Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38608191

RESUMEN

OBJECTIVE: To compare digital panoramic radiography (DPR) and cone beam computed tomography (CBCT) in the detection and classification of pulp calcifications in posterior teeth in relation to tooth condition and its location. METHODS: 250 patients with simultaneous DPR and CBCT scans were selected from a dental image bank. For each posterior tooth, its condition was registered (healthy, restored, or decayed). The presence of calcifications was assessed and classified according to location (coronal or radicular) and type (total obliteration, partial obliteration, narrowing, and no calcification). Chi-square and McNemar tests were used to compare DPR and CBCT results, with a significance level of 5%. DPR diagnostic values were calculated using CBCT as reference. RESULTS: Decayed and restored teeth showed a significantly (p < 0.001) higher prevalence of pulp calcifications than healthy teeth in both imaging exams. There was a significant discrepancy between the imaging modalities in the identification of calcifications (p < 0.001), especially for radicular calcifications of maxillary teeth (DPR = 55.2%; CBCT = 30.9%). In the case of coronal calcifications, there was a greater discrepancy between CBCT and DPR in the mandibular teeth (10.7%) than in the maxillary teeth (7.7%). Overall, DPR presents higher sensitivity (0.855) than specificity (0.483) for pulp calcifications detection. CONCLUSION: DPR considerably overestimates pulp calcifications in posterior teeth, as compared to CBCT. A higher prevalence of pulp calcifications is related to decayed and restored teeth.

2.
J Endod ; 50(4): 434-449, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38290691

RESUMEN

INTRODUCTION: The development of dedicated coils and new magnetic resonance imaging (MRI) sequences has led to an increase in image resolution and a reduction in artifacts. Consequently, numerous studies have demonstrated the utility of MRI as a nonionizing alternative to cone-beam computed tomographic imaging. The aim of this systematic review was to evaluate the accuracy of MRI in clinical applications in endodontics. METHODS: A literature search was conducted using PubMed, Embase, Scopus, and Web of Science. The inclusion criteria encompassed studies evaluating MRI applications in endodontics, covering tooth and root canal anatomy, root canal working length, pulp vitality and regeneration, the effect of caries on dental pulp, guided endodontics, periapical lesions, and root cracks/fractures. The selected studies examined both ex vivo and in vivo human teeth using clinical MRI units. Two researchers independently screened the studies, applied the eligibility criteria, and assessed the potential risk of bias using the revised QUADAS-2 tool (Bristol Medical School, University of Bristol, UK). RESULTS: A total of 18 studies were included in this systematic review, demonstrating that the use of MRI has a high diagnostic value in endodontics. In the evaluation of tooth and root canal anatomy, pulp vitality and regeneration, the effect of caries on dental pulp, periapical lesions, and root cracks/fractures, MRI's accuracy is comparable to or even higher than reference standards such as cone-beam computed tomographic imaging, micro-computed tomographic imaging, and histology. CONCLUSIONS: MRI has high potential accuracy for diagnosing various clinical endodontic tasks, except for root canal length, size of caries, and periapical lesion dimensions, which are overestimated in MRI.


Asunto(s)
Caries Dental , Endodoncia , Humanos , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/anatomía & histología , Tratamiento del Conducto Radicular/métodos , Endodoncia/métodos , Imagen por Resonancia Magnética , Tomografía Computarizada de Haz Cónico/métodos
3.
Clin Oral Investig ; 27(11): 6413-6420, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37704914

RESUMEN

AIM: To assess the observed volume of filled C-shaped root canals from different CBCT and micro-CT having nano-CT as a reference. MATERIALS AND METHODS: Twelve extracted mandibular molars with C-shaped root canals were endodontically treated using Reciproc Blue R25 (VDW GMBH, Munich, Germany) in a reciprocating system and filled with gutta-percha (Dentsply Maillefer) and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany). CBCT scans were performed using 3 units-3D Accuitomo 170 (J. Morita, Kyoto, Japan), ProMax 3D Max (Planmeca, Helsinki, Finland), and NewTom VGi EVO (Cefla QR, Verona, Italy)-at two resolution modes: standard and high. Micro-CT and nano-CT scans were also obtained. The volume of all filled C-shaped root canals was obtained using CTAn software (Bruker, Kontich, Belgium), and the blooming artifact, in relation to nano-CT volume, was calculated. The data were evaluated by the Bland-Altman plots and ANOVA two-way for repeated measures (α = 0.05). RESULTS: All CBCT units and micro-CT showed significantly larger observed volume of root canal filling when compared to nano-CT. The blooming artifact of root canal filling in standard resolution was significantly larger than that in high resolution (p < 0.05) in all CBCT units. CONCLUSIONS: Endodontic filling material with AH Plus sealer causes blooming artifacts in CBCT units and micro-CT. CLINICAL RELEVANCE: Considering the anatomical complexity of C-shaped root canals and the challenges associated with endodontic treatment, CBCT is frequently recommended for follow-up evaluations. However, the presence of endodontic filling material can result in blooming artifacts that may potentially impact the accurate diagnosis of endodontic complications.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Cavidad Pulpar , Microtomografía por Rayos X , Preparación del Conducto Radicular , Retratamiento , Gutapercha , Obturación del Conducto Radicular , Tomografía Computarizada de Haz Cónico
4.
Artículo en Inglés | MEDLINE | ID: mdl-37580223

RESUMEN

OBJECTIVE: The objective of this study was to evaluate 2-dimensional (2D) and 3D morphometric parameters of C-shaped root canals on cone beam computed tomography (CBCT) and microcomputed tomography (microCT) images using nanocomputed tomography (nanoCT) as the reference standard. STUDY DESIGN: Sixty mandibular molars with C-shaped canals were individually scanned using nanoCT and microCT. Cone beam computed tomography acquisitions were then performed with 4 CBCT systems, using high and standard resolutions. The 2D parameters of roundness and major and minor diameters were obtained in the cross sections of the root canals at 1, 2, and 3 mm from the root apex. The 3D parameters of surface area, volume, and structure model index were measured considering the entire extension of the root canals. Absolute error (AE) in measurement was calculated against the nanoCT values. Data were statistically analyzed with the Shapiro-Wilk test and analysis of variance (α = 0.05). RESULTS: No significant differences in AE were discovered for the 2D parameters among microCT and the CBCT scans. The AE values for the 3D parameters of volume and surface area were significantly smaller in microCT compared to all CBCT units (P < .05). Significantly lower AE values for surface area were observed in high resolution compared to standard resolution for all CBCT units (P < .05). Structure model index did not differ significantly among microCT and all CBCT protocols. CONCLUSIONS: Cone beam computed tomography images showed accuracy for evaluating 2D parameters and over- and underestimation for 3D parameters.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Cavidad Pulpar , Humanos , Cavidad Pulpar/diagnóstico por imagen , Microtomografía por Rayos X , Tomografía Computarizada de Haz Cónico/métodos , Diente Molar/diagnóstico por imagen , Raíz del Diente , Mandíbula/diagnóstico por imagen
5.
J Endod ; 49(9): 1161-1168, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37451335

RESUMEN

INTRODUCTION: Cone-beam computed tomography (CBCT) allows three-dimensional evaluation and has high diagnostic accuracy of endodontic conditions. Considering that the most indicated protocol for endodontics should have smaller field-of-view and higher spatial resolution, a higher radiation dose may be associated. Thus, this study evaluated the accuracy of an optimized CBCT protocol for the detection of intraoperative endodontic complications. METHODS: An image phantom was custom-made with a human mandible covered with Mix-D and forty mandibular first molars. The teeth were subdivided into 4 groups of endodontic complications which were simulated. All teeth were individually inserted into the left second molar socket of the phantom and CBCT images were acquired with OP 300 unit adjusted to a field-of-view of 6 × 4 cm, 90kVp, and 2 dose protocols: low and high. Furthermore, a titanium implant, a tooth with endodontic treatment, and a cobalt-chromium post were inserted into the empty sockets adjacent to the teeth of interest and additional images were acquired. Four endodontists evaluated the images and indicated the presence of endodontic complications on a 5-point scale. Sensitivity, specificity, and area under the receiver operating characteristic curve were obtained. The different groups were compared by ANOVA and Tukey tests (α = 0.05). RESULTS: In most conditions, irrespective of the presence of metallic materials, the values of accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve did not differ significantly (P > .05) between the dose protocols. CONCLUSIONS: Optimized CBCT protocols should be considered for the detection of intraoperative endodontic Diagnostic complications.


Asunto(s)
Endodoncia , Endodoncistas , Humanos , Curva ROC , Tomografía Computarizada de Haz Cónico/métodos , Diente Molar/diagnóstico por imagen
6.
Arch Oral Biol ; 151: 105715, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37146389

RESUMEN

OBJECTIVES: To evaluate the prevalence and morphological characteristics of DI using CBCT. METHODS: A literature search was performed in PubMed, Embase, Scopus, and Web of Science. Inclusion criteria were randomized clinical trials, cross-sectional studies, and prospective and retrospective cohort studies evaluating the morphological characteristics of DI in anterior teeth using CBCT. Three reviewer authors independently screened the studies, applied the eligibility criteria, assessed the risk of bias, and extracted until September (2022). The risk of bias was evaluated using the Joanna Briggs Institute criteria. Meta-analyses of proportions were used for estimate the prevalence DI according to factors at participant and tooth levels. RESULTS: Six studies were included in the meta-analysis. Among 7373 individuals, a prevalence of 7.45 % of DI was observed (n = 258; τ2 = 0.0096; CI of 4.51-11.3; p < 0.05), with no significant influence of sex. Regarding laterality, unilateral DI showed higher mean prevalence (4.30 %; CI of 2.03-7.33). Among the 382 anterior teeth with DI (0.72 %), the most affected tooth was the upper lateral incisor (5.12 %; n = 329; CI of 2.35-8.86; p < 0.001), type I was the most prevalent (0.59 %; CI of 0.24-1.08) and the presence of open apex and periradicular pathology ranged from 4.3 % to 22.72 % and 3.5-77.92 %, respectively. CONCLUSIONS: The prevalence of individuals with dens invaginatus was 7.45 %, the most affect tooth was the upper lateral incisor with a prevalence of 5.12 % unilaterally and type I was the most prevalent morphology.


Asunto(s)
Dens in Dente , Tratamiento del Conducto Radicular , Humanos , Dens in Dente/diagnóstico por imagen , Dens in Dente/epidemiología , Estudios Retrospectivos , Estudios Transversales , Prevalencia , Estudios Prospectivos , Tomografía Computarizada de Haz Cónico
7.
Imaging Sci Dent ; 53(1): 77-82, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37006788

RESUMEN

Purpose: This study evaluated anatomical variations in the root canals of the lower premolars and molars in a Brazilian sub-population using cone-beam computed tomography (CBCT). Materials and Methods: In total, 121 CBCT images of patients were selected from a database. All images contained lower first and second premolars and molars on both sides of the arch, fully developed roots, and no treatment, resorption, or calcifications. In each image, the root canals of the lower premolars and molars were evaluated according to the Vertucci classification in On-Demand 3D software in the multiplanar reconstruction with dynamic navigation. Twenty-five percent of the images were re-assessed to analyze intraobserver confidence with the kappa test. Data were statistically evaluated with linear regression to evaluate the correlations of anatomic variations with age and sex, and the Wilcoxon test to analyze the laterality of variations, with a significance level of 5%. Results: The intraobserver agreement (0.94) was excellent. In general, the root canals of lower premolars and molars showed a higher prevalence of type I than other Vertucci classification types, followed by type V in premolars and type II in molars. When the molar roots were evaluated separately, type II was more frequent in mesial roots and type I in distal roots. Although age showed no correlations with the results, sex and laterality showed correlations with tooth 45 and the lower second premolars, respectively. Conclusion: The lower premolars and molars of a Brazilian sub-population showed a wide range of root canal anatomic variations.

8.
Clin Oral Investig ; 26(8): 5105-5116, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35618962

RESUMEN

AIM: To evaluate the influence of root canal filling quality on periapical lesion status using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: The bibliographic search was conducted in electronic databases of PubMed, Embase, Scopus, and Web of Science without restrictions related to the year of publication and language. Inclusion criteria were prospective or retrospective cohort studies that followed periapical pathosis for, at least, 1 year. Three reviewers independently evaluated the eligibility for inclusion, extracted data, and assessed the risk of bias. The quality of the studies was based on the Newcastle-Ottawa Scale. This meta-analysis was performed to evaluate the quality of treatment by the homogeneity and apical extension of the filling. RESULTS: Of the 1179 studies initially recovered, six cohort studies were included, out of which four were considered with a low risk of bias. The results showed that the absence of gaps in the filling reduced the chance of unhealed periapical lesions by 2.39 times (RR = 2.39; 95% CI: 1.62-3.53; p < 0.00001; I2 = 55%). An apical filling extension of 0-2 mm below the apex also contributed significantly to the absence of unhealed periapical lesions (RR = 1.49; 95% CI: 1.15-1.94; p = 0.003; I2 = 2%). CONCLUSION: The homogeneity and apical extension of the filling influenced the presence of unhealed periapical lesions in endodontically treated teeth evaluated using CBCT. CLINICAL RELEVANCE: Apical extension of the filling ranging between 0 and 2 mm short of the apical foramen and the homogeneity of the filling without gaps are directly related to the success rate of root canal treatment.


Asunto(s)
Cavidad Pulpar , Periodontitis Periapical , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Periodontitis Periapical/terapia , Estudios Prospectivos , Estudios Retrospectivos , Tratamiento del Conducto Radicular/métodos
9.
Dentomaxillofac Radiol ; 50(4): 20200450, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33237809

RESUMEN

OBJECTIVES: To evaluate the influence of exomass-related metal artefacts on the detection of simulated vertical root fracture (VRF) in cone-beam computed tomography (CBCT). METHODS: 20 teeth were endodontically instrumented and VRF was induced in half of them. All teeth were individually placed in an empty socket of a human mandible. Metallic materials were differently arranged in the exomass [zone outside of the field of view (FOV) but between the X-ray source and the receptor] and/or endomass (zone inside of the FOV), and CBCT scans were obtained. Four radiologists evaluated the presence of VRF using a 5-point scale. Sensitivity, specificity, and area under the receiver operating curve (AUC) were compared using ANOVA. Also, the tooth of interest was replaced with a tube filled with a radiopaque solution and all CBCT scans were repeated to analyse the data objectively. Mean grey and noise values were obtained from the tube and compared using ANOVA followed by Tukey's test (α = 0.05). RESULTS: Mean grey values were significantly lower and noise was significantly higher when metallic materials were present in the endomass or both the exomass and endomass. Sensitivity, specificity, and AUC were not influenced by the artefacts from the metallic materials irrespective of the arrangement condition. CONCLUSIONS: Exomass-related metal artefacts did not influence the diagnosis of simulated VRF in CBCT.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Fracturas de los Dientes , Artefactos , Humanos , Metales , Rotación , Fracturas de los Dientes/diagnóstico por imagen , Raíz del Diente/diagnóstico por imagen
10.
Dentomaxillofac Radiol ; 48(3): 20180290, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30540919

RESUMEN

The aim of this study was to evaluate the effectiveness of metal artefact reduction (MAR) in cone beam CT (CBCT) artefacts arising from metallic objects in the exomass. A radiographic phantom composed of 16 polypropylene tubes filled with a homogeneous radiopaque solution was created. CBCT scans were obtained with two units: Picasso Trio (Vatech, South Korea) and ProMax (Planmeca, Finland). The phantom was centred in a 5 × 5 cm field-of-view (FOV) with titanium and CoCr inserts in the exomass. All scans were repeated after enabling MAR. Mean voxel values were obtained from the 16 tubes and standard deviation was calculated as a way of measuring voxel value variability. Mean values and voxel value variability were compared individually in the presence and absence of MAR by means of analysis of variance, followed by Tukey's test (α = 0.05). In the Picasso Trio, MAR significantly decreased mean voxel values (p ≤ 0.05) and increased voxel value variability (p > 0.05) in the presence of titanium. When CoCr was present, no statistical difference (p > 0.05) was observed. In the ProMax, MAR increased significantly mean voxel values (p ≤ 0.05) in the presence of titanium, and presented no significant difference (p > 0.05) for CoCr. Voxel value variability did not differ significantly (p > 0.05) for both materials. In conclusion, MAR was not effective to correct CBCT artefacts arising from metallic objects in the exomass in the two CBCT units used.


Asunto(s)
Algoritmos , Artefactos , Tomografía Computarizada de Haz Cónico , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...