Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Cardiovasc Magn Reson ; 26(1): 100992, 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38211655

RESUMEN

BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.

3.
Eur Heart J Cardiovasc Imaging ; 23(9): 1260-1271, 2022 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-34999818

RESUMEN

AIMS: Diagnosis of prosthetic valve endocarditis (PVE) by positron emission computed tomography angiography (PET/CTA) is based on visual and quantitative morpho-metabolic features. However, the fluorodeoxyglucose (FDG) uptake pattern can be sometimes visually unclear and susceptible to subjectivity. This study aimed to validate a new parameter, the valve uptake index [VUI, maximum standardized uptake value (SUVmax)-mean standardized uptake value (SUVmean)/SUVmax], designed to provide a more objective indication of the distribution of metabolic activity. Secondly, to re-evaluate the utility of traditionally used PVE imaging criteria and determine the potential value of adding the VUI in the diagnostic algorithm of PVE. METHODS AND RESULTS: Retrospective analysis of 122 patients (135 prosthetic valves) admitted for suspicion of endocarditis, with a conclusive diagnosis of definite (N = 57) or rejected (N = 65) PVE, and who had undergone a cardiac PET/CTA scan as part of the diagnostic evaluation. We measured the VUI and recorded the SUVmax, SUVratio, uptake pattern, and the presence of endocarditis-related anatomic lesions. The VUI, SUVmax, and SUVratio values were 0.54 ± 0.1 vs. 0.36 ± 0.08, 7.68 ± 3.07 vs. 3.72 ± 1.11, and 4.28 ± 1.93 vs. 2.16 ± 0.95 in the 'definite' PVE group vs. the 'rejected' group, respectively (mean ± SD; P < 0.001). A cut-off value of VUI > 0.45 showed a sensitivity, specificity, and diagnostic accuracy for PVE of 85%, 88%, and 86.7% and increased diagnostic ability for confirming endocarditis when combined with the standard diagnostic criteria. CONCLUSIONS: The VUI demonstrated good diagnostic accuracy for PVE, even increasing the diagnostic power of the traditionally used morphometabolic parameters, which also confirmed their own diagnostic performance. More research is needed to assess whether the integration of the VUI into the PVE diagnostic algorithm may clarify doubtful cases and thus improve the diagnostic yield of PET/CTA.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Endocarditis/diagnóstico por imagen , Endocarditis Bacteriana/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Radiofármacos , Estudios Retrospectivos
4.
Radiol Cardiothorac Imaging ; 3(6): e210029, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34934947

RESUMEN

PURPOSE: To identify entry tear variables that are related to adverse clinical events by using CT angiography (CTA) performed during the subacute phase of aortic dissection. MATERIALS AND METHODS: In this prospective study conducted from January 2000 to December 2013, participants with an aortic dissection with a patent false lumen and no comorbidities underwent CTA during the subacute phase. Participants were followed up for a survival analysis to assess the time to an adverse aortic event (AAE). The maximum aortic diameter (MAD), proximal and distal tear areas and difference between these areas, and partial false-lumen thrombosis were assessed by using Cox regression for adverse events. RESULTS: Seventy-two participants (mean age, 55 years ± 12 [standard deviation]; 55 men) were evaluated: 47 were surgically treated (type A aortic dissection) and 25 were medically treated (type B aortic dissection). Twenty-two participants had an AAE manifest during follow-up (9.22 years ± 5.78): There were 18 elective surgeries for aneurysmal degeneration, two emergent surgeries for acute aortic syndrome, and two aortic condition-related deaths. A categorical model composed of genetic aortic disease (GAD) (hazard ratio [HR], 3.4 [95% CI: 1.2, 9.9]; P = .02), MAD greater than 45 mm (HR, 6.1 [95% CI: 2.4, 15.8]; P < .001), and tear dominance (HR, 5.2 [95% CI: 2.1, 13]; P < .001), defined as an absolute tear area difference of greater than 1.2 cm2, was used to stratify participants into three risk groups: low, without any risk factors (57% [41 of 72] and 7% [three of 41] had events); intermediate, with one risk factor (31% [22 of 72] and 50% [11 of 22] had events); and high, with two or more risk factors (13% [nine of 72] and 89% [eight of nine] had events; log rank P < .001). CONCLUSION: Tear dominance demonstrated at CTA performed in the subacute phase of aortic dissection was related to long-term adverse events. Participants without GAD, dominant tears, or MAD greater than 45 mm had conditions that were safely managed with optimal medical treatment and imaging follow-up.Keywords: CT Angiography, Vascular, Aorta, Dissection Supplemental material is available for this article. © RSNA, 2021See also commentary by Fleischmann and Burris in this issue.

6.
JACC Case Rep ; 3(4): 566-572, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33821246

RESUMEN

We present a case of acute myocarditis with left ventricular dysfunction and intracavitary thrombosis in a 55-year-old man with severe acute respiratory syndrome coronavirus 2 infection (coronavirus disease 2019) who was admitted with bilateral atypical pneumonia. The patient was treated with anticoagulation and optimal heart failure therapy and had an improvement of left ventricular function and thrombus resolution. (Level of Difficulty: Intermediate.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...