Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Extra Corpor Technol ; 52(2): 142-145, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32669741

RESUMEN

Bloodless pediatric cardiac surgery requiring the use of cardiopulmonary bypass (CPB) remains a challenge for the entire operating room (OR) team. The amount of circulating blood volume to pump prime volume mismatch of small patients results in hemodilution that frequently results in transfusion of allogeneic blood products. Patients of families of the Jehovah's Witness (JW) faith reject the use of these products because of religious beliefs. Our institution is a referral center for children of JW families because we have developed techniques to minimize blood loss with the hope of performing bloodless pediatric cardiac surgery whenever possible. These techniques include preoperative treatment with erythropoietin, intraoperative acute normovolemic hemodilution, CPB circuit miniaturization, ultrafiltration during and after CPB, limiting blood gas analyses or other unnecessary blood draws, and using hemostatic agents during and after CPB. We present the case of a 4-day-old patient of the JW faith weighing 2.7 kg with transposition of the great arteries and an intact ventricular septum who underwent an arterial switch operation. The patient received no allogeneic blood product administration throughout the entire hospitalization. The patient's first hematocrit in the OR was 43%, lowest hematocrit on bypass was 15%, and first hematocrit in the cardiothoracic intensive care unit post-procedure was 21%. The patient was discharged on post-op day nine with a hematocrit of 36%.


Asunto(s)
Operación de Switch Arterial , Testigos de Jehová , Procedimientos Médicos y Quirúrgicos sin Sangre , Puente Cardiopulmonar , Niño , Humanos , Transposición de los Grandes Vasos
2.
Perfusion ; 33(7): 520-524, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29637840

RESUMEN

The desired use of the HPH Jr. is optimal due to the low priming volume; however, the lower rate of volume removal necessitates utilization of a larger hemofilter. Larger hemofilters carry a higher prime volume, which is impactful in the pediatric setting. Pediatric cardiac surgery patients under 18 kilograms requiring cardiopulmonary bypass were randomly assigned to one of two study groups. Group 1 (coated) contained an HPH Jr. hemofilter that was primed with the addition of 25% albumin and heparin. Group 2 (non-coated) contained an HPH Jr. hemofilter that was primed with only Normosol-R®. After cardioplegia delivery, zero balance ultrafiltration (ZBUF) was initiated and maintained for thirty consecutive minutes. The flow through the hemofilter was standardized at 70 ml/min and the vacuum applied to the effluent line was set at -150 mmHg. Effluent fluid removal was measured at the termination of thirty minutes and compared between the groups. Group comparisons between the coated vs non-coated hemofilter groups were assessed using two-sample t-tests or the Mann-Whitney U test, when appropriate. Forty-two patients were included in the analysis. There were 22 patients who had the non-coated hemofilter and 20 patients with a coated hemofilter. The differences between the two groups are illustrated in Table 1. There was a statistically significant higher ultrafiltration volume with the coated hemofilter group (p=0.008) (Figure 1). These results illustrate the improved efficiency of the HPH Jr. with the addition of 25% albumin and heparin during the priming process.


Asunto(s)
Albúminas/metabolismo , Puente Cardiopulmonar/métodos , Hemofiltración/métodos , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA