1.
Eur J Ophthalmol ; 30(6): 1261-1267, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31432704

RESUMEN

PURPOSE: To evaluate the intrasession repeatability and validity of posterior corneal curvature and astigmatism measurements provided by a color light-emitting diode reflection topography system in healthy eyes. METHODS: A total of 40 healthy eyes of 40 patients (age, 16-66 years) were enrolled. A complete eye examination was performed in all cases including posterior topographic analysis with two systems: the Scheimpflug-based system (Pentacam; Oculus Optikgeräte GmbH, Wetzlar, Germany) and the Cassini system (i-Optics; Ophthec, The Hague, The Netherlands). With this last system, three consecutive measurements were taken to assess the level of intrasession repeatability (within-subject standard deviation, Sw; intraclass correlation coefficient). The Bland & Altman analysis was used to evaluate the interchangeability of both devices. RESULTS: The Sw was ⩽0.06 mm for all posterior corneal radius measurements, with intraclass correlation coefficient of ⩾0.960. The Sw for the magnitude of astigmatism, J0, and J45 were 0.15, 0.04, and 0.04 D, respectively, with intraclass correlation coefficient values of 0.876, 0.897, and 0.840, respectively. Statistically significant differences between devices were found in all parameters evaluated (p ⩽ 0.025). The interchangeability analysis revealed the presence of clinically relevant limits of agreement for the flattest (0.03 to 0.50 mm) and steepest posterior corneal radii (-0.01 to 0.39 mm). In contrast, limits of agreements were not clinically relevant for the magnitude of posterior astigmatism (-0.17 to 0.27 D) and their power vector components (-0.11 to 0.15 D). CONCLUSION: The Cassini system provides consistent measures of posterior corneal curvature and astigmatism in healthy eyes, but only measures of posterior astigmatism can be considered as interchangeable with those provided by the Pentacam.


Asunto(s)
Astigmatismo/diagnóstico , Córnea/anatomía & histología , Topografía de la Córnea/instrumentación , Adolescente , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
2.
Graefes Arch Clin Exp Ophthalmol ; 257(11): 2437-2447, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31482276

RESUMEN

PURPOSE: To evaluate the intrasession repeatability of anterior corneal topographic and aberrometric measurements provided by a color-LED topographer as well as their interchangeability with those provided by a Scheimpflug-based system in healthy eyes. METHODS: Thirty-five healthy eyes of 35 patients (age, 16-66 years) were enrolled. A complete eye examination was performed in all cases including a complete corneal analysis with the Scheimpflug-based system Pentacam (Oculus Optikgeräte) (one measurement) and the Cassini system (i-Optics) (three consecutive measurements). Intrasession repeatability of the Cassini measurements was assessed with the within-subject standard deviation (Sw) and the intraclass correlation coefficient (ICC). The Bland-Altman analysis was used to evaluate the agreement between both devices. RESULTS: Mean Sw for keratometric readings was 0.02 mm (ICC ≥ 0.992), ranging between 0.16 and 0.05 D (ICC 0.930-0.978) for anterior and total astigmatic measurements. Mean Sw for asphericity and corneal diameter were 0.06 (ICC 0.926) and 0.03 mm (IC 0.997), respectively. Aberrometric parameters showed ICCs ≥ 0.816, except for Z42 (ICC 0.741) and Z44 (ICC 0.544). When comparing devices, statistically significant differences were found for most of topographic and aberrometric data (p ≤ 0.044). Likewise, ranges of agreement between devices were clinically relevant (keratometry > 0.06 mm; total astigmatic components > 0.69 D; asphericity 0.35; second-, third-, and fourth-order Zernike terms, more than 0.20, 0.13, and 0.01 µm, respectively). CONCLUSIONS: Consistent anterior corneal topographic, total corneal astigmatic, and aberrometric measurements are obtained with color-LED topography in healthy eyes, which are not interchangeable with those provided by the Scheimpflug-based topography.


Asunto(s)
Aberrometría/métodos , Córnea/citología , Adolescente , Adulto , Anciano , Topografía de la Córnea/métodos , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
3.
Index enferm ; 28(1/2): 28-32, ene.-jun. 2019. tab
Artículo en Español | IBECS | ID: ibc-184979

RESUMEN

Objetivo principal: Conocer la percepción de las personas sobre la repercusión del contexto político en su salud. Metodología: Se realizó un estudio cualitativo. Participaron cinco usuarios del Centro de Atención Primaria Raval Nord en Barcelona que verbalizaron en consulta malestar físico y emocional relacionado con el contexto político. Se realizaron entrevistas semiestructuradas, preservando el rigor científico mediante la triangulación del investigador. Resultados principales: Todos los participantes manifestaron malestar emocional y físico que relacionaron con incertidumbre y desconfianza hacia las instituciones políticas. Refirieron diferentes tipos de afrontamiento; la evitación fue el más utilizado entre otros como la resignación, la socialización o la implicación. Conclusión principal: Los participantes perciben su salud biopsicosocial afectada por la crisis política. Identifican el contexto político como principal estresor. La integración en la práctica profesional de la dimensión social y la percepción de salud de la persona debe ser una realidad, y es esencial para un cuidado holístico y de calidad


Objective: Get to know people's perception about the consequences of the political context on their own health. Methods: A qualitative study was conducted. Five users of the Raval Nord Primary Care Center in Barcelona city, who during consultation verbalized physical and emotional discomfort related to the political context. Semi-structured interviews were carried out, preserving scientific rigor through the triangulation of the researcher. Results: All participants expressed emotional and physical discomfort related to uncertainty and distrust towards political institutions. They manifested different types coping strategies; avoidance was the most used among others as resignation, socialization and involvement were also described. Conclusions: Participants perceive their biopsychosocial health as affected by the political crisis. They identify the political context as the main stressor. The social dimension and the person health's perception must be integrated into the professional practice, and it is essential for a holistic quality care


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Percepción , Salud Holística , Actitud Frente a la Salud , Política de Salud , Enfermería Holística , Adaptación Psicológica , Conductas Relacionadas con la Salud
4.
Optom Vis Sci ; 95(11): 1054-1063, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30339643

RESUMEN

SIGNIFICANCE: Apple devices could be suitable for vision tests, provided that the test has been correctly adapted to the device, after considering the spatial and colorimetric characterization of the screen. PURPOSE: The majority of vision applications has not been developed by vision or colorimetry experts and suffers from conceptual and design errors that may lead average users to an erroneous assessment of their visual capabilities. The reliability of vision tests depends on the accurate generation of the necessary visual stimuli in a particular device. Our aim was to ascertain whether a given color test, designed for a colorimetrically characterized device, might be used in another similar device. METHODS: We evaluated color reproduction errors in three iPad tablets of different models with Retina screens, using their individual color characterization models and the model derived for another device. RESULTS: Our results showed, even with this small sample, the high degree of error caused when disregarding the fact that the colorimetric design valid for a given device may not be correct when displayed in another. CONCLUSIONS: The distortion of the chromatic content may lead to subjects with vision defects to pass as normal or vice versa, compromising diagnosis reliability.


Asunto(s)
Pruebas de Percepción de Colores/métodos , Percepción de Color/fisiología , Defectos de la Visión Cromática/diagnóstico , Computadoras de Mano , Diagnóstico por Computador/instrumentación , Defectos de la Visión Cromática/fisiopatología , Diseño de Equipo , Humanos , Reproducibilidad de los Resultados
5.
Optom Vis Sci ; 89(2): 221-8, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22105333

RESUMEN

PURPOSE: To obtain an accurate algorithm for calculating the keratometric index that minimizes the errors in the calculation of corneal power assuming only a single corneal surface in the range of corneal curvatures of the normal population. METHODS: Corneal power was calculated by using the classical keratometric index and also by using the Gaussian equation. Differences between types of calculation of corneal power were determined and modeled by regression analysis. RESULTS: We proposed two options for the selection of the most appropriate keratometric index (n(k)) value for each specific case. First was the use of specific linear equations (depending on the ratio of the anterior to the posterior curvature, k ratio) according to the value of the central radius of curvature of the anterior corneal surface (r(1c)) in 0.1 mm steps and the theoretical eye model considered. The second was the use of a general simplified equation only requiring r(1c) (Gullstrand eye model, n(k) = -0.0064286r(1c) + 1.37688; Le Grand eye model, n(k) = -0.0063804r(1c) + 1.37806). CONCLUSIONS: The generalization of the keratometric index (n(k)) value is not an appropriate approximation for the estimation of the corneal power and it can lead to significant errors. We proposed a new algorithm depending on r(1c), with a maximal associated error in the calculation of the corneal power of 0.5 D and without requiring knowledge of the posterior corneal curvature.


Asunto(s)
Algoritmos , Córnea/fisiología , Modelos Teóricos , Refracción Ocular/fisiología , Topografía de la Córnea , Humanos , Valores de Referencia
7.
J Opt Soc Am A Opt Image Sci Vis ; 19(8): 1532-6, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12152693

RESUMEN

We present a novel technique for considerably decreasing the sidelobe height of the axial point-spread function of one-photon 4Pi-confocal microscopes. By means of a numerical example, in which the ratio between the excitation and the fluorescence wavelengths was set to epsilon = lambdaexc/lambdadet = 0.8, we show that simply inserting a pair of properly designed two-ring binary masks in the illumination set allows the height of the axial sidelobes to be reduced from 20% to 5% of the height of the central peak. This allows one to receive the full benefit of the strong narrowness of the central lobe provided by the 4Pi-confocal technique.