Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Food Chem ; 428: 136789, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37423110

RESUMEN

A simple and rapid colorimetric method for the detection of melamine in milk samples is described. Polythymidine oligonucleotide was adsorbed on to the surface of gold nanoparticles (AuNPs), protecting it from aggregation. In the presence of melamine, polythymidine oligonucleotide combined with melamine formed a double-strand DNA-like structure, allowing AuNPs aggregation. In the presence of positively charged SYBR Green I (SG I), AuNPs were further aggregated. In the presence of melamine and SG I, aggregation of AuNPs was synergistic. Thus, in this principle, melamine can be detected visually. Plasmon resonance peak changes enabled detection of melamine quantitatively using UV-vis spectroscopy. The limit of detection for this colorimetric method was 16 µg L-1 with a good linear range from 19.5 µg L-1 to 1.25 × 103 µg L-1, and detection took only 1 min. The method was successfully applied for detection of melamine in milk samples.


Asunto(s)
Nanopartículas del Metal , Animales , Nanopartículas del Metal/química , Oro/química , Leche/química , Triazinas/análisis , Colorimetría/métodos , Oligonucleótidos , Límite de Detección
2.
J Dairy Sci ; 106(9): 5930-5939, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37474367

RESUMEN

Escherichia coli O157:H7 poses a threat to humans. Traditional ELISA is not a sensitive method for the detection of E. coli O157:H7. Here, an efficient method was designed for improving the load capacity of alkaline phosphatase (ALP) with streptavidin scaffolded DNA tetrad (SS-DNAt). With more ALP, more ascorbic acid 2-phosphate was catalyzed to ascorbic acid that was used to synthesize fluorescence poly adenine-thymine-templated copper nanoclusters. Based on SS-DNAt, fluorescence ELISA was successfully proposed for improving the sensitivity for detection of E. coli O157:H7 in milk samples. The method showed a linear range of 104 to 106 cfu/mL. The limit of detection of fluorescence ELISA was 3.75 × 103 cfu/mL and 6.16-fold better than that of traditional ELISA. The recovery of the fluorescence ELISA was 86.7 to 93.6% with the coefficient of variation of 5.6 to 10.5% in milk. This method could be used to detect hazardous material in food.


Asunto(s)
Escherichia coli O157 , Humanos , Animales , Estreptavidina , Ensayo de Inmunoadsorción Enzimática/veterinaria , Leche , ADN , Microbiología de Alimentos
3.
Nanoscale ; 9(43): 17133-17142, 2017 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-29087426

RESUMEN

The carrier dynamics of lead sulphide quantum dot (PbS QD) drop cast films and closely packed ordered Langmuir-Blodgett films are studied with ultra-fast femtosecond transient absorption spectroscopy. The photo-induced carrier temperature is extracted from transient absorption spectra and monitored as a function of time delay. The cooling dynamics of carriers in PbS QDs suggest a reduction of the carrier energy loss rate at longer time delays through the retardation of the longitudinal optical (LO) phonon decay due to partial heating of acoustic phonon modes. A slowed hot carrier cooling time up to 116 ps is observed in the drop cast film. A faster cooling rate was also observed in the highly compact Langmuir-Blodgett film due to the enhanced carrier-LO phonon coupling strength arising from the Coulombic interaction in neighboring QDs, which is verified by temperature dependent steady state PL measurements.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...