Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
1.
Phys Imaging Radiat Oncol ; 30: 100573, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38585371

RESUMEN

Background and purpose: Magnetic Resonance Imaging (MRI)-guided Stereotactic body radiotherapy (SBRT) treatment to prostate bed after radical prostatectomy has garnered growing interests. The aim of this study is to evaluate intra-fractional anatomic and dose/volume metric variations for patients receiving this treatment. Materials and methods: Nineteen patients who received 30-34 Gy in 5 fractions on a 0.35T MR-Linac were included. Pre- and post-treatment MRIs were acquired for each fraction (total of 75 fractions). The Clinical Target Volume (CTV), bladder, rectum, and rectal wall were contoured on all images. Volumetric changes, Hausdorff distance, Mean Distance to Agreement (MDA), and Dice similarity coefficient (DSC) for each structure were calculated. Median value and Interquartile range (IQR) were recorded. Changes in target coverage and Organ at Risk (OAR) constraints were compared and evaluated using Wilcoxon rank sum tests at a significant level of 0.05. Results: Bladder had the largest volumetric changes, with a median volume increase of 48.9 % (IQR 28.9-76.8 %) and a median MDA of 5.1 mm (IQR 3.4-7.1 mm). Intra-fractional CTV volume remained stable with a median volume change of 1.2 % (0.0-4.8 %). DSC was 0.97 (IQR 0.94-0.99). For the dose/volume metrics, there were no statistically significant changes observed except for an increase in bladder hotspot and a decrease of bladder V32.5 Gy and mean dose. The CTV V95% changed from 99.9 % (IQR 98.8-100 %) to 99.6 % (IQR 93.9-100 %). Conclusion: Despite intra-fractional variations of OARs, CTV coverage remained stable during MRI-guided SBRT treatments for the prostate bed.

2.
Cancers (Basel) ; 16(6)2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38539540

RESUMEN

Radiotherapy, a crucial technique in cancer therapy, has traditionally relied on the premise of largely unchanging patient anatomy during the treatment course and encompassing uncertainties by target margins. This review introduces adaptive radiotherapy (ART), a notable innovation that addresses anatomy changes and optimizes the therapeutic ratio. ART utilizes advanced imaging techniques such as CT, MRI, and PET to modify the treatment plan based on observed anatomical changes and even biological changes during the course of treatment. The narrative review provides a comprehensive guide on ART for healthcare professionals and trainees in radiation oncology and anyone else interested in the topic. The incorporation of artificial intelligence in ART has played a crucial role in improving effectiveness, particularly in contour segmentation, treatment planning, and quality assurance. This has expedited the process to render online ART feasible, lowered the burden for radiation oncology practitioners, and enhanced the precision of dynamically personalized treatment. Current technical and clinical progress on ART is discussed in this review, highlighting the ongoing development of imaging technologies and AI and emphasizing their contribution to enhancing the applicability and effectiveness of ART.

3.
J Magn Reson Imaging ; 2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38265188

RESUMEN

Ever since its introduction as a diagnostic imaging tool the potential of magnetic resonance imaging (MRI) in radiation therapy (RT) treatment simulation and planning has been recognized. Recent technical advances have addressed many of the impediments to use of this technology and as a result have resulted in rapid and growing adoption of MRI in RT. The purpose of this article is to provide a broad review of the multiple uses of MR in the RT treatment simulation and planning process, identify several of the most used clinical scenarios in which MR is integral to the simulation and planning process, highlight existing limitations and provide multiple unmet needs thereby highlighting opportunities for the diagnostic MR imaging community to contribute and collaborate with our oncology colleagues. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: Stage 5.

4.
JAMA Oncol ; 10(3): 352-359, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38206614

RESUMEN

Importance: Intrathoracic progression remains the predominant pattern of failure in patients treated with concurrent chemoradiation followed by a consolidation immune checkpoint inhibitor for locally advanced, unresectable non-small cell lung cancer (NSCLC). Objective: To determine the maximum tolerated dose (MTD) and use of hypofractionated concurrent chemoradiation with an adaptive stereotactic ablative radiotherapy (SABR) boost. Design, Setting, and Participants: This was an early-phase, single-institution, radiation dose-escalation nonrandomized controlled trial with concurrent chemotherapy among patients with clinical stage II (inoperable/patient refusal of surgery) or III NSCLC (American Joint Committee on Cancer Staging Manual, seventh edition). Patients were enrolled and treated from May 2011 to May 2018, with a median patient follow-up of 18.2 months. Patients advanced to a higher SABR boost dose if dose-limiting toxic effects (any grade 3 or higher pulmonary, gastrointestinal, or cardiac toxic effects, or any nonhematologic grade 4 or higher toxic effects) occurred in fewer than 33% of the boost cohort within 90 days of follow-up. The current analyses were conducted from January to September 2023. Intervention: All patients first received 4 Gy × 10 fractions followed by an adaptive SABR boost to residual metabolically active disease, consisting of an additional 25 Gy (low, 5 Gy × 5 fractions), 30 Gy (intermediate, 6 Gy × 5 fractions), or 35 Gy (high, 7 Gy × 5 fractions) with concurrent weekly carboplatin/paclitaxel. Main Outcome and Measure: The primary outcome was to determine the MTD. Results: Data from 28 patients (median [range] age, 70 [51-88] years; 16 [57%] male; 24 [86%] with stage III disease) enrolled across the low- (n = 10), intermediate- (n = 9), and high- (n = 9) dose cohorts were evaluated. The protocol-specified MTD was not exceeded. The incidences of nonhematologic acute and late (>90 days) grade 3 or higher toxic effects were 11% and 7%, respectively. No grade 3 toxic effects were observed in the intermediate-dose boost cohort. Two deaths occurred in the high-dose cohort. Two-year local control was 74.1%, 85.7%, and 100.0% for the low-, intermediate-, and high-dose cohorts, respectively. Two-year overall survival was 30.0%, 76.2%, and 55.6% for the low-, intermediate-, and high-dose cohorts, respectively. Conclusions and Relevance: This early-phase, dose-escalation nonrandomized controlled trial showed that concurrent chemoradiation with an adaptive SABR boost to 70 Gy in 15 fractions with concurrent chemotherapy is a safe and effective regimen for patients with locally advanced, unresectable NSCLC. Trial Registration: ClinicalTrials.gov Identifier: NCT01345851.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Radiocirugia , Humanos , Masculino , Anciano , Femenino , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Neoplasias Pulmonares/tratamiento farmacológico , Radiocirugia/efectos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Fraccionamiento de la Dosis de Radiación
5.
Pract Radiat Oncol ; 14(2): e117-e131, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37661040

RESUMEN

Traditionally, external beam radiotherapy (EBRT) for localized prostate cancer (PCa) involved lengthy courses with low daily doses. However, advancements in radiation delivery and a better understanding of prostate radiobiology have enabled the development of shorter courses of EBRT. Ultrahypofractionated radiotherapy, administering doses greater than 5 Gy per fraction, is now considered a standard of care regimen for localized PCa, particularly for intermediate-risk disease. Stereotactic body radiotherapy (SBRT), a specific type of ultrahypofractionated radiotherapy employing advanced planning, imaging, and treatment technology to deliver in five or fewer fractions, is gaining prominence as a cost-effective, convenient, and safe alternative to longer radiotherapy courses. It is crucial to address practical considerations related to patient selection, fractionation scheme, target delineation, and planning objectives. This is especially important in challenging clinical situations where clear evidence for guidance may be lacking. The Radiosurgery Society endorses this case-based guide with the aim of providing a practical framework for delivering SBRT to the intact prostate, exemplified by two case studies. The article will explore common SBRT dose/fractionation schemes and dose constraints for organs-at-risk. Additionally, it will review existing evidence and expert opinions on topics such as SBRT dose escalation, the use of rectal spacers, the role of androgen deprivation therapy in the context of SBRT, SBRT in special patient populations (e.g., high-risk disease, large prostate, high baseline urinary symptom burdens, and inflammatory bowel disease), as well as new imaging-guidance techniques like Magnetic Resonance Imaging for SBRT delivery.


Asunto(s)
Neoplasias de la Próstata , Oncología por Radiación , Radiocirugia , Masculino , Humanos , Neoplasias de la Próstata/radioterapia , Antagonistas de Andrógenos , Próstata
6.
Med Phys ; 51(1): 612-621, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38055353

RESUMEN

BACKGROUND: MR-guided radiation therapy (MRgRT) systems provide superior soft tissue contrast than x-ray based systems and can acquire real-time cine for treatment gating. These features allow treatment planning margins to be reduced, allowing for improved critical structure sparing and reduced treatment toxicity. Despite this improvement, genitourinary (GU) toxicity continues to affect many patients. PURPOSE: (1) To identify dosimetric predictors, potentially in combination with clinical parameters, of GU toxicity following SBRT by leveraging MRgRT to accurately monitor daily dose, beyond predicted dose calculated during planning. (2) Improve awareness of toxicity-sensitive bladder substructures, specifically the trigone and urethra. METHODS: Sixty-nine prostate cancer patients (NCT04384770 clinical trial) were treated on a ViewRay MRIdian MRgRT system, with 40 Gy prescribed to 95% of the PTV in over five fractions. Overall, 17 (24.6%) prostate patients reported acute grade 2 GU toxicity. The CTV, PTV, bladder, bladder wall, trigone, urethra, rectum, and rectal wall were contoured on the planning and daily treatment MRIs. Planning and daily treatment DVHs (0.1 Gy increments), organ doses (min, max, mean), and organ volumes were recorded. Daily dose was estimated by transferring the planning dose distributions to the daily MRI based on the daily setup alignment. Patients were partitioned into a training (55) and testing set (14). Dose features were pre-filtered using a t-test followed by maximum relevance minimum redundancy (MRMR) algorithm. Logistic regression was investigated with regularization to select dosimetric predictors. Specifically, two approaches: time-group least absolute shrinkage and selection (LASSO), and interactive grouped greedy algorithm (IGA) were investigated. Shared features across the planning and five treatment fractions were grouped to encourage consistency and stability. The conventional flat non-temporally grouped LASSO was also evaluated to provide a solid benchmark. After feature selection, a final logistic regression model was trained. Dosimetric regression models were compared to a clinical regression model with only clinical parameters (age, baseline IPSS, prostate gland size, ADT usage, etc.) and a hybrid model, combining the best performing dosimetric features with the clinical parameters, was evaluated. Final model performance was evaluated on the testing set using accuracy, sensitivity, and specificity determined by the optimal threshold of the training set. RESULTS: IGA had the best testing performance with an accuracy/sensitivity/specificity of 0.79/0.67/0.82, selecting 12 groups covering the bladder (V19.8 Gy, V20.5 Gy), bladder wall (19.7 Gy), trigone (15.9, 18.2, 43.3 Gy), urethra (V41.4 Gy, V41.7 Gy), CTV (V41.9 Gy), rectum (V8.5 Gy), and rectal wall (1.2, 44.1 Gy) dose features. Absolute bladder V19.8 Gy and V20.5 Gy were the most important features, followed by relative trigone 15.9  and 18.2 Gy. Inclusion of clinical parameters in the hybrid model with IGA did not significantly change regression performance. CONCLUSION: Overall, IGA feature selection resulted in the best GU toxicity prediction performance. This exploratory study demonstrated the feasibility of identification and analysis of dosimetric toxicity predictors with awareness to sensitive substructures and daily dose to potentially provide consistent and stable dosimetric metrics to guide treatment planning. Further patient accruement is warranted to further assess dosimetric predictor and perform validation.


Asunto(s)
Neoplasias de la Próstata , Traumatismos por Radiación , Radiocirugia , Masculino , Humanos , Radiocirugia/efectos adversos , Traumatismos por Radiación/etiología , Vejiga Urinaria , Neoplasias de la Próstata/radioterapia , Recto , Imagen por Resonancia Magnética , Inmunoglobulina A , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
7.
Int J Radiat Oncol Biol Phys ; 118(4): 986-997, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-37871887

RESUMEN

PURPOSE: Emerging data suggest that trigone dosimetry may be more associated with poststereotactic body radiation therapy (SBRT) urinary toxicity than whole bladder dosimetry. We quantify the dosimetric effect of interfractional displacement and deformation of the whole bladder and trigone during prostate SBRT using on-board, pretreatment 0.35T magnetic resonance images (MRI). METHODS AND MATERIALS: Seventy-seven patients treated with MRI-guided prostate SBRT (40 Gy/5 fractions) on the MRI arm of a phase 3 single-center randomized trial were included. Bladder and trigone structures were contoured on images obtained from a 0.35T simulation MRI and 5 on-board pretreatment MRIs. Dice similarity coefficient (DSC) scores and changes in volume between simulation and daily treatments were calculated. Dosimetric parameters including Dmax, D0.03 cc, Dmean, V40 Gy, V39 Gy, V38 Gy, and V20 Gy for the bladder and trigone for the simulation and daily treatments were collected. Both physician-scored (Common Terminology Criteria for Adverse Events, version 4.03 scale) as well as patient-reported (International Prostate Symptom Scores and the Expanded Prostate Cancer Index Composite-26 scores) acute genitourinary (GU) toxicity outcomes were collected and analyzed. RESULTS: The average treatment bladder volume was about 30% smaller than the simulation bladder volume; however, the trigone volume remained fairly consistent despite being positively correlated with total bladder volume. Overall, the trigone accounted for <2% of the bladder volume. Median DSC for the bladder was 0.79, whereas the median DSC of the trigone was only 0.33. No statistically significant associations between our selected bladder and trigonal dosimetric parameters and grade ≥2 GU toxicity were identified, although numerically, patients with GU toxicity (grade ≥2) had higher intermediate doses to the bladder (V20 Gy and Dmean) and larger volumes exposed to higher doses in the trigone (V40 Gy, V39 Gy, and V38 Gy). CONCLUSIONS: The trigone exhibits little volume change, but considerable interfractional displacement/deformation. As a result, the relative volume of the trigone receiving high doses during prostate SBRT varies substantially between fractions, which could influence GU toxicity and may not be predicted by radiation planning dosimetry.


Asunto(s)
Neoplasias de la Próstata , Exposición a la Radiación , Radiocirugia , Masculino , Humanos , Vejiga Urinaria/efectos de la radiación , Próstata/diagnóstico por imagen , Próstata/patología , Radiocirugia/efectos adversos , Radiocirugia/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia
8.
Int J Radiat Oncol Biol Phys ; 118(5): 1181-1191, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38160916

RESUMEN

PURPOSE: Real-time intrafraction tracking/gating is an integral component of magnetic resonance imaging-guided radiation therapy (MRgRT) and may have contributed to the acute toxicity reduction during prostate stereotactic body radiation therapy observed on the MRgRT-arm of the MIRAGE (MAGNETIC RESONANCE IMAGING-GUIDED Stereotactic Body Radiotherapy for Prostate Cancer) randomized trial (NCT04384770). Herein we characterized intrafraction prostate motion and assessed gating effectiveness. METHODS AND MATERIALS: Seventy-nine patients were treated on an MR-LINAC. Real-time cine imaging was acquired at 4Hz in a sagittal plane. If >10% of the prostate area moved outside of a 3-mm gating boundary, an automatic beam hold was initiated. An in-house tool was developed to retrospectively extract gating signal for all patients and identify the tracked prostate in each cine frame for a subgroup of 40 patients. The fraction of time the prostate was within the gating window was defined as the gating duty cycle (GDC). RESULTS: A total of 391 treatments from 79 patients were analyzed. Median GDC was 0.974 (IQR, 0.916-0.983). Fifty (63.2%) and 24 (30.4%) patients had at least 1 fraction with GDC ≤0.9 and GDC ≤0.8, respectively. Incidence of low GDC fractions among patients appeared stochastic. Patients with minimum GDC <0.8 trended toward more frequent grade 2 genitourinary toxicity compared with those with minimum GDC >0.8 (38% vs 18%, P = .065). Prostate intrafraction motion was mostly along the bladder-rectum axis and predominantly in the superior-anterior direction. Motion in the inferior-posterior direction was associated with significantly higher rate of acute grade 2 genitourinary toxicity (66.7% vs 13.9%, P = .001). Gating limited mean prostate motion during treatment delivery in fractions with a GDC <0.9 (<0.8) to 2.9 mm (2.9 mm) versus 4.1 mm (4.7 mm) for ungated motion. CONCLUSIONS: Fractions with large intrafraction motion were associated with increased toxicity and their occurrence among patients appears stochastic. Real-time tracking/gating effectively mitigated this motion and is likely a major contributing factor of acute toxicity reduction associated with MRgRT.


Asunto(s)
Neoplasias de la Próstata , Radiocirugia , Masculino , Humanos , Radiocirugia/efectos adversos , Radiocirugia/métodos , Estudios Retrospectivos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/patología , Imagen por Resonancia Magnética/métodos
9.
Semin Radiat Oncol ; 34(1): 92-106, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38105098

RESUMEN

High quality radiation therapy requires highly accurate and precise dose delivery. MR-guided radiotherapy (MRgRT), integrating an MRI scanner with a linear accelerator, offers excellent quality images in the treatment room without subjecting patient to ionizing radiation. MRgRT therefore provides a powerful tool for intrafraction motion management. This paper summarizes different sources of intrafraction motion for different disease sites and describes the MR imaging techniques available to visualize and quantify intrafraction motion. It provides an overview of MR guided motion management strategies and of the current technical capabilities of the commercially available MRgRT systems. It describes how these motion management capabilities are currently being used in clinical studies, protocols and provides a future outlook.


Asunto(s)
Radioterapia Guiada por Imagen , Humanos , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Aceleradores de Partículas , Imagen por Resonancia Magnética/métodos
10.
Pract Radiat Oncol ; 2023 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-37914082

RESUMEN

PURPOSE: To evaluate dose volume histogram (DVH) construction differences across 8 major commercial treatment planning systems (TPS) and dose reporting systems for clinically treated plans of various anatomic sites and target sizes. METHODS AND MATERIALS: Dose files from 10 selected clinically treated plans with a hypofractionation, stereotactic radiation therapy prescription or sharp dose gradients such as head and neck plans ranging from prescription doses of 18 Gy in 1 fraction to 70 Gy in 35 fractions, each calculated at 0.25 and 0.125 cm grid size, were created and anonymized in Eclipse TPS, and exported to 7 other major TPS (Pinnacle, RayStation, and Elements) and dose reporting systems (MIM, Mobius, ProKnow, and Velocity) systems for comparison. Dose-volume constraint points of clinical importance for each plan were collected from each evaluated system (D0.03 cc [Gy], volume, and the mean dose were used for structures without specified constraints). Each reported constraint type and structure volume was normalized to the value from Eclipse for a pairwise comparison. A Wilcoxon rank-sum test was used for statistical significance and a multivariable regression model was evaluated adjusting for plan, grid size, and distance to target center. RESULTS: For all DVH points relative to Eclipse, all systems reported median values within 1.0% difference of each other; however, they were all different from Eclipse. Considering mean values, Pinnacle, RayStation, and Elements averaged at 1.038, 1.046, and 1.024, respectively, while MIM, Mobius, ProKnow, and Velocity reported 1.026, 1.050, 1.033, and 1.022, respectively relative to Eclipse. Smaller dose grid size improved agreement between the systems marginally without statistical significance. For structure volumes relative to Eclipse, larger differences are seen across all systems with a range in median values up to 3.0% difference and mean up to 10.1% difference. CONCLUSIONS: Large variations were observed between all systems. Eclipse generally reported, at statistically significant levels, lower values than all other evaluated systems. The nonsignificant change resulting from lowering the dose grid resolution indicates that this resolution may be less important than other aspects of calculating DVH curves, such as the 3-dimensional modeling of the structure.

11.
Cancers (Basel) ; 15(18)2023 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-37760626

RESUMEN

Technological advances in MRI-guided radiation therapy (MRIgRT) have improved real-time visualization of the prostate and its surrounding structures over CT-guided radiation therapy. Seminal studies have demonstrated safe dose escalation achieved through ultrahypofractionation with MRIgRT due to planning target volume (PTV) margin reduction and treatment gating. On-table adaptation with MRI-based technologies can also incorporate real-time changes in target shape and volume and can reduce high doses of radiation to sensitive surrounding structures that may move into the treatment field. Ongoing clinical trials seek to refine ultrahypofractionated radiotherapy treatments for prostate cancer using MRIgRT. Though these studies have the potential to demonstrate improved biochemical control and reduced side effects, limitations concerning patient treatment times and operational workflows may preclude wide adoption of this technology outside of centers of excellence. In this review, we discuss the advantages and limitations of MRIgRT for prostate cancer, as well as clinical trials testing the efficacy and toxicity of ultrafractionation in patients with localized or post-prostatectomy recurrent prostate cancer.

12.
Cancers (Basel) ; 15(16)2023 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-37627090

RESUMEN

There has been a recent effort to treat high-risk ventricular tachycardia (VT) patients through radio-ablation. However, manual segmentation of the VT target is complex and time-consuming. This work introduces ASSET, or Auto-segmentation of the Seventeen SEgments for Tachycardia ablation, to aid in radiation therapy (RT) planning. ASSET was retrospectively applied to CTs for 26 thoracic RT patients (13 undergoing VT ablation). The physician-defined parasternal long-axis of the left ventricle (LV) and the axes generated from principal component analysis (PCA) were compared using mean distance to agreement (MDA) and angle of separation. The manually selected right ventricle insertion point and LVs were used to apply the ASSET model to automatically generate the 17 segments of the LV myocardium (LVM). Physician-defined parasternal long-axis differed from PCA by 1.2 ± 0.3 mm MDA and 6.9 ± 0.7 degrees. Segments differed by 0.69 ± 0.29 mm MDA and 0.89 ± 0.03 Dice similarity coefficient. Running ASSET takes <5 min where manual segmentation took >2 h/patient. Agreement between ASSET and expert contours was comparable to inter-observer variability. Qualitative scoring conducted by three experts revealed automatically generated segmentations were clinically useable as-is. ASSET offers efficient and reliable automatic segmentations for the 17 segments of the LVM for target generation in RT planning.

13.
Neurooncol Adv ; 5(1): vdad028, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37128507

RESUMEN

Background: Tumor surveillance of isocitrate dehydrogenase (IDH) mutant gliomas is accomplished via serial contrast MRI. When new contrast enhancement (CEnew) is detected during postsurgical surveillance, clinicians must assess whether CEnew indicates pseudoprogression (PsP) or tumor progression (TP). PsP has been better studied in IDH wild-type glioblastoma but has not been well characterized in IDH mutant gliomas. We conducted a retrospective study evaluating the incidence, predictors, natural history, and survival of PsP patients in a large cohort of IDH mutant glioma patients treated at a single institution. Methods: We identified 587 IDH mutant glioma patients treated at UCLA. We directly inspected MRI images and radiology reports to identify CEnew and categorized CEnew into TP or PsP using MRI or histopathology. Results: Fifty-six percent of patients developed CEnew (326/587); of these, 92/326 patients (28% of CEnew; 16% of all) developed PsP and 179/326 (55%) developed TP. All PsP patients had prior radiation, chemotherapy, or chemoradiotherapy. PsP was associated with longer overall survival (OS) versus TP patients and similar OS versus no CEnew. PsP differs from TP based on earlier time of onset (median 5.8 vs 17.4 months from treatment, P < .0001) and MRI features that include punctate enhancement and enhancement location. Conclusion: PsP patients represented 28% of CEnew patients and 16% of all patients; PsP patients demonstrated superior outcomes to TP patients, and equivalent survival to patients without CEnew. PsP persists for <1 year, occurs after treatment, and differs from TP based on time of onset and radiographic features. Poor outcomes after CEnew are driven by TP.

15.
Med Phys ; 50(11): 7016-7026, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37222565

RESUMEN

BACKGROUND: A classic approach in medical image registration is to formulate an optimization problem based on the image pair of interest, and seek a deformation vector field (DVF) to minimize the corresponding objective, often iteratively. It has a clear focus on the targeted pair, but is typically slow. In contrast, more recent deep-learning-based registration offers a much faster alternative and can benefit from data-driven regularization. However, learning is a process to "fit" the training cohort, whose image or motion characteristics or both may differ from the pair of images to be tested, which is the ultimate goal of registration. Therefore, generalization gap poses a high risk with direct inference alone. PURPOSE: In this study, we propose an individualized adaptation to improve test sample targeting, to achieve a synergy of efficiency and performance in registration. METHODS: Using a previously developed network with an integrated motion representation prior module as the implementation backbone, we propose to adapt the trained registration network further for image pairs at test time to optimize the individualized performance. The adaptation method was tested against various characteristics shifts caused by cross-protocol, cross-platform, and cross-modality, with test evaluation performed on lung CBCT, cardiac MRI, and lung MRI, respectively. RESULTS: Landmark-based registration errors and motion-compensated image enhancement results demonstrated significantly improved test registration performance from our method, compared to tuned classic B-spline registration and network solutions without adaptation. CONCLUSIONS: We have developed a method to synergistically combine the effectiveness of pre-trained deep network and the target-centric perspective of optimization-based registration to improve performance on individual test data.


Asunto(s)
Aprendizaje Profundo , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Pulmón , Algoritmos
16.
Clin Transl Radiat Oncol ; 40: 100603, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36896266

RESUMEN

Purpose: To identify any clinical or dosimetric parameters that predict which individuals may benefit from on-table adaptation during pancreas stereotactic body radiotherapy (SBRT) with MRI-guided radiotherapy. Methods and materials: This was a retrospective study of patients undergoing MRI-guided SBRT from 2016 to 2022. Pre-treatment clinical variables and dosimetric parameters on the patient's simulation scan were recorded for each SBRT course, and their ability to predict for on-table adaptation was analyzed using ordinal logistic regression. The outcome measure was number of fractions adapted. Results: Sixty-three SBRT courses consisting of 315 fractions were analyzed. Median prescription dose was 40 Gy in five fractions (range, 33-50 Gy); 52% and 48% of courses were prescribed ≤40 Gy and >40 Gy, respectively. The median minimum dose delivered to 95% (D95) of the gross tumor volume (GTV) and planning target volume (PTV) was 40.1 Gy and 37.0 Gy, respectively. Median number of fractions adapted per course was three, with 58% (183 out of 315) total fractions adapted. On univariable analysis, the prescription dose (>40 Gy vs ≤40 Gy), GTV volume, stomach V20 and V25, duodenum V20 and dose maximum, large bowel V33 and V35, GTV dose minimum, PTV dose minimum, and gradient index were significant determinants for adaptation (all p < 0.05). On multivariable analysis, only the prescription dose was significant (adjusted odds ratio 19.7, p = 0.005), but did not remain significant after multiple test correction (p = 0.08). Conclusions: The likelihood of needing on-table adaptation could not be reliably predicted a priori using pre-treatment clinical characteristics, dosimetry to nearby organs at risk, or other dosimetric parameters based on the patient's anatomy at the time of simulation, suggesting the critical importance of day-to-day variations in anatomy and increasing access to adaptive technology for pancreas SBRT. A higher (ablative) prescription dose was associated with increased use of adaptation.

17.
Clin Transl Radiat Oncol ; 39: 100594, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36880064

RESUMEN

Predictors of genitourinary toxicity after post-prostatectomy radiotherapy remain elusive. A previously defined germline DNA signature (PROSTOX) has shown predictive ability for late grade ≥ 2 GU toxicity after intact prostate stereotactic body radiotherapy. We explore whether PROSTOX would predict toxicity among patients receiving post-prostatectomy SBRT on a phase II clinical trial.

18.
Radiother Oncol ; 183: 109631, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36934894

RESUMEN

BACKGROUND AND PURPOSE: We examined the interfractional variations of clinical target volumes (CTVs), planning target volumes (PTVs), and organs-at-risk (OARs) in patients receiving MRI-guided stereotactic body radiotherapy (SBRT) to the prostate bed and evaluated the potential role of adaptive planning. MATERIALS AND METHODS: 31 patients received 30-34 Gy in five fractions to the prostate bed on a phase II clinical trial. OARs, CTVs, and PTVs were retrospectively contoured on daily pretreatment MRIs (n = 155). Geometric comparisons were made between initial planning contours and daily pretreatment contours. Predicted treatment plans for each fraction were evaluated using the following constraints: CTV V95%>93%, PTV V95%>90%, bladder Dmax < 36.7 Gy, bladder V32.5 Gy < 35%, rectum Dmax < 36.7 Gy, rectum V27.5 Gy < 45%, rectum 32.5 Gy < 30%, and rectal wall V24Gy < 50%. Adaptive planning was simulated for all fractions that failed to meet these criteria. Plans were then re-evaluated. RESULTS: Median change in volume was 0.48% for CTV, -24.5% for bladder, and 6.95% for rectum. Median DSC was 0.89 for CTV, 0.79 for bladder, and 0.76 for rectum. 145/155 fractions (93.5%) met CTV V95%>93%. 75/155 fractions (48.4%) failed at least one OAR dose constraint. Overall, 83/155 fractions (53.5%) met criteria for adapting planning. This affected 24/31 patients (77.4%). Following adaptive planning, all fractions met CTV V95%>93% and PTV V95%>90% and 120/155 fractions (77.4%) met all OAR constraints. CONCLUSION: Due to significant interfractional variations in anatomy, a majority of fractions failed to meet both target volume and OAR constraints. However, adaptive planning was effective in overcoming these anatomic changes. Adaptive planning should be routinely considered in prostate bed SBRT.


Asunto(s)
Neoplasias de la Próstata , Radiocirugia , Radioterapia Guiada por Imagen , Radioterapia de Intensidad Modulada , Masculino , Humanos , Próstata , Estudios Retrospectivos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Prostatectomía , Imagen por Resonancia Magnética , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/cirugía , Órganos en Riesgo
19.
J Nucl Med ; 64(6): 902-909, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36759200

RESUMEN

The aim of this study was to analyze the patterns of prostate bed (PB) recurrence in prostate cancer patients experiencing prostate-specific antigen (PSA) persistence (BCP) or biochemical recurrence (BCR) after radical prostatectomy using 68Ga-PSMA-11 PET/CT (68Ga-PSMA PET) in relation to the Radiation Therapy Oncology Group (RTOG) clinical target volumes (CTVs). Methods: This single-center, retrospective analysis included patients with BCP or BCR after radical prostatectomy and PB recurrence on 68Ga-PSMA PET. The PB recurrences were delineated by nuclear medicine physicians, the CTVs by radiation oncologists contouring guidelines on the 68Ga-PSMA PET, respectively, masked from each other. The coverage of the 68Ga-PSMA PET recurrence was categorized as PSMA recurrence completely covered, partially covered, or not covered by the RTOG-based CTV. Further, we evaluated the differences in PSMA recurrence patterns among patients with different 68Ga-PSMA PET staging (miTNM). Mann-Whitney U tests, the chi-square test, and Spearman (ρ) correlation analysis were used to investigate associations between CTV coverage and 68Ga-PSMA PET-based tumor volume, serum PSA levels, miTNM, and rectal/bladder involvement. Results: A total of 226 patients were included in the analysis; 127 patients had PSMA recurrence limited to the PB (miTrN0M0), 30 had pelvic nodal disease (miTrN1M0), 32 had extrapelvic disease (miTrN0M1), and 37 had both pelvic nodal disease and extrapelvic disease (miTrN1M1). In the miTrN0M0 cohort, the recurrence involved the rectal and bladder walls in 12 of 127 (9%) and 4 of 127 (3%), respectively. The PSMA-positive PB recurrences were completely covered by the CTV in 68 of 127 patients (53%), partially covered in 43 of 127 (34%), and not covered in 16 of 127 (13%). Full coverage was associated with a smaller tumor volume (P = 0.043), a lack of rectal/bladder wall involvement (P = 0.03), and lower miTNM staging (P = 0.035) but not with lower serum PSA levels (P = 0.979). Conclusion: Our study suggests that 68Ga-PSMA PET can be a valuable tool for guiding salvage radiation therapy (SRT) planning directed to the PB in the setting of postoperative BCR or BCP. These data should be incorporated into the redefinition of PB contouring guidelines.


Asunto(s)
Próstata , Neoplasias de la Próstata , Masculino , Humanos , Próstata/patología , Antígeno Prostático Específico , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Retrospectivos , Radioisótopos de Galio , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/cirugía , Prostatectomía , Terapia Recuperativa , Recurrencia Local de Neoplasia/patología
20.
BJU Int ; 132(1): 65-74, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36797449

RESUMEN

OBJECTIVE: To assess the efficacy of 177 Lu-PNT2002, a novel radiolabelled small molecule that binds with high affinity to prostate-specific membrane antigen (PSMA), in combination with stereotactic body radiotherapy (SBRT) to all sites of metastasis, vs SBRT alone, in men with oligorecurrent metastatic hormone-sensitive prostate cancer (mHSPC). PATIENTS AND METHODS: The 177 Lutetium-PSMA Neoadjuvant to Ablative Radiotherapy for Oligorecurrent Prostate Cancer (LUNAR) trial is an open-label, randomized, stratified, two-arm, single-centre, Phase 2 trial to compare the efficacy and safety of neoadjuvant 177 Lu-PNT2002 plus SBRT vs SBRT alone in men with oligorecurrent mHSPC. Key eligibility criteria include one to five lesions identified on a PSMA positron emission tomography (PET)/computed tomography (CT) scan centrally reviewed by a board-certified nuclear medicine physician. Key exclusion criteria include castrate-resistant disease, de novo oligometastatic disease and receipt of androgen deprivation therapy (ADT) within 6 months of trial enrolment. The trial aims to enrol 100 patients who will be centrally randomized to one of the two treatment arms, in a 1:1 ratio. Patients in the control arm receive SBRT to all sites of disease. Patients in the experimental arm receive two cycles of neoadjuvant 177 Lu-PNT2002 (6.8 GBq) 6-8 weeks apart, followed by an interval PSMA PET/CT in 4-6 weeks and dose-adapted SBRT to all sites of disease 1-2 weeks later. The primary endpoint is progression-free survival. Secondary endpoints are radiographic and prostate-specific antigen-based progression, acute and late physician-scored toxicity, patient-reported quality of life, ADT-free survival, time to progression, overall survival, locoregional control, and duration of response. Enrolment in the study commenced in September 2022. RESULTS AND CONCLUSIONS: The addition of 177 Lu-PNT2002 to metastasis-directed therapy alone may potentially further forestall disease progression. The results of this Phase 2 trial will determine, for the first time in a randomized fashion, the added benefit of 177 Lu-PNT2002 to SBRT in patients with oligorecurrent mHSPC.


Asunto(s)
Neoplasias de la Próstata Resistentes a la Castración , Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/patología , Lutecio/uso terapéutico , Tomografía Computarizada por Tomografía de Emisión de Positrones , Calidad de Vida , Terapia Neoadyuvante , Antagonistas de Andrógenos/uso terapéutico , Antígeno Prostático Específico , Neoplasias de la Próstata Resistentes a la Castración/patología , Ensayos Clínicos Controlados Aleatorios como Asunto , Ensayos Clínicos Fase II como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...