was more consistent across calibration procedures using percent change rather than difference from target: 26 days for TT3, 12 days for B12 and 31 days for LH. CONCLUSIONS: Averaging over multiple calibrations produced smaller bias, consistent with improved accuracy. Time regression slopes in percent change were unaffected by number of calibration measurements but calibrator stability measured from the target value was highly affected by the calibrator value at time zero.


Asunto(s)
Hormona Luteinizante/análisis , Triyodotironina/análisis , Vitamina B 12/análisis , Calibración , Inmunoensayo/instrumentación , Inmunoensayo/normas , Mejoramiento de la Calidad , Reproducibilidad de los Resultados
19.
Clin Biochem ; 47(16-17): 158-63, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25130957

RESUMEN

OBJECTIVES: We evaluated the analytical performance of 24 immunoassays using the Beckman Coulter DxI 800 immunoassay systems at Mayo Clinic, Rochester, MN for trueness, precision, detection limits, linearity, and consistency (across instruments and reagent lots). METHODS: Clinically oriented performance goals were defined using the following methods: trueness-published desirable accuracy limits, precision-published desirable biologic variation; detection limits - 0.1 percentile of patient test values, linearity - 50% of total error, and consistency-percentage test values crossing key decision points. Local data were collected for precision, linearity, and consistency. Data were provided by Beckman Coulter, Inc. for trueness and detection limits. RESULTS: All evaluated assays except total thyroxine were within the proposed goals for trueness. Most of the assays met the proposed goals for precision (86% of intra-assay results and 75% of inter-assay results). Five assays had more than 15% of the test results below the minimum detection limits. Carcinoembryonic antigen, total thyroxine and free triiodothyronine exceeded the proposed goals of ±6.3%, ±5% and ±5.7% for dilution linearity. All evaluated assays were within the proposed goals for instrument consistency. Lot-to-lot consistency results for cortisol, ferritin and total thyroxine exceeded the proposed goals of 3.3%, 11.4% and 7% at one medical decision level, while vitamin B12 exceeded the proposed goals of 5.2% and 3.8% at two decision levels. CONCLUSIONS: The Beckman Coulter DxI 800 immunoassay system meets most of these proposed goals, even though these clinically focused performance goals represent relatively stringent limits.


Asunto(s)
Inmunoensayo/métodos , Ferritinas/análisis , Reproducibilidad de los Resultados , Tiroxina/análisis , Triyodotironina/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...