Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Intervalo de año de publicación
1.
Mycopathologia ; 179(3-4): 243-51, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25515245

RESUMEN

Infections caused by dermatophytes, mainly Trichophyton rubrum,are often vulnerable to relapses upon cessation of antifungal therapy, reinforcing the need of new antifungals. Aldimines have potential biological activities, but there are few reports on their antifungal profile. The aim of this study was to evaluate the antifungal activity of 2-(benzylideneamino)phenol (3A3) and 4-(benzylideneamino)phenol (3A4) against dermatophytes. We determined the minimum inhibitory concentration, minimum fungicidal concentration, time-kill curves and fractional inhibitory concentration of the combination of 3A3, 3A4 and itraconazole against a set of isolates of T. rubrum and T. interdigitale. 3A3 was tested in a murine model of dermatophytoses caused by T. rubrum, and the effect on phagocytosis was assessed. The MIC values ranged from 8 to 32 µg/mL for 3A3 and from 64 to 256 µg/mL for 3A4. The interaction between 3A3 and 3A4 with itraconazole proved to be synergistic and indifferent, respectively. 3A3 was as efficient as itraconazole in reducing the fungal burden on the skin of mice, being this effect associated with the influx of neutrophil and macrophage. Also, 3A3 was able to increase the internalization of conidia by macrophages. Altogether, our data encourage future clinical studies with 3A3 to treat dermatophytoses.


Asunto(s)
Antifúngicos/farmacología , Fenol/farmacología , Tiña/microbiología , Trichophyton/efectos de los fármacos , Animales , Antifúngicos/síntesis química , Antifúngicos/química , Femenino , Humanos , Masculino , Ratones , Ratones Endogámicos BALB C , Pruebas de Sensibilidad Microbiana , Fenol/química , Tiña/tratamiento farmacológico , Trichophyton/genética , Trichophyton/aislamiento & purificación , Trichophyton/fisiología
2.
J Pharm Biomed Anal ; 70: 544-8, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22673938

RESUMEN

Ofloxacin, second-generation fluoroquinolone derivative, is one of the most commonly used to treat and prevent superficial ocular infection in animals and human beings. However, poor bioavailability, rapid elimination, and non compliance by patients are several problems associated with ocular route. Ophthalmic controlled drug delivery offers the potential to enhance the efficacy of treatment for pathological conditions, while reducing the side effects and the toxicity associated with frequent applications. Specific analytical methods to determine drugs in eye are needed to analyze and compare the new controlled release ocular devices with those conventional eye drops. The topical eye administration of ophthalmic drugs induces lachrymation, and the tear promotes a drug wash out. Quantify drugs in tear is a good tool to study their kinetic comportment in the eye. A liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method for quantitation of ofloxacin in rabbits' tears was developed and validated. The tear was collected with tear strips, extracted by a liquid extraction procedure and then separated on an ACE C(18) column with a mobile phase composed of 0.15% aqueous formic acid and methanol (60:40, v/v). Calibration curve was constructed over the range of 10-5000 ng/mL for ofloxacin. The mean R.S.D. values for the intra-run and inter-run precision were 5.15% and 4.35%, respectively. The mean accuracy value was 100.16%. The validated method was successfully applied to determine the ofloxacin concentration in tears of rabbits treated with a mucoadhesive chitosan films and a conventional eye drop formulation.


Asunto(s)
Antibacterianos/administración & dosificación , Antibacterianos/farmacocinética , Quitosano/química , Cromatografía Líquida de Alta Presión , Ofloxacino/administración & dosificación , Ofloxacino/farmacocinética , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem , Lágrimas/metabolismo , Adhesividad , Administración Oftálmica , Animales , Antibacterianos/química , Calibración , Química Farmacéutica , Cromatografía Líquida de Alta Presión/normas , Preparaciones de Acción Retardada , Portadores de Fármacos , Formiatos/química , Límite de Detección , Masculino , Metanol/química , Modelos Animales , Ofloxacino/química , Soluciones Oftálmicas , Conejos , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masa por Ionización de Electrospray/normas , Espectrometría de Masas en Tándem/normas
3.
J Pharm Biomed Anal ; 61: 38-43, 2012 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-22178434

RESUMEN

A sensitive method for the determination of fluticasone in plasma was developed using high performance liquid chromatography with tandem mass spectrometric detection, whereas beclomethasone was used as internal standard. The analytes were extracted with a simple liquid-liquid extraction from the plasma samples and separated on an ACE C(18) 50 × 4.6 mm i.d.; 5 µm particle size column with a mobile phase consisting of acetonitrile - 0.01% formic acid (48:52, v/v) at a flow rate of 1 ml/min. Detection was achieved by an Applied Biosystems API 5000 mass spectrometer (LC-MS/MS) set at unit resolution in the multiple reaction monitoring mode. Atmospheric pressure chemical ionization (APCI) was used for ion production. The mean recovery for fluticasone propionate was 85%, with a lower limit of quantification set at 2 pg/mL. The validated analytical method was applied to a bioequivalence study of fluticasone propionate administered by nasal spray formulations in human volunteers.


Asunto(s)
Androstadienos/sangre , Presión Atmosférica , Espectrometría de Masas/métodos , Rociadores Nasales , Adulto , Androstadienos/química , Química Farmacéutica , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Líquida de Alta Presión/normas , Cromatografía Liquida/métodos , Cromatografía Liquida/normas , Estudios Cruzados , Femenino , Fluticasona , Humanos , Masculino , Espectrometría de Masas/normas , Espectrometría de Masas en Tándem/métodos , Espectrometría de Masas en Tándem/normas , Equivalencia Terapéutica , Factores de Tiempo
4.
Biomed Chromatogr ; 26(7): 851-6, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22031460

RESUMEN

A rapid method for the quantification of glucosamine in human plasma using high-performance liquid chromatography coupled to tandem mass spectrometry was developed and validated. The sample preparation includes a simple deproteinization step, using D-[1-¹³C] glucosamine hydrochloride as an internal standard. Chromatographic separation was performed on an ACE Ciano column using isocratic elution with acetonitrile and aqueous 2 mM ammonium acetate containing 0.025% formic acid (80:20). Selected reaction monitoring was performed using the transitions m/z 180.1 → m/z 72.1 and m/z 181.0 → m/z 74.6 to quantify glucosamine and internal standard, respectively. The method was validated and proved to be linear, accurate and precise over the range 50-5000 ng/mL of glucosamine. Recovery rates higher than 90% were obtained for both glucosamine and internal standard. No matrix effect was detected in the samples. The validated method was successfully applied to a pharmacokinetic study after oral administration of a powder for oral solution formulation containing glucosamine sulfate.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Glucosamina/sangre , Espectrometría de Masas en Tándem/métodos , Administración Oral , Femenino , Glucosamina/administración & dosificación , Glucosamina/farmacocinética , Humanos , Masculino , Polvos/administración & dosificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
J Mass Spectrom ; 46(9): 943-8, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21915959

RESUMEN

A sensitive and fast high-performance liquid chromatography-electrospray ionization-MS/MS method for the simultaneous quantitation of levodopa and carbidopa in human plasma was developed and validated. A simple protein precipitation step with perchloric acid was used for the cleanup of plasma, and methyldopa was added as an internal standard. The analyses were carried out using an ACE C(18) column (50 × 4.6 mm i.d.; 5 µm particle size) and a mobile phase consisting of 0.2% formic acid and acetonitrile (90:10). The triple-quadrupole mass spectrometer equipped with an electrospray source in positive mode was set up in the selective reaction monitoring mode to detect the ion transitions m/z 198.1 → m/z 107.0, m/z 227.2 → m/z 181.0, and m/z 212.1 → m/z 139.2 for levodopa, carbidopa, and methyldopa, respectively. The method was validated and proved to be linear, accurate, and precise over the range 50-5000 ng/mL for levodopa and 3-600 ng/mL for carbidopa. The proposed method was successfully applied in a pharmacokinetic study with a levodopa/carbidopa tablet formulation in healthy volunteers.


Asunto(s)
Carbidopa/sangre , Cromatografía Líquida de Alta Presión/métodos , Levodopa/sangre , Espectrometría de Masas en Tándem/métodos , Administración Oral , Carbidopa/administración & dosificación , Carbidopa/farmacocinética , Estabilidad de Medicamentos , Femenino , Humanos , Levodopa/administración & dosificación , Levodopa/farmacocinética , Masculino , Metildopa/sangre , Metildopa/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Comprimidos/administración & dosificación , Comprimidos/farmacocinética
6.
J Pharm Biomed Anal ; 56(5): 1094-100, 2011 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-21856105

RESUMEN

A sensitive and simple method was developed for the quantitation of levodopa and its metabolite 3-O-methyldopa, in human plasma, after oral administration of tablet formulations containing levodopa (200 mg) and benserazide (50 mg). The analytes were extracted by a protein precipitation procedure, using carbidopa as an internal standard. A mobile phase consisting of 0.2% formic acid and acetonitrile (94:6, v/v) was used and chromatographic separation was achieved using ACE C(18) column (50 mm×4.6 mm i.d.; 5 µm particle size). Selected reaction monitoring was performed using the fragmentation transitions m/z 198→m/z 107, m/z 212→m/z 166 and m/z 227→m/z 181 for levodopa, 3-O-methyldopa and carbidopa, respectively. Calibration curves were constructed over the range 50.0-6000.0 ng/mL for levodopa and 25.0-4000.0 ng/mL for 3-O-methyldopa. The method shown to be specific, precise, accurate and provided recovery rates higher than 85% for all analytes. No matrix effect was detected in the samples. The validated method was applied in a pharmacokinetic study with a levodopa/benserazide tablet formulation in healthy volunteers.


Asunto(s)
Benserazida/sangre , Cromatografía Líquida de Alta Presión/métodos , Levodopa/sangre , Metildopa/sangre , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos , Benserazida/farmacocinética , Calibración , Humanos , Levodopa/farmacocinética , Metildopa/farmacocinética , Control de Calidad , Reproducibilidad de los Resultados , Comprimidos
7.
J Mass Spectrom ; 46(3): 320-6, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21394848

RESUMEN

A liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method for the quantitation of triamcinolone in human plasma after nasal spray application was developed and validated. Betamethasone was used as internal standard (IS). The analytes were extracted by a liquid-liquid procedure and separated on a Zorbax Eclipse XDB C(18) column with a mobile phase composed of 2 mM aqueous ammonium acetate pH 3.2 and acetonitrile (55:45). Selected reaction monitoring was performed using the transitions m/z 435 → 415 and m/z 393 → 373 to quantify triamcinolone acetonide and betamethasone, respectively. Calibration curve was constructed over the range of 20-2000 pg/ml for triamcinolone acetonide. The lower limit of quantitation was 20 pg/ml. The mean RSD values were 4.6% and 5.7% for the intra-run and inter-run precision, respectively. The mean accuracy value was 98.5% and a recovery rate corresponding to 97.5% was achieved. No matrix effect was detected in the samples. The validated method was successfully applied to determine the plasma concentrations of triamcinolone acetonide in healthy volunteers, in a pharmacokinetic study with nasal spray formulation.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Triamcinolona/sangre , Betametasona , Humanos , Modelos Lineales , Rociadores Nasales , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem/métodos , Triamcinolona/administración & dosificación , Triamcinolona/farmacocinética
8.
Arq Bras Oftalmol ; 72(4): 444-50, 2009.
Artículo en Portugués | MEDLINE | ID: mdl-19820781

RESUMEN

PURPOSE: The present study aimed to evaluate an injectable extended-release formulation of prednisolone acetate (PA) for orbital administration. METHODS: Microspheres (MEs) of poly-e-caprolactone (PCL) containing PA were developed by the method of solvent evaporation. The MEs obtained were characterized by scanning electron microscopy (SEM), differential scanning calorimetry (DSC), encapsulation efficiency and in vitro release profile. The in vivo release profile was evaluated in rabbits after periocular injection of an aqueous suspension of MEs. The local biocompatibility of the system was verified by histopathologic analysis of the deployment region. RESULTS: After MEs preparation, morphological analysis by SEM showed the feasibility of the employed method. The content of PA encapsulated was 43+/-7% and can be considered as satisfactory. The system characterization by DSC technique, in addition to confirm the system stability, did not indicate the existence of interaction between the drug and the polymer. The in vitro release study showed the prolonged-release features of the developed system. Preliminary in vivo study showed the absence of local toxicity and confirmed the prolonged release profile of PA from MEs, suggesting the viability of the developed system for the treatment of orbital inflammatory diseases. CONCLUSION: The results obtained in this work are relevant and accredit the system developed as a possible alternative to the treatment of inflammatory orbitopathy.


Asunto(s)
Antiinflamatorios/administración & dosificación , Materiales Biocompatibles/química , Prednisolona/análogos & derivados , Cuerpo Vítreo/efectos de los fármacos , Animales , Rastreo Diferencial de Calorimetría , Preparaciones de Acción Retardada/administración & dosificación , Portadores de Fármacos/administración & dosificación , Femenino , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Microesferas , Poliésteres/administración & dosificación , Prednisolona/administración & dosificación , Conejos
9.
Arq. bras. oftalmol ; 72(4): 444-450, July-Aug. 2009. ilus, graf, tab
Artículo en Portugués | LILACS | ID: lil-528007

RESUMEN

OBJETIVO: O presente estudo objetivou o desenvolvimento e a avaliação de um sistema biodegradável de liberação de fármacos com característica de liberação prolongada, destinado à administração orbitária de acetato de prednisolona (AP). MÉTODOS: O sistema desenvolvido, na forma de microesferas (MEs) de poli-e-caprolactona (PCL) contendo o AP, foi obtido pelo método de evaporação de solvente. As MEs foram caracterizadas por microscopia eletrônica de varredura (MEV), calorimetria diferencial exploratória (DSC), avaliação do teor de encapsulação e pelo perfil de liberação in vitro. O perfil de liberação in vivo foi avaliado em coelhos após administração peribulbar de uma suspensão aquosa das MEs. A biocompatibilidade local do sistema foi verificada por meio de análise histopatológica da região de implantação. RESULTADOS: Após obtenção das MEs, a análise morfológica por MEV mostrou a viabilidade do método de obtenção do sistema. O teor de AP encapsulado foi de 43 ± 7 por cento e pode ser considerado bastante satisfatório. A caracterização do sistema por DSC, além de confirmar a sua estabilidade, não indicou a existência de interação entre o fármaco e o polímero. O estudo de liberação in vitro indicou que o sistema apresenta perfil de liberação prolongada. O estudo in vivo confirmou o perfil de liberação prolongado do AP a partir das MEs, sugerindo, também, a viabilidade do sistema devido à ausência de toxicidade local. CONCLUSÃO: O conjunto dos resultados obtidos neste trabalho é relevante e credencia o sistema desenvolvido como uma possível alternativa ao tratamento de orbitopatias inflamatórias.


PURPOSE: The present study aimed to evaluate an injectable extended-release formulation of prednisolone acetate (PA) for orbital administration. METHODS: Microspheres (MEs) of poly-e-caprolactone (PCL) containing PA were developed by the method of solvent evaporation. The MEs obtained were characterized by scanning electron microscopy (SEM), differential scanning calorimetry (DSC), encapsulation efficiency and in vitro release profile. The in vivo release profile was evaluated in rabbits after periocular injection of an aqueous suspension of MEs. The local biocompatibility of the system was verified by histopathologic analysis of the deployment region. RESULTS: After MEs preparation, morphological analysis by SEM showed the feasibility of the employed method. The content of PA encapsulated was 43 ± 7 percent and can be considered as satisfactory. The system characterization by DSC technique, in addition to confirm the system stability, did not indicate the existence of interaction between the drug and the polymer. The in vitro release study showed the prolonged-release features of the developed system. Preliminary in vivo study showed the absence of local toxicity and confirmed the prolonged release profile of PA from MEs, suggesting the viability of the developed system for the treatment of orbital inflammatory diseases. CONCLUSION: The results obtained in this work are relevant and accredit the system developed as a possible alternative to the treatment of inflammatory orbitopathy.


Asunto(s)
Animales , Femenino , Conejos , Antiinflamatorios/administración & dosificación , Materiales Biocompatibles/química , Prednisolona/análogos & derivados , Cuerpo Vítreo/efectos de los fármacos , Rastreo Diferencial de Calorimetría , Preparaciones de Acción Retardada/administración & dosificación , Portadores de Fármacos/administración & dosificación , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Microesferas , Poliésteres/administración & dosificación , Prednisolona/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...