Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Arthroplasty ; 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-39002768

RESUMEN

INTRODUCTION: In the past, the utilization of lateral unicompartmental knee arthroplasty (UKA) has been limited at national levels, despite the fact that an estimated 10% of patients who have an indication for arthroplasty, present with isolated lateral compartment osteoarthritis (OA). Units dedicated to UKA have reported good outcomes. Identifying patients for the procedure has been less clear, and the procedure has been perceived to be technically more demanding than medial UKA. This may result in a reluctance to start a lateral UKA practice and challenge the early phase. Therefore, this paper aimed to present the outcomes and learning curve when starting up a lateral UKA practice, as this theme remains unelucidated. METHODS: There were 85 primary fixed-bearing lateral UKAs, with a minimum of 1-year follow-up, performed between 2016 and 2022 by two arthroplasty surgeons with existing UKA practices. The indications were primary (n = 79) or post-traumatic (n = 6) osteoarthritis. Patient-reported outcome measures (PROMs) were assessed at 3, 12, and 24 months. A cumulative sum (CUSUM) analysis was used to evaluate surgical duration and the 12-month Oxford Knee Score (OKS). RESULTS: Median (Interquartile range (IQR)) 12-month OKS, Activity and Participation Questionnaire (APQ), and Forgotten Joint Score (FJS) were 43 (37.5 to 46), 78 (42.5 to 98.5), and 72 (55 to 90), respectively. The OKS outcomes did not reveal adverse effects from the learning curve. A performance shift in surgical duration was observed around case 33. Kaplan-Meier implant survival reached 95.4% at 7 years for the endpoint "implant revision," and 93.5% for "implant revision/implant addition." CONCLUSION: Starting up a lateral UKA practice is safe and efficient for surgeons who have prior medial UKA experience, provided strict adherence to indications. While surgical duration indicated a learning curve over approximately 33 cases, PROMs remained stable, suggesting proficient outcomes irrespective of the learning curve.

2.
Bone Joint J ; 106-B(3 Supple A): 31-37, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38423094

RESUMEN

Aims: In metal-on-polyethylene (MoP) total hip arthroplasty (THA), large metal femoral heads have been used to increase stability and reduce the risk of dislocation. The increased size of the femoral head can, however, lead to increased taper corrosion, with the release of metal ions and adverse reactions. The aim of this study was to investigate the relationship between the size of the femoral head and the levels of metal ions in the blood in these patients. Methods: A total of 96 patients were enrolled at two centres and randomized to undergo MoP THA using either a 32 mm metal head or a femoral head of between 36 mm and 44 mm in size, being the largest possible to fit the thinnest available polyethylene insert. The levels of metal ions and patient-reported outcome measures (Oxford Hip Score, University of California, Los Angeles Activity Scale) were recorded at two and five years postoperatively. Results: At five years, the median levels of chromium, cobalt, and titanium were 0.5 µg/l (interquartile range (IQR) 0.50 to 0.62), 0.24 µg/l (IQR 0.18 to 0.30), and 1.16 µg/l (IQR 1.0 to 1.68) for the 32 mm group, and 0.5 µg/l (IQR 0.5 to 0.54), 0.23 µg/l (IQR 0.17 to 0.39), and 1.30 µg/l (IQR 1 to 2.05) for the 36 mm to 44 mm group, with no significant difference between the groups (p = 0.825, p = 1.000, p = 0.558). There were increased levels of metal ions at two years postoperatively in seven patients in the 32 mm group, compared with four in the 36 mm to 44 mm group, and at five years postoperatively in six patients in the 32 mm group, compared with seven in the 36 mm to 44 mm group. There was no significant difference in either the OHS (p = 0.665) or UCLA (p = 0.831) scores between patients with or without an increased level of metal ions. Conclusion: In patients who underwent MoP THA, we found no differences in the levels of metal ions five years postoperatively between those with a femoral head of 32 mm and those with a femoral head of between 36 mm and 44 mm, and no corrosion-related revisions. As taper corrosion can start after five years, there remains a need for longer-term studies investigating the relationship between the size of the femoral head size and corrosion in patients undergoing MoP THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Cabeza Femoral/cirugía , Prótesis de Cadera/efectos adversos , Iones , Metales , Polietileno
3.
Acta Orthop ; 94: 316-320, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-37378682

RESUMEN

BACKGROUND AND PURPOSE: In existing studies on fasttrack unicompartmental knee arthroplasty (UKA), the majority of surgeries are medial. There are substantial differences between lateral and medial UKA, which is why outcomes cannot automatically be compared. To gain information on the feasibility and safety of fast-track protocols in lateral UKAs, we investigated length of stay (LOS) and early complications after lateral UKA, performed using a fast-track protocol in well-established fast-track centers. PATIENTS AND METHODS: We retrospectively evaluated prospectively collected data on patients undergoing lateral UKA in a fast-track setup from 2010 to 2018 at 7 Danish fast-track centers. Data on patient characteristics, LOS, complications, reoperations, and revisions was analyzed using descriptive statistics. Safety and feasibility were defined as complication and reoperation rates within 90 days comparable to non-fast track lateral UKA or fast-track medial UKA. RESULTS: We included 170 of patients with a mean age of 66 (SD 12) years. Median LOS was 1 day (interquartile range 1-1), which was unchanged from 2012-2018. 18% were discharged on the day of surgery. Within 90 days, 7 patients experienced medical complications and 5 patients experienced surgical complications. 3 patients underwent reoperation, 2 were soft tissue revisions and the third was removal of an exostosis due to catching of the patella. 1 patient was revised due to a bearing dislocation. CONCLUSION: Our findings suggest that lateral UKA in a fast-track setting is feasible and safe.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Estudios Prospectivos , Reoperación , Segunda Cirugía , Osteoartritis de la Rodilla/cirugía , Resultado del Tratamiento
4.
Hip Int ; 33(2): 184-192, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34102902

RESUMEN

AIM: To investigate the effect of femoral head size on blood metal-ion levels caused by taper corrosion in metal-on-polyethylene total hip arthroplasty, comparing 36- to 44-mm heads with 32-mm heads. METHODS: In a randomised, controlled, single-blinded trial, 96 patients were allocated to receive either a 32-mm metal head or the largest possible metal head (36-44 mm) that could be accommodated in the thinnest available vitamin E, cross-linked polyethylene insert. Blood metal ion levels were collected at 1- and 2-year follow-ups. RESULTS: At 1-year, metal-ion levels did not differ between the groups. The median (interquartile range) blood-ion levels for the 32-mm versus the 36- to 44-mm group were 0.11 µg/L (0.08-0.15) versus 0.12 µg/L (0.08-0.22), p = 0.546, for cobalt, 0.50 µg/L (0.50-0.59) versus 0.50 µg/L (0.50-1.20), p = 0.059, for chromium and 1.58 µg/L (1.38-2.05) versus 1.48 µg/L (1.14-1.87), p = 0.385, for titanium. At 2 years, there was no difference either and the corresponding values were 0.15 µg/L (0.12-0.24) versus 0.18 µg/L (0.12-0.28), p = 0.682 for cobalt, 0.50 µg/L (0.50-0.50) versus 0.50 µg/L (0.50-0.57), p = 0.554, for chromium and 1.54 µg/L (1.16-1.87) versus 1.42 µg/L (1.01-1.72), p = 0.207 for titanium. CONCLUSIONS: The use of the largest possible metal head (36-44 mm) compared to a 32-mm head in metal-on-polyethylene bearings does not appear to elevate blood metal-ion levels up to 2 years postoperatively. As taper corrosion is probably time-dependent, longer-term reports are needed to evaluate the association between large metal heads and blood metal ion levels.Trial registration: ClinicalTrials.gov (reg. ID NCT0231 6704).


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Cabeza Femoral/cirugía , Titanio , Polietileno , Metales , Cromo , Cobalto , Iones , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA