Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Anal Chim Acta ; 1221: 340118, 2022 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-35934401

RESUMEN

Considering the complexities and speed of modern food chains, there is an increasing demand for point-of-need detection of food contaminants, particularly highly regulated chemicals and carcinogens such as aflatoxin B1. We report a user-friendly smartphone-based magneto-immunosensor on carbon black modified electrodes for point-of-need detection of aflatoxin B1 in cereals. For buffered analyte solutions and a corn extract sample, the assay demonstrated a low limit of detection of 13 and 24 pg/mL, respectively. The assay was also highly reproducible, exhibiting mean relative standard deviations of 3.7% and 4.0% for the buffered analyte and corn extract samples. The applicability of the assay was validated on the basis of EU guidelines and the detection capability was lower than or equal to 2 µg/kg, which is the EU maximum residue limit for aflatoxin B1 in cereals. False-positive and false-negative rates were less than 5%. Additionally, an open-source android application, AflaESense, was designed to provide a simple interface that displays the result in a traffic-light-type format, thus minimizing user training and time for data analysis. AflaESense was used for smartphone-based screening of spiked corn samples containing aflatoxin B1 (0.1, 2, and 10 ng/mL), and naturally contaminated corn containing 0.15 ng aflatoxin B1/mL. The measured values were in close agreement with spiked concentrations (r2 = 0.99), with recovery values ranging between 80 and 120%. Finally, contaminated samples correctly triggered a red alert while the non-contaminated samples led to the display of a green color of AflaESense. To the best of our knowledge, this is the first smartphone-based electrochemical system effective for screening samples for contamination with aflatoxin B1.


Asunto(s)
Aflatoxina B1 , Técnicas Biosensibles , Aflatoxina B1/análisis , Grano Comestible/química , Electrodos , Contaminación de Alimentos/análisis , Inmunoensayo , Extractos Vegetales/análisis , Teléfono Inteligente , Hollín
3.
Nanoscale ; 14(12): 4690-4704, 2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35262538

RESUMEN

We describe the outcome of a large international interlaboratory study of the measurement of particle number concentration of colloidal nanoparticles, project 10 of the technical working area 34, "Nanoparticle Populations" of the Versailles Project on Advanced Materials and Standards (VAMAS). A total of 50 laboratories delivered results for the number concentration of 30 nm gold colloidal nanoparticles measured using particle tracking analysis (PTA), single particle inductively coupled plasma mass spectrometry (spICP-MS), ultraviolet-visible (UV-Vis) light spectroscopy, centrifugal liquid sedimentation (CLS) and small angle X-ray scattering (SAXS). The study provides quantitative data to evaluate the repeatability of these methods and their reproducibility in the measurement of number concentration of model nanoparticle systems following a common measurement protocol. We find that the population-averaging methods of SAXS, CLS and UV-Vis have high measurement repeatability and reproducibility, with between-labs variability of 2.6%, 11% and 1.4% respectively. However, results may be significantly biased for reasons including inaccurate material properties whose values are used to compute the number concentration. Particle-counting method results are less reproducibile than population-averaging methods, with measured between-labs variability of 68% and 46% for PTA and spICP-MS respectively. This study provides the stakeholder community with important comparative data to underpin measurement reproducibility and method validation for number concentration of nanoparticles.

4.
Molecules ; 27(3)2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35164246

RESUMEN

Whereas the characterization of nanomaterials using different analytical techniques is often highly automated and standardized, the sample preparation that precedes it causes a bottleneck in nanomaterial analysis as it is performed manually. Usually, this pretreatment depends on the skills and experience of the analysts. Furthermore, adequate reporting of the sample preparation is often missing. In this overview, some solutions for techniques widely used in nano-analytics to overcome this problem are discussed. Two examples of sample preparation optimization by automation are presented, which demonstrate that this approach is leading to increased analytical confidence. Our first example is motivated by the need to exclude human bias and focuses on the development of automation in sample introduction. To this end, a robotic system has been developed, which can prepare stable and homogeneous nanomaterial suspensions amenable to a variety of well-established analytical methods, such as dynamic light scattering (DLS), small-angle X-ray scattering (SAXS), field-flow fractionation (FFF) or single-particle inductively coupled mass spectrometry (sp-ICP-MS). Our second example addresses biological samples, such as cells exposed to nanomaterials, which are still challenging for reliable analysis. An air-liquid interface has been developed for the exposure of biological samples to nanomaterial-containing aerosols. The system exposes transmission electron microscopy (TEM) grids under reproducible conditions, whilst also allowing characterization of aerosol composition with mass spectrometry. Such an approach enables correlative measurements combining biological with physicochemical analysis. These case studies demonstrate that standardization and automation of sample preparation setups, combined with appropriate measurement processes and data reduction are crucial steps towards more reliable and reproducible data.

5.
Molecules ; 26(17)2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34500752

RESUMEN

ACEnano is an EU-funded project which aims at developing, optimising and validating methods for the detection and characterisation of nanomaterials (NMs) in increasingly complex matrices to improve confidence in the results and support their use in regulation. Within this project, several interlaboratory comparisons (ILCs) for the determination of particle size and concentration have been organised to benchmark existing analytical methods. In this paper the results of a number of these ILCs for the characterisation of NMs are presented and discussed. The results of the analyses of pristine well-defined particles such as 60 nm Au NMs in a simple aqueous suspension showed that laboratories are well capable of determining the sizes of these particles. The analysis of particles in complex matrices or formulations such as consumer products resulted in larger variations in particle sizes within technologies and clear differences in capability between techniques. Sunscreen lotion sample analysis by laboratories using spICP-MS and TEM/SEM identified and confirmed the TiO2 particles as being nanoscale and compliant with the EU definition of an NM for regulatory purposes. In a toothpaste sample orthogonal results by PTA, spICP-MS and TEM/SEM agreed and stated the TiO2 particles as not fitting the EU definition of an NM. In general, from the results of these ILCs we conclude that laboratories are well capable of determining particle sizes of NM, even in fairly complex formulations.

6.
Nanomaterials (Basel) ; 11(8)2021 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-34443705

RESUMEN

Etched ion-track polycarbonate membranes with conical nanochannels of aspect ratios of ~3000 are coated with Al2O3, TiO2, and SiO2 thin films of thicknesses between 10 and 20 nm by atomic layer deposition (ALD). By combining ion-track technology and ALD, the fabrication of two kinds of functional structures with customized surfaces is presented: (i) arrays of free-standing conical nanotubes with controlled geometry and wall thickness, interesting for, e.g., drug delivery and surface wettability regulation, and (ii) single nanochannel membranes with inorganic surfaces and adjustable isoelectric points for nanofluidic applications.

7.
Foods ; 10(6)2021 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-34204284

RESUMEN

Standard methods for chemical food safety testing in official laboratories rely largely on liquid or gas chromatography coupled with mass spectrometry. Although these methods are considered the gold standard for quantitative confirmatory analysis, they require sampling, transferring the samples to a central laboratory to be tested by highly trained personnel, and the use of expensive equipment. Therefore, there is an increasing demand for portable and handheld devices to provide rapid, efficient, and on-site screening of food contaminants. Recent technological advancements in the field include smartphone-based, microfluidic chip-based, and paper-based devices integrated with electrochemical and optical biosensing platforms. Furthermore, the potential application of portable mass spectrometers in food testing might bring the confirmatory analysis from the laboratory to the field in the future. Although such systems open new promising possibilities for portable food testing, few of these devices are commercially available. To understand why barriers remain, portable food analyzers reported in the literature over the last ten years were reviewed. To this end, the analytical performance of these devices and the extent they match the World Health Organization benchmark for diagnostic tests, i.e., the Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, and Deliverable to end-users (ASSURED) criteria, was evaluated critically. A five-star scoring system was used to assess their potential to be implemented as food safety testing systems. The main findings highlight the need for concentrated efforts towards combining the best features of different technologies, to bridge technological gaps and meet commercialization requirements.

8.
Biosens Bioelectron ; 192: 113491, 2021 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-34271399

RESUMEN

The Lateral Flow Immuno Assay (LFIA) is a well-established technique that provides immediate results without high-cost laboratory equipment and technical skills from the users. However, conventional colorimetric LFIA strips suffer from high limits of detection, mainly due to the analysis of a limited sample volume, short reaction time between the target analyte and the conjugation molecules, and a weak optical signal. Thus, LFIAs are mainly employed as a medical diagnostic tool for qualitative and semi/quantitative detection, respectively. We applied a novel cellulose nanofiber (CNF) aerogel material incorporated into LFIA strips to increase the sample flow time, which in turn extends the binding interactions between the analyte of interest and the detection antibody, thus improving the limit of detection (LOD). Compared to a conventional LFIA strip, the longer sample flow time in the aerogel modified LFIA strips improved the LOD for the detection of mouse IgG in a buffer solution by a 1000-fold. The accomplished LOD (0.01 ng/mL) even outperformed specifications of a commercial ELISA kit by a factor of 10, and the CNF aerogel assisted LFIA was successfully applied to detect IgG in human serum with a LOD of 0.72 ng/mL. Next to the improved LOD, the aerogel assisted LFIA could quantify IgG samples in buffer and human serum in the concentration ranges of 0.17 ng/mL - 100 ng/mL (in buffer) and 4.6 ng/mL - 100 ng/mL (in human serum). The presented solution thus poses a unique potential to transform lateral flow assays into highly sensitive, fully quantitative point-of-care diagnostics.


Asunto(s)
Técnicas Biosensibles , Animales , Colorimetría , Ensayo de Inmunoadsorción Enzimática , Inmunoensayo , Límite de Detección , Ratones
9.
Small ; 14(18): e1703144, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29399954

RESUMEN

During the last decade, nanofluidic devices based on solid-state nanopores and nanochannels have come into scene in materials science and will not leave anytime soon. One of the main reasons for this is the excellent control over ionic transport exerted by such devices that promises further important advances when integrated into more complex molecular devices. As a result, pH, temperature, and voltage-regulated devices have been obtained. However, nowadays, there is still a necessity for molecule-driven nanofluidic devices. Here, a sugar-regulated pH-responsive nanofluidic diode is presented obtained by surface modification of conical polycarbonate nanochannels with electropolymerized 3-aminophenylboronic acid. Control over the ionic transport has been achieved by a successful decoration of asymmetric nanochannels with integrated molecular systems. The as-synthesized boronate-appended zwitterionic polymer exhibits an acid-base equilibrium that depends on the concentration of sugar, which ultimately acts as a chemical effector setting different pH-dependent rectification regimes. As a result, the same nanodevice can perform completely different proton-regulated nanofluidic operations, i.e., anion-driven rectification, cation-driven rectification, and no rectification, by simply varying the concentration of fructose in the electrolyte solution.

10.
Sci Rep ; 7(1): 11366, 2017 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-28900164

RESUMEN

The interaction of micro- and nano-structured target surfaces with high-power laser pulses is being widely investigated for its unprecedented absorption efficiency. We have developed vertically aligned metallic micro-pillar arrays for laser-driven proton acceleration experiments. We demonstrate that such targets help strengthen interaction mechanisms when irradiated with high-energy-class laser pulses of intensities ~1017-18 W/cm2. In comparison with standard planar targets, we witness strongly enhanced hot-electron production and proton acceleration both in terms of maximum energies and particle numbers. Supporting our experimental results, two-dimensional particle-in-cell simulations show an increase in laser energy conversion into hot electrons, leading to stronger acceleration fields. This opens a window of opportunity for further improvements of laser-driven ion acceleration systems.

11.
Nanoscale ; 8(3): 1470-8, 2016 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-26676314

RESUMEN

In recent years there has been increasing interest in the development of new methods for conferring functional features to nanopore-based fluidic devices. In this work, we describe for the first time the noncovalent integration of amphoteric-amphipathic polymers, also known as "amphipols", into single conical nanopores in order to obtain signal-responsive chemical nanodevices. Highly-tapered conical nanopores were fabricated by single-sided chemical etching of polycarbonate foils. After etching, the surface of the conical nanopores was chemically modified, by first metallizing the surface via gold sputtering and then by amphiphilic self-assembly of the amphipol. The net charge of adsorbed amphipols was regulated via pH changes under the environmental conditions. The pH-dependent chemical equilibrium of the weak acidic and basic monomers facilitates the regulation of the ionic transport through the nanopore by adjusting the pH of the electrolyte solution. Our results demonstrate that functional amphipathic polymers are powerful building blocks for the surface modification of nanopores and might ultimately pave the way to a new means of integrating functional and/or responsive units within nanofluidic structures.

12.
Beilstein J Nanotechnol ; 6: 1272-80, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26199830

RESUMEN

BACKGROUND: Multicomponent heterostructure nanowires and nanogaps are of great interest for applications in sensorics. Pulsed electrodeposition in ion-track etched polymer templates is a suitable method to synthesise segmented nanowires with segments consisting of two different types of materials. For a well-controlled synthesis process, detailed analysis of the deposition parameters and the size-distribution of the segmented wires is crucial. RESULTS: The fabrication of electrodeposited AuAg alloy nanowires and segmented Au-rich/Ag-rich/Au-rich nanowires with controlled composition and segment length in ion-track etched polymer templates was developed. Detailed analysis by cyclic voltammetry in ion-track membranes, energy-dispersive X-ray spectroscopy and scanning electron microscopy was performed to determine the dependency between the chosen potential and the segment composition. Additionally, we have dissolved the middle Ag-rich segments in order to create small nanogaps with controlled gap sizes. Annealing of the created structures allows us to influence their morphology. CONCLUSION: AuAg alloy nanowires, segmented wires and nanogaps with controlled composition and size can be synthesised by electrodeposition in membranes, and are ideal model systems for investigation of surface plasmons.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...