Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
JAMA Otolaryngol Head Neck Surg ; 148(7): 646-653, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35679063

RESUMEN

Importance: Postthyroidectomy hemorrhage is a potentially life-threatening complication with no reliable noninvasive method of early detection. Objective: To evaluate the diagnostic accuracy of neck circumference measurement for early detection of postoperative hemorrhage after thyroidectomy. Design, Setting, and Participants: This diagnostic accuracy study at an academic teaching hospital used a prospective cohort of patients undergoing thyroid surgery from November 1, 2015, to January 31, 2018 (group 1), and a retrospective cohort of patients undergoing the same surgery from January 1, 2020, to September 30, 2021 (group 2). We performed repeated perioperative neck circumference measurements to evaluate the association of increased neck circumference with postthyroidectomy hemorrhage among patients at risk for hemorrhage. Main Outcomes and Measures: The primary end point was the diagnostic value of neck circumference measurement for detection of postthyroidectomy hemorrhage. Additionally, data on demographic information and risk factors for postthyroidectomy hemorrhage were examined. Data analyses were performed from November 1, 2021, to January 5, 2022. Results: The prospective cohort (group 1) comprised 60 patients (45 [75%] women) with a mean (SD) age of 52.2 (13.5) years; those who experienced a postthyroidectomy hemorrhage had a mean (SD) age of 57.4 (9.0) years. The retrospective cohort (group 2) comprised 353 patients (258 [73%] women) with a mean (SD) age of 55.3 (14.1) years; patients who experienced a postthyroidectomy hemorrhage had a mean (SD) age of 62.2 (10.0) years. In group 1, postoperative neck circumference increased by a median (range) of 5.0 (4.0 to 7.0) cm in patients with hemorrhage, and only 1.0 (-2.5 to 4.0) cm in patients with no postoperative bleeding (difference in the medians, 4.0 cm [95% CI, 3.0 to 5.5 cm]; effect size, 3.74 [95% CI, 2.6 to 4.9]). Defining a 7% or greater increase in neck circumference as the cutoff value for detecting postthyroidectomy hemorrhage showed a diagnostic sensitivity and specificity of 1.0 (95% CI, 0.48 to 1.0) and 0.86 (95% CI, 0.71 to 0.92), respectively. The retrospective validation also showed a difference in median (range) increase of postoperative neck circumference between patients with hemorrhage and those without-3.0 (0 to 6.0) cm vs 0.0 (-6.0 to 5.0) cm (difference in medians, 3.8 cm [95% CI, 3.0 to 4.9]; effect size, 1.63 [95% CI, 0.96 to 2.3]). Considering 12 false-positive and 332 correct-negative results, the diagnostic tool showed a sensitivity of 0.89 (95% CI, 0.51 to 0.99) and a specificity of 0.97 (95% CI, 0.94 to 0.98). Conclusions and Relevance: The findings of this diagnostic accuracy study suggest that neck circumference measurement is a feasible and easy-to-use diagnostic tool for routine clinical care to detect postthyroidectomy hemorrhage. A 7% or greater increase over the postoperative baseline neck circumference seems to be a reliable threshold for detecting postthyroidectomy hemorrhage. Neck circumference measurement should be used in combination with surveillance of clinical signs and symptoms.


Asunto(s)
Cuello , Tiroidectomía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Hemorragia Posoperatoria/diagnóstico , Hemorragia Posoperatoria/epidemiología , Hemorragia Posoperatoria/etiología , Estudios Prospectivos , Estudios Retrospectivos , Tiroidectomía/efectos adversos
2.
Surg Endosc ; 36(1): 117-125, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-33427912

RESUMEN

BACKGROUND: Due to improvements in endoscopic as well as robotic technology, and a request for better cosmetic results, there was a significant increase in thyroid surgery using these methods during the past decade. METHODS: The aim of our study is to evaluate the perioperative short- and long-term outcome as well as the learning curve of EndoCATS and the Quality of Life (QoL). RESULTS: A total of 150 patients with 152 hemithyroidectomies who underwent endoscopic thyroid surgery by EndoCATS between 2010 and 2016 were enrolled in this study. The mean specimen volume was 15.04 g ± 7.89 g. The mean operation time was 132.79 ± 50.52 min. There is a significant reduction of the operation time after the 53th case. (p < 0.05) There was no acute rebleeding or permanent hypoparathyroidism. Permanent RLN palsy occurred in 3 nerves at risk (NAR) 1.97%. There were no cases of pneumothorax, postoperative infections or skin flap ischemia. 94.11% of the patients describe their state of general health as good as or better than before the surgery. CONCLUSIONS: EndoCATS is a safe and effective, but a demanding single port access procedure; therefore, extensive training is required. An advantage is the near ideal visualization of the RLN and the parathyroid glands as well as the ability to recover even large specimens without difficulties.


Asunto(s)
Calidad de Vida , Neoplasias de la Tiroides , Análisis de Datos , Endoscopía/métodos , Humanos , Glándulas Paratiroides , Estudios Retrospectivos , Neoplasias de la Tiroides/cirugía , Tiroidectomía/métodos
3.
Surg Endosc ; 36(2): 968-979, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33683436

RESUMEN

BACKGROUND: Thyroid surgery is often performed, especially in young female patients. As patient satisfaction become more and more important, different extra-cervical "remote" approaches have evolved to avoid visible scars in the neck for better cosmetic outcome. The most common remote approaches are the transaxillary and retroauricular. Aim of this work is to compare Endoscopic Cephalic Access Thyroid Surgery (EndoCATS) and axillo-bilateral-breast approach (ABBA) to standard open procedures regarding perioperative outcome and in addition to control cohorts regarding quality of life (QoL) and patient satisfaction. METHODS: In a single center, 59 EndoCATS und 52 ABBA procedures were included out of a 2 years period and compared to 225 open procedures using propensity-score matching. For the endoscopic procedures, cosmetic outcome, patient satisfaction and QoL (SF-12 questionnaire) were examined in prospective follow-up. For QoL a German standard cohort and non-surgically patients with thyroid disease were used as controls. RESULT: The overall perioperative outcome was similar for all endoscopic compared to open thyroid surgeries. Surgical time was longer for endoscopic procedures. There were no cases of permanent hypoparathyroidism and no significant differences regarding temporary or permanent recurrent laryngeal nerve (RLN) palsies between open and ABBA or EndoCATS procedures (χ2; p = 0.893 and 0.840). For ABBA and EndoCATS, 89.6% and 94.2% of patients were satisfied with the surgical procedure. Regarding QoL, there was an overall significant difference in distribution for physical, but not for mental health between groups (p < 0.001 and 0.658). Both endoscopic groups performed slightly worse regarding physical health, but without significant difference between the individual groups in post hoc multiple comparison. CONCLUSION: Endoscopic thyroid surgery is safe with comparable perioperative outcome in experienced high-volume centers. Patient satisfaction and cosmetic results are excellent; QoL is impaired in surgical patients, as they perform slightly worse compared to German standard cohort and non-surgical patients.


Asunto(s)
Calidad de Vida , Neoplasias de la Tiroides , Endoscopía/métodos , Femenino , Humanos , Estudios Prospectivos , Glándula Tiroides/cirugía , Neoplasias de la Tiroides/cirugía , Tiroidectomía/métodos , Resultado del Tratamiento
4.
Gastric Cancer ; 23(1): 11-22, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31228044

RESUMEN

BACKGROUND: Patients with peritoneal metastases of gastric cancer have a poor prognosis with a median survival of 7 months. A benefit of cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) could be shown in several selected patient cohorts but remains controversial. The aim of this study was, to reflect the results of a national German HIPEC registry initiated by the German Society of General and Visceral Surgery (DGAV). METHODS: The DGAV HIPEC registry StuDoQ|Peritoneum documents patients with peritoneal malignancy contributed from 52 hospitals. All consecutive documented patients from 2011 until 2016 (n = 3078) were treated with CRS and HIPEC and were analysed. A total of 315 (10%) suffered from gastric cancer and were analysed. RESULTS: A complete data set of 235 patients was available for this study, including 113 male (48.1%) and 122 female (51.9%) patients with a median age of 53.4 years (SD ± 11.9). The median PCI was 8.0 (range 1-30). A complete cytoreduction was achieved in 121 patients (71.6%). Postoperative complications (Clavien-Dindo grades 3-4) occurred in 40 patients (17%). The median overall survival (OS) time was 13 months. The 5-year survival rate was 6%. According to the PCI from 0-6 (n = 74); 7-15 (n = 70) and 16-39 (n = 24) the median OS differs significantly (18 months vs. 12 months vs. 5 months; p = 0.002). CONCLUSIONS: CRS and HIPEC in selected patients with gastric cancer and peritoneal spread can improve survival when they are treated in centers. An accurate staging and patient selection are of major importance to achieve long-term survival.


Asunto(s)
Neoplasias Peritoneales/secundario , Neoplasias Peritoneales/terapia , Neoplasias Gástricas/patología , Neoplasias Gástricas/terapia , Adulto , Antineoplásicos/uso terapéutico , Procedimientos Quirúrgicos de Citorreducción , Bases de Datos Factuales , Femenino , Alemania , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Neoplasias Peritoneales/mortalidad , Complicaciones Posoperatorias , Neoplasias Gástricas/mortalidad , Tasa de Supervivencia
5.
Langmuir ; 31(30): 8402-10, 2015 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-26153251

RESUMEN

Cell-free hemoglobin (Hb)-based oxygen carriers have long been proposed as blood substitutes but their clinical use remains tricky due to problems of inefficiency and/or toxicity. Conjugation of Hb with the biocompatible polymer poly(ethylene glycol) (PEG) greatly improved their performance. However, physiological data suggested a polymer molecular weight (Mw) threshold of about 10 kDa, beyond which the grafting of two PEG chains no longer improves efficiency and nontoxicity of diPEG/Hb conjugates. We used small-angle neutron scattering and contrast variation, which are the only techniques able to probe separately the conformation of PEG chains and Hb protein within the complex, to investigate the role of PEG chain conformation in diPEGylated Hb conjugates as a function of the polymer Mw. We found out that the structure of Hb tetramer is not modified by the polymer grafting. Similarly, with a constant grafting of two chains per protein, there is no significant change of the Gaussian conformation between free and grafted PEG below ∼10 kDa, the complex being well described by the "dumbbell" model. However, beyond that threshold, the radius of gyration of grafted PEG is significantly smaller than that of the free polymer, showing a compaction of the PEG chains, either in the "dumbbell" model or in the "shroud" one. In the latter model, the polymer may be wrapped on the surface of the protein spreading a protective "shielding" effect over a larger fraction of the protein. Both proposed models are in good agreement with the physiological data reported in the literature.


Asunto(s)
Hemoglobinas/química , Polietilenglicoles/química , Humanos , Modelos Moleculares , Conformación Molecular , Difracción de Neutrones , Dispersión del Ángulo Pequeño
6.
Nanoscale ; 5(9): 3969-75, 2013 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-23536023

RESUMEN

The mesostructure of ordered arrays of anisotropic nanoparticles is controlled by a combination of packing constraints and interparticle interactions, two factors that are strongly dependent on the particle morphology. We have investigated how the degree of truncation of iron oxide nanocubes controls the mesostructure and particle orientation in drop cast mesocrystal arrays. The combination of grazing incidence small-angle X-ray scattering and scanning electron microscopy shows that mesocrystals of highly truncated cubic nanoparticles assemble in an fcc-type mesostructure, similar to arrays formed by iron oxide nanospheres, but with a significantly reduced packing density and displaying two different growth orientations. Strong satellite reflections in the GISAXS pattern indicate a commensurate mesoscopic superstructure that is related to stacking faults in mesocrystals of the anisotropic nanocubes. Our results show how subtle variation in shape anisotropy can induce oriented arrangements of nanoparticles of different structures and also create mesoscopic superstructures of larger periodicity.

7.
Langmuir ; 28(23): 8791-8, 2012 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-22607150

RESUMEN

The phase separation mechanism in semidilute aqueous poly(N-isopropylacrylamide) (PNIPAM) solutions is investigated with small-angle neutron scattering (SANS). The nature of the phase transition is probed in static SANS measurements and with time-dependent SANS measurements after a temperature jump. The observed critical exponents of the phase transition describing the temperature dependence of the Ornstein-Zernike amplitude and correlation length are smaller than values from mean-field theory. Time-dependent SANS measurements show that the specific surface decreases with increasing time after a temperature jump above the phase transition. Thus, the formation of additional hydrogen bonds in the collapsed state is a kinetic effect: A certain fraction of water remains as bound water in the system. Moreover, H-D exchange reactions observed in PNIPAM have to be taken into account.


Asunto(s)
Acrilamidas/química , Polímeros/química , Agua/química , Resinas Acrílicas , Biotecnología , Enlace de Hidrógeno , Cinética , Difracción de Neutrones , Transición de Fase , Dispersión del Ángulo Pequeño , Soluciones , Temperatura , Termodinámica
8.
Nano Lett ; 11(4): 1651-6, 2011 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-21388121

RESUMEN

Grazing incidence small-angle scattering and electron microscopy have been used to show for the first time that nonspherical nanoparticles can assemble into highly ordered body-centered tetragonal mesocrystals. Energy models accounting for the directionality and magnitude of the van der Waals and dipolar interactions as a function of the degree of truncation of the nanocubes illustrated the importance of the directional dipolar forces for the formation of the initial nanocube clusters and the dominance of the van der Waals multibody interactions in the dense packed arrays.


Asunto(s)
Compuestos Férricos/química , Modelos Químicos , Modelos Moleculares , Nanoestructuras/química , Nanoestructuras/ultraestructura , Simulación por Computador , Transferencia de Energía , Sustancias Macromoleculares/química , Ensayo de Materiales , Conformación Molecular , Tamaño de la Partícula , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA