Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Medicina (Kaunas) ; 59(5)2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37241150

RESUMEN

Background and Objectives: The aim of this study was to compare the accuracy of three types of electronic apex locators (EALs) when two different concentrations of NaOCl irrigation solutions are used by two operators. Materials and Methods: After creating the access cavities for 20 single rooted extracted teeth, the actual canal length (ACL) of each canal was determined visually using a #10 file and magnification. The teeth were subsequently inserted in plastic molds filled with alginate. The electronic measurement of root canal length (EWL) was performed using three different electronic apex locators: Root ZX II, Apex ID, and Dual Pex. Two independent operators, an endodontic specialist with 20 years practice and an undergraduate student in the final year of study, performed the irrigation procedures with two different concentrations of NaOCl (2% and 5.25%), and then measured the EWL using each of the EALs. The accuracy of all EALs, was determined in each case by subtracting the EWL from the ACL. Statistical analyses were performed using one-way ANOVA test. Results: In the presence of 2% NaOCl solution, for a margin error of ±0.5 mm, Root ZX II, Apex ID, and Dual Pex presented an accuracy of 90%, 80%, and 85% respectively. The increase in the concentration of the irrigation solution affected the accuracy of Root ZX II and Apex ID for both operators, diminishing it to 75% for the same margin error, but improved Dual Pex's accuracy to 100%. Conclusions: The best accuracy in working length determination was obtained by Root ZX II for 2% NaOCl solution and by Dual Pex for 5.25% NaOCl solution with no significant statistical difference when compared.


Asunto(s)
Hipoclorito de Sodio , Ápice del Diente , Humanos , Preparación del Conducto Radicular/métodos , Odontometría , Electrónica
2.
Materials (Basel) ; 15(19)2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36234029

RESUMEN

This study aimed to evaluate the antibacterial effect of three final irrigation protocols and to compare their ability to remove the smear layer and debris from the root canal. Methods: Sixty-three single-rooted human teeth were inoculated with Enterococcus faecalis for 14 days. The teeth were divided into a positive control group (N = 3) and three treatment groups (N = 20) as follows: final irrigation with saline solution (control group), irrigation with 5.25% NaOCl ultrasonically activated with EndoUltra (EU), standard needle irrigation with Qmix 2in1 (Qx) and irrigation with 5.25% NaOCl activated using SiroLaser Blue (SB). The bacterial load was evaluated by analyzing the colony-forming units (CFU/mL). Selected specimens were split longitudinally and examined using scanning electron microscopy in order to determine the presence of a smear layer and debris. Statistical analyses were performed using one-way ANOVA and the Kruskal−Wallis rank-sum test. Results: Activation of NaOCl with EndoUltra or SiroLaser Blue was superior at reducing intracanal bacteria relative to standard needle irrigation with Qmix 2in1 solution (p < 0.05). Even though SiroLaser Blue showed the best results for removing the smear layer and debris, no significant differences were detected between the groups (p > 0.05). Conclusions: Final irrigation with 5.25% NaOCl ultrasonically activated using EndoUltra or SiroLaser Blue demonstrated a higher efficacy in bacterial reduction than standard needle irrigation with Qmix 2in1.

3.
Materials (Basel) ; 15(14)2022 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-35888436

RESUMEN

The purposes of the study were to evaluate the influence of the sealer's chemical composition on the interfacial strength between root canal dentin and root filling material, for two different classes of endodontic sealers, and to assess their failure modes. Methods: Forty extracted single-rooted teeth were randomly divided into four groups using the following endodontic sealers: RealSeal SE and Resilon (RSSE); EndoSequence BC sealer and BC Point (EBCS); Endoseal MTA and gutta-percha (EDS); Bioroot RCS and gutta-percha (BRS). Teeth were embedded in acrylic resin, and the roots were sectioned horizontally into 1 mm slices. For each slice, the perimeter was measured. A push-out test was performed using an Instron universal testing machine. For each sample, bond strength was calculated. Specimens were examined by SEM investigation in order to analyze the dentin−sealer−core interface. Results were assessed using analysis of variance (ANOVA) and Tukey and Bonferroni test. Results: Statistical analysis revealed that EDS and gutta-percha had significantly higher resistance to dislodgement compared to the other three groups (p < 0.05). EBCS and BC Point showed significantly greater push-out bond strength values compared to RSSE and Resilon (p < 0.05). Conclusions: Bioceramic endodontic sealers showed a higher bond strength to root dentin than methacrylate resin-based endodontic sealer.

4.
Artículo en Inglés | MEDLINE | ID: mdl-35682470

RESUMEN

The intent of the KAP (knowledge, attitude, practices) survey is to collect information about a specific target group related to their knowledge, what they consider to be known, and what they do about a particular topic. The aim of this study was to identify the level of importance of oral health, especially the level of knowledge, attitude and practices of rural patients around Cluj-Napoca, Romania. MATERIAL AND METHODS: A questionnaire consisting of five parts was used, trying to assess the self-perception of oral health, knowledge and attitude towards oral health, dental hygiene practices and eating habits. A clinical examination was also performed in order to identify the number of missing teeth, the caries and the presence of calculus. RESULTS: The study revealed that most patients have an average and good self-perception of oral health, although three-quarters of them have calculus deposits, and about half of them have more than three carious lesions and at least one extracted tooth. There is also a discrepancy between declared knowledge of oral health, eating habits and dental practices. CONCLUSIONS: The basic knowledge of rural patients about oral health can be considered satisfactory, but the practices, unfortunately, do not reflect this knowledge.


Asunto(s)
Cálculos , Caries Dental , Estudios Transversales , Caries Dental/epidemiología , Conocimientos, Actitudes y Práctica en Salud , Humanos , Salud Bucal , Rumanía
5.
Materials (Basel) ; 15(3)2022 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-35160748

RESUMEN

The aim of the present study was to obtain experimental infiltration materials, intended for the treatment of dental white spots, and to investigate them. Two series of infiltrants (P1-P6)/(P1F-P6F) were obtained, based on different monomer mixtures, without/with glass filler (with fluoride release ability). Each infiltrant from the second series contained the same amount of glass powder, and each infiltrant from the (P-PF) group contained the same resin composition. The characteristics of the experimental infiltrants were investigated by degree of conversion (DC), mechanical strength, water sorption (WS), and fluoride release, in addition to residual monomer for (P1F-P6F) infiltrants. The results were compared with those obtained for commercial Icon infiltrant. For the experimental infiltrants, without/with filler, the recorded DC was in the range of 58.27-89.70%/60.62-89.99%, compared with Icon (46.94%) 24 h after polymerization. The release of fluoride depends on the permeability of the polymer matrix, with respect to the water sorption, which may help to diffuse ions in the storage medium but which can also influence the release of residual monomers. The highest flexural strengths were recorded for the (TEGDMA/HEMA/Bis-GMA) infiltrants (133.94 ± 16.389 MPa/146.31 ± 7.032 MPa). The best experimental infiltrants were P2 and P2F (Bis-GMA/HEMA/TEGDMA).

6.
Rom J Morphol Embryol ; 59(2): 499-503, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30173254

RESUMEN

ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland) (PTN) and One Shape New Generation (MicroMéga, Besançon, France) (OSNG) belong to a relatively new generation of rotary nickel-titanium (NiTi) files. Scientists keep improving features of endodontic files in order to obtain anatomically shaped and cleaned root canals and avoid canal transportation, for a better outcome of the endodontic treatment. For the current study, the aim was to evaluate and assess the changes in root canal morphology after instrumentation with PTN and OSNG by using micro-computed tomography (CT). This high-tech resolution tomography allows a much more detailed analysis of the root canal anatomy and its transformation after rotary instrumentation. We have selected 10 mandibular molars; before and after canal preparation, the samples were distributed in two homogeneous groups (PTN and OSNG groups) and submitted to standardized radiographs and micro-CT (SkyScan1172, Kontich, Belgium). From the three-dimensional (3D) images obtained from the scanning, we were able to perform a two-dimensional (2D) (perimeter, area and roundness), respectively a 3D (volume, surface area, structure model index) analysis, before and after root canal instrumentation. Results did not revealed important statistical differences among the two groups in relation to the curvature and volume of the root canals before instrumentation; after rotary instrumentation, there was a substantially increase of volume and surface area for all the samples (p<0.05). The two types of instruments preserved the original canal path, maintaining a continuous, safe and adequate shape and taper of the root canals.


Asunto(s)
Diente Molar/diagnóstico por imagen , Preparación del Conducto Radicular/métodos , Tratamiento del Conducto Radicular/métodos , Microtomografía por Rayos X/métodos , Humanos
7.
J Esthet Restor Dent ; 28 Suppl 1: S46-55, 2016 03.
Artículo en Inglés | MEDLINE | ID: mdl-26923662

RESUMEN

OBJECTIVE: To determine the shade correspondence between human dentine and two versions of a CAD/CAM hybrid ceramic system and to investigate color and translucency differences between these materials. MATERIALS AND METHODS: Twenty-four samples of different shades and opacities were fabricated from Vita Enamic CAD/CAM ceramic blocks. Human dentine samples were obtained from 73 extracted maxillary teeth. Color coordinates of all samples were measured using VitaEasyshade spectrophotometer. The translucency parameter (TP) and ΔEab* and ΔE00 color differences, with respect to human dentine of anterior and posterior teeth, were calculated. RESULTS: Vita Enamic Translucent was the best match for anterior teeth (>90% of cases) while Vita Enamic T 3M2 was the best option for the dentine samples of posterior teeth in 78.8% ( ΔEab*) and 54.5% ( ΔE00) of the cases. The smallest differences in translucency ( ΔTP) with the dentine samples of anterior teeth were obtained for Vita Enamic T 3M2 (92.5%) and with those of posterior teeth for Vita Enamic HT 1M2 (45.4%). CONCLUSIONS: VITA Enamic Translucent is the best option as color match for both anterior and posterior teeth dentine. In terms of translucency, VITA Enamic Translucent closely matched anterior teeth dentine while for posterior teeth, VITA Enamic HT was the best option. CLINICAL SIGNIFICANCE: The results of the present study could help clinicians in their decision of choosing a specific shade and translucency for their anterior or posterior esthetic restorations with hybrid ceramics. (J Esthet Restor Dent 28:S46-S55, 2016).


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Porcelana Dental , Color , Dentina , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...