RESUMEN
OBJECTIVES: To review the effects of physical activity on health and behavior outcomes and develop evidence-based recommendations for physical activity in youth. STUDY DESIGN: A systematic literature review identified 850 articles; additional papers were identified by the expert panelists. Articles in the identified outcome areas were reviewed, evaluated and summarized by an expert panelist. The strength of the evidence, conclusions, key issues, and gaps in the evidence were abstracted in a standardized format and presented and discussed by panelists and organizational representatives. RESULTS: Most intervention studies used supervised programs of moderate to vigorous physical activity of 30 to 45 minutes duration 3 to 5 days per week. The panel believed that a greater amount of physical activity would be necessary to achieve similar beneficial effects on health and behavioral outcomes in ordinary daily circumstances (typically intermittent and unsupervised activity). CONCLUSION: School-age youth should participate daily in 60 minutes or more of moderate to vigorous physical activity that is developmentally appropriate, enjoyable, and involves a variety of activities.
Asunto(s)
Actividad Motora/fisiología , Logro , Asma/fisiopatología , Asma/prevención & control , Presión Sanguínea/fisiología , Índice de Masa Corporal , Densidad Ósea/fisiología , Niño , Colesterol/sangre , Humanos , Salud Mental , Síndrome Metabólico/prevención & control , Músculo Esquelético/fisiología , Resistencia Física/fisiología , Aptitud Física/fisiología , Heridas y Lesiones/epidemiologíaRESUMEN
This paper describes two simple thermal methods for measuring the energy fluence in J/cm2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.