Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Heart Rhythm ; 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38493989

RESUMEN

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

2.
Heart Rhythm ; 20(2): 233-240, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-37283031

RESUMEN

BACKGROUND: Elevated resting heart rate is a risk factor for cardiovascular events. OBJECTIVE: The purpose of this study was to investigate the clinical significance of nocturnal heart rate (nHR) and 24-hour mean heart rate (24h-HR) obtained by continuous remote monitoring (RM) of implantable devices. METHODS: We analyzed daily-sampled trends of nHR, 24h-HR, and physical activity in patients on ß-blocker therapy for chronic heart failure and with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (CRT-Ds). Patients were grouped by average nHR and 24h-HR quartile during follow-up to estimate the respective incidence of nonarrhythmic death and device-treated ventricular tachycardia/fibrillation (VT/VF). RESULTS: The study cohort included 1330 patients (median age 69 years [interquartile range 61-77 years]; 41% [n = 550] with CRT-D; median follow-up 25 months [interquartile range 13-42 months]). Compared with patients in the lowest nHR quartile (≤57 beats/min) group, patients in the highest quartile group (>65 beats/min) had an increased risk of nonarrhythmic death (adjusted hazard ratio [AHR] 2.25; 95% confidence interval [CI] 1.13-4.50; P = .021) and VT/VF (AHR 1.98; 95% CI 1.40-2.79; P < .001) and were characterized by the lowest level of physical activity (P ≤ .0004 vs every other nHR quartiles). The highest 24h-HR quartile group (>75 beats/min) showed an increased risk of VT/VF (AHR 2.13; 95% CI 1.52-2.99; P < .001) and a weaker though significant association with nonarrhythmic mortality (AHR 1.80; 95% CI 1.00-3.22; P = .05) as compared with the lowest 24h-HR quartile group (≤65 beats/min). CONCLUSION: In remotely monitored patients with implantable cardioverter-defibrillator/CRT-D on ß-blocker therapy for heart failure, elevated heart rates (nHR >65 beats/min and 24h-HR >75 beats/min) were associated with increased mortality and VT/VF risk. nHR showed a stronger association than 24h-HR with worst prognosis and lowest physical activity.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Disfunción Ventricular Izquierda , Humanos , Persona de Mediana Edad , Anciano , Frecuencia Cardíaca , Pronóstico , Volumen Sistólico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Arritmias Cardíacas/terapia , Factores de Riesgo , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Disfunción Ventricular Izquierda/complicaciones
3.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36709469

RESUMEN

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Asunto(s)
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedancia Eléctrica , Estudios Retrospectivos , Fibrilación Ventricular , Desfibriladores Implantables
5.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36543505

RESUMEN

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Asunto(s)
Desfibriladores Implantables , Humanos , Masculino , Femenino , Anciano , Desfibriladores Implantables/efectos adversos , Puntaje de Propensión , Resultado del Tratamiento , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Cardioversión Eléctrica
6.
J Cardiovasc Dev Dis ; 9(4)2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35448070

RESUMEN

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and catheter ablation, which can be used in symptomatic patients refractory to antiarrhythmic therapy. Pulmonary vein isolation (PVI) remains the cornerstone of any ablation procedure. A major limitation of current catheter ablation procedures is important to recognize because even when the PVI is performed in highly experienced centers, PVI reconnection was documented in about 20% of patients. Therefore, better technology is needed to improve ablation lesions. One of the novelties in recent years is pulsed filed ablation (PFA), a non-thermal energy that uses trains of high-voltage, very-short-duration pulses to kill the cells. The mechanism of action of this energy consists of creating pores in the myocardiocyte cell membrane in a highly selective and tissue-specific way; this leads to death of the target cells reducing the risk of damage to surrounding non-cardiac tissues. In particular during the animal studies, PVI and atrial lines were performed effectively without PV stenosis. Using PFA directly on coronary arteries, there was no luminal narrowing, there has been no evidence of incidental phrenic nerve injury, and finally, PFA has been shown not to injure esophageal tissue when directly applied to the esophagus or indirectly through ablation in the left atrium. The aim of this review is to report all published animal and clinical studies regarding this new technology to treat paroxysmal and persistent AF.

8.
Int J Cardiol Heart Vasc ; 38: 100952, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35071727

RESUMEN

BACKGROUND: Defibrillation testing (DT) can be omitted in patients undergoing transvenous implantable cardioverter-defibrillator (T-ICD) implantation, but it is still recommended for patients at risk for a high defibrillation threshold and for ICD generator changes. Moreover, DT is still recommended on implantation of subcutaneous ICD (S-ICD). The aim of the present survey was to analyze the current practice of DT during T-ICD and S-ICD implantations. METHODS: In March 2021, an ad hoc questionnaire on the current performance of DT and the standard practice adopted during testing was completed at 72 Italian centers implanting S-ICD and T-ICD. RESULTS: 48 (67%) operators reported never performing DT during de-novo T-ICD implantations, while no operators perform it systematically. The remaining respondents perform it for patients at risk for a high defibrillation threshold. DT is never performed at T-ICD generator change. At the time of de-novo S-ICD implantation, DT is never performed by 9 (13%) operators and performed systematically by 48 (66%). The remaining operators frequently omit DT in patients with more severe systolic dysfunction. DT is not performed at S-ICD generator change by 92% of operators. DT is conducted by delivering a first shock energy of 65 J by 60% of operators, while the remaining 40% test lower energy values. CONCLUSIONS: In current clinical practice, most operators omit DT at T-ICD implantation, even when still recommended in the guidelines. DT is also frequently omitted at S-ICD implantation, and a wide variability exists among operators in the procedures followed during DT.

9.
J Interv Card Electrophysiol ; 64(3): 607-619, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34709504

RESUMEN

PURPOSE: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients. METHODS: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry. RESULTS: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables. Our cohort included 1,911 patients with left ventricular dysfunction (median age 71, 18.3% female) from sites not using any risk stratification score for systematic patient screening. Patients received an ICD (53.8%) or CRT-D (46.2%) between 2011 and 2017, after standard physician evaluation. There were 56 deaths within 1-year post-implant, with an all-cause mortality rate of 2.9% (95% confidence interval [CI], 2.3-3.8%). Four predicting models (Parkash, MADIT, AAACC, and MADIT-ICD non-arrhythmic mortality score) were significantly associated with increased risk of 1-year mortality with hazard ratios ranging from 3.75 (CI, 1.31-10.7) to 6.53 (CI 1.52-28.0, p ≤ 0.014 for all four). Positive predictive values of 1-year mortality were below 25% for all models. CONCLUSION: In our analysis, the models we tested conferred modest incremental predicting power to ordinary screening methods.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
10.
Europace ; 24(2): 234-244, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-34392336

RESUMEN

AIMS: We developed and validated an algorithm for prediction of heart failure (HF) hospitalizations using remote monitoring (RM) data transmitted by implanted defibrillators. METHODS AND RESULTS: The SELENE HF study enrolled 918 patients (median age 69 years, 81% men, median ejection fraction 30%) with cardiac resynchronization therapy (44%), dual-chamber (38%), or single-chamber defibrillators with atrial diagnostics (18%). To develop a predictive algorithm, temporal trends of diurnal and nocturnal heart rates, ventricular extrasystoles, atrial tachyarrhythmia burden, heart rate variability, physical activity, and thoracic impedance obtained by daily automatic RM were combined with a baseline risk-stratifier (Seattle HF Model) into one index. The primary endpoint was the first post-implant adjudicated HF hospitalization. After a median follow-up of 22.5 months since enrolment, patients were randomly allocated to the algorithm derivation group (n = 457; 31 endpoints) or algorithm validation group (n = 461; 29 endpoints). In the derivation group, the index showed a C-statistics of 0.89 [95% confidence interval (CI): 0.83-0.95] with 2.73 odds ratio (CI 1.98-3.78) for first HF hospitalization per unitary increase of index value (P < 0.001). In the validation group, sensitivity of predicting primary endpoint was 65.5% (CI 45.7-82.1%), median alerting time 42 days (interquartile range 21-89), and false (or unexplained) alert rate 0.69 (CI 0.64-0.74) [or 0.63 (CI 0.58-0.68)] per patient-year. Without the baseline risk-stratifier, the sensitivity remained 65.5% and the false/unexplained alert rates increased by ≈10% to 0.76/0.71 per patient-year. CONCLUSION: With the developed algorithm, two-thirds of first post-implant HF hospitalizations could be predicted timely with only 0.7 false alerts per patient-year.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Masculino , Volumen Sistólico
11.
Artículo en Inglés | MEDLINE | ID: mdl-34787731

RESUMEN

The variation between rest and peak stress end-systolic pressure-volume relation (ΔESPVR) is an index of myocardial contractility, easily obtained during routine stress echocardiography and never tested during dipyridamole stress-cardiac magnetic resonance (CMR). We assessed the ΔESPVR index in patients with known/suspected coronary artery disease (CAD) who underwent dipyridamole stress-CMR. One-hundred consecutive patients (24 females, 63.76 ± 10.17 years) were considered. ESPVR index was evaluated at rest and stress from raw measurement of systolic arterial pressure and end-systolic volume by biplane Simpson's method. The ΔESPVR index showed a good inter-operator reproducibility. Mean ΔESPVR index was 0.48 ± 1.45 mmHg/mL/m2. ΔESPVR index was significantly lower in males than in females. ΔESPVR index was not correlated to rest left ventricular end-diastolic volume index or ejection fraction. Forty-six of 85 patients had myocardial fibrosis detected by the late gadolinium enhancement technique and they showed significantly lower ΔESPVR values. An abnormal stress CMR was found in 25 patients and they showed significantly lower ΔESPVR values. During a mean follow-up of 56.34 ± 30.04 months, 24 cardiovascular events occurred. At receiver-operating characteristic curve analysis, a ΔESPVR < 0.02 mmHg/mL/m2 predicted the presence of future cardiac events with a sensitivity of 0.79 and a specificity of 0.68. The noninvasive assessment of the ΔESPVR index during a dipyridamole stress-CMR exam is feasible and reproducible. The ΔESPVR index was independent from rest LV dimensions and function and can be used for a comparative assessment of patients with different diseases. ΔESPVR index by CMR can be a useful and simple marker for additional prognostic stratification.

12.
ESC Heart Fail ; 8(6): 5204-5212, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34514741

RESUMEN

AIMS: There are conflicting data on the benefit of cardiac resynchronization therapy (CRT) in heart failure (HF) patients with permanent atrial fibrillation (AF). We aimed to compare patient outcomes according to the presence or absence of permanent AF at device implantation. METHODS AND RESULTS: We retrospectively analysed remote monitoring data from 1141 CRT defibrillators. Propensity score with inverse-probability weighting method was used to balance AF and sinus rhythm (SR) groups. Analysis endpoints included total mortality, appropriate defibrillation shocks, and CRT percentage. There were 229 patients (20.1%) in the AF group and 912 patients (79.9%) in the SR group. Compared with SR patients, AF patients were older (median age, 77 vs. 72 years, P < 0.001), more frequently male (82.5% vs. 75.5%, P = 0.02), and had higher heart rate (75.7 vs. 71.0 b.p.m., P < 0.001). Of the 229 AF patients, 162 (70.7%) received suboptimal CRT (<98%) and 67 (29.3%) had adequate CRT (≥98%). During a median follow-up of 24 months, total mortality did not differ between AF and SR groups (propensity-score-weighted hazard ratio, HR 1.32 [95% confidence interval, 0.82-2.15], P = 0.25). The risk of appropriate shocks was significantly higher in the AF group with <98% CRT than in the SR group (weighted-HR, 1.99 [1.21-3.26], P = 0.006) and was similar in the AF group with ≥98% CRT versus the SR group (1.29 [0.66-2.53], P = 0.45). During follow-up, sinus rhythm was recovered in 23 patients in the AF group (10%) after a median time of 106 (42-256) days. The rate of sinus rhythm recovery in the AF group was 4.5 (95% CI, 2.8-6.7) per 100 patient-years; the rate of permanent AF occurrence in the SR group was 2.5 (95% CI, 1.9-3.3) per 100 patient-years. CONCLUSIONS: Although mortality was similar across patient groups, patients with permanent AF and suboptimal CRT had twofold higher risk of appropriate shocks than SR patients or AF patients with CRT ≥ 98%.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Anciano , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Terapia de Resincronización Cardíaca/métodos , Desfibriladores , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34252991

RESUMEN

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento
14.
TH Open ; 5(2): e200-e210, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34151138

RESUMEN

A significant problem for patients undergoing oral anticoagulation therapy is gastrointestinal bleeding (GIB), a problem that has become increasingly urgent following the introduction of direct oral anticoagulants (DOACs). Furthermore, in recent years a greater focus has been placed on the quality of life (QOL) of patients on long-term oral anticoagulant therapy, which necessitates changes in lifestyle, as well as posing an increased risk of bleeding without producing objective symptomatic relief. Here, we examine current evidence linked to GIB associated with oral anticoagulants, with a focus on randomized control trials, meta-analyses, and postmarketing observational studies. Rivaroxaban and dabigatran (especially the 150-mg bis-in-die dose) appeared to be linked to an increased risk of GIB. The risk of GIB was also greater when edoxaban was used, although this was dependent on the dose. Apixaban did not pose a higher risk of GIB in comparison with warfarin. We provided a summary of current knowledge regarding GIB risk factors for individual anticoagulants, prevention strategies that lower the risk of GIB and management of DOAC therapy after a GIB episode.

15.
Int J Cardiol Heart Vasc ; 32: 100724, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33532544

RESUMEN

BACKGROUND: COVID-19 pandemic impacted on heart failure patients' lifestyle and quality of life, affecting both physical activity levels and state of health. METHODS: Demographic data and device records were extracted for patients with heart failure in the 16 weeks at the turn of lockdown during pandemic. To explore the variability across the lockdown period, a week-to-week analysis was performed. Patients were interviewed to investigate physical activity and psychological insights. The primary endpoint was the variation in physical activity at the turn of lockdown. RESULTS: At our facility, 2225 patients implanted with a cardiac device were screened and data were collected for 211 patients fulfilling the inclusion criteria. Patients' physical activity significantly decreased in the lockdown period compared with the control period (active time per day 8.0% vs. 10.8%; relative reduction [RRR] 25.9%; p < 0.0001). A small decrease was noted for mean heart rate (70.1 vs. 71.7 beats per minute [bpm]; RRR 2.2%; p < 0.0001), while thoracic impedance slightly increased (82.2 vs. 82.7 ohm; RRR 0.6%; p = 0.001). Patients' physical activity decreased from week 7 to week 11 (10.9% vs. 6.9%; RRR 36.7%; P < 0.0001) with an increase between week 11 and week 16 (6.9% vs. 8.5%; RRR 18.8%; P < 0.0001). Patients' perceptions about physical activity showed a very low correlation with remote monitoring-assessed physical activity levels (r2 = 0.035, p = 0.039). CONCLUSIONS: Telemedicine and remote monitoring can explore the impact of COVID-19 pandemic on vital signs and physical activity levels of heart failure patients, playing a crucial role in the prediction of heart failure worsening during circumstances discouraging outpatient visits.

16.
Int J Cardiol ; 327: 209-216, 2021 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-33309634

RESUMEN

BACKGROUND: Current medication adherence telemonitoring systems have several limitations prompting the need for simpler, low-cost and widely applicable tools. To meet these needs, we propose a novel method consisting in sending a digital feedback of medication intake by just reading a pre-defined Quick Response (QR) code attached on the pills box. METHODS: To assess the potential clinical applicability of the proposed QR code-based task, its feasibility was tested among elderly with heart diseases. The primary endpoint was the learning success defined as a correct execution of all QR code-based digital task steps within 10 min. Study outcomes were compared between patients 65-75 years old (younger cohort) and those aged >75 years (older cohort) admitted to the Cardiology ward of a tertiary center. RESULTS: A total of 262 patients were included: 128 (48.9%) were younger and 134 (51.1%) older. Despite a baseline low smartphone use in the overall population (41.2%), patients learning success of the digital task was as high as 75.6%, with lower rates among older vs. younger (67.9% vs. 83.6%, p = 0.005). After adjustment no significant independent association between age and success in learning the QR code-based task was found. Differently, increasing age was a negative independent predictor of smartphone use. The learning time was overall small, but longer in the older group (126 ± 100 vs. 100 ± 60 s, p = 0.03). CONCLUSIONS: The QR code-based digital task was highly feasible for elderly with heart diseases suggesting its potential large-scale clinical application and encouraging the investigation of QR code-based systems for medication adherence telemonitoring.


Asunto(s)
Cardiopatías , Preparaciones Farmacéuticas , Anciano , Retroalimentación , Humanos , Cumplimiento de la Medicación , Teléfono Inteligente
17.
J Arrhythm ; 36(2): 353-362, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32256887

RESUMEN

BACKGROUND: Parameters measured during implantable cardioverter defibrillator (ICD) implant also depend on bioelectrical properties of the myocardium. We aimed to explore their potential association with clinical outcomes in patients with single/dual-chamber ICD and cardiac resynchronization therapy defibrillator (CRT-D). METHODS: In the framework of the Home Monitoring Expert Alliance, baseline electrical parameters for all implanted leads were compared by the occurrence of all-cause mortality, adjudicated ventricular arrhythmia (VA), and atrial high-rate episode lasting ≥24 hours (24 h AHRE). RESULTS: In a cohort of 2976 patients (58.1% ICD) with a median follow-up of 25 months, event rates were 3.1/100 patient-years for all-cause mortality, 18.1/100 patient-years for VA, and 9.3/100 patient-years for 24 h AHRE. At univariate analysis, baseline shock impedance was consistently lower in groups with events than without, with a 40 Ω cutoff that better identified high-risk patients. However, at multivariable analysis, the adjusted-hazard ratios (HRs) lost statistical significance for any endpoint. Baseline atrial sensing amplitude during sinus rhythm was lower in patients with 24 h AHRE than in those without (2.45 [IQR: 1.65-3.85] vs 3.51 [IQR: 2.37-4.67] mV, P < .01). The adjusted HR for 24 h AHRE in patients with atrial sensing >1.5 mV vs those with values ≤1.5 mV was 0.52 (95% CI: 0.33-0.83), P = .006. CONCLUSIONS: Although lower baseline shock impedance was observed in patients with events, the association lost statistical significance at multivariable analysis. Conversely, low sinus rhythm atrial sensing (≤1.5 mV) measured with standard transvenous leads could identify subjects at high risk of atrial arrhythmia.

18.
J Cardiovasc Electrophysiol ; 31(4): 846-853, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32064713

RESUMEN

INTRODUCTION: Atrial tachycardia/fibrillation (AT/AF) episodes are common in implantable cardioverter-defibrillator (ICD) recipients and can be undetected by standard single-chamber devices. This study aims to explore whether a single-lead ICD with an atrial dipole (ICD DX; BIOTRONIK SE & Co, Berlin, Germany) could improve the AT/AF diagnosis and management as compared to standard ICD (ICD VR). METHODS AND RESULTS: We selected patients without AT/AF history from the THINGS registry which included consecutive patients implanted with ICD for standard indications. The ICD VR and the ICD DX groups included 236 (62.8%) and 140 (37.2%) patients, respectively, and had no significant differences in baseline characteristics. During a median follow-up of 27 months, there were 7 AT/AF diagnoses in the ICD VR and 18 in the ICD DX group. The 2-year incidence of AT/AF diagnosis was 3.6% (95% confidence interval [CI]: 1.6%-9.6%) for the ICD VR and 11.4% (95% CI: 6.8%-18.9%) for the ICD DX group (adjusted hazard ratio [HR]: 3.85 [95% CI: 1.58-9.41]; P = .003). Initiation of oral anticoagulation (OAC) due to AT/AF diagnosis was reported in 15 patients. The 2-year incidence of OAC onset was 3.6% (95% CI: 1.6%-7.8%) for the ICD VR and 6.3% (95% CI: 3.0%-12.7%) for ICD DX group (adjusted HR: 1.99 [95% CI: 0.72-5.56]; P = .184). CONCLUSION: We observed that atrial sensing capability in single-chamber ICD patients without evidence of atrial arrhythmias at implant is associated with a greater likelihood of detecting AT/AF episodes. The management of these diagnosed arrhythmias often led to clinical interventions, mainly represented by initiation of OAC therapy.


Asunto(s)
Fibrilación Atrial/diagnóstico , Función Atrial , Cardiomiopatías/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Insuficiencia Cardíaca/terapia , Taquicardia Supraventricular/diagnóstico , Administración Oral , Anciano , Antiarrítmicos/administración & dosificación , Anticoagulantes/administración & dosificación , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Cardiomiopatías/diagnóstico , Cardiomiopatías/epidemiología , Cardiomiopatías/fisiopatología , Ablación por Catéter , Cardioversión Eléctrica/efectos adversos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Taquicardia Supraventricular/epidemiología , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/terapia , Factores de Tiempo , Resultado del Tratamiento
19.
Eur Heart J Suppl ; 22(Suppl L): L41-L43, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33654465

RESUMEN

Management of recent-onset (<36 h) atrial fibrillation (AF) in the emergency room is highly variable, particularly concerning the type and timing of cardioversion, and the logistics of the treatment pathway. In clinical practice, it is fairly common for patients with recent-onset AF an attempt at re-establishing sinus rhythm, either with electric or pharmacologic cardioversion, as soon as feasible. Nonetheless, a 'wait-and-see' approach, and potentially delayed cardioversion, could represent a valid alternative to early cardioversion, considering that, often, in recent-onset AF, sinus rhythm is re-established spontaneously, thus repealing the need for active cardioversion, hence avoiding the possible risks of treatment. These concepts form the rationale for a recent multicentric randomized trial, Rate Control vs. Electrical Cardioversion Trial 7 - Acute Cardioversion vs. Wait and See (RACE 7 ACWAS), comparing the efficacy of delayed cardioversion, within 48 h from symptoms onset, in case of lack of spontaneous conversion, with early cardioversion in symptomatic patients with recent-onset AF. In patients presenting to the emergency department with recent-onset, symptomatic AF, a wait-and-see approach was non-inferior to early cardioversion in maintaining the sinus rhythm at 4 weeks. Nonetheless a system employing a delayed cardioversion strategy increases the costs of treatment, complicates the treatment pathway, and could represent a psychological burden for the patients. Accordingly, delayed cardioversion could not represent a practical choice for many hospitals with limited resources and without an adequate outpatient organization.

20.
JACC Clin Electrophysiol ; 5(10): 1197-1208, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31648745

RESUMEN

OBJECTIVES: This study evaluated the temporal association between atrial high-rate episodes (AHREs) and sustained ventricular arrhythmias (VAs) in a remotely monitored cohort with implantable cardioverter-defibrillators (ICD) with and/or without cardiac resynchronization therapy with a defibrillator (CRT-D). BACKGROUND: Clinical relevance of AHREs in terms of VA rate and survival has not been outlined yet. METHODS: This study analyzed data of patients with ICDs and CRT-Ds from the nationwide Home Monitoring Expert Alliance network. The cohort included 2,435 patients with a median follow-up of 25 months (interquartile range: 13 to 42 months) and age 70 years (range 61 to 77 years); 19.7% were women, 51.4% had coronary artery disease, and 45.2% had a CRT-D. There were 3,410 appropriate VA episodes; 498 (14.6%) were preceded by AHREs within 48 h; in 85.5% of this group, AHREs were still ongoing at episode onset. RESULTS: In a longitudinal analysis, the odds ratios (ORs) of experiencing any VA in a 30-day interval with AHREs versus intervals without AHREs were 2.35 (95% confidence interval [CI]: 1.86 to 2.97; p < 0.001) for ventricular tachycardia (VT), 3.06 (95% CI: 2.35 to 3.99; p < 0.001) for fast VT, 1.84 (95% CI: 1.36 to 2.48; p < 0.001) for self-extinguishing ventricular fibrillation (VF), and 2.31 (95% CI: 1.17 to 4.57; p = 0.01) for VF. ORs decreased with increasing AHRE burden. Patients with AHREs 48 h before VAs were more likely to experience VA recurrences (adjusted hazard ratio [HR]: 1.78; 95% CI: 1.41 to 2.24; p < 0.001) and had higher overall mortality (HR: 2.67; 95% CI: 1.68 to 4.23; p < 0.001). CONCLUSIONS: AHREs were not uncommon 48 h before VAs, which tended to be distributed around intervals with AHREs. Temporal connection between AHREs and VAs was a marker of increased risk of VA recurrence and a poorer prognosis.


Asunto(s)
Fibrilación Atrial/epidemiología , Aleteo Atrial/epidemiología , Mortalidad , Taquicardia Supraventricular/epidemiología , Taquicardia Ventricular/epidemiología , Fibrilación Ventricular/epidemiología , Anciano , Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Tecnología de Sensores Remotos , Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...