Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 202
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38802889

RESUMEN

OBJECTIVE: To compare collected bone weight and the frequency of autologous bone harvesting from the flutes of surgical drills used for implant bed preparation using two different drilling techniques. A comparative evaluation of radiographic bone density and bone quality was also made. MATERIALS AND METHODS: A randomized clinical trial was made of 66 dental implants in patients with a single posterior edentulous site. The compared drilling techniques were high-speed drilling with irrigation (control group) and low-speed drilling without irrigation (test group). The bone collected in both groups was dried and weighed with a precise electronic balance. The frequency of harvesting was calculated. The median radiographic bone density of each implant site was measured using cone-beam computed tomography (CBCT) pixel values. Patient sex, age, implant position and dimensions, as well as the last drill diameter were analyzed as independent variables. The level of significance was 5%. RESULTS: The harvesting of bone chips from drill flutes proved possible in 51.5% of the procedures in the control group and in 100% in the test group (p < 0.001). There were also statistically significant differences in bone weight between the control group (6.7 ± 10.6 mg) and the test group (41.9 ± 30.3 mg) (p < 0.001). The CBCT pixel values were directly correlated with the collected bone weight in both groups. The median radiographic bone density, arch and last drill diameter were significantly associated with harvesting bone frequency and collected bone weight (p < 0.05). CONCLUSIONS: Our findings suggest that the frequency and weight of autologous bone harvested from drills are greater with low-speed drilling without irrigation than with high-speed drilling with irrigation. Radiographic bone density, arch and last drill diameter also significantly influenced the harvesting outcomes.

2.
Clin Oral Investig ; 28(5): 300, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38704784

RESUMEN

OBJECTIVE: The primary objective of this review is to compare autogenous soft tissue grafts (connective tissue graft - CTG and free gingival graft-FGG) with different type of matrices (acellular dermal matrix-ADM, xenograft collagen matrix-XCM, volume-stable collagen matrix-VCMX) used to increase peri-implant soft tissues. MATERIALS AND METHODS: A search on electronic databases was performed to identify randomized and non-randomized controlled trials (RCTs and CCTs, respectively) with either parallel or split-mouth design, and treating ≥ 10 patients. A network meta-analysis (NMA) was used to compare different matrices. Soft tissue thickness dimensional changes and keratinized width (KMW) changes were the primary outcome measures. The secondary outcomes were to evaluate: a) PROMs; b) volumetric changes; c) surgical operating time; and d) different periodontal measurements. RESULTS: A total of 23 studies were included in the qualitative analysis, and 16 studies (11 RCTs and 5 CCTs) in the quantitative analysis. A total of N = 573 sites were evaluated for NMA. CTG resulted the best material for increasing peri-implant soft tissue thickness, at 180 and 360 days after surgery. The use of an ADM showed good results for buccal thickness increase, primarily in the first three months after surgery. Vestibuloplasty + FGG resulted in the most effective technique for peri-implant KMW augmentation, after 180 days. CONCLUSIONS: While CTG demonstrated better performance in all the comparison and FGG showed to be the best graft to increase keratinized mucosa up to 90 days, ADM and VCMX may be used to increase soft tissue horizontal thickness with lower patients' morbidity. LIMITATIONS: The limits of this NMA are the following: a) limited number of included studies; b) high heterogeneity among them (number of patients, treatment sites, surgical techniques, outcome measures, and follow-ups). CLINICAL RELEVANCE: Many studies compared the efficacy of autogenous and non-autogenous grafts in terms of gingival thickness, volume, and keratinized width increase. However, there is still not clear overall evidence on this topic. This NMA helps clinicians to choose the right material in different peri-implant soft tissue procedures. Recommendations for future studies are mandatory.


Asunto(s)
Colágeno , Metaanálisis en Red , Humanos , Colágeno/uso terapéutico , Encía/trasplante , Dermis Acelular , Tejido Conectivo/trasplante , Implantes Dentales , Gingivoplastia/métodos
3.
Dent J (Basel) ; 12(4)2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38668023

RESUMEN

BACKGROUND: Restorative materials might significantly affect load transmission in peri-implant bone. The aim of the present study is to evaluate the shock absorption capacity of two different polymeric materials to be used for implant-supported prostheses. METHODS: A masticatory robot was used to compare the shock absorption capacity of veneered and non-veneered polyetherketoneketone (PEKK), Pekkton®ivory (Cendres+Mètaux), and the glass fiber-reinforced composite (GFRC), TRINIATM (Bicon). Five identical sample crowns for each of the three groups were tested. Forces transmitted at the simulated peri-implant bone were recorded and statistically analyzed. RESULTS: The statistical analysis of forces transmitted at the simulated dental implant revealed significant differences between the materials tested and between these materials and zirconia, glass ceramic, composite resin, and acrylic resin. Only differences between PEKK and veneered PEKK and between PEKK and one of the previously tested composite resins were not statistically significant. PEKK samples demonstrated significantly greater shock absorption capacity compared to GFRC. CONCLUSIONS: PEKK revealed optimal shock absorption capacity. Further studies are needed to evaluate its efficacy in the case of long-span prostheses with reduced prosthetic volume.

4.
J Clin Med ; 13(7)2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38610826

RESUMEN

Background: Fiber-reinforced composites (FRCs) have been proposed as an alternative to traditional metal alloys for the realization of frameworks in full-arch implant-supported prostheses. The aim of the present in vitro study was to evaluate the deflection under load of seven prostheses endowed with frameworks made of different materials, including different types of fiber-reinforced composites (FRCs). Methods: A master cast with four implant analogues in correspondence with the two lateral incisors and the two first molars was used to create full-arch fixed prostheses with the same shape and different materials. Prostheses were made of the following different materials (framework+veneering material): gold alloy+resin (Au+R), titanium+resin (Ti+R), FRC with multidirectional carbon fibers+resin (ICFRC+AR), FRC with unidirectional carbon fibers+composite (UCFRC+C), FRC with glass fibers+resin (GFRC+AR), FRC with glass fibers+composite (GFRC+C), and resin (R, fully acrylic prosthesis). Flexural tests were conducted using a Zwick/Roell Z 0.5 machine, and the deflection of the lower surface of the prosthesis was measured in order to obtain load/deflection graphs. Results: Greater rigidity and less deflection were recorded for UCFRC+C and GFRC+C, followed by Ti+R and Au+R. The greatest deformations were observed for resin alone, ICFRC+R, and GFRC+R. The results were slightly different in the incisal region, probably due to the greater amount of veneering material in this area. Conclusions: When used to realize full-arch frameworks, Au and Ti allow for predictable mechanical behavior with gradual deformations with increasing load. UCFRC also demonstrated good outcomes and less deflection than ICFRCs when loaded. The GFRC full-arch framework may be a valid alternative, although it showed greater deflections. Further studies are needed in order to evaluate how different prosthesis designs and material thicknesses might affect the outcomes.

5.
Dent J (Basel) ; 12(3)2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38534295

RESUMEN

This study was conducted to compare the effects of an innovative plasma surface treatment device that does not need a gas supply for titanium disks with two different surface topographies: the prototypical machined surface (MAC) and one of the most diffused roughened ones (SL) obtained through grit blasting and acid etching. A total of 200-MAC and 200-SL titanium disks were used. Each group of disks was divided into four sub-groups of 40 samples each that were subjected to five different tests. Among these, 150-MAC and 150-SL were considered the test group, and they were treated with plasma for 15, 30, and 60 s after being removed from the sterile packaging. On the other hand, 50-MAC and 50-SL were considered the control group, and they were only removed from sterile plastic vials. The samples were analyzed to evaluate the capability of the plasma treatment in influencing protein adsorption, cell adhesion, proliferation, and microbial growth on the test group disks when compared to the untreated disks. Protein adsorption was significantly enhanced after 20 min of plasma treatment for 15 and 30 s on the MAC and SL disks. Plasma treatment for 15 and 30 s significantly increased the level of adhesion in both treated samples after 30 min. Furthermore, the MAC samples showed a significant increase in cell adhesion 4 h after plasma treatment for 15 s. The SEM analysis highlighted that, on the treated samples (especially on the MAC disks), the cells with a polygonal and flat shape prevailed, while the fusiform- and globular-shaped cells were rare. The encouraging results obtained further confirm the effectiveness of plasma treatments on cell adhesion and fibroblast activity.

6.
J Dent ; 145: 104979, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38556193

RESUMEN

OBJECTIVES: The aim of the present in vitro study was to evaluate the effect of a novel auxiliary geometric device (AGD) on the accuracy of full-arch scans captured with 3 different intraoral scanners (IOS). METHODS: An edentulous maxillary model with four internal connection implant replicas was scanned using 3 different IOS: iTero Element 5D (ITERO) (Align Technology, Tempe, AZ, USA), Trios 4 (TRIOS) (3Shape A/S, Copenhagen, Denmark), and Carestream 3700 (CS) (Carestream Dental, Atlanta, USA). Thirty-six scans were taken with each IOS, 18 with the AGD in place, and 18 without the AGD. A digital master model was created using an industrial optical scanner (ATOS compact Scan 5M, GOM GmbH, Braunschweig, Germany). The master and IOS models were aligned using the scan bodies as a reference area. A surface comparison was performed, and deviation labels were exported for each scan body to evaluate the linear and angular deviation. Total body, platform and angular deviations were measured. RESULTS: The use of AGD resulted in a statistically significant increase of angular deviation: 0.87° (SD=0.21) in the AGD group versus 0.64° (SD=0.46) in the no AGD group (p-value=0.005). The difference between the AGD and no AGD groups was not statistically significant for total body and platform deviation values (p-value=0.051 and 0.302 respectively). Using AGD, ITERO showed a statistically significant increase in angular deviation (mean difference=-0.46 µm, p-value=0.002) and a decrease in mean platform deviation (mean difference=63.19 µm, p-value<0.001). No statistically significant differences were found for the other IOS. CONCLUSIONS: The use of AGD did not add benefit on CS and TRIOS. On ITERO, there was an improvement in platform deviation, that was outweighed by the worsening of the angular deviation. CLINICAL SIGNIFICANCE: In vitro data suggest that intraoral scans can be successfully used in full-arch cases. The use of AGD has no additional benefit on CS and TRIOS. On ITERO there was an improvement in platform deviation that was outweighed by the worsening of the angular deviation. Translational application to clinical practice deserves further investigation, taking into account patient-related and anatomical variables.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Modelos Dentales , Humanos , Maxilar/diagnóstico por imagen , Diseño Asistido por Computadora , Imagenología Tridimensional/métodos , Arcada Edéntula/diagnóstico por imagen , Arcada Edéntula/rehabilitación , Técnicas In Vitro , Arco Dental/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Diseño de Prótesis Dental
7.
Clin Implant Dent Relat Res ; 26(1): 226-236, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37853303

RESUMEN

OBJECTIVE: To assess the peri-implant soft tissue profiles between argon plasma treatment (PT) and non-treated (NPT) healing abutments by comparing clinical and histological parameters 2 months following abutment placement. MATERIALS AND METHODS: Thirty participants were randomly assigned to argon-plasma treatment abutments group (PT) or non-treated abutments (NPT) group. Two months after healing abutment placement, soft peri-implant tissues and abutment were harvested, and histological and clinical parameters including plaque index, bleeding on probing, and keratinized mucosa diameter (KM) were assessed. Specialized stainings (hematoxylin-eosin and picrocirious red) coupled with immunohistochemistry (vimentin, collagen, and CK10) were performed to assess soft tissue inflammation and healing, and the collagen content keratinization. In addition to standard statistical methods, machine learning algorithms were applied for advanced soft tissue profiling between the test and control groups. RESULTS: PT group showed lower plaque accumulation and inflammation grade (6.71% vs. 13.25%, respectively; p-value 0.02), and more advanced connective tissue healing and integration compared to NPT (31.77% vs. 23.3%, respectively; p = 0.009). In the control group, more expressed keratinization was found compared to the PT group, showing significantly higher CK10 (>47.5%). No differences in KM were found between the groups. SIGNIFICANCE: PT seems to be a promising protocol for guided peri-implant soft tissue morphogenesis reducing plaque accumulation and inflammation, and stimulating collagen and soft tissue but without effects on epithelial tissues and keratinization.


Asunto(s)
Implantes Dentales , Placa Dental , Gases em Plasma , Diente , Humanos , Argón , Colágeno , Inflamación , Pilares Dentales , Titanio
8.
Dent Mater ; 40(1): 28-36, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37865576

RESUMEN

OBJECTIVES: VEGF is prototypic marker of neovascularization, repeatedly proposed as intrinsic characteristic of peri-implantitis. This study aimed to assess pattern of VEGF in peri-implantitis, its correlation with titanium particles (TPs) and capacity as respective biomarker. MATERIAL AND METHODS: Pathological specificity of VEGF was assessed in peri-implant granulations using immunohistochemistry, periodontal granulations represented Ti-free positive controls. VEGF was correlated to TPs, identified using scanning electron microscopy coupled with dispersive x-ray spectrometry. Diagnostic accuracy, sensitivity and specificity of VEGF were estimated in PICF specimens from peri-implantitis, peri-implant mucositis (PIM) and healthy peri-implant tissues (HI) using machine learning algorithms. RESULTS: Peri-implantitis exhibited rich neovascular network with expressed density in contact zones toward neutrophil infiltrates without specific pattern variations around TPs, identified in all peri-implantitis specimens (mean particle size 8.9 ± 24.8 µm2; Ti-mass (%) 0.380 ± 0.163). VEGF was significantly more expressed in peri-implantitis (47,065 ± 24.2) compared to periodontitis (31,14 ± 9.15), and positively correlated with its soluble concentrations in PICF (p = 0.01). VEGF was positively correlated to all clinical endpoints and significantly increased in peri-implantitis compared to both PIM and HI, but despite high specificity (96%), its overall diagnostic capacity was average. Two patient clusters were identified in peri-implantitis, one with 8-fold higher VEGF values compared to HI, and second with lower values comparable to PIM. SIGNIFICANCE: VEGF accurately reflects neovascularization in peri-implantitis that was expressed in contact zones toward implant surface without specific histopathological patter variation around TPs. VEGF answered requests for biomarker of peri-implantitis but further research is necessary to decrypt its exact underlying cause.


Asunto(s)
Implantes Dentales , Periimplantitis , Humanos , Periimplantitis/diagnóstico , Titanio , Factor A de Crecimiento Endotelial Vascular , Biomarcadores
9.
Int J Oral Maxillofac Implants ; 38(5): 923-932, 2023 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-37847834

RESUMEN

PURPOSE: To compare bone substitutes composed of glycated collagen with synthetic micro-sized (1 to 10 µm) hydroxyapatite (OB) vs non-cross-linked collagen matrix with large-particle (250 to 1,000 µm) bovine-derived hydroxyapatite (BOC). MATERIALS AND METHODS: The P1 to P4 premolars were bilaterally extracted from the mandibles of 19 Beagle dogs. After 21 days, osteotomies were created in each dog that received OB or BOC and were covered with a collagen membrane or were left untreated. The animals were randomly divided into three groups based on sacrifice time (4, 12, or 24 weeks). The right and left hemimandibles were trimmed to facilitate imaging and histology, and all tissues were placed in 10% neutral-buffered formalin. Microcomputed tomography (MicroCT 40 Scanner, Scanco) was used to analyze bone sections. Bone volume, residual material volume, and bone mineral density were determined for each treatment site (OB and BOC) based on a volume of interest that encompassed the original defect. Additionally, blinded histopathologic assessment (based on the ISO 10993-6 scoring system) and histomorphometry were performed on sections ground to < 100 µm thick and stained with Stevenel's blue. RESULTS: No clinical side effects were noted. No statistical differences were observed for OB vs BOC regarding the mineral volume percentage. Compared to OB, BOC had significantly higher mean mineralization densities at 12 weeks (P < .01), but this difference did not extend to 24 weeks. For residual grafting material, bone maturation, alveolar ridge restoration, and inflammatory response, OB showed a residual amount of bone graft and no statistical differences compared to BOC. CONCLUSION: Both OB and BOC represent valid treatment options for critically sized bone defects. Both bone fillers outperformed the sham-operated, ungrafted (empty) control, demonstrating statistically improved bone growth and ridge restoration.


Asunto(s)
Aumento de la Cresta Alveolar , Sustitutos de Huesos , Perros , Animales , Bovinos , Durapatita/uso terapéutico , Osteogénesis , Microtomografía por Rayos X , Regeneración Tisular Guiada Periodontal/métodos , Regeneración Ósea/fisiología , Sustitutos de Huesos/uso terapéutico , Colágeno/uso terapéutico , Aumento de la Cresta Alveolar/métodos
10.
Int J Oral Maxillofac Implants ; 38(4): 801-810, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37669520

RESUMEN

Purpose: To compare glycated multilayered membranes (OV) to a commercially available thin-layer membrane (OP) in a lateral ridge augmentation model in dogs. Materials and Methods: This was designed as a three-arm study, where one negative control (empty defect) was compared to two test arms: alveolar bone defects grafted with a mixture of 90% deproteinized bovine bone mineral and 10% porcine collagen, then covered with either a thick- (OV) or thin-layered (OP) membrane. Animals were randomly divided into three groups corresponding to the final sacrifice times of 4 weeks, 12 weeks, and 24 weeks. Sections underwent microCT, histology, histopathology, and histomorphometry. Results: No statistical differences were observed for OV compared to OP regarding the percentage of mineral volume and mean mineral density, amount of bone maturation, percentage of bone graft and membrane remaining in the grafted area, alveolar ridge width measurements, membrane mineralization, or ossification. Test groups presented significantly higher values compared to the empty control for all the endpoints. Conclusions: Within its limitations, this in vivo study highlighted that multilayered thick glycated membranes can serve as effective occlusive barriers for up to 6 months.


Asunto(s)
Aumento de la Cresta Alveolar , Sustitutos de Huesos , Animales , Bovinos , Perros , Aumento de la Cresta Alveolar/métodos , Regeneración Ósea , Colágeno , Regeneración Tisular Guiada Periodontal , Membranas Artificiales , Minerales , Osteogénesis , Porcinos , Distribución Aleatoria
11.
Bioelectromagnetics ; 44(7-8): 144-155, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37655846

RESUMEN

Pulsed electromagnetic field (PEMF) therapy modulates the immune response and is successfully used in orthopedics to treat osteoarthritis and improve bone regeneration. This may suggest that this treatment may consequently reduce peri-implant soft tissue inflammation and marginal bone loss. To compare clinical, radiographic, and immunological results following nonsurgical treatment for peri-implantitis with or without PEMF therapy. Patients with peri-implantitis were included: pocket probing depth (PPD) between 6 and 8 mm with bleeding on probing (BOP); crestal bone loss between 3 and 5 mm. A novel healing abutment that contained active (test) or inactive (control) PEMF was connected. PEMF was administered via the abutment at exposure ratio of 1/500-1/5000, intensity: 0.05-0.5 mT, frequency: 10-50 kHz for 30 days. Nonsurgical mechanical implant surface debridement was performed. Patients were examined at baseline, 1 and 3 months. Clinical assessment included: plaque index, BOP, PPD, recession, and bone crest level which was radiography measured. Samples of peri-implant crevicular fluid were taken to analyze interleukin-1ß (IL-1ß). Twenty-three patients (34 implants; 19 control, 15 test) were included. At the follow-up, mean crestal bone loss was lower in the test group at 1 and 3 months (2.48 mm vs. 3.73 mm, p < 0.05 and 2.39 vs. 3.37, p < 0.01). IL-1ß levels were also lower in the test group at 2 weeks (72.86 pg/mL vs. 111.7, p < 0.05). Within all the limitation of this preliminary study, the test group improved clinical parameters after a short-term period compared to the control group.


Asunto(s)
Periimplantitis , Humanos , Campos Electromagnéticos , Inflamación , Periimplantitis/tratamiento farmacológico , Proyectos Piloto , Estudios Prospectivos , Método Doble Ciego
12.
J Dent ; 137: 104622, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37453655

RESUMEN

OBJECTIVES: The present study aimed to investigate the trueness and precision of an intraoral transfer element (IOTE) designed for matching intraoral and facial scans. METHODS: A mannequin head with a maxillary model in position was used. Cone beam computed tomography (CBCT) was used to construct the master model (MM). A digital impression of the maxillary arch was taken using an intraoral scanner, and the IOTE was used to record the maxillary arch position. Twenty facial scans with and twenty without the IOTE in place were performed with a handheld device (Ipad Pro, Apple) using a dedicated software. Digital mounting was performed to build a scan model (SM). Using software for data processing, the three-dimensional deviation between the MM and SM at the central left incisor (#9#), and the left and right first molars (#3#, #14#) was calculated as trueness and linear deviation precision. . Angular deviation was also calculated at the occlusal plane. RESULTS: The linear deviation trueness at #9#, #3# and #14# was 0.3 ± 0.12 mm, 1.07 ± 0.28 mm, and 0.18 ± 0.34 mm, respectively, whereas the precision was 1.17 ± 0.4 mm, 0.43 ± 0.12 mm, and 0.64 ± 0.28 mm, respectively. Trueness of the angular deviation at the occlusal plane was 2.17 ± 0.46°, whereas the angular deviation precision was 0.64 ± 0.28°. CONCLUSIONS: Based on in vitro findings the proposed IOTE design is accurate and suitable for clinical use. CLINICAL SIGNIFICANCE: Direct virtual mounting is a reliable technique in vitro; however, in vivo tests are required.


Asunto(s)
Técnica de Impresión Dental , Imagenología Tridimensional , Humanos , Modelos Dentales , Diseño Asistido por Computadora , Maxilar/diagnóstico por imagen
13.
Clin Implant Dent Relat Res ; 25(5): 974-983, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37288709

RESUMEN

BACKGROUND: Different biomaterials were suggested for sinus floor augmentation (SFA). Recently, new materials were launched showing true bone formation without remnants. PURPOSE: The aim of this prospective study was to evaluate an hydroxyapatite-based, sugar cross-linked collagen sponge (OSSIX™ Bone) in transcrestal SFA (t-SFA). MATERIALS AND METHODS: Twenty-four patients with edentulous posterior maxilla and residual bone height (RBH) >4 mm underwent t-SFA with OSSIX™ Bone as grafting material and simultaneous implant placement. The implant Stability Quotient (ISQ) was measured by resonance frequency analysis (RFA) directly after implant insertion and at 6 months. Differences in bone height (BH) and volume were determined in CBCT and x-rays at baseline versus 1 year of follow-up. Graft volume was evaluated by tridimensional reconstructions. Linear regression analysis was used to evaluate the effect of bucco-palatal sinus dimension, RBH, and length of the implant protruding (PIL) into the sinus, on the graft height (GH) changes up to 1 year, and on the graft volume at 1 year. Autocorrelation between time lag and augmented bone volume was evaluated through time series analysis correlograms. Health-related quality-of-life outcomes were captured. RESULTS: Twenty-two patients completed the study. The mean RBH measured at baseline was 5.81 ± 2.2 mm. The mean graft volume was 1085.8 ± 733.4 mm3 . The mean GH, measured in the immediate post-operative period, at 6 and 12 months respectively, was 7.24 mm ±1.94; 6.57 mm ± 2.30; 5.46 mm ± 2.04. The mean ISQ measured after the implant placement was 62.19 ± 8.09, and 6 months later was 76.91 ± 4.50. There was a significant correlation between buccolingual dimension and graft volume at 1 year. Neither buccolingual volume nor RBH had a significant effect on GH change, while the PIL showed a significant positive correlation (P = 0.02 and P = 0.03 at 6 and 12 months, respectively). The correlograms indicated no significant correlation, meaning that there is no tendency for graft volume to increase or decrease over time, therefore suggesting graft stability, at least up to one year of follow-up. 86% of patients had no chewing interference. CONCLUSION: Within the limitations of the study, OSSIX™ Bone could be considered a valid material for SFA due to its manageability and its positive results in promoting new bone formation with long-term stability. T-SFA is confirmed as a less invasive and less painful method.


Asunto(s)
Implantes Dentales , Elevación del Piso del Seno Maxilar , Humanos , Elevación del Piso del Seno Maxilar/métodos , Implantación Dental Endoósea/métodos , Proyectos Piloto , Estudios Prospectivos , Durapatita/uso terapéutico , Seno Maxilar/cirugía , Maxilar/cirugía
14.
Clin Oral Implants Res ; 34(9): 920-933, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37345230

RESUMEN

OBJECTIVES: The aim of the present human observational study is to provide morphologic and morphometric analysis of peri-implant connective tissue next to abutments with divergent or convergent macro-geometry and different surface micro-characteristics. MATERIALS AND METHODS: Thirty patients were rehabilitated with single implants in the posterior area and one out of three different healing abutments with a one-stage technique: machined divergent abutment (DIV-MAC), machined convergent abutment (CONV-MAC) or convergent abutment with ultrathin threaded surface (CONV-UTM). At 3 months postimplant insertion, peri-implant soft tissue was harvested; the following outcomes were investigated: histomorphometry (vertical width of connective and epithelial components) as detected by histology and polarized light; and connective tissue vertical width and 3D organization as detected by synchrotron-based high-resolution phase-contrast-based tomography (PhC-µCT). RESULTS: Significant differences in connective tissue vertical dimension (aJE-AM) were found between DIV-MAC and both CONV-MAC and CONV-UTM, both by histology and PhC-µCT, with significantly higher values for the last two groups. Moreover, 2D histological analysis did not find significant differences in the junctional epithelium vertical dimension (PM-aJE). Importantly, PhC-µCT analysis revealed, at 3D level, significant greater amount and density of collagen bundles for CONV-UTM compared with the other two groups. CONCLUSIONS: Convergent abutment profiles, regardless of their surface micro-geometry, seem to favor axial development of peri-implant connective tissue. Moreover, ultrathin threaded surfaces seem associated with denser and greater connective tissue organization, which might improve peri-implant soft tissue seal.


Asunto(s)
Implantes Dentales , Diente , Humanos , Tejido Conectivo/patología , Colágeno , Inserción Epitelial , Pilares Dentales , Titanio
15.
Materials (Basel) ; 16(10)2023 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-37241340

RESUMEN

The choice of the proper restorative material is essential for the long-term success of implant-supported rehabilitations. This study aimed to analyze and compare the mechanical properties of four different types of commercial abutment materials for implant-supported restorations. These materials included: lithium disilicate (A), translucent zirconia (B), fiber-reinforced polymethyl methacrylate (PMMA) (C), and ceramic-reinforced polyether ether ketone (PEEK) (D). Tests were carried out under combined bending-compression conditions, which involved applying a compressive force tilted with respect to the abutment axis. Static and fatigue tests were performed on two different geometries for each material, and the results were analyzed according to ISO standard 14801:2016. Monotonic loads were applied to measure static strength, whereas alternating loads with a frequency of 10 Hz and a runout of 5 × 106 cycles were applied for fatigue life estimation, corresponding to five years of clinical service. Fatigue tests were carried out with a load ratio of 0.1 and at least four load levels for each material, and the peak value of the load levels was reduced accordingly in subsequent levels. The results showed that the static and fatigue strengths of Type A and Type B materials were better than those of Type C and Type D. Moreover, the fiber-reinforced polymer material, Type C, showed marked material-geometry coupling. The study revealed that the final properties of the restoration depended on manufacturing techniques and the operator's experience. The findings of this study can be used to inform clinicians' choice of restorative materials for implant-supported rehabilitation, considering factors such as esthetics, mechanical properties, and cost.

16.
J Prosthodont Res ; 67(4): 506-517, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37081626

RESUMEN

PURPOSE: This systematic review aimed to evaluate the effect of the abutment material on peri-implant soft tissue health and stability. STUDY SELECTION: An electronic and hand search was conducted until February 2022. Only prospective randomized trials (RCTs) and controlled clinical trials (CCTs) comparing titanium abutments with abutments made of different materials, with a follow-up of at least 6 months, were selected by two independent reviewers. Data on marginal bone loss (MBL) and peri-implant tissue indexes, i.e., plaque index (PI), bleeding on probing (BOP), probing depth (PD), and recession (REC), were collected. The risk of bias for RCTs and non-RCTs was evaluated according to the tool reported in the Cochrane Handbook for Systematic Reviews of Interventions and the ROBINS-I tool, respectively. Both pairwise and network meta-analyses (NMA) were performed. RESULTS: We included 18 relevant studies from 1,437 identified studies. Overall, 612 patients were treated, and 848 abutments were inserted. Five studies presented a low risk of bias. Pairwise meta-analysis showed that, as compared to titanium, zirconia abutments presented a significantly reduced MBL (0.20 mm, 95% Confidence Interval CI [0.14-0.26], P < 0.00001). No significant differences were found for the other outcomes. In the NMA, zirconia abutments demonstrated an 83.3% probability of achieving the highest rank in PI, an 87.0% in BOP, and a 65.0% in PD outcome, suggesting that zirconia abutments generally performed better than titanium and alumina abutments. CONCLUSIONS: Within the limits of the present study, zirconia abutments seem a viable alternative to titanium ones.

17.
BMC Oral Health ; 23(1): 235, 2023 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-37085829

RESUMEN

OBJECTIVE: The aim of the present systematic review was to test the hypothesis that the diameter of implants inserted in the posterior area affects implant survival rate, prosthetic survival rate and peri-implant parameters (bleeding on probing (BoP), marginal bone loss (MBL), pocket probing depth (PPD)). MATERIALS AND METHODS: An electronic search of studies published until December 2021 was done on three databases (Pubmed, Scopus, Cochrane) independently by two authors. Clinical trials comparing implant survival rate, BoP, MBL and PPD among narrow diameter implants (NDI: ≥ 3.0 mm to < 3.75 mm) and regular diameter implants (RDI ≥ 3.75 mm to < 5 mm) were included. Data were independently extracted by two reviewers. Risk of bias was evaluated according to the Cochrane risk-of-bias tool for randomized studies and to the Joanna Briggs Institute Critical Appraisal tools for non-randomized ones. A pair-wise meta-analysis was conducted on the included studies. RESULTS: Seven articles were included out of the 4291 identified from the digital research. Overall, a total of 939 implants were inserted (319 NDI, 620 RDI). Only one study was judged at serious risk of bias. No statistically significant difference was found in implant survival rate (risk ratio 1.01 (95% CI [0.98 to 1.04], P = 0.67)) while the difference was significant for BoP (mean difference 2.89 (95% CI [0.30 to 5.48] mm, P = 0.03)) with higher values for NDI. Higher MBL was identified among regular diameter implants (mean difference -0.15 mm (95% CI [-0.32 to 0.01 mm], P = 0.07). No statistically significant differences were identified for prosthetic survival and PPD. CONCLUSIONS: No differences were found in implant survival rate between narrow and regular implants. A higher BoP was identified among narrow implants, but there was no higher bone loss. It is not possible to draw definitive conclusions about the use of narrow-diameter implants in the posterior region.


Asunto(s)
Pérdida de Hueso Alveolar , Implantes Dentales , Humanos , Tasa de Supervivencia , Implantación Dental Endoósea , Bases de Datos Factuales
18.
Clin Oral Implants Res ; 34(5): 405-415, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36737243

RESUMEN

OBJECTIVES: The aim of the present review and meta-analysis was to evaluate the influence of soft tissue thickness on initial bone remodeling after implant installation. MATERIALS AND METHODS: A literature search was conducted by two independent reviewers on electronic databases up to May 2022. Randomized controlled trials (RCTs) and controlled clinical trials (CCTs) performed on human subjects were included. The risk of bias was evaluated using Cochrane Collaboration's tool. Meta-analysis and Trial Sequential Analysis (TSA) were performed on the selected articles. The primary outcome was marginal bone loss. RESULTS: After screening, 6 studies were included in the final analysis, with a total of 354 implants, and a follow-up from 10 to 14 months. 194 implants were placed in a ≥ 2 mm soft tissue thickness, while 160 had <2 mm soft tissue thickness before implant placement. The included studies had a high level of heterogeneity (I2  > 50%). The meta-analysis indicated a statistically significant difference between the two groups (0.54; p = .027) and the TSA analysis confirmed the results, despite the limited number of dental implants. Additional analysis showed that age and follow-up parameters were not statistically significant factors influencing the bone loss (p = .22 and p = .16, respectively). CONCLUSIONS: Based on the available RCTS and CCTs, initial soft tissue thickness seems to influence marginal bone loss after a short follow-up period. Based on TSA analysis, further studies are needed to assess the influence of the soft tissue thickness on marginal bone loss. PROSPERO registration number: CRD42021235324.


Asunto(s)
Enfermedades Óseas Metabólicas , Implantes Dentales , Humanos , Implantación Dental Endoósea/métodos , Bases de Datos Factuales , Ensayos Clínicos Controlados Aleatorios como Asunto
19.
Int J Mol Sci ; 24(4)2023 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-36834613

RESUMEN

The aim of the present systematic review is to summarize current knowledge regarding the analysis of biomarkers extracted from peri-implant crevicular fluid (PICF) as predictors of peri-implant bone loss (BL). An electronic search was conducted on three databases, PubMed/MEDLINE, Cochrane Library, and Google Scholar, to find clinical trials published until 1 December 2022 suitable to answer the following focused question: in patients with dental implants, are biomarkers harvested from PICF predictive of peri-implant BL? The initial search yielded a total of 158 entries. After a full-text review and application of the eligibility criteria, the final selection consisted of nine articles. The risk of bias in included studies was assessed using the Joanna Briggs Institute Critical Appraisal tools (JBI). According to the present systematic review, some inflammatory biomarkers harvested from PICF (collagenase-2, collagenase-3, ALP, EA, gelatinase b, NTx, procalcitonin, IL-1ß, and several miRNAs) seem to be correlated with peri-implant BL and may assist in the early diagnosis of pathological BL, that characterizes peri-implantitis. MiRNA expression demonstrated a predictive potential of peri-implant BL that could be useful for host-targeted preventive and therapeutic purposes. PICF sampling may represent a promising, noninvasive, and repeatable form of liquid biopsy in implant dentistry.


Asunto(s)
Implantes Dentales , MicroARNs , Periimplantitis , Humanos , Líquido del Surco Gingival/metabolismo , Biomarcadores/análisis , Periimplantitis/diagnóstico , Metaloproteinasa 8 de la Matriz
20.
BMC Oral Health ; 23(1): 27, 2023 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-36650477

RESUMEN

PURPOSE: Biofilm-free implant surface is ultimate prerequisite for successful soft and bone tissue integration. Objective of the study was to estimate the effects of argon plasma healing abutment pre-treatment (PT) on peri-implant soft-tissue phenotype (PiSP), inflammation, plaque accumulation and the microbiome (PiM) between non-treated (NPT) and treated (PT) abutments following 3-months healing period. The hypothesis was that cell-conductive and antimicrobial properties of PT would yield optimal conditions for soft tissue integration. MATERIAL AND METHODS: Two months following second-phase surgery, microbiological and clinical parameters were assessed around thirty-six healing abutments with two types of microtopography, smooth surface (MACHINED) and ultrathin threaded microsurface (ROUGH). A two level randomization schema was used to achieve equal distribution and abutments were randomly divided into rough and machined groups, and then divided into PT and NPT groups. PiM was assessed using next-generation DNA sequencing. RESULTS: PiM bacterial composition was highly diverse already two months post-implantation, consisting of key-stone pathogens, early and late colonizers, while the mycobiome was less diverse. PT was associated with lower plaque accumulation and inflammation without significant impact on PiSP, while in NPT clinical parameters were increased and associated with periopathogens. NPT mostly harbored late colonizers, while PT exerted higher abundance of early colonizers suggesting less advanced plaque formation. Interaction analysis in PT demonstrated S. mitis co-occurrence with pro-healthy Rothia dentocariosa and co-exclusion with Parvimonas micra, Porphyromonas endodontalis and Prevotella oris. PiSP parameters were generally similar between the groups, but significant association between PiM and keratinized mucosa width was observed in both groups, with remarkably more expressed diversity in NPT compared to PT. PT resulted in significantly lower BOP and PI around rough and machined abutments, respectively, without specific effect on PiM and PiSP. CONCLUSIONS: PT contributed to significantly the less advanced biofilm accumulation and inflammation without specific effects on PiSP.


Asunto(s)
Implantes Dentales , Placa Dental , Microbiota , Gases em Plasma , Humanos , Argón , Implantación Dental Endoósea , Diseño de Prótesis Dental , Inflamación , Titanio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...