Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Bone Jt Open ; 5(6): 457-463, 2024 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-38823797

RESUMEN

Aims: Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail. Methods: A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value. Results: A total of 98 of the 112 patients met the inclusion criteria. Overall, 65 patients were female (66.3%), the mean age was 83.23 years (SD 7.07), and the mean follow-up was 378 days (SD 36). Cut-out was observed in five patients (5.10%). The variables identified by univariate analysis with p < 0.05 were included in the multivariate logistic regression model were screw placement and TAD. The TAD was significant with an odds ratio (OR) 5.03 (p = 0.012) as the screw placement with an OR 4.35 (p = 0.043) in the anteroposterior view, and OR 10.61 (p = 0.037) in the lateral view. The TAD threshold value identified was 29.50 mm. Conclusion: Our study confirmed the risk factors for cut-out in the double-screw nail are comparable to those in the single screw. We found a TAD value of 29.50 mm to be associated with a risk of cut-out in double-screw nails, when good fracture reduction is granted. This value is higher than the one reported with single-screw nails. Therefore, we suggest the role of TAD should be reconsidered in well-reduced fractures treated with double-screw intramedullary nail.

2.
Med Glas (Zenica) ; 21(1): 208-213, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38341752

RESUMEN

Aim Significant risk factors for femoral nail cutout are well-documented, primarily in the context of single-screw proximal nails. However, it remains uncertain whether those same risk factors are applicable when considering different implant devices. The aim of this retrospective cohort study was to compare cutout risk factors between single- versus double-screw proximal femoral nails. Methods Patients over the age of 75 with intertrochanteric femur fractures (AO Classification 31-A1 or 31-A2) were included in the multicentre study. A study group was treated with a double-screw nail, while a control group received single-screw device. Demographic data, surgical time (min), fracture pattern, distal locking, reduction quality, comorbidities, tip-apex distance (TAD) and 12-month functional scores was collected. Results Two hundred patients were enrolled, 100 for each group. Nine patients experienced a cutout complication, five in the study and four in the control group. The main differences were in distal locking configurations (p<0.05) and in TAD values (p<0.05). The TAD value was higher in the study than in the control group (30.40±0.89 versus 26.79±1.79). No differences at 12-month follow up were reported according to functional scores. Conclusion This study provides insights into the choice of nail systems for intertrochanteric femur fractures, highlighting the importance of distal locking configurations and TAD values. The double screw nail exhibits quite a tolerance by having a higher average TAD value. These findings may guide clinical decisionmaking in the treatment of this challenging fracture type.

3.
Injury ; 54 Suppl 1: S46-S52, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33234266

RESUMEN

Fracture healing is a complex physiologic process, relying on the crucial interplay between biological and mechanical factors. It is generally assessed using imaging modalities, including conventional radiology, CT, MRI and ultrasound (US), based on the fracture and patient features. Although these techniques are routinely used in orthopaedic clinical practice, unfortunately, they do not provide any information about the biomechanical status of the fracture site. Therefore, in recent years, several non-invasive techniques have been proposed to assess bone healing using ultrasonic wave propagation, changes in electrical properties of bones and callus stiffness measurement. Moreover, different research groups are currently developing smart orthopaedic implants (plates, intramedullary nails and external fixators), able to provide information about the fracture healing process. These devices could significantly improve orthopaedic and trauma clinical practice in the future and, at the same time, reduce patients' exposure to X-rays. This study aims to define the role of traditional imaging techniques and emerging technologies in the assessment of the fracture healing process.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas Óseas , Ortopedia , Humanos , Curación de Fractura , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Fijadores Externos
4.
Med Glas (Zenica) ; 20(1)2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36574271

RESUMEN

Aim To demonstrate a reduction of risk factors ray-depending in proximal femur nailing of intertrochanteric femur fractures, comparing standard technique with computer-assisted navigation system. Methods One hundred patients hospitalised between October 2021 and June 2022 with intertrochanteric femur fractures type 31-A1 and 31-A2 were prospectively enrolled and divided randomly into two groups. A study group was treated with computer-assisted navigation system ATLAS (Masmec Biomed, Modugno, Bari, Italy) (20 patients), while a control group received the standard nailing technique. The same intertrochanteric nail was implanted by a single senior surgeon, Endovis BA 2 (EBA2, Citieffe, Calderara di Reno, Bologna, Italy). The following data were recorded: the setup time of operating room (STOR; minutes); surgical time (ST; minutes); radiation exposure time (ETIR; seconds) and dose area product (DAP; cGy·cm2). Results Patients underwent femur nailing with computer-assisted navigation system reported more set-up time of operating room (24.87±4.58; p<0.01), less surgical time (26.15±5.80; p<0.01), less time of radiant exposure (4.84±2.07; p<0.01) and lower dose area product (16.26±2.91; p<0.01). Conclusion The preliminary study demonstrated that computerassisted navigation allowed a better surgical technique standardization, significantly reduced exposure to ionizing radiation, including a reduction in surgical time. The ATLAS system could also play a key role in residents improving learning curve.

5.
Medicina (Kaunas) ; 58(11)2022 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-36363493

RESUMEN

Background and Objectives: To assess the effect of continuous cold flow (CCF) therapy on pain reduction, opioid consumption, fast recovery, less perioperative bleeding and patient satisfaction in patients undergoing a total knee arthroplasty. Materials and Methods: Patients affected by knee osteoarthritis between September 2020 and February 2022 were enrolled in this case-control study. Patients were randomly divided into two groups (n = 50, each): the study group received postoperative CCF therapy while the control group was treated by cold pack (gel ice). The CCF device is a computer-assisted therapy with continuous cold fluid, allowing a selective distribution, constant and uniform, of cold or hot on the areas to be treated. In both groups, pre- and postoperative evaluations at 6, 24, 72 h and at the fifth day were conducted using Visual Analogic Scale (VAS), opioid consumption, passive range of motion, preoperative hematocrit, total blood loss by Gross formula, transfusion requirement and patient satisfaction questionnaire. Results: One hundred patients, 52 women (52%), were included in the study. Reduction of pain, opioid consumption and increase in passive range of movement were statistically significantly demonstrated in the study group on the first and third days. Patients were satisfied with adequate postoperative pain management due to CCF therapy (p = 0.01) and they would recommend this treatment to others (p = 0.01). Conclusions: A continuous cold flow device in the acute postoperative setting after total knee arthroplasty is associated with pain reduction and improving early movement. Patients were almost satisfied with the procedure. The management of perioperative pain control could improve participation in the early rehabilitation program as demonstrated by the increase in ROM, psychological satisfaction and reduction in opioid use.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Femenino , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/rehabilitación , Analgésicos Opioides/uso terapéutico , Dolor Postoperatorio/tratamiento farmacológico , Rango del Movimiento Articular , Estudios de Casos y Controles , Resultado del Tratamiento
6.
Strategies Trauma Limb Reconstr ; 17(2): 68-73, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35990180

RESUMEN

Introduction: Injuries around the elbow pose a challenging problem for orthopaedic surgeons. The complex bony architecture of the joint should be restored and the thin soft tissue envelope needs to be handled with meticulous care. Elbow instability is a complication seen after dislocations and fractures of the elbow and remains a treatment challenge. The purpose of this study was to provide subjective and objective results following the surgical treatment of unstable elbow dislocations with an external hinged fixation technique. Methods: Forty-six consecutive patients with complex trauma of the elbow with instability after ligament reconstruction were enrolled between January 2017 and December 2019. The parameters used to quantify the subjective and objective functional results were the Mayo Elbow Score (MES, objective) and Oxford Elbow Score (OES, subjective), and clinical stability of the elbow joint. We also performed a radiological follow-up of the fractures. Results: The mean MES and OES scores were good at the 12-month follow-up. We had 38 patients with stable joints and 8 patients with minor instability. Using the stress test, we saw a significant difference in the affected joint under varus stress (6.7 ± 1.8 mm) compared to the healthy joint (5.8 ± 1.2 mm) laterally. Furthermore, medially the gap was significantly larger (5.8 ± 0.8 mm, treated elbow) than the contralateral gap under valgus stress (4.3 ± 0.8 mm) (p <0.001). Twenty-one complications occurred in 46 patients (46%): Seven patients had a clinical change of elbow axis: Three valgus (6%), four varus (9%); Superficial wound infection occurred in one case (2%) and ulnar nerve dysfunction in two (4%). The most common medium-term complication was post-traumatic osteoarthritis in eight cases (17%). Heterotopic ossification occurred in five patients (11%) and elbow stiffness in five cases (11%). Conclusion: The use of the hinged elbow external fixator in the treatment of complex elbow trauma is a valid therapeutic adjunct to ligamentous reconstruction showing encouraging results with acceptable complications. How to cite this article: Meccariello L, Caiaffa V, Mader K, et al. Treatment of Unstable Elbow Injuries with a Hinged Elbow Fixator: Subjective and Objective Results. Strategies Trauma Limb Reconstr 2022;17(2):68-73.

7.
OTA Int ; 5(3 Suppl): e198, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35949498

RESUMEN

Fragility fractures represent a growing global problem, including in the United Kingdom and European countries. Reports demonstrate the benefits of national guidance and organized fragility fracture programs through fracture liaison services to deliver care to patients who sustain these injuries. The challenge of assembling multidisciplinary teams, providing routine screening of appropriate patients, and monitoring therapies where there is a known compliance problem, remains an obstacle to the success of fragility fracture treatment programs to all. Efforts should continue to introduce and maintain fracture liaison services through coordinated national approaches and advanced systems.

8.
Med Glas (Zenica) ; 18(1): 260-266, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33655742

RESUMEN

Aim To investigate the role of cordonal blood platelet-rich plasma (PRP) intra-articular injections for treating the patients with knee osteoarthritis in terms of procedure safety and clinical outcomes. Methods Twenty-five patients affected by knee osteoarthritis were enrolled and received one single intra-articular knee injection of umbilical cord PRP in a volume of 10 mL. A follow-up was investigated at time 0, 4, 8, 12 weeks and 6 months, evaluating clinical parameters and functional performances. Results No serious adverse events were identified. The paired ttest analysis showed a significant difference between baseline and each follow-up times for all clinical scales (p<0.05), with a significant improvement of clinical outcomes. Conclusion Allogeneic PRP can generate reliable therapeutic effect. The high content of tissue regenerative factors in cord blood platelets makes cordonal blood one of the ideal sources of PRP.


Asunto(s)
Osteoartritis de la Rodilla , Sangre Fetal , Humanos , Ácido Hialurónico , Inyecciones Intraarticulares , Osteoartritis de la Rodilla/terapia , Resultado del Tratamiento
9.
Int Orthop ; 44(8): 1453-1459, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32591960

RESUMEN

BACKGROUND: From February 21, the day of hospitalisation in ICU of the first diagnosed case of Covid-19, the social situation and the hospitals' organisation throughout Italy dramatically changed. METHODS: The CIO (Club Italiano dell'Osteosintesi) is an Italian society devoted to the study of traumatology that counts members spread in public and private hospitals throughout the country. Fifteen members of the CIO, Chairmen of 15 Orthopaedic and Trauma Units of level 1 or 2 trauma centres in Italy, have been involved in the study. They were asked to record data about surgical, outpatients clinics and ER activity from the 23rd of February to the 4th of April 2020. The data collected were compared with the data of the same timeframe of the previous year (2019). RESULTS: Comparing with last year, overall outpatient activity reduced up to 75%, overall Emergency Room (ER) trauma consultations up to 71%, elective surgical activity reduced up to 100% within two weeks and trauma surgery excluding femoral neck fractures up to 50%. The surgical treatment of femoral neck fractures showed a stable reduction from 15 to 20% without a significant variation during the timeframe. CONCLUSIONS: Covid-19 outbreak showed a tremendous impact on all orthopaedic trauma activities throughout the country except for the surgical treatment of femoral neck fractures, which, although reduced, did not change in percentage within the analysed timeframe.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus , Procedimientos Ortopédicos/estadística & datos numéricos , Pandemias , Neumonía Viral , COVID-19 , Infecciones por Coronavirus/epidemiología , Brotes de Enfermedades , Procedimientos Quirúrgicos Electivos/estadística & datos numéricos , Servicio de Urgencia en Hospital , Humanos , Italia/epidemiología , Ortopedia , Neumonía Viral/epidemiología , SARS-CoV-2 , Centros Traumatológicos , Traumatología
10.
Int Orthop ; 43(1): 193-200, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30488127

RESUMEN

INTRODUCTION: Femoral shaft fractures with third fragments have a high non-union rate, which may reach 14%. This study aims to assess the impact of the radiological features of the third fragment, evaluated on post-operative X-rays, on the outcome of femoral shaft fractures type 32-B managed with intramedullary nailing, in order to obtain an algorithm which could predict the fracture healing time. MATERIALS AND METHODS: We have retrospectively evaluated a series of 52 patients. On post-operative X-rays, four radiological parameters were evaluated: the third fragment angle, the fracture gap, the third fragment size, and the mean third fragment displacement. All the patients underwent a radiologic follow-up at one, two, three, six, nine and 12 months post-operatively, to assess the bone healing. The patients were then divided into three groups, according to the fracture healing time: within six months (group A), between six and 12 months (group B), or fracture non-union after 12 months (group C). RESULTS: In 28 patients, out of 52 (53.85%), the fracture healing was observed at 6-month follow-up; in 18 patients, out of 52 (34.62%), the fracture healed within 12 months after trauma; and in six patients, out of 52 (11.54%), no fracture healing was observed at 12-month follow-up. The mean third fragment size was significantly different in each group (p < 0.05), while the mean third fragment displacement was significantly higher in group C, compared with group A (p = 0.0006) and group B (p = 0.0027). In group B, a positive correlation was found between the fracture healing time and the mean third fragment size (R = 0.594, p = 0.036); in group C, the fracture union time was positively related to the third fragment size (R = 0.689, p = 0.013) and the mean third fragment displacement (R = 0.7107, p = 0.006). Regression analysis showed that the third fragment size and the mean third fragment displacement are the most important features which affect the fracture healing time. CONCLUSIONS: The third fragment size (cutoff 40 mm) is the leading parameter to influence the fracture healing within or in more than six months. The mean third fragment displacement (cutoff 12 mm); on the other hand, impacts on the fracture delayed rather than absent healing.


Asunto(s)
Fracturas del Fémur/diagnóstico por imagen , Fémur/diagnóstico por imagen , Fijación Intramedular de Fracturas , Curación de Fractura , Fracturas no Consolidadas/diagnóstico por imagen , Adulto , Anciano , Algoritmos , Clavos Ortopédicos , Diáfisis/diagnóstico por imagen , Diáfisis/fisiopatología , Diáfisis/cirugía , Femenino , Fracturas del Fémur/fisiopatología , Fracturas del Fémur/cirugía , Fémur/fisiopatología , Fémur/cirugía , Fracturas no Consolidadas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo , Resultado del Tratamiento , Adulto Joven
12.
Injury ; 47 Suppl 4: S131-S137, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27484831

RESUMEN

OBJECTIVES: To determine the efficacy of hybrid external fixation in the treatment of tibial pilon fractures. DESIGN: Retrospective, multicentre study. PATIENTS/PARTICIPANTS: Adult patients with tibial pilon fractures treated with hybrid external fixation. INTERVENTION: Fracture reduction with ligamentotaxis and fixation with XCaliber hybrid external fixator. MAIN OUTCOME MEASUREMENTS: Fracture union, complications, functional outcome (Mazur Ankle Score). RESULTS: Union was obtained in 159 fractures at an average of 125days; there were three delayed unions and three non-unions. The most frequent complication was superficial pin-track infections (48), all of which responded to local wound care and antibiotics. There were no deep infections and no DVT. Only one fracture had loss of reduction that required frame revision. The overall functional scores were 91 (excellent) for AO/OTA type A fractures, 89 (good) for type B fractures, and 75 (satisfactory) for type C fractures. CONCLUSIONS: Hybrid external fixation is an effective method of stabilising tibial pilon fractures, particularly those with marked comminution. The minimally-invasive technique and stable fixation enable early mobilisation, with good functional results and minimal complications. LEVEL OF EVIDENCE: Level IV Case series.


Asunto(s)
Traumatismos del Tobillo/cirugía , Articulación del Tobillo/cirugía , Fijadores Externos , Fluoroscopía , Fijación de Fractura , Infección de la Herida Quirúrgica/prevención & control , Fracturas de la Tibia/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Traumatismos del Tobillo/diagnóstico por imagen , Traumatismos del Tobillo/fisiopatología , Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/fisiopatología , Femenino , Estudios de Seguimiento , Fijación de Fractura/instrumentación , Fijación de Fractura/métodos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Posición Supina , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/fisiopatología , Resultado del Tratamiento , Adulto Joven
13.
J Pediatr Hematol Oncol ; 35(6): e260-4, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23652868

RESUMEN

BACKGROUND: Osteoporosis is a leading cause of morbidity in patients affected by ß-thalassemia major or intermediate; we aimed to assess the association between demineralization observed in young thalassemic patients. METHODS: A total of 88 patients with ß-thalassemia were recruited at Microcitemia Center of Taranto Hospital under the Prevention Osteoporosis and Fractures research project from 2008 to 2010. All the patients were screened with both dual energy x-ray absorptiometry (DXA) and quantitative ultrasound (QUS). T score and Z score values were obtained for each subject. RESULTS: The overall prevalence of demineralization was 84% with DXA and 70% with QUS, whereas normality was found in 16% of patients screened with DXA and in 30% of cases with QUS. Hypogonadism, hypothyroidism, diabetes mellitus, hepatitis-B, and the presence of previous fragility fractures were significantly associated with the demineralization status (lower T scores values) both with DXA and QUS. CONCLUSION: Our data confirm that DXA and QUS examinations are both useful for detecting bone demineralization in thalassemic patients.


Asunto(s)
Fracturas Óseas/diagnóstico por imagen , Osteoporosis/diagnóstico por imagen , Talasemia beta/complicaciones , Absorciometría de Fotón , Adulto , Anciano , Diabetes Mellitus , Femenino , Falanges de los Dedos de la Mano/diagnóstico por imagen , Fracturas Óseas/etiología , Hepatitis B/complicaciones , Humanos , Hipogonadismo/complicaciones , Hipotiroidismo/complicaciones , Italia , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Osteoporosis/epidemiología , Osteoporosis/etiología , Prevalencia , Ultrasonografía , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...