Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Eur J Clin Invest ; 54(5): e14166, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38269600

RESUMEN

BACKGROUND: Embolization of debris can complicate transcatheter aortic valve implantation (TAVI) causing stroke. Cerebral embolism protection (CEP) devices can divert or trap debris. PURPOSE: To evaluate the efficacy of CEP during TAVI vs the standard procedure. DATA SOURCES: PubMed, SCOPUS and DOAJ 1/01/2014-04/12/2023. STUDY SELECTION: Randomized and observational studies comparing CEP versus standard TAVI, according to PRISMA. PRIMARY OUTCOME: stroke. SECONDARY OUTCOMES: death, bleeding, vascular access complications, acute kidney injury and infarct area. DATA EXTRACTION: Two investigators independently assessed study quality and extracted data. DATA SYNTHESIS: Twenty-six articles were included (540.247 patients). The primary endpoint was significantly lower (RR = 0.800 95%CI:0.682-0.940; p = 0.007) with CEP. Similarly, death rates were significantly lower with CEP (RR = 0.610 95%CI:0.482-0.771; p < 0.001). No difference was found for bleeding (RR = 1.053 95%CI:0.793-1.398; p = 0.721), vascular complications (RR = 0.937 95%CI:0.820-1.070; p = 0.334) or AKI (RR = 0.982 95%CI:0.754-1.279; p = 0.891). CONCLUSIONS: Use of CEP during TAVI is associated with improved outcomes. Future studies will identify patients who benefit most from CEP.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estudios Observacionales como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
2.
Minerva Cardiol Angiol ; 72(1): 1-10, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37971710

RESUMEN

The leverage of digital facilities in medicine for disease diagnosis, monitoring, and medical history recording has become increasingly pivotal. However, the advancement of these technologies poses a significant challenge regarding data privacy, given the highly sensitive nature of medical information. In this context, the application of Blockchain technology, a digital system where information is stored in blocks and each block is linked to the one before, has the potential to enhance existing technologies through its exceptional security and transparency. This paradigm is of particular importance in cardiovascular medicine, where the prevalence of chronic conditions leads to the need for secure remote monitoring, secure data storage and secure medical history updating. Indeed, digital support for chronic cardiovascular pathologies is getting more and more crucial. This paper lays its rationale in three primary aims: 1) to scrutinize the existing literature for tangible applications of blockchain technology in the field of cardiology; 2) to report results from a survey aimed at gauging the reception of blockchain technology within the cardiovascular community, conducted on social media; 3) to conceptualize a web application tailored specifically to cardiovascular care based on blockchain technology. We believe that Blockchain technology may contribute to a breakthrough in healthcare digitalization, especially in the field of cardiology; in this context, we hope that the present work may be inspiring for physicians and healthcare stakeholders.


Asunto(s)
Cadena de Bloques , Medios de Comunicación Sociales , Humanos , Registros Médicos , Privacidad , Tecnología
3.
Catheter Cardiovasc Interv ; 102(6): 1048-1056, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37933728

RESUMEN

BACKGROUND: Percutaneous treatment for ostial left circumflex artery (LCx) lesions is known to be associated with suboptimal results. AIMS: The present study aims to assess the procedural and long-term clinical outcomes of percutaneous coronary intervention (PCI) for de novo ostial LCx lesions overall and according to the coronary revascularization strategy. METHODS: Consecutive patients undergoing PCI with second generation drug eluting stents or drug coated balloons for de novo ostial LCx lesions in three high-volume Italian centers between 2012 and 2021 were retrospectively evaluated. The primary endpoint was target-vessel revascularization (TVR) at 2 years. Secondary endpoints included major adverse cardiovascular and cerebrovascular events (MACCE), target lesion revascularization, myocardial infarction, stroke, all-cause death, and repeat revascularization. RESULTS: A total of 366 patients were included in the analysis with a median follow-up of 901 (IQR: 450-1728) days. 79.5% of the patients were male, 33.6% were diabetic, 49.7% had a previous PCI, and 23.1% a prior surgical revascularization. Very ostial LCx stenting was performed in 34.1%, crossover from left main to LCx in 17.3%, and a two-stent strategy in 48.6% of cases, respectively. In the overall population, the incidence of TVR at 2 years was 19.0% while MACCE rate was 25.7%. No major differences in clinical outcomes were found according to the stenting strategy. Use of intracoronary imaging was associated with fewer MACCE (HR: 0.47, 95% CI: 0.25-1.13, p = 0.01), while the diameter of the stent implanted in the ostial LCx was associated with less TVR (HR: 0.43, 95% CI: 0.25-0.75, p = 0.002). CONCLUSIONS: Percutaneous revascularization of the ostial LCx is associated with a high rate of TVR, regardless of the stenting strategy. Intracoronary imaging and proper stent sizing may reduce the failure rates.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Angiografía Coronaria/métodos
4.
J Interv Cardiol ; 2023: 7958808, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37560012

RESUMEN

Background: In the setting of coronary artery dissection, both spontaneous and iatrogenic, fixing the intimal tear, usually with stent implantation, can be extremely challenging if the distal wire position has been lost. Common complications are mainly related to the inadvertent subintimal tracking of the guidewire while attempting to gain the distal true lumen. Aims: To report the registry results of using the SUOH 0.3 guidewire for managing coronary artery dissection in a real-world multicenter setting. Methods: The study population in this retrospective, multicenter, international registry included 75 consecutive patients who underwent PCI and required an antegrade wiring of a dissected coronary artery. Results: Successful use of SUOH 0.3 was achieved in 69 (92%) patients. The use of a microcatheter was associated with a significantly higher rate of TIMI 3 flow at the end of the procedure (no microcatheter: n = 17, 81%; microcatheter: n = 52, 96.3%; p = 0.017). The first recanalization attempt was made with the SUOH 03 guidewire in 48 (64%) cases, and it was successful in 42 (87%). The overall PCI success rate was reported in 72 (96%) patients, with no significant differences among patients with different origins, mechanisms, and locations of dissection. Conclusions: In this setting, the SUOH 0.3 guidewire provides high procedural success without additional complex techniques.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento , Oclusión Coronaria/etiología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Estudios Retrospectivos , Angiografía Coronaria , Enfermedad Crónica , Sistema de Registros
5.
Int J Cardiol ; 379: 16-23, 2023 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-36863420

RESUMEN

BACKGROUND: Sex-specific characteristics in patients with aortic stenosis and small annuli undergoing transcatheter aortic valve implantation (TAVI) might affect clinical outcomes and hemodynamics. METHODS: TAVI-SMALL 2 international retrospective registry included 1378 patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area < 400 mm2) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Women (n = 1233) were compared with men (n = 145). One-to-one propensity score (PS) matching resulted in 99 pairs. Primary endpoint was incidence of all-cause mortality. Incidence of pre-discharge severe prosthesis-patient mismatch (PPM) and its association with all-cause mortality were investigated. Binary logistic and Cox regression were performed to adjust the treatment effect for PS quintiles. RESULTS: Incidence of all-cause mortality at a median follow-up of 377 days did not differ between sex in the overall (10.3 vs. 9.8%, p = 0.842) and PS-matched (8.5 vs. 10.9%, p = 0.586) populations. After PS matching, pre-discharge severe PPM was numerically higher in women vs. men (10.2 vs. 4.3%), even though no evidence of a difference was found (p = 0.275). Within the overall population, women with severe PPM suffered a higher incidence of all-cause mortality when compared to those with less than moderate PPM (log-rank p = 0.024) and less than severe PPM (p = 0.027). CONCLUSIONS: No difference in all-cause mortality at medium-term follow-up was observed between women and men with aortic stenosis and small annuli undergoing TAVI. Incidence of pre-discharge severe PPM was numerically higher in women than men, and it was associated with increased all-cause mortality in women.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Femenino , Válvula Aórtica/cirugía , Estudios Retrospectivos , Puntaje de Propensión , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo
7.
J Clin Med ; 11(23)2022 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-36498587

RESUMEN

Background: Simultaneous ulnar and radial artery compression (SURC) has emerged as a strategy to increase radial artery flow and mitigate radial artery occlusion (RAO) while achieving adequate hemostasis after transradial access (TRA), though its technical adoption has been limited worldwide. Methods: A systematic search of studies comparing SURC versus isolated radial artery compression after TRA for coronary angiography and/or intervention was performed. Data were pooled by meta-analysis using random-effects models. Odds ratios (OR) with relative 95% confidence intervals (CI) and standardized mean difference were used as measures of effect estimates. The primary endpoint was the occurrence of overall RAO. Results: A total of 6 studies and 6793 patients were included. SURC method as compared to isolated radial artery compression was associated with a lower risk of RAO both overall (OR 0.29; 95% CI, 0.13−0.61, p < 0.001; number needed to treat to benefit [NNTB] =38) and in-hospital (OR 0.28; 95% CI: 0.10 to 0.75; p = 0.01, NNTB = 36), with a reduced risk of unsuccessful patent hemostasis (OR: 0.13; 95% CI: 0.02 to 0.85; p = 0.03, NNT = 5) and upper extremity pain (OR: 0.48; 95% CI: 0.24 to 0.95; p = 0.04, NNTB = 124). No significant difference was observed in hemostasis time and in the risk of hematoma. Conclusion: Compared to isolated radial artery compression, SURC is associated with lower risk of RAO, unsuccessful patent hemostasis, and reported upper limb pain, without any trade-off in safety outcomes. With further development of dedicated dual compression devices, the proposed technique should be freed from usage constraints.

8.
Sci Rep ; 10(1): 17144, 2020 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-33051585

RESUMEN

Percutaneous mitral valve repair has been increasingly performed worldwide after approval. We sought to investigate predictors of clinical outcome in patients with mitral regurgitation undergoing percutaneous valve repair. The MITRA-UMG study, a single-centre registry, retrospectively collected consecutive patients with symptomatic moderate-to-severe or severe MR undergoing MitraClip therapy. The primary endpoint was the composite of cardiovascular death or rehospitalization for heart failure. Between March 2012 and July 2018, a total of 150 consecutive patients admitted to our institution were included. Procedural success was obtained in 95.3% of patients. The composite primary endpoint of cardiovascular death or rehospitalization for HF was met in 55 patients (37.9%) with cumulative incidences of 7.6%, 26.2%, at 30 days and 1-year, respectively. In the Cox multivariate model, NYHA functional class and left ventricular end-diastolic volume index (LVEDVi), independently increased the risk of the primary endpoint at long-term follow-up. At Kaplan-Meier analysis, a LVEDVi > 92 ml/m2 was associated with an increased incidence of the primary endpoint. In this study, patients presenting with dilated ventricles (LVEDVi > 92 ml/m2) and advanced heart failure symptoms (NYHA IV) at baseline carried the worst prognosis after percutaneous mitral valve repair.


Asunto(s)
Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Anciano , Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Ecocardiografía/métodos , Femenino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hospitalización , Humanos , Estimación de Kaplan-Meier , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
9.
J Clin Med ; 9(9)2020 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-32932743

RESUMEN

Up to 15% of coronavirus disease 2019 (COVID-19) patients experience severe clinical presentation, resulting in acute respiratory distress (ARDS) and finally death. N-terminal natriuretic peptide (NT-proBNP) is associated with a worse prognosis in patients with ARDS. However, whether or not this peptide can help discriminate high-risk COVID-19 patients remains unclear. Therefore, in this meta-analysis, we summarized the available evidence on NT-proBNP in patients admitted for COVID-19. Pooled mean, mean differences (MD) and standardized mean difference (SMD) were the summary metrics. Thirteen studies were finally selected for this analysis with a total of 2248 patients, of which 507 had a severe condition (n = 240) or died (n = 267). Pooled mean NT-proBNP levels on admission were 790.57 pg/mL (95% confidence intervals (CIs): 532.50 to 1048.64) in patients that experienced a severe clinical condition or died, and 160.56 pg/mL (95% CI: 118.15 to 202.96) in non-severe patients (SMD: 1.05; 95% (CI): 0.83 to 1.28; p < 0.001; I2 74%; and MD was 645.84 pg/mL (95% CI: 389.50-902.18). Results were consistent in studies categorizing patients as non-survivors versus survivors (SMD: 1.17; 95% CI 0.95 to 1.40; p < 0. 001; I2: 51%), and in those classifying populations in severe versus non-severe clinical condition (SMD: 0.94 95% CI 0.56 to 1.32; p < 0.001; I2: 81%; pinteraction = 0.30). In conclusion, our results suggest that assessing NT-proBNP may support physicians in discriminating high-risk COVID-19 patients.

10.
Clin Hemorheol Microcirc ; 72(3): 239-245, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30909194

RESUMEN

BACKGROUND: The relationship between blood viscosity (BV) and endothelial function is rather complex. An increase in BV causes an increase in blood flow resistance, with negative hemodynamic effects; on the other hand, a moderate increase in BV causes an increase in wall stress shear (WSS), and consequent beneficial effects. As a matter of fact, the effect of changes in BV on endothelial function is not yet clear. OBJECTIVES: Aim of the present study was to evaluate in-vivo the effects of the acute reduction in BV on endothelial function, in healthy male subjects. METHODS: Fourteen healthy male blood donors were studied before and 48 hours after blood donation. Blood and plasma viscosity were measured at 37C° with a cone-plate viscometer. Endothelial function was evaluated through flow mediated vasodilation (FMD). RESULTS: Blood viscosity was reduced after blood donation (BV225 (cP) 4.53±0.59 vs.4.18±0.31, p < 0.05). FMD 50 s after cuff deflation was unchanged: 6.23±3.84 vs. 6.62±4.81, p = NS. The vasodilation, however, lasted longer and the area under the curve of FMD was significantly increased: 8.74±8.77 vs.16.14±8.65, p < 0.005. CONCLUSIONS: The present results demonstrate that the acute reduction of BV prolongs vasodilation, without affecting the amount of vasodilatation, possibly as adaptive reaction allowing more time for oxygen release.


Asunto(s)
Viscosidad Sanguínea/fisiología , Endotelio Vascular/fisiopatología , Adulto , Humanos , Masculino , Persona de Mediana Edad
11.
Clin Hemorheol Microcirc ; 68(1): 45-50, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29036798

RESUMEN

BACKGROUND: Blood viscosity (BV) might influence glucose delivery to peripheral tissues and play an important role in insulin resistance and diabetes mellitus. However, the exact relationship between BV and insulin resistance is not yet clear. OBJECTIVES: Aim of the present study is to evaluate the effects of the acute reduction in BV on insulin resistance, in healthy male subjects. METHODS: Fifteen healthy male blood donors have been studied before and 48 hours after blood donation. Blood and plasma viscosity have been measured at 37°C with a cone-plate viscometer. Insulin resistance has been evaluated by euglycemic/hyperinsulinemic clamp in eight subjects, and by iHOMA2 Index in further seven subjects. RESULTS: Blood viscosity was markedly reduced after blood donation (BV225 (cP) 4.53 ± 0.59 vs. 4.18 ± 0.31, p < 0.05). Insulin resistance was unchanged: MFFM clamp: 5.6 ± 4.5vs. 4.4 ± 2.2 and iHOMA2 Index 1.2 ± 0.6 vs. 1.2 ± 0.5, before vs. after respectively, p = NS. Blood pressure and lipids were unchanged after blood donation. CONCLUSIONS: The present results demonstrate that acute reduction of BV in healthy male subjects does not change the insulin resistance, measured using both euglycemic/hyperinsulinemic clamp and iHOMA2 Index. Further intervention studies are needed to assess the effect that the reduction in BV can have in subjects with insulin resistance.


Asunto(s)
Viscosidad Sanguínea/inmunología , Resistencia a la Insulina/fisiología , Adulto , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...