Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Clin Exp Dent ; 16(6): e733-e739, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39130363

RESUMEN

Background: This research aimed to analyze the influence of root canal taper on the accuracy of two Electronic Apex Locators (EALs). Material and Methods: Twenty-five disto-vestibular roots from extracted human upper molars belonging to the tooth bank were used in this study. To determine the File Position (FP), access was made using a spherical diamond tip #1014, and the crowns were sectioned using a diamond tip #3080. The initial anatomic file used was a size K #10, which was introduced into the root canal until its tip was visualized (foraminal patency) with the aid of a clinical microscope (16X magnification). Teeth without foraminal patency and calcifications were excluded from the study. Odontometric readings were performed using two different EALs (Root ZX II and Romiapex A-15), considering the electronic reference point 0.0 (apex) for each device. All measurements were taken in triplicate, and the arithmetic mean of the three values was used. Digital calipers were used to record the measurements, which were then entered into an Excel spreadsheet. After visual verification using file K #10, the canals were instrumented with a #25.01 file to standardize the apical region, then successively instrumented with files #25.02, #25.04, #25.06, #25.08, #25.10, and #25.12, with electronic odontometry checked after each instrumentation using #25.02. Measurement 0.0 was adopted, with error margins of ±0.5 and ±1.0. Discrepancies between visual and electronic readings were statistically analyzed using ANOVA and Bonferroni tests, with significance considered when P<0.05. Results: Using the 0.0 mark and a ±1.0 error margin, it was observed that readings from the devices were similar in canals with different tapers (P>0.05), showing a tendency towards underestimation. However, when using the measurement variation margin of ±0.50, a statistically significant difference was found in the Romiapex A-15 group (P=0.0248) when comparing the results of the two EALs. Conclusions: Therefore, it was concluded that the canal taper did not significantly influence the accuracy of the evaluated EALs, using the reference point 0.0. When using the ±0.5 variation margin, the Romiapex A-15 device showed greater accuracy, and finally, at the ±1.0 error margin, both EALs exhibited excellent precision. Key words:Endodontics, Odontometry, Eletronic Apex Locator, Root Canal Preparation.

2.
J Clin Exp Dent ; 16(3): e257-e262, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38600923

RESUMEN

The present study aimed to evaluate the accuracy of four different Electronic Foraminal Locators (EFLs): Root ZX II (J. Morita, Tokyo, Japan), RomiApex A15 (Romidan, Kiryat-Ono, Israel), FinePex (Schuster, Porto Alegre, Brazil) and VDW Gold (VDW, Munich, Germany), in determining root length during endodontic retreatment steps. Twenty-seven human unirooted teeth had their crowns sectioned to standardize the teeth to 17 mm. The actual tooth length was visualized with an operating microscope and a #15 file juxtaposed to the apical foramen. Teeth were instrumented with files R25 and R40, and at the end of each instrumentation, measurements of root canal lengths were made with files #25 and #40. Then, the teeth had their root canals filled with standardized Gutta-Percha R40 cones and Endofill cement, and after seven days, they were uncovered with R25 and R40 files, respectively. New measurements were made with #25 and #40 files between the uncovering with each file. The data were statistically analyzed by ANOVA and Chi-square tests, considered significant when P<0.05. All devices tended to under-measurement when the obturating material was partially removed with the R25 file. When the canals were uncovered with the R40 instrument, the effectiveness of the appliances increased significantly (P<0.05). At 0.40 mm diameter, the mean accuracy of the Romiapex A15 appliance was statistically lower than the other EFLs (P<0.001), showing a tendency to over-measurement. In conclusion, all the tested appliances showed similar efficacy when acceptable limits were observed. The permanence of the remaining filling material in the apical third influenced the accuracy and efficacy of EFLs in endodontic retreatment cases. Key words:Endodontics, odontometry, apical foramen.

3.
Braz Dent J ; 35: e245611, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537014

RESUMEN

This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Humanos , Preparación del Conducto Radicular/métodos , Ultrasonido , Irrigantes del Conducto Radicular , Irrigación Terapéutica/métodos , Microtomografía por Rayos X , Dentina
4.
J Clin Exp Dent ; 16(1): e18-e24, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38314341

RESUMEN

Background: To evaluate the accuracy of four different Electronic Foraminal Locators (EFLs): Root ZX II (J. Morita, Tokyo, Japan), Romiapex A15 (Romidan, Kiryat-Ono, Israel), FinePex (Schuster, Porto Alegre, Brazil), and VDW Gold (VDW, Munich, Germany), in determining root canal length. Material and Methods: Twenty-seven human single-rooted teeth had their crowns sectioned at the cementoenamel junction, and the actual length of the tooth was obtained by visualizing with an operative microscope a #15 file placed adjacent to the apical foramen. The teeth were instrumented with R25 and R40 files, and at the end of each instrumentation, measurements of the lengths of the root canals were made with #25 and #40 files. The data were statistically analyzed by ANOVA and chi-square tests and were considered significant when P<0.05. All devices showed a tendency to underestimate measurements by 0.25 mm diameter. Results: The mean accuracy of the Root ZX II appliance was statistically lower than the other EFLs (P<0.001). For the 0.40 mm diameter, the mean accuracy of the Romiapex A15 appliance was statistically higher than the other LEFs (P<0.001). However, when the diameter was 0.40 mm, only the Romiapex A15 device tended to overmeasure. Regarding the acceptable limits of variation, it was observed that the devices showed similar efficiency in determining odontometry (P>0.05), both with diameters of 0.25 mm and 0.40 mm. Conclusions: It was concluded that the devices presented similar and adequate efficacy when observing the limits of acceptable measurements. It was observed that increasing the apical diameter did not influence the accuracy of EFLs in determining root canal lengths. Key words:Endodontics, working length, electronic foraminal locators, endodontic treatment.

5.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1550086

RESUMEN

Abstract This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Resumo Este estudo avaliou a correlação entre a curvatura do canal radicular e os efeitos da irrigação ultrassônica nos seguintes parâmetros: volume de remoção não controlada de dentina (UDRVol), profundidade máxima do desgaste de dentina, remoção de debris de tecido duro acumulado (AHTD) e transporte em canais radiculares curvos. Vinte e quatro molares inferiores humanos permanentes foram divididos em dois grupos de acordo com a curvatura do canal radicular: curvatura moderada (MC: média de 25°); e curvatura acentuada (SC: média de 48°). Os espécimes foram digitalizados usando um scanner microcomputador de raios X (Skyscan 1172) antes e depois da limpeza e modelagem e após a irrigação ultrassônica. Houve uma correlação moderada entre o grau de curvatura do canal radicular e o volume de AHTD remanescente (p<0,05) e entre o grau de curvatura do canal radicular e a profundidade máxima de defeitos devido à remoção descontrolada de dentina (p<0,05). Os dentes do grupo SC apresentaram maior profundidade máxima de defeitos na parede dentinária no terço apical do que os dentes do grupo MC (p<0,05). Ambos os grupos tiveram uma redução significativa de AHTD em todos os terços do canal, mas a quantidade de AHTD remanescente nos terços médio e apical e em todo o canal foi significativamente maior no grupo SC do que no grupo MC (p <0,05). O transporte do canal não foi influenciado pela curvatura do canal em todos os terços (p > 0,05). Este estudo concluiu que a curvatura do canal radicular afeta significativamente a remoção descontrolada de dentina e o volume remanescente de AHTD após a irrigação ultrassônica.

6.
Braz. dent. sci ; 27(2): 1-8, 2024. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1567092

RESUMEN

Objective: This study evaluated different methods of calcium hydroxide (CH) removal from root canals with simulated internal resorptions using microcomputed tomography (micro-CT). Material and Methods: Sixty acrylic resin blocks with simulated root canals and internal resorptions were prepared using a Reciproc R25 file and then filled with CH. The blocks were divided into five test groups (n=12) according to the method used for CH removal: hand files (HF), Easy Clean (EC), passive ultrasonic irrigation (PUI), XP-Endo Finisher (XP), XP-Endo Finisher + PUI (XP+PUI). The blocks were scanned using a SkyScan 1172 scanner before and after CH removal to measure the volume and percentage of CH removal. The OriginPro 2017 software was used for statistical analyses. The level of significance was set at p<0.05 for all tests. Results: No method under study removed all CH. All methods had similar results in the cervical third (P>0.05). The percentage of CH removal was significantly greater in the area of internal resorption and along the total length of the canal in the XP+PUI group (P<0.05). The best results of CH removal were found in the apical third of roots in the XP+PUI and PUI groups (P>0.05). Conclusion: No method removed all CH from the root canals, but the combined XP+PUI method removed more CH than the other methods, especially from the area of the internal resorption(AU)


Objetivo: Este estudo avaliou diferentes métodos de remoção de hidróxido de cálcio (CH) de canais radiculares com reabsorções internas simuladas por meio de microtomografia computadorizada (micro-CT). Material e Métodos: Sessenta blocos de resina acrílica com canais radiculares simulados e reabsorções internas foram preparados com lima Reciproc R25 e posteriormente preenchidos com CH. Os blocos foram divididos em cinco grupos de teste (n=12) de acordo com o método utilizado para remoção de CH: limas manuais (HF), Easy Clean (EC), irrigação ultrassônica passiva (PUI), XP-Endo Finisher (XP), XP -Endo Finalizador + PUI (XP + PUI). Os blocos foram escaneados usando um scanner SkyScan 1172 antes e depois da remoção do CH para medir o volume e a porcentagem de remoção do CH. O software OriginPro 2017 foi utilizado para análises estatísticas. O nível de significância foi estabelecido em p<0,05 para todos os testes. Resultados: Nenhum método em estudo removeu todos o CH. Todos os métodos tiveram resultados semelhantes no terço cervical (P>0,05). A porcentagem de remoção de CH foi significativamente maior na área de reabsorção interna e ao longo do comprimento total do canal no grupo XP+PUI (P<0,05). Os melhores resultados de remoção de CH foram encontrados no terço apical das raízes nos grupos XP+PUI e PUI (P>0,05). Conclusão: Nenhum método removeu todo o CH dos canais radiculares, mas o método combinado XP+PUI removeu significativamente mais CH do que os outros métodos, especialmente da área de reabsorção interna (AU)


Asunto(s)
Resorción Dentaria , Hidróxido de Calcio , Instrumentos Dentales , Cavidad Pulpar , Microtomografía por Rayos X
7.
J Clin Exp Dent ; 15(11): e938-e944, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38074173

RESUMEN

Background: This study aimed to assess the knowledge of Brazilian endodontists regarding the use of cone beam computed tomography (CBCT) in endodontic therapy. Material and Methods: An invitation to participate in the research was sent to 3256 professionals through class groups on social networks and via email. Participants answered an online questionnaire consisting of 11 questions about the clinical situations in which they used CBCT and whether they had any knowledge of the technical protocols such as parameters of field of view (FOV) and voxels of the CBCT equipment. The questionnaire was answered by 742 endodontists who represented 22.7% of the invited professionals. Results: The data obtained indicate that 76.7% of the participants use or have used CBCT during endodontic treatments. The most often reported clinical conditions for using the CBCT were: root fractures (64%), locating the canals (58.7%), perforations (53.9%), and root resorption (42.1%). More than 60% of the participants stated that they do not have information about the voxel, FOV, and the CBCT system used in their requests. Only 34.1% reported using CBCT to the performed endodontic treatments follow-up. Conclusions: CBCT was a tool widely utilized by the participants, with root fracture being the clinical condition with the highest indication for CBCT. Many professionals were unaware of the technical protocol used in the exams. Key words:Endodontics, Cone Beam Computed Tomography, Endodontic Therapy.

8.
Braz Dent J ; 34(3): 25-32, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37466522

RESUMEN

This study aimed to evaluate the tissue repair capacity of four bioceramic endodontic sealers by quantifying type I and III collagen fibers. The following sealers were tested: EndoSequence BC Sealer (Brasseler, Brasseler, Savannah, USA), Bio C Sealer (Angelus, Londrina, Brazil), Bioroot RCS (Septodont, Santa Catarina, Brazil), and Sealer Plus BC (MKLife, Porto Alegre, Brazil). Polyethylene tubes 1.5 mm in diameter and 1 cm in length containing the endodontic sealers were implanted in the subcutaneous tissue of five rats (Rattus norvegicus albinus, Wistar lineage). After 14 days, the animals were euthanized, and collagen fibers were quantified from the histological tissue sections. Given a non-normal distribution of the data, a gamma regression with log link function was employed and implemented through the generalized linear models module, was used to test whether there was a significant difference between the sealers. The pairwise comparison was performed using Least significant difference. There were significant differences between the sealers for type I (p=0.001), type III (p=0.023), and total collagen (p=0.002). Overall, Bioroot sealer was statistically superior to the other sealers, except in the analysis of type III collagen, in which there was no difference between the Bioroot sealer and Bio C Sealer sealer and the control group (p>0.05). Bioroot RCS bioceramic endodontic sealer stimulates a greater production of collagen.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Ratas , Animales , Resinas Epoxi , Compuestos de Calcio , Tejido Subcutáneo , Ensayo de Materiales , Ratas Wistar , Silicatos , Colágeno
9.
Restor Dent Endod ; 48(2): e17, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37284340

RESUMEN

The present report describes the endodontic treatment of an Oehlers type II dens invaginatus in a maxillary lateral incisor with 5 root canals, an extremely rare condition. Apical periodontitis and related symptoms were noted. Cone-beam computed tomography was used to aid the diagnosis, reveal tooth morphology, and assist in canal location. The pulp chamber was carefully accessed, and the root canals were explored under magnification. All root canals were prepared with an R25 Reciproc Blue system and sodium hypochlorite (NaOCl) irrigation. After initial preparation, a self-adjusting file (SAF) with NaOCl and ethylenediaminetetraacetic acid was used to complement the disinfection. Additionally, calcium hydroxide medication was applied. Vertical compaction was used to fill the canals with a calcium silicate-based endodontic sealer and gutta-percha. After 12 months, the patient exhibited healing of the periapical region, absence of symptoms, and normal dental function. In conclusion, this nonsurgical treatment protocol was successful in promoting the cure of apical periodontitis. Both complementary disinfection with an SAF and use of calcium hydroxide medication should be considered when choosing the best treatment approach for dens invaginatus with very complex anatomy.

10.
Braz. dent. j ; 34(3): 25-32, May-June 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1447604

RESUMEN

Abstract This study aimed to evaluate the tissue repair capacity of four bioceramic endodontic sealers by quantifying type I and III collagen fibers. The following sealers were tested: EndoSequence BC Sealer (Brasseler, Brasseler, Savannah, USA), Bio C Sealer (Angelus, Londrina, Brazil), Bioroot RCS (Septodont, Santa Catarina, Brazil), and Sealer Plus BC (MKLife, Porto Alegre, Brazil). Polyethylene tubes 1.5 mm in diameter and 1 cm in length containing the endodontic sealers were implanted in the subcutaneous tissue of five rats (Rattus norvegicus albinus, Wistar lineage). After 14 days, the animals were euthanized, and collagen fibers were quantified from the histological tissue sections. Given a non-normal distribution of the data, a gamma regression with log link function was employed and implemented through the generalized linear models module, was used to test whether there was a significant difference between the sealers. The pairwise comparison was performed using Least significant difference. There were significant differences between the sealers for type I (p=0.001), type III (p=0.023), and total collagen (p=0.002). Overall, Bioroot sealer was statistically superior to the other sealers, except in the analysis of type III collagen, in which there was no difference between the Bioroot sealer and Bio C Sealer sealer and the control group (p>0.05). Bioroot RCS bioceramic endodontic sealer stimulates a greater production of collagen.


Resumo Este estudo visou avaliar a capacidade de reparação de tecidos de quatro cimentos endodônticos biocerâmicos através da quantificação de fibras colágenas de tipo I e III. Foram testados os seguintes cimentos: EndoSequence BC Sealer (Brasseler, Brasseler, Savannah, EUA), Bio C Sealer (Angelus, Londrina, Brasil), Bioroot RCS (Septodont, Santa Catarina, Brasil), e Sealer Plus BC (MKLife, Porto Alegre, Brasil). Foram implantados tubos de polietileno de 1,5 mm de diâmetro e 1 cm de comprimento contendo os cimentos endodônticos no tecido subcutâneo de cinco ratos (Rattus norvegicus albinus, linhagem Wistar). Após 14 dias, os animais foram eutanasiados e as fibras colágenas foram quantificadas a partir de cortes histológicos do tecido. Diante de uma distribuição não-normal dos dados, uma regressão gama com função de ligação log, implementada por meio do módulo de modelos lineares generalizados, foi empregada para testar se havia diferença significativa entre os cimentos. A comparação dois a dois foi realizada utilizando Least significant difference. Houve diferença significativa entre os cimentos para os colágenos tipo I (p=0,001), tipo III (p=0,023) e colágeno total (p=0,002). No geral, o cimento Bioroot foi estatisticamente superior aos demais cimentos, com exceção na análise do colágeno tipo III na qual não houve diferença entre o cimento Bioroot e o cimento Bio C Sealer e o grupo controle (p>0,05). O cimento endodôntico biocerâmico Bioroot RCS foi capaz de estimular uma maior produção de colágeno.

11.
J Dent Educ ; 86(6): 751-758, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35061917

RESUMEN

OBJECTIVES: The aim of this cross-sectional retrospective study was to evaluate radiographically the technical quality of root canal treatment performed by undergraduate students using reciprocating NiTi instrumentation and single-cone obturation. METHODS: Endodontic treatment on 1102 teeth performed by undergraduate students from the School of Dentistry of the University of Santa Cecilia (Brazil) was evaluated. All root canal preparations were performed using Reciproc files and were irrigated with 1% NaOCl. The root canal was filled with gutta-percha, along with AH Plus sealer, using the single-cone obturation technique. The technical quality of the root canal treatment was evaluated based on immediate postoperative radiographs. Distance between the end of the filling and the radiographic apex, the filling density, and the taper of the root filling was assessed. Inter-examiner agreement statistic (Kappa) and Chi-square statistic test were used for statistical evaluation of the results. Differences were considered statistically significant when p < 0.05. RESULTS: Anterior teeth, maxillary premolars, and molars presented better results than mandibular premolars and molars (p < 0.05). Mandibular premolars presented a high incidence of a short length of obturation (33.34%) and mandibular molars presented a high incidence of overfilling (6.55%). The majority of the treatment analyzed (62.46%) fulfilled all the criteria showing acceptable working length, taper, and density of obturation. Instrument fractures occurred in eighteen root canals (0.81%). CONCLUSIONS: The use of NiTi reciprocating instruments with the single-cone obturation technique provided an acceptable quality of endodontic treatment in the majority of the cases performed by undergraduate students.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Estudios Transversales , Cavidad Pulpar , Humanos , Estudios Retrospectivos , Materiales de Obturación del Conducto Radicular/uso terapéutico , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular , Estudiantes
12.
J Contemp Dent Pract ; 23(10): 979-983, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37073909

RESUMEN

AIM: This study aimed to evaluate the spatial location of the second mesiobuccal canal (MB2) of maxillary molars (MMs), using cone-beam computed tomography (CBCT), in a Brazilian subpopulation. MATERIALS AND METHODS: The CBCT examination of 250 patients performed on the Eagle 3D device was analyzed, totaling 787 MMs. Using the Radiant Dicom Viewer software, measurements were made of the distances, in millimeters (mm), between the first mesiobuccal canal (MB1), MB2, and palatal (P) canal inputs, from the axial sections. The Image J software evaluated the angle formed by the lines. The data obtained were analyzed statistically by Fisher's exact and Chi-square tests with a significance of 5%. RESULTS: The prevalence of MB2 canals observed was 76.44 and 41.73% in the first and second molars (1MMs and 2MMs), respectively (p < 0.05). The average of the distances and angles performed, for the location of the MB2 canals of the analyzed teeth, were MB1-P = 5.83 mm, MB1-MB2 = 2.31 mm, and MB2 for the intersection of the connecting distance from MB2-T = 0.90 mm. The average angle formed between the MB1-P and MB1-MB2 distances was 25.89° and 19.68° for the 1MMs and 2MMs, respectively. It was also observed that 91.4 and 75.4% of the maxillary 1MMs and 2MMs, respectively, presented the MB2 canals mesially located at the line connecting the MB1-P canals (p < 0.0001). CONCLUSION: The MB2 canals were located mesially to the MB1 canal with an average distance of 2 mm between the canals. CLINICAL SIGNIFICANCE: The anatomical knowledge of the spatial location of the MB2 canal in different ethnicities is important for the planning and execution of endodontic treatment.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Diente Molar , Humanos , Brasil , Diente Molar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Cavidad Pulpar/diagnóstico por imagen , Maxilar/diagnóstico por imagen
13.
Aust Endod J ; 47(3): 544-549, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33913601

RESUMEN

This study evaluated the resistance to flexural fatigue and torsional strength of files for glide path preparation in continuous rotation or Optimum Glide Path motion (OGP). ScoutRace 15.02 and ProGlider 16.02 files were used in a dynamic testing device during preparation of simulating curved root canals (40-degree curvature and 5 mm radius). For the torsional test, a machine was used to test torsion measured maximum torsional strength (N.cm). Two-way anova and Tukey's multiple comparisons test were used for statistical analysis. Files in OGP motion had a statistically better resistance to flexural fatigue (P < 0.05). ProGlider files took longer time to failure than ScoutRace files only when OGP was used (P < 0.05). The torsional test revealed that OGP produced significantly less torsional stress than rotary motions for both types of glide path files (P < 0.05) In conclusion, OGP motion increased substantially the mechanical safety of endodontic glide path files.


Asunto(s)
Deportes , Proyectos de Investigación
14.
Braz Oral Res ; 34: e117, 2020 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-32901732

RESUMEN

The aim of this study was to assess Brazilian endodontists' level of knowledge about the coronavirus disease (COVID-19) and examine its professional repercussions. The link to the online survey that was created for this study was shared with Brazilian endodontists through social networking applications. The questionnaire contained questions that pertained to COVID-19 and its impact on dental practice. The collected data were analyzed using t-test, chi-square analysis, and analysis of variance, and the level of significance was set at 0.05. A total of 2,135 participants responded to the questionnaire, and all five Brazilian regions were represented in the sample. A total of 98.50% of endodontists reported that dental procedures can transmit COVID-19. Complete social distancing was practiced by 96.68% of the participants, and approximately 25% knew someone who had COVID-19. Moreover, in their daily practice, 72.13% of them implemented biosecurity measures that are ineffective in preventing COVID-19. Furthermore, 91.7% of them reportedly suspended elective dental procedures. Only 55.69% of them reported that they performed only emergency procedures in their workplaces. Those who believed that COVID-19 cannot be transmitted during dental procedures were less knowledgeable about the symptoms of COVID-19 (p = 0.0095). Endodontists who believed that personal protective equipment cannot prevent contamination were more knowledgeable about the symptoms of COVID-19 than their counterparts (p = 0.0003). The participating Brazilian endodontists demonstrated adequate knowledge about the risk of contamination during dental procedures and the main symptoms of COVID-19. Only some professionals reported providing emergency dental care during the pandemic.


Asunto(s)
Infecciones por Coronavirus/epidemiología , Endodoncistas , Conocimientos, Actitudes y Práctica en Salud , Neumonía Viral/epidemiología , Betacoronavirus , Brasil , COVID-19 , Infecciones por Coronavirus/transmisión , Endodoncia , Humanos , Pandemias , Neumonía Viral/transmisión , SARS-CoV-2 , Encuestas y Cuestionarios
15.
Aust Endod J ; 46(3): 381-386, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32820589

RESUMEN

This paper aims to report a case in which central giant cell granuloma (CGCG) mimicked a periapical lesion of endodontic origin. An 18-year-old female patient was referred for diagnosis and treatment of extensive radiolucent periapical lesion involving 31, 32, 33, 34 and 35 teeth. Clinically, the patient presented slight facial asymmetry and healthy teeth on the affected side with positive response to thermal vitality tests. Thus, an incisional biopsy was performed, which presented a histopathological picture characteristic of a CGCG. The endodontic treatment of the involved teeth was followed by surgical curettage of the lesion. After two years of follow-up, the patient was asymptomatic, with marked improvement in mandibular symmetry and adequate healing of the lesion. Therefore, the diagnosis of radiolucent periapical lesions must include lesions of endodontic and non-endodontic origin for better treatment planning and execution.


Asunto(s)
Granuloma de Células Gigantes , Adolescente , Diagnóstico Diferencial , Femenino , Granuloma de Células Gigantes/diagnóstico por imagen , Granuloma de Células Gigantes/cirugía , Humanos
16.
Dent. press endod ; 10(2): 42-47, maio-ago.2020. Tab, Ilus
Artículo en Inglés | LILACS | ID: biblio-1344547

RESUMEN

Objetivo: O objetivo do presente estudo foi avaliar a influência da liga (NiTi convencional e M-Wire) e do movimento (reciprocante e rotação contínua) na resistência à fadiga cíclica. Métodos: Quinze limas Reciproc R25 (VDW GmbH, Munique, Alemanha) foram usadas em movimento reciprocante (MR), enquanto trinta limas Mtwo 25.07 (VDW GmbH, Munique, Alemanha) foram usadas em MR (n=15) ou em rotação contínua (RC) (n=15). Os instrumentos foram submetidos a ensaios dinâmicos movidos por motor elétrico, que permitiram reproduzir o movimento de pecking motion, a 300rpm de velocidade. Os instrumentos simularam a instrumentação de um canal radicular curvo com 40o e 5mm de raio de curvatura. A fratura dos instrumentos foi detectada por um sensor digital, e o tempo e o número de ciclos foram registrados. Os dados foram analisados estatisticamente pelos testes ANOVA e de Tukey (p<0,05). Resultados: Os instrumentos Reciproc R25 movidos por MR alcançaram número significativamente maior (p<0,05) de ciclos antes da fratura (1.777,68±334,2 ciclos), quando comparados aos instrumentos MT 25.07 movidos por MR (610,67±126,3 ciclos) ou RC (432,23±183,2 ciclos). Conclusões: O movimento reciprocante mostrou resistência à fadiga cíclica significativamente maior, e os instrumentos de NiTi M-Wire apresentaram maior resistência à fadiga cíclica do que os instrumentos rotatórios de NiTi convencional (AU).


Objective: The aim of present study was to evaluate the influence of alloy (conventional NiTi and M-Wire NiTi) and movement (reciprocating movement and continuous rotation) on resistance to cyclic fatigue. Methods: Fifteen Reciproc R25 files (VDW GmbH, Munich, Germany) were used in reciprocation motion (RM), while thirty MTwo 25/.07 files (VDW GmbH, Munich, Germany) were used either in RM (n=15) or in continuous rotation (CR) (n=15). The files were submitted to dynamic assays device moved by electric engine that allowed the reproduction of pecking motion under 300 rpm of speed. The files act simulating the instrumentation of a curved root canal with 40º and 5-mm of curvature radius. The fracture was detected by the device sensor and the time and number of cycles were obtained. Data were statistically analyzed by ANOVA and Tukeys tests (p<0.05). Results: The Reciproc R25 instruments moved by RM reached significantly higher number (p<0.05) of cycles before fracture (1777.68 ± 334.2 cycles) when compared with MTwo 25/.07 instruments moved by RM (610.67 ± 126.3 cycles) or CR (432.23 ± 183.2 cycles). Conclusions: The reciprocation motion showed significantly greater cyclic fatigue resistance and the M-Wire NiTi files showed higher cyclic fatigue resistance than conventional NiTi rotary files (AU).


Asunto(s)
Rotación , Instrumentos Dentales , Endodoncia , Fatiga
17.
Dent. press endod ; 10(2): 29-33, maio-ago.2020. Tab
Artículo en Inglés | LILACS | ID: biblio-1344315

RESUMEN

Objetivo: O presente estudo teve como objetivo comparar três sistemas de instrumentação de NiTi, tratados termicamente, quanto ao número de condutos instrumentados até a fratura. Métodos: Foram utilizados 210 molares humanos inferiores e superiores com curvaturas leves a moderadas, comprimentos reais entre 19 e 21 mm e forames apicais até 200µm. Esses foram randomicamente divididos em três grupos de acordo com o sistema de instrumentação utilizado: Reciproc (REC; R25), ProDesign Duo Híbrido (PDH; #25/.01 e #25/.08) e TF Adaptive (TFA; #25/.08). Foram utilizados 5 instrumentos/kits de cada sistema. Registrou-se, então, o número de condutos instrumenta- dos até a fratura e o número de reinserções necessárias até o alcance do comprimento de trabalho. Resultados: A análise estatística apontou diferenças significativas quando comparada a durabilidade dos sistemas, tendo os instrumentos do grupo PDH oferecido os maiores valores (29,2), seguido de REC (21,6) e TFA (15,4) (p<0,05). Quanto ao número de reinserções, o sistema TFA foi o que necessitou do menor número de reinserções (p<0,05). Conclusão: Nas condições do estudo, pode-se concluir que o sistema ProDesign Duo Híbrido foi o mais durável; ainda que o sistema TF Adaptive tenha alcançado o comprimento de trabalho com maior facilidade


Objective: The present study compared three systems of thermally treated NiTi endodontic files regarding their achieved number of prepared root canals before fracture. Methods: Two hundred and ten slightly and moderately curved upper and lower molars with actual length ranging from 19 to 21 mm and apex foramens diameters up to 200 µm were used. The sample was allotted to three groups according to the instrumentation system in use: Reciproc (REC; R25), ProDesign Duo Hybrid (PDH; #25/.01 and #25/.08), and TF Adaptive (TFA; #25/.08). Five instruments/kits of each system were used. Then, it was registered the number of root canals prepared until the instrument fractured and the number of reinsertions needed until the working length was achieved. Results: The statistical analysis showed significant differences among the durability of the three systems, being the instruments of group PDH the ones that yielded higher reuses (29.2) followed by groups REC (21.6), and TFA (15.4) (P < .05). Regarding the number of insertions, the TFA system was the one that needed the lowest number of reinsertions (P < .05). Conclusion: Under this study conditions, ProDesign Duo Hybrid was the most durable system, whereas TF Adaptive system was the one that most easily achieved the working length.


Asunto(s)
Humanos , Fracturas por Estrés , Instrumentos Dentales , Diente Molar
19.
Braz. oral res. (Online) ; 34: e117, 2020. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1132672

RESUMEN

Abstract The aim of this study was to assess Brazilian endodontists' level of knowledge about the coronavirus disease (COVID-19) and examine its professional repercussions. The link to the online survey that was created for this study was shared with Brazilian endodontists through social networking applications. The questionnaire contained questions that pertained to COVID-19 and its impact on dental practice. The collected data were analyzed using t-test, chi-square analysis, and analysis of variance, and the level of significance was set at 0.05. A total of 2,135 participants responded to the questionnaire, and all five Brazilian regions were represented in the sample. A total of 98.50% of endodontists reported that dental procedures can transmit COVID-19. Complete social distancing was practiced by 96.68% of the participants, and approximately 25% knew someone who had COVID-19. Moreover, in their daily practice, 72.13% of them implemented biosecurity measures that are ineffective in preventing COVID-19. Furthermore, 91.7% of them reportedly suspended elective dental procedures. Only 55.69% of them reported that they performed only emergency procedures in their workplaces. Those who believed that COVID-19 cannot be transmitted during dental procedures were less knowledgeable about the symptoms of COVID-19 (p = 0.0095). Endodontists who believed that personal protective equipment cannot prevent contamination were more knowledgeable about the symptoms of COVID-19 than their counterparts (p = 0.0003). The participating Brazilian endodontists demonstrated adequate knowledge about the risk of contamination during dental procedures and the main symptoms of COVID-19. Only some professionals reported providing emergency dental care during the pandemic.


Asunto(s)
Humanos , Neumonía Viral/epidemiología , Conocimientos, Actitudes y Práctica en Salud , Infecciones por Coronavirus/epidemiología , Endodoncistas , Neumonía Viral/transmisión , Brasil , Encuestas y Cuestionarios , Infecciones por Coronavirus/transmisión , Endodoncia , Pandemias , Betacoronavirus , SARS-CoV-2 , COVID-19
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA