Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
MAbs ; 15(1): 2197668, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37057828

RESUMEN

The multi-attribute method (MAM), a liquid chromatography-mass spectrometry (LC-MS)-based peptide mapping method, has gained increased interest and applications in the biopharmaceutical industry. MAM can, in one method, provide targeted quantitation of multiple site-specific product quality attributes, as well as new peak detection. In this review, we focus on the scientific and regulatory considerations of using MAM in product quality attribute monitoring and quality control (QC) of therapeutic proteins. We highlight MAM implementation challenges and solutions with several case studies, and provide our perspective on the opportunities to use MS in QC for applications other than standard peptide mapping-based MAM.


Asunto(s)
Anticuerpos Monoclonales , Productos Biológicos , Anticuerpos Monoclonales/química , Espectrometría de Masas/métodos , Cromatografía Liquida/métodos , Control de Calidad
2.
Anal Chem ; 95(4): 2203-2212, 2023 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-36669833

RESUMEN

Antibody combination therapies have become viable therapeutic treatment options for certain severe diseases such as cancer. The co-formulation production approach is intrinsically associated with more complex drug product variant profiles and creates more challenges for analytical control of drug product quality. In addition to various individual quality attributes, those arising from the interactions between the antibodies also potentially emerge through co-formulation. In this study, we describe the development of a widely applicable multi-dimensional liquid chromatography coupled to tandem mass spectrometry method for antibody homo- versus hetero-aggregate characterization. The co-formulation of trastuzumab and pertuzumab was used, a challenging model system, comprising two monoclonal antibodies with very similar physicochemical properties. The data presented demonstrate the high stability of the co-formulation, where only minor aggregate formation is observed upon product storage and accelerated temperature or light-stress conditions. The results also show that the homo- and hetero-aggregates, formed in low and comparable proportions, are only marginally impacted by the formulation and product storage conditions. No preferential formation of hetero-aggregates, in comparison to the already existing pertuzumab and trastuzumab homo-aggregates, was observed.


Asunto(s)
Anticuerpos Monoclonales , Espectrometría de Masas en Tándem , Cromatografía Liquida , Anticuerpos Monoclonales/química , Trastuzumab/química
3.
J Am Soc Mass Spectrom ; 33(12): 2319-2327, 2022 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-36442848

RESUMEN

Identification and further characterization of antibody charge variants is a crucial step during biopharmaceutical drug development, particularly with regard to the increasing complexity of novel antibody formats. As a standard analytical approach, manual offline fractionation of charge variants by cation-exchange chromatography followed by comprehensive analytical testing is applied. These conventional workflows are time-consuming and labor-intensive and overall reach their limits in terms of chromatographic separation of enhanced structural heterogeneities raised from new antibody formats. For these reasons, we aimed to develop an alternative online characterization strategy for charge variant characterization of a therapeutic bispecific antibody by online mD-LC-MS at middle-up (2D-LC-MS) and bottom-up (4D-LC-MS) level. Using the implemented online mD-LC-MS approach, all medium- and even low-abundant product variants previously identified by offline fraction experiments and liquid chromatography mass spectrometry could be monitored. The herein reported automated online mD-LC-MS methodology therefore represents a complementary and in part alternative approach for analytical method validation including multiattribute monitoring (MAM) strategies by mass spectrometry, offering various benefits including increased throughput and reduced sample handling and combined protein information at intact protein and peptide level.


Asunto(s)
Proyectos de Investigación , Cromatografía Liquida , Espectrometría de Masas
4.
ACS Omega ; 7(4): 3671-3679, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35128275

RESUMEN

In recent years, a variety of new antibody formats have been developed. One of these formats allows the binding of one type of antibody to two different epitopes. This can for example be achieved by introduction of the "knob-into-hole" format and a combined CrossMab approach. Due to their complexity, these bispecific antibodies are expected to result in an enhanced variety of different degradation products. Reports on the stability of these molecules are still largely lacking. To address this, a panel of stress conditions, including elevated temperature, pH, oxidizing agents, and forced glycation via glucose incubation, to identify and functionally evaluate critical quality attributes in the complementary-determining and conserved regions of a bispecific antibody was applied in this study. The exertion of various stress conditions combined with an assessment by size exclusion chromatography, ion exchange chromatography, LC-MS/MS peptide mapping, and functional evaluation by cell-based assays was adequate to identify chemical modification sites and assess the stability and integrity, as well as the functionality of a bispecific antibody. Stress conditions induced size variants and post-translational modifications, such as isomerization, deamidation, and oxidation, albeit to a modest extent. Of note, all the observed stress conditions largely maintained functionality. In summary, this study revealed the pronounced stability of IgG1 "knob-into-hole" bispecific CrossMab antibodies compared to already marketed antibody products.

5.
Artículo en Inglés | MEDLINE | ID: mdl-35026663

RESUMEN

Methionine is a common excipient used in therapeutic protein liquid formulations as stabilizer and antioxidant. The oxidation of methionine to methionine sulfoxide can be regarded as a sensitive marker of oxidative stress for drug product storage conditions. In this study, a sensitive HPLC method for the quantification of methionine sulfoxide in formulated protein product was developed and qualified according to regulatory requirements using a SIELC® Primesep 100 column with UV detection. The separation involves a mixed-mode mechanism including reversed phase and cationic exchange modalities. The operating range of the method was established between 1 µM and 35 µM of methionine sulfoxide. In this testing range, the method was shown to be linear (R2 > 0.99), accurate (Recovery 92.9 - 103.6%, average recovery = 99.8 ± 1.4%) and precise (intermediate precision at LoQ, CV = 2.9%). The developed test system was successfully applied to study the effects of temperature and storage conditions on methionine sulfoxide formation in complex therapeutic antibody formulations.


Asunto(s)
Excipientes/química , Metionina/análogos & derivados , Biomarcadores/análisis , Cromatografía Líquida de Alta Presión/métodos , Límite de Detección , Modelos Lineales , Metionina/análisis , Metionina/química , Oxidación-Reducción , Reproducibilidad de los Resultados
6.
Talanta ; 234: 122628, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34364437

RESUMEN

An international study was conducted to evaluate the performance and reliability of an online multi-dimensional (mD)-LC-MS/MS approach for the characterization of antibody charge variants. The characterization of antibody charge variants is traditionally performed by time-consuming, offline isolation of charge variant fractions by ion exchange chromatography (IEC) that are subsequently subjected individually to LC-MS/MS peptide mapping. This newly developed mD-LC-MS/MS approach enables automated and rapid characterization of charge variants using much lower sample requirements. This online workflow includes sample reduction, digestion, peptide mapping, and subsequent mass spectrometric analysis within a single, fully-automated procedure. The benefits of using online mD-LC-MS/MS for variant characterization include fewer handling steps, a more than 10-fold reduction in required sample amount, reduced sample hold time as well as a shortening of the overall turnaround time from weeks to few days compared to standard offline procedures. In this site-to-site comparison study, we evaluated the online peptide mapping data collected from charge variants of trastuzumab (Herceptin®) across three international laboratories. The purpose of this study was to compare the overall performance of the online mD-LC-MS/MS approach for antibody charge variant characterization, with all participating sites employing different mD-LC-MS/MS setups (e.g., instrument vendors, modules, columns, CDS software). The high sequence coverage (95%-97%) obtained in each laboratory, enabled a reproducible generation of tryptic peptides and the comparison of values of the charge variants. Results obtained at all three participating sites were in good agreement, highlighting the reliability and performance of this approach, and correspond with data gained by the standard offline procedure. Overall, our results underscore of the benefit mD-LC-MS/MS technology for therapeutic antibody characterization, confirming its potential to become an important tool in the toolbox of protein characterization scientists.


Asunto(s)
Laboratorios , Espectrometría de Masas en Tándem , Anticuerpos Monoclonales , Cromatografía Liquida , Humanos , Reproducibilidad de los Resultados
7.
J Am Soc Mass Spectrom ; 32(8): 2062-2071, 2021 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-33687195

RESUMEN

The aim of this study was to characterize the product variants of a therapeutic T-cell bispecific humanized monoclonal antibody (TCB Mab, ∼200 kDa, asymmetric) and to develop an online cation-exchange chromatography native electrospray mass spectrometry method (CEC-UV-MS) for direct TCB Mab charge variant monitoring during bioprocess and formulation development. For the identification and functional evaluation of the diverse and complex TCB Mab charge variants, offline fractionation combined with comprehensive analytical testing was applied. The offline fractionation of abundant product variant peaks enabled identification of coeluting acid charge variants such as asparagine deamidation, primary and secondary Fab glycosylation (with and without sialic acid), and the presence of O-glycosylation in the G4S-linker region. Consequently, a new nonconsensus N-glycosylation motif (N-338-FG) in the heavy chain CDR region was discovered. Functional evaluation by cell-based potency testing demonstrated a clear and negative impact of both asparagine deamidations, whereas the O-glycosylation did not affect the TCB Mab biological activity. We established an online native CEC-UV-MS method, with an ammonium acetate buffer and pH gradient, to directly monitor the TCB Mab charge variants. All abundant chemical degradations and post-translational amino acid modifications already identified by offline fraction experiments and liquid chromatography mass spectrometry peptide mapping could also be monitored by the online CEC-UV-MS method. The herein reported online native CEC-UV-MS methodology represents a complementary or even alternative approach for multiattribute monitoring of biologics, offering multiple benefits, including increased throughput and reduced sample handling and intact protein information in the near-native state.


Asunto(s)
Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/química , Cromatografía por Intercambio Iónico/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Anticuerpos Monoclonales/metabolismo , Cationes , Regiones Determinantes de Complementariedad , Glicosilación , Fragmentos Fab de Inmunoglobulinas/análisis , Fragmentos Fab de Inmunoglobulinas/química , Fragmentos Fab de Inmunoglobulinas/metabolismo , Mapeo Peptídico/métodos , Rayos Ultravioleta
8.
Anal Chem ; 92(11): 7574-7580, 2020 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-32426963

RESUMEN

Recombinant human erythropoetin (EPO) is an important biopharmaceutical mainly used for the treatment of anemia. It is highly heterogeneous because of common amino acid chemical degradations known to occur in protein therapeutics (e.g., oxidation and deamidation) and its complex glycosylation profile. Recently, multi-attribute monitoring (MAM), i.e., the quantification of multiple post-translational and chemical modifications in a single peptide mapping liquid chromatography-mass spectrometry (LC-MS)-based method, has received increased attention for the analysis of antibody-like biotherapeutic proteins. In this study, an MAM method for examination of residue-specific glycan profiles of EPO was established. The MAM method, by virtue of the increased sensitivity and selectivity provided with LC-MS, yielded additional site-specific information not afforded by the conventional quality control (QC) methods. Low abundant glycans as well as additional post-translational and chemical modifications could also be simultaneously detected by the MAM method. Our results demonstrate that desialylated N-oligosaccharides (DeNO) and N-acetylneuraminic acids (Neu5Ac) could be monitored by the developed MAM approach with data readout highly comparable to QC methods, while differences were observed for charge isoform distribution. In summary, the comparative data obtained demonstrate that MAM by LC-MS peptide mapping can, in principle, adequately replace selected QC methods and would add value to the in-process control and release testing strategy of EPO.


Asunto(s)
Eritropoyetina/análisis , Mapeo Peptídico , Serina Endopeptidasas/metabolismo , Cromatografía Liquida , Eritropoyetina/metabolismo , Glicosilación , Humanos , Espectrometría de Masas , Proteínas Recombinantes/análisis , Proteínas Recombinantes/metabolismo
9.
J Pharm Biomed Anal ; 186: 113251, 2020 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-32251978

RESUMEN

Alongside the success of protein-based bio-therapeutics over the last decades and facilitated by advances both in protein engineering and manufacturing, new product formats progressively enter into the biopharmaceutical industry's pipelines with major implications on the analytical methods used for their characterization. While conventional approaches have proved sufficient for standard (IgG-like) molecules, the increased complexity of novel formats requires proper adjustments of the employed methodologies, in particular with regard to separation-based techniques coupled to UV/FLD detection. After introducing the status quo for the characterization of biopharmaceuticals in quality control settings, this review provides a comprehensive portrayal of emerging LC-MS based technologies, which have already demonstrated their potential to complement the existing analytical toolbox. In this context, the benefits of native LC-MS and two-/multidimensional LC-MS applications to assess product attributes while preserving the higher-order structure are discussed based on challenges arising from the analysis of complex product formats.


Asunto(s)
Terapia Biológica , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Líquida de Alta Presión/tendencias , Espectrometría de Masas/métodos , Espectrometría de Masas/tendencias , Productos Biológicos/química , Humanos , Control de Calidad
10.
Antibodies (Basel) ; 8(4)2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31581521

RESUMEN

The usefulness of higher-order structural information provided by hydrogen/deuterium exchange-mass spectrometry (H/DX-MS) for the structural impact analyses of chemical and post-translational antibody modifications has been demonstrated in various studies. However, the structure-function assessment for protein drugs in biopharmaceutical research and development is often impeded by the relatively low-abundance (below 5%) of critical quality attributes or by overlapping effects of modifications, such as glycosylation, with chemical amino acid modifications; e.g., oxidation or deamidation. We present results demonstrating the applicability of the H/DX-MS technique to monitor conformational changes of specific Fc glycosylation variants produced by in vitro glyco-engineering technology. A trend towards less H/DX in Fc Cγ2 domain segments correlating with larger glycan structures could be confirmed. Furthermore, significant deuterium uptake differences and corresponding binding properties to Fc receptors (as monitored by SPR) between α-2,3- and α-2,6-sialylated Fc glycosylation variants were verified at sensitive levels.

11.
Bioanalysis ; 11(15): 1437-1449, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31490109

RESUMEN

Aim: Fragment crystallizable (Fc) glycosylation of immunoglobulin G-type monoclonal antibodies applied to therapeutic applications is regarded a critical quality attribute and can influence bioactivity, pharmacokinetics and/or immunogenicity/safety. Investigating the impact of certain Fc N-glycans is therefore of importance to assess its criticality for a therapeutic product. This has been done for N-glycan types like fucosylation, galactosylation or sialylation. There were contradictory results reported for functionality especially with regard to sialylation. Material & methods: We elucidated the effect of terminal sialic acid residues on Fcγ receptor binding and antibody dependent cytotoxicity activity of two immunoglobulin G1 antibodies with different levels of fucosylation/bi-secting. Conclusion: We found the impact to be specific to the sialylation linkage type, in other words, α2,3- versus α2,6-linked sialic acid attached to the terminal galactose residues.


Asunto(s)
Citotoxicidad Celular Dependiente de Anticuerpos , Fucosa/metabolismo , Inmunoglobulina G/metabolismo , Ácido N-Acetilneuramínico/metabolismo , Receptores de IgG/metabolismo , Glicosilación , Humanos , Ácidos Neuramínicos/química , Ácidos Neuramínicos/metabolismo , Unión Proteica
12.
MAbs ; 11(7): 1219-1232, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31339437

RESUMEN

Biotherapeutics may contain a multitude of different post-translational modifications (PTMs) that need to be assessed and possibly monitored and controlled to ensure reproducible product quality. During early development of biotherapeutics, unexpected PTMs might be prevented by in silico identification and characterization together with further molecular engineering. Mass determinations of a human IgG1 (mAb1) and a bispecific IgG-ligand fusion protein (BsAbA) demonstrated the presence of unusual PTMs resulting in major +80 Da, and +16/+32 Da chain variants, respectively. For mAb1, analytical cation exchange chromatography demonstrated the presence of an acidic peak accounting for 20%. A + 79.957 Da modification was localized within the light chain complementarity-determining region-2 and identified as a sulfation based on accurate mass, isotopic distribution, and a complete neutral loss reaction upon collision-induced dissociation. Top-down ultrahigh resolution MALDI-ISD FT-ICR MS of modified and unmodified Fabs allowed the allocation of the sulfation to a specific Tyr residue. An aspartate in amino-terminal position-3 relative to the affected Tyr was found to play a key role in determining the sulfation. For BsAbA, a + 15.995 Da modification was observed and localized to three specific Pro residues explaining the +16 Da chain A, and +16 Da and +32 Da chain B variants. The BsAbA modifications were verified as 4-hydroxyproline and not 3-hydroxyproline in a tryptic peptide map via co-chromatography with synthetic peptides containing the two isomeric forms. Finally, our approach for an alert system based on in-house in silico predictors is presented. This system is designed to prevent these PTMs by molecular design and engineering during early biotherapeutic development.


Asunto(s)
Productos Biológicos/química , Terapia Biológica/métodos , Hidroxiprolina/química , Inmunoglobulina G/química , Proteínas Recombinantes de Fusión/química , Tirosina/análogos & derivados , Animales , Células CHO , Cricetulus , Desarrollo de Medicamentos , Humanos , Inmunoglobulina G/genética , Modelos Químicos , Procesamiento Proteico-Postraduccional , Proteínas Recombinantes de Fusión/genética , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Tirosina/química
13.
Commun Biol ; 1: 28, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30271914

RESUMEN

The quality control testing of chemical degradations in the bio-pharmaceutical industry is currently under controversial debate. Here we have systematically applied in vitro and in vivo stress conditions to investigate the influence of protein degradation on structure-function. Extensive purification and characterization enabled identification and functional assessment of the physiological degradation of chemical modification sites in the variable complementarity-determining regions (CDRs) and conserved region of trastuzumab. We demonstrate that the degradation of the solvent-accessible residues located in the CDR and the conserved fragment crystallizable region (Fc) occurs faster in vivo (within days) compared to the levels observed for bio-process and real-time storage conditions. These results hence question the rationality of extreme monitoring of low level alterations in such chemical modifications as critical patient safety parameters in product quality control testing, given that these modifications merely mirror the natural/physiological aging process of endogenous antibodies.

14.
Sci Rep ; 7(1): 5324, 2017 07 13.
Artículo en Inglés | MEDLINE | ID: mdl-28706253

RESUMEN

Erythropoietin (EPO) is a heavily glycosylated hormone whose recombinant forms are used for treatment of anaemia. EPO glycosylation is important for its pharmacological properties. An analytical workflow, which can determine EPO glycosylation in an accurate and high-throughput fashion from cell culture supernatant (CCS) in approximately 24 h, offers the possibility to follow changes during production. To address this challenge, we present a complete workflow consisting of protein purification, glycan release, sialic acid derivatization, solid phase extraction, matrix-assisted laser desorption/ionization - mass spectrometry (MALDI-MS) analysis and MassyTools data processing. EPO purification from CCS by anti-EPO antibody coupled Sepharose beads yielded excellent purity with acceptable recovery and was free of glycoform bias. Glycosylation profiles obtained by MALDI-MS were highly comparable to those obtained with an established capillary gel electrophoresis-laser induced fluorescence method. Our method delivers accurate results for the analysis of changes of important glycosylation parameters, such as sialylation and number of N-acetyllactosamine units, for the time course of a fermentation. We could resolve differences in glycosylation between several CCS samples.


Asunto(s)
Cromatografía de Afinidad/métodos , Medio de Cultivo Libre de Suero/química , Eritropoyetina/aislamiento & purificación , Eritropoyetina/metabolismo , Glicosilación , Animales , Células CHO , Cricetulus , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
15.
Anal Chem ; 89(16): 8233-8237, 2017 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-28700824

RESUMEN

The usefulness of the higher-order structure information provided by hydrogen/deuterium exchange mass spectrometry (HDX-MS) in the protein therapeutic field is undisputed; however, its applicability as a method for critical quality and comparability assessment has until now not been demonstrated. Here we present results demonstrating for the first time the applicability of the HDX-MS technique to monitor structural changes due to methionine oxidation at sensitivity levels realistic to the requirements of biopharmaceutical research and development. For the analyzed heavy chain marker peptides deuterium uptake differences due to oxidation at the conserved methionine in position 254 were significantly verifiable at the lowest increase (1%) through spiked oxidized IgG1.

16.
Anal Chem ; 89(10): 5404-5412, 2017 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-28398745

RESUMEN

We report on the online coupling of FcRn affinity liquid chromatography (LC) with electrospray ionization mass spectrometry (ESI-MS) in native conditions to study the influence of modifications on the interaction of recombinant mAbs with the immobilized FcRn receptor domain. The analysis conditions were designed to fit the requirements of both affinity LC and ESI-MS. The mobile phase composition was optimized to maintain the proteins studied in native conditions and enable sharp pH changes in order to mimic properly IgGs Fc domain/FcRn receptor interaction. Mobile phase components needed to be sufficiently volatile to achieve native MS analysis. MS data demonstrated the conservation of the pseudonative form of IgGs and allowed identification of the separated variants. Native FcRn affinity LC-ESI-MS was performed on a therapeutic mAb undergoing various oxidation stress. Native MS detection was used to determine the sample oxidation level. Lower retention was observed for mAbs oxidized variants compared to their intact counterparts indicating decreased affinities for the receptor. This methodology proved to be suitable to identify and quantify post-translational modifications at native protein level in order to correlate their influence on the binding to the FcRn receptor. Native FcRn affinity LC-ESI-MS can tremendously reduce the time required to assess the biological relevance of the IgG microheterogeneities thus providing valuable information for biopharmaceutical research and development.


Asunto(s)
Anticuerpos Monoclonales/metabolismo , Péptidos/análisis , Receptores Fc/metabolismo , Espectrometría de Masa por Ionización de Electrospray , Animales , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/genética , Cromatografía de Afinidad , Cromatografía Líquida de Alta Presión , Glicosilación , Concentración de Iones de Hidrógeno , Fragmentos Fc de Inmunoglobulinas/química , Fragmentos Fc de Inmunoglobulinas/metabolismo , Ratones , Mapeo Peptídico , Péptidos/aislamiento & purificación , Unión Proteica , Receptores Fc/química , Proteínas Recombinantes/biosíntesis , Proteínas Recombinantes/química , Proteínas Recombinantes/aislamiento & purificación
17.
Mol Pharm ; 14(4): 1292-1299, 2017 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-28206769

RESUMEN

A current concern with the use of therapeutic proteins is the likely presence of aggregates and submicrometer, subvisible, and visible particles. It has been proposed that aggregates and particles may lead to unwanted increases in the immune response with a possible impact on safety or efficacy. The aim of this study was thus to evaluate the ability of subvisible particles of a therapeutic antibody to break immune tolerance in an IgG1 transgenic mouse model and to understand the particle attributes that might play a role in this process. We investigated the immunogenic properties of subvisible particles (unfractionated, mixed populations, and well-defined particle size fractions) using a transgenic mouse model expressing a mini-repertoire of human IgG1 (hIgG1 tg). Immunization with proteinaceous subvisible particles generated by artificial stress conditions demonstrated that only subvisible particles bearing very extensive chemical modifications within the primary amino acid structure could break immune tolerance in the hIgG1 transgenic mouse model. Protein particles exhibiting low levels of chemical modification were not immunogenic in this model.


Asunto(s)
Tolerancia Inmunológica/inmunología , Inmunoglobulina G/química , Secuencia de Aminoácidos , Animales , Anticuerpos Monoclonales/química , Formación de Anticuerpos/inmunología , Humanos , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Tamaño de la Partícula
18.
MAbs ; 9(1): 94-103, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27661266

RESUMEN

Molecular mass determination by electrospray ionization mass spectrometry of a recombinant IgG-based fusion protein (mAb1-F) produced in human embryonic kidney (HEK) cells demonstrated the presence of a dominant +79 Da product variant. Using LC-MS tryptic peptide mapping analysis and collision-induced dissociation (CID) and electron-transfer/higher-energy collision dissociation fragmentations, the modification was localized to the C-terminal serine residue of a glycine-serine linker [(G4S)2] of a fused heavy chain containing in total 2 (G4S)2-linkers. The modification was identified as a phosphorylation (+79.97 Da) by the presence of a 98 Da neutral loss reaction with CID, by spiking a synthetic phosphoserine peptide, and by dephosphorylation with alkaline phosphatase. A thermolysin digest combined with higher-energy collision dissociation (HCD) positioned the phosphoserine to one specific glycine-serine linker of the fused heavy chain, and the relative level of phosphorylated linker was determined to be 11.3% and 0.4% by LC-MS when the fusion protein was transiently expressed in HEK or in stably transformed Chinese hamster ovary cells, respectively. This observation demonstrates that fusions with glycine-serine linker sequences should be carefully evaluated during drug development to prevent the introduction of a phosphorylation site in therapeutic fusion proteins.


Asunto(s)
Anticuerpos Biespecíficos/química , Glicina/química , Inmunoglobulina G/química , Proteínas Recombinantes de Fusión/química , Serina/química , Animales , Anticuerpos Biespecíficos/biosíntesis , Células CHO , Línea Celular , Cricetinae , Cricetulus , Humanos , Inmunoglobulina G/biosíntesis , Fosforilación , Ingeniería de Proteínas , Procesamiento Proteico-Postraduccional
19.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1033-1034: 342-352, 2016 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-27614258

RESUMEN

High-performance anion-exchange chromatography (HPAEC) coupled to pulsed amperometric detection (PAD) is a highly sensitive method for the analysis of oligosaccharides without the need for prior derivatization. However, the method suffers from the lack of chemical information with peak assignments based on the retention times of authentic standards or known peaks of reference materials. Here we applied HPAEC coupled on-line with electrospray ion trap mass spectrometry (HPAEC-MS) using a prototype mini-bore (1mm I.D.) CarboPac PA200 column and challenged the analytical separation based method for the structural assignment of heterogeneous mixtures of N-glycans derived from immunoglobulin G from human plasma, glyco-engineered CHO cells, and Sp2/0 mouse myeloma cells. Compared to an analytical scale 3mm I.D. column, the mini-bore column demonstrated a superior performance with up to 8-fold improved limit of detection for specific N-glycans determined by PAD. Quantitative evaluation by extracted ion current chromatograms revealed detection limits in the 50-100 femtomole range using ion trap MS operated in positive ionization mode. In our hands HPAEC-MS/MS allowed the detection and quantification of even low abundant glycan species including biantennary complex-type, high mannose, hybrid and hybrid bisected structures. In comparison to the detection of N-glycans as lithiated or sodiated adducts, we obtained a 65-fold improved signal-to-noise ratio with protonated ions only. Relative quantitative evaluation by single ion current chromatograms was successfully applied and demonstrated an excellent performance with respect to selectivity in the relative quantification of heterogeneous samples of N-glycans compared to HPAEC-PAD and HILIC-UPLC of 2-AB labelled N-glycans.


Asunto(s)
Cromatografía por Intercambio Iónico/métodos , Inmunoglobulina G/análisis , Polisacáridos/análisis , Espectrometría de Masas en Tándem/métodos , Animales , Aniones , Células CHO , Calibración , Cromatografía Líquida de Alta Presión , Cricetinae , Cricetulus , Interacciones Hidrofóbicas e Hidrofílicas , Límite de Detección , Ratones , Ácido N-Acetilneuramínico/metabolismo , Soluciones
20.
MAbs ; 8(2): 331-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26655595

RESUMEN

High-molecular weight aggregates such as antibody dimers and other side products derived from incorrect light or heavy chain association typically represent critical product-related impurities for bispecific antibody formats. In this study, an approach employing ultra-pressure liquid chromatography size-exclusion separation combined with native electrospray ionization mass spectrometry for the simultaneous formation, identification and quantification of size variants in recombinant antibodies was developed. Samples exposed to storage and elevated temperature(s) enabled the identification of various bispecific antibody size variants. This test system hence allowed us to study the variants formed during formulation and bio-process development, and can thus be transferred to quality control units for routine in-process control and release analytics. In addition, native SEC-UV/MS not only facilitates the detailed analysis of low-abundant and non-covalent size variants during process characterization/validation studies, but is also essential for the SEC-UV method validation prior to admission to the market.


Asunto(s)
Anticuerpos Biespecíficos/química , Cromatografía en Gel , Agregado de Proteínas , Anticuerpos Biespecíficos/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...