Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Neurophysiol ; 112(6): 1566-83, 2014 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-24920021

RESUMEN

Our understanding of the large-scale population dynamics of neural activity is limited, in part, by our inability to record simultaneously from large regions of the cortex. Here, we validated the use of a large-scale active microelectrode array that simultaneously records 196 multiplexed micro-electrocortigraphical (µECoG) signals from the cortical surface at a very high density (1,600 electrodes/cm(2)). We compared µECoG measurements in auditory cortex using a custom "active" electrode array to those recorded using a conventional "passive" µECoG array. Both of these array responses were also compared with data recorded via intrinsic optical imaging, which is a standard methodology for recording sound-evoked cortical activity. Custom active µECoG arrays generated more veridical representations of the tonotopic organization of the auditory cortex than current commercially available passive µECoG arrays. Furthermore, the cortical representation could be measured efficiently with the active arrays, requiring as little as 13.5 s of neural data acquisition. Next, we generated spectrotemporal receptive fields from the recorded neural activity on the active µECoG array and identified functional organizational principles comparable to those observed using intrinsic metabolic imaging and single-neuron recordings. This new electrode array technology has the potential for large-scale, temporally precise monitoring and mapping of the cortex, without the use of invasive penetrating electrodes.


Asunto(s)
Corteza Auditiva/fisiología , Mapeo Encefálico/instrumentación , Electroencefalografía/instrumentación , Animales , Mapeo Encefálico/métodos , Electroencefalografía/métodos , Potenciales Evocados Auditivos , Masculino , Microelectrodos , Imagen Óptica/métodos , Ratas
2.
Artículo en Inglés | MEDLINE | ID: mdl-25570162

RESUMEN

While mammography remains the gold standard for breast cancer screening, additional adjunctive tools for early detection of breast cancer are needed especially for young women, women with dense breast tissue and those at increased risk due to genetic factors. These patient populations, along with those populations for whom mammography is not readily available, require alternative technologies capable of effectively detecting breast cancer. One such adjunctive modality for breast cancer detection is Electrical Impedance Tomography (EIT). It is a non-invasive technique that measures tissue conductivity by injecting a small current through a surface electrode while measuring electrode voltage(s). The surface measurements are then used to reconstruct a conductivity mapping of the tissue. The difference in conductivities between healthy tissue and that of carcinoma enable EIT to detect cancer. Electrical Impedance Tomography does not subject the patient to ionizing radiation, and offers significant potential for detecting very small tumors in early stages of development at a low cost. While prior systems have demonstrated success using EIT for breast cancer detection, the resolution of the reconstructed image was limited by the spatial resolution of the sensing electrode array. Here, we report the use of higher density (3mm spacing) flexible micro-electrode arrays to obtain tissue impedance maps. Accurate EIT reconstruction is highly dependent on the spatial resolution and fidelity of the surface measurements. High-density, flexible arrays that conform to the breast surface can offer great potential in reconstructing higher resolution conductivity maps than have been previously achieved.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Detección Precoz del Cáncer/métodos , Tomografía/métodos , Impedancia Eléctrica , Electrodos , Femenino , Humanos , Mamografía/métodos , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA