Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Intervalo de año de publicación
1.
Rev Col Bras Cir ; 42(1): 43-8, 2015.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-25992700

RESUMEN

OBJECTIVE: to verify the effectiveness of coconut water in preserving tissues for transplant. METHODS: Fifty male Wistar rats were randomly distributed in five groups, according to the following preservation solutions for tissue grafts: Group 1: Lactated Ringer; Group 2: Belzer solution; Group 3: mature coconut water; Group 4: green coconut water; Group 5: modified coconut water. In Group 5, the green coconut water has been modified like the Belzer solution. From each animal we harvested the spleen, ovaries and skin of the back segment. These tissues were preserved for six hours in one of the solutions. Then, the grafts were reimplanted. The recovery of the function of the implanted tissues was assessed 90 days after surgery, by splenic scintigraphy and blood exam. The implanted tissues were collected for histopathological examination. RESULTS: The serum levels did not differ among groups, except for the animals in Group 5, which showed higher levels of IgG than Group 1, and differences in relation to FSH between groups 1 and 2 (p <0.001), 4 and 2 (p = 0.03) and 5 and 2 (p = 0.01). The splenic scintigraphy was not different between groups. The ovarian tissue was better preserved in mature coconut water (p <0.007). CONCLUSION: the coconut water-based solutions preserves spleen, ovary, and rat skin for six hours, maintaining their normal function.


Asunto(s)
Cocos , Soluciones Preservantes de Órganos , Trasplante de Órganos , Animales , Masculino , Distribución Aleatoria , Ratas , Ratas Wistar
2.
Rev. Col. Bras. Cir ; 42(1): 43-48, Jan-Feb/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-746247

RESUMEN

OBJECTIVE: To verify the effectiveness of coconut water in preserving tissues for transplant. METHODS: Fifty male Wistar rats were randomly distributed in five groups, according to the following preservation solutions for tissue grafts: Group 1: Lactated Ringer; Group 2: Belzer solution; Group 3: mature coconut water; Group 4: green coconut water; Group 5: modified coconut water. In Group 5, the green coconut water has been modified like the Belzer solution. From each animal we harvasted the spleen, ovaries and skin of the back segment. These tissues were preserved for six hours in one of the solutions. Then, the grafts were reimplanted. The recovery of the function of the implanted tissues was assessed 90 days after surgery, by splenic scintigraphy and blood exame. The implanted tissues were collected for histopathological examination. RESULTS: The serum levels did not differ among groups, except for the animals in Group 5, which showed higher levels of IgG than Group 1, and differences in relation to FSH between groups 1 and 2 (p <0.001), 4 and 2 (p = 0.03) and 5 and 2 (p = 0.01). The splenic scintigraphy was not different between groups. The ovarian tissue was better preserved in mature coconut water (p <0.007). CONCLUSION: the coconut water-based solutions preserves spleen, ovary, and rat skin for six hours, maintaining their normal function.


OBJETIVO: Verificar a eficácia da água de coco na preservação de tecidos para transplante. MÉTODOS: cinquenta ratas Wistar foram distribuídas aleatoriamente em cinco grupos, de acordo com as seguintes soluções de preservação para enxertos teciduais: Grupo 1- Ringer lactato, Grupo 2- Solução de Belzer, Grupo 3- Água de coco maduro, Grupo 4- Água de coco verde, Grupo 5- Água de coco modificada. No Grupo 5, a água de coco verde foi modificada à semelhança da solução de Belzer. De cada animal, retirou-se o baço, os ovários e um segmento de pele do dorso. Esses tecidos foram preservados durante seis horas em uma das soluções. Em seguida, os enxertos foram reimplantados. A recuperação da função dos tecidos implantados foi avaliada 90 dias após a cirurgia, por meio de cintilografia esplênica, exames de sangue. Os tecidos implantados foram coletados para estudo anatomopatológico. RESULTADOS: as dosagens séricas não apresentaram diferença entre os cinco grupos, exceto pelos animais do Grupo 5, que apresentaram valores mais elevados de IgG do que o Grupo 1,e pelas diferenças em relação ao FSH entre os grupos 1 e 2 (p<0,001), 4 e 2 (p=0,03), 5 e 2 (p=0,01). A cintilografia esplênica não foi diferente entre os grupos. O tecido ovariano foi melhor preservado em água de coco maduro (p<0,007). CONCLUSÃO: as soluções à base de água de coco preservam baço, ovário e pele de rato durante seis horas, mantendo sua função normal.


Asunto(s)
Humanos , Cocos , Soluciones Preservantes de Órganos , Ovario , Piel , Bazo , Trasplante
3.
J Surg Res ; 144(1): 89-93, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17936794

RESUMEN

BACKGROUND: Duodenal injury occurs in 3% to 12% of patients with abdominal trauma. The best procedure to treat major duodenal ruptures continues to be a challenge. The purpose of the present study was to analyze differences between the time of gastroduodenal pylorus reopening after its closure with different suture materials and to verify the influence of vagotomy on local tissue changes. METHODS: Thirty rats were submitted to closure of the gastroduodenal pylorus and gastrojejunal anastomosis. The animals were divided into three groups (n = 10) according to the type of suture material used: plain catgut, polyglycolic acid, and polypropylene. Half of the animals in each group (n = 5) were also submitted to truncal vagotomy. Postoperative assessment included weekly abdominal X-ray following intragastric contrast injection until re-establishment of the gastroduodenal transit or for a maximum period of 4 wk. At the end of the follow-up period, the pyloric regions and the gastrojejunal anastomosis were removed for histological analysis. The groups were compared by the Kaplan-Meier test, with the level of significance set at P < 0.05. RESULTS: The polypropylene suture maintained the pylorus closed for a longer period of time (36.3 +/- 11.6 d) (P < 0.05). No difference was observed between the polyglycolic acid suture (25.8 +/- 14.2 d) and the plain catgut suture (18.7 +/- 10.2 d). Vagotomy did not influence the time of pyloric reopening, but was associated with a less intense gastric inflammatory reaction. CONCLUSIONS: The nonabsorbable suture was the most adequate for exclusion of pyloric transit. Vagotomy had no influence on the time of pyloric reopening but reduced gastric inflammation.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo/métodos , Duodeno/lesiones , Duodeno/cirugía , Píloro/cirugía , Vagotomía , Anastomosis Quirúrgica/métodos , Animales , Catgut , Ácido Gástrico , Yeyuno/patología , Yeyuno/cirugía , Ácido Poliglicólico , Polipropilenos , Complicaciones Posoperatorias/prevención & control , Ratas , Ratas Sprague-Dawley , Rotura/cirugía , Técnicas de Sutura , Úlcera/prevención & control , Cicatrización de Heridas
4.
Rev. Col. Bras. Cir ; 32(6): 328-331, nov.-dez. 2005.
Artículo en Portugués | LILACS | ID: lil-423404

RESUMEN

OBJETIVOS: A lesão duodenal é um evento pouco freqüente, que incide em 3 por cento a 12 por cento dos pacientes com trauma de abdome. A sutura dessa ferida e a drenagem adequada da região é o tratamento mais utilizado nas lesões menores. Entretanto, as feridas de maior dimensão continuam sendo um desafio para a escolha do melhor tratamento. O fechamento do piloro e o desvio do trânsito digestório por meio de anastomose gastrojejunal é a conduta mais freqüente nessas situações. Os objetivos deste estudo foram verificar se há diferença entre o tempo de reabertura pilórica após sua oclusão com diferentes fios e se a vagotomia influencia nas alterações tissulares locais. MÉTODO: Foram estudados 30 ratos, submetidos à cerclagem do piloro gastroduodenal e derivação gastrojejunal. Os animais foram divididos em três grupos (n = 10), de acordo com o tipo de fio utilizado no fechamento pilórico: categute simples, ácido poliglicólico e polipropileno. Metade dos animais de cada grupo (n = 5) foram também submetidos a vagotomia troncular. O estudo pós-operatório consistiu de radiografia abdominal após injeção intragástrica de contraste baritado, semanalmente até a constatação de trânsito gastroduodenal. Em seguida, as regiões pilórica e da anastomose gastrojejunal foram retiradas para análise histológica. A comparação entre os grupos foi feita pelo teste de Kaplan-Meier. RESULTADOS: O fio de polipropileno manteve o piloro fechado por mais tempo (36,3 ± 11,6 dias) em relação aos demais fios (p <0,05), não havendo diferença entre os fios de ácido poliglicólico (25,8 ± 14,2 dias) e categute simples (18,7 ± 10,2 dias). A vagotomia não influenciou no tempo de reabertura pilórica, mas acompanhou-se de menor reação inflamatória gástrica. CONCLUSÕES: O fio inabsorvível foi o mais adequado para a exclusão do trânsito pilórico e a vagotomia não influenciou no tempo de reabertura pilórica, mas reduziu a intensidade da gastrite pós-operatória.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA