Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Clin Oral Investig ; 21(3): 779-785, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27114091

RESUMEN

OBJECTIVES: The purpose of this study was to investigate postoperative analgesic effect of ropivacaine administered as main or supplemental injection for the inferior alveolar nerve block (IANB) in patients undergoing lower third molar surgery. MATERIALS AND METHODS: The double-blind randomized study comprised 72 healthy patients. All patients received two blocks, the IANB for surgical procedure + IANB after surgery for postoperative pain control, and were divided into three groups: (1) 2 % lidocaine/epinephrine + 1 % ropivacaine, (2) 2 % lidocaine/epinephrine + saline, and (3) 1 % ropivacaine + saline. The occurrence of postoperative pain, pain intensity and analgesic requirements were recorded. Data were statistically analyzed using chi-square, Fisher, and Kruskal-Wallis tests and analysis of variance (ANOVA) with Bonferroni and Tukey correction. RESULTS: Ropivacaine was more successful than lidocaine/epinephrine in obtaining duration of postoperative analgesia, reduction of pain, and analgesic requirements whether ropivacaine was used for surgical block or administered as a supplemental injection after surgery. CONCLUSIONS: Ropivacaine (1 %, 2 ml) resulted in effective postoperative analgesia after lower third molar surgery. CLINICAL RELEVANCE: Since pain control related to third molar surgery requires the effective surgical anesthesia and postoperative analgesia, the use of 1 % ropivacaine could be clinically relevant in a selection of appropriate pain control regimen for both surgical procedure and early postsurgical treatment.


Asunto(s)
Amidas/uso terapéutico , Anestésicos Locales/uso terapéutico , Tercer Molar/cirugía , Manejo del Dolor/métodos , Dolor Postoperatorio/tratamiento farmacológico , Adolescente , Adulto , Método Doble Ciego , Epinefrina/uso terapéutico , Femenino , Humanos , Lidocaína/uso terapéutico , Masculino , Mandíbula , Bloqueo Nervioso/métodos , Dimensión del Dolor , Ropivacaína , Resultado del Tratamiento
2.
Vojnosanit Pregl ; 73(12): 1132-8, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29341570

RESUMEN

Background/Aim: The mechanism of impaired bone healing in diabetes mellitus includes different tissue and cellular level activities due to micro- and macrovascular changes. As a chronic metabolic disease with vascular complications, diabetes affects a process of bone regeneration as well. The therapeutic approach in bone regeneration is based on the use of osteoinductive autogenous grafts as well as osteoconductive synthetic material, like a ß-tricalcium phosphate. The aim of the study was to determine the quality and quantity of new bone formation after the use of autogenous bone and ß-tricalcium phosphate in the model of calvarial critical-sized defect in rabbits with induced diabetes mellitus type I. Methods: The study included eight 4-month-old Chincilla rabbits with alloxan-induced diabetes mellitus type I. In all animals, there were surgically created two calvarial bilateral defects (diameter 12 mm), which were grafted with autogenous bone and ß-tricalcium phosphate (n = 4) or served as unfilled controls (n = 4). After 4 weeks of healing, animals were sacrificed and calvarial bone blocks were taken for histologic and histomorphometric analysis. Beside descriptive histologic evaluation, the percentage of new bone formation, connective tissue and residual graft were calculated. All parameters were statistically evaluated by Friedman Test and post hock Wilcoxon Singed Ranks Test with a significance of p < 0.05. Results: Histology revealed active new bone formation peripherally with centrally located connective tissue, newly formed woven bone and well incorporated residual grafts in all treated defects. Control samples showed no bone bridging of defects. There was a significantly more new bone in autogeonous graft (53%) compared with ß-tricalcium phosphate (30%), (p < 0.030) and control (7%), (p < 0.000) groups. A significant difference was also recorded between ß-tricalcium phosphate and control groups (p < 0.008). Conclusion: In the present study on the rabbit grafting model with induced diabetes mellitus type I, the effective bone regeneration of critical bone defects was obtained using autogenous bone graft. [Projekat Ministarstva nauke Republike Srbije, br. 175021].


Asunto(s)
Regeneración Ósea/efectos de los fármacos , Trasplante Óseo/métodos , Fosfatos de Calcio/farmacología , Diabetes Mellitus Experimental/fisiopatología , Diabetes Mellitus Tipo 1/fisiopatología , Oseointegración/efectos de los fármacos , Cráneo/efectos de los fármacos , Cráneo/cirugía , Aloxano , Animales , Diabetes Mellitus Experimental/inducido químicamente , Diabetes Mellitus Experimental/patología , Diabetes Mellitus Tipo 1/inducido químicamente , Diabetes Mellitus Tipo 1/patología , Conejos , Cráneo/patología , Cráneo/fisiopatología , Factores de Tiempo , Trasplante Autólogo
3.
Vojnosanit Pregl ; 73(12): 1173-7, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-29341577

RESUMEN

Introduction: The material used for root-end filling has to be biocompatible with adjacent periapical tissue and to stimulate its regenerative processes. Tricalcium silicate cement (TSC), as a new dental material, shows good sealing properties with dentin, high compression strengths and better marginal adaptation than commonly used root-end filling materials. Although optimal postoperative healing of periapical tissues is mainly influenced by characteristics of end-root material used, it could sometimes be affected by the influence of systemic diseases, such as diabetes mellitus (DM). Case report: We presented apical healing of the upper central incisor, retrofilled with TSC, in a diabetic patient (type 2 DM) with peripheral neuropathy. Standard root-end resection of upper central incisor was accompanied by retropreparation using ultrasonic retrotips to the depth of 3 mm and retrofilling with TSC. Post-operatively, the surgical wound healed uneventfully. However, the patient reported undefined dull pain in the operated area that could possibly be attributed to undiagnosed intraoral diabetic peripheral neuropathy, what was evaluated clinically. Conclusion: Although TSC presents a suitable material for apical root-end filling in the treatment of chronic periradicular lesions a possible presence of systemic diseases, like type 2 DM, has to be considered in the treatment outcome estimation.


Asunto(s)
Compuestos de Calcio/uso terapéutico , Diabetes Mellitus Tipo 2/complicaciones , Neuropatías Diabéticas/etiología , Enfermedades Periapicales/cirugía , Materiales de Obturación del Conducto Radicular/uso terapéutico , Obturación del Conducto Radicular , Silicatos/uso terapéutico , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/fisiopatología , Neuropatías Diabéticas/diagnóstico , Neuropatías Diabéticas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Percepción del Dolor , Umbral del Dolor , Dolor Postoperatorio/complicaciones , Dolor Postoperatorio/fisiopatología , Enfermedades Periapicales/complicaciones , Enfermedades Periapicales/diagnóstico por imagen , Radiografía Dental , Obturación del Conducto Radicular/efectos adversos , Resultado del Tratamiento
4.
Clin Implant Dent Relat Res ; 15(3): 341-9, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22171668

RESUMEN

PURPOSE: The aim of this study was to investigate the relationship between surgical techniques and implant macro-design (self-tapping/non-self-tapping) for the optimization of implant stability in the low-density bone present in the posterior maxilla using resonance frequency analysis (RFA). MATERIALS AND METHODS: A total of 102 implants were studied. Fifty-six self-tapping BlueSkyBredent® (Bredent GmbH&Co.Kg®, Senden, Germany) and 56 non-self-tapping Standard Plus Straumann® (Institut Straumann AG®, Waldenburg, Switzerland) were placed in the posterior segment of the maxilla. Implants of both types were placed in sites prepared with either lateral bone-condensing or with bone-drilling techniques. Implant stability measurements were performed using RFA immediately after implant placement and weekly during a 12-week follow-up period. RESULTS: Both types of implants placed after bone condensing achieved significantly higher stability immediately after surgery, as well as during the entire 12-week observation period compared with those placed following bone drilling. After bone condensation, there were no significant differences in primary stability or in implant stability after the first week between both implant types. From 2 to 12 postoperative weeks, significantly higher stability was shown by self-tapping implants. After bone drilling, self-tapping implants achieved significantly higher stability than non-self-tapping implants during the entire follow-up period. CONCLUSIONS: The outcomes of the present study indicate that bone drilling is not an effective technique for improving implant stability and, following this technique, the use of self-tapping implants is highly recommended. Implant stability optimization in the soft bone can be achieved by lateral bone-condensing technique, regardless of implant macro-design.


Asunto(s)
Implantes Dentales , Diseño de Prótesis Dental , Retención de Prótesis Dentales , Adulto , Densidad Ósea/fisiología , Tomografía Computarizada de Haz Cónico/métodos , Implantación Dental Endoósea/instrumentación , Implantación Dental Endoósea/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Maxilar/cirugía , Osteotomía/instrumentación , Osteotomía/métodos , Planificación de Atención al Paciente , Vibración
5.
Artículo en Inglés | MEDLINE | ID: mdl-21330161

RESUMEN

OBJECTIVE: The aim of this clinical trial was to compare primary and secondary stability of implants placed by bone condensing versus the standard drilling technique in the posterior edentulous maxilla. STUDY DESIGN: Forty-eight SLA Straumann implants 4.1 × 10 mm (Institut Straumann AG, Waldenburg, Switzerland) were placed into edentulous maxillary posterior region in the same positions bilaterally, using the bone condensation technique for one and the standard technique for the other side. Implant stability measurements were performed immediately after implant placement, as well as every week for the next 6 weeks by use of resonance frequency analysis (RFA). Data were analyzed using Mann-Whitney U and Wilcoxon tests. RESULTS: After bone condensing, significantly higher implant stability was recorded immediately after surgery as well as during the whole observation period of 6 weeks compared with bone-drilling technique (Mann-Whitney U test, P = .000). CONCLUSIONS: The bone-condensing technique can be recommended as an alternate surgical approach for implant site preparation in reduced bone density to achieve greater implant stability in the posterior maxilla.


Asunto(s)
Densidad Ósea , Implantación Dental Endoósea/instrumentación , Arcada Edéntula/cirugía , Maxilar/cirugía , Procedimientos Quirúrgicos Preprotésicos Orales/instrumentación , Proceso Alveolar/diagnóstico por imagen , Proceso Alveolar/cirugía , Implantación Dental Endoósea/métodos , Retención de Prótesis Dentales , Fracaso de la Restauración Dental , Femenino , Estudios de Seguimiento , Humanos , Arcada Edéntula/diagnóstico por imagen , Masculino , Maxilar/diagnóstico por imagen , Procedimientos Quirúrgicos Preprotésicos Orales/métodos , Oseointegración , Radiografía , Estadísticas no Paramétricas , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA