Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Neoplasma ; 70(1): 123-135, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36916928

RESUMEN

Since metastasis remains the primary reason for colorectal cancer (CRC) associated death, a better understanding of the molecular mechanism underlying CRC metastasis is urgently needed. Here, we elucidated the role of Cathepsin C (CTSC) in promoting CRC metastasis. The expression of CTSC was detected by real-time PCR and immunohistochemistry in the human CRC cohort. The metastatic capacities of CTSC-mediated metastasis were analyzed by in vivo metastasis model. Elevated CSTC expression was positively associated with tumor differentiation, tumor invasion, lymph node metastasis, and AJCC stage and indicated poor prognosis in human CRC. CTSC overexpression in CRC cells promoted myeloid-derived suppressor cells (MDSCs) and tumor-associated macrophages (TAMs) recruitment by the CSF1/CSF1R axis. In contrast, the knockdown of CSF1 reduced CTSC-mediated MDSCs and TAMs infiltration and CRC metastasis. Depletion of either MDSCs or TAMs decreased CTSC-mediated CRC metastasis. In human CRC tissues, CTSC expression was positively associated with intratumoral MDSCs and TAMs infiltration. Furthermore, the combination of CTSC inhibitor AZD7986 and anti-PD-L1 antibody blocked CTSC-induced CRC metastasis. CTSC overexpression promoted MDSCs and TAMs infiltration by CSF1/CSF1R axis. Interruption of this oncogenic loop may provide a promising treatment strategy for inhibiting CTSC-driven CRC metastasis.


Asunto(s)
Catepsina C , Neoplasias Colorrectales , Humanos , Diferenciación Celular , Línea Celular Tumoral , Neoplasias Colorrectales/patología , Metástasis Linfática , Metástasis de la Neoplasia
2.
Diagn Interv Radiol ; 26(4): 264-270, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32490833

RESUMEN

PURPOSE: We aimed to explore the influence of tube voltage, current and iterative reconstruction (IR) in computed tomography perfusion imaging (CTPI) and to compare CTPI parameters with microvessel density (MVD). METHODS: Hepatic CTPI with three CTPI protocols (protocol A, tube voltage/current 80 kV/40 mAs; protocol B, tube voltage/current 80 kV/80 mAs; protocol C: tube voltage/current 100 kV/80 mAs) were performed in 25 rabbit liver VX2 tumor models, and filtered back projection (FBP) and IR were used for reconstruction of raw data. Hepatic arterial perfusion (HAP), hepatic portal perfusion (HPP), total perfusion (TP), hepatic arterial perfusion index (HPI), blood flow (BF) and blood volume (BV) of VX2 tumor and normal hepatic parenchyma were measured. Image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were quantified and radiation dose was recorded. MVD was counted using CD34 stain and compared with CTPI parameters. RESULTS: The highest radiation dose was found in protocol C, followed by protocols B and A. IR lowered image noise and improved SNR and CNR in all three protocols. There was no statistical difference between HAP, HPP, TP, HPI, BF and BV of VX2 tumor and normal hepatic parenchyma among the three protocols (P > 0.05) with FBP or IR reconstruction, and no statistical difference between IR and FBP reconstruction (P > 0.05) in either protocol. MVD had a positive linear correlation with HAP, TP, BF, with best correlation observed with HAP; MVD of VX2 tumor showed no or poor correlation with HPI and BV. CONCLUSION: CTPI parameters are not affected by tube voltage, current or reconstruction algorithm; HAP can best reflect MVD, but no correlation exists between BV and MVD.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Hígado/patología , Imagen de Perfusión/instrumentación , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Animales , Circulación Sanguínea/fisiología , Volumen Sanguíneo/fisiología , Femenino , Arteria Hepática/diagnóstico por imagen , Hígado/irrigación sanguínea , Masculino , Densidad Microvascular , Modelos Animales , Vena Porta/diagnóstico por imagen , Conejos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Relación Señal-Ruido
3.
Magn Reson Imaging ; 46: 64-69, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29103979

RESUMEN

OBJECT: To explore microcirculation features with intravoxel incoherent motion (IVIM) and to compare IVIM with CT perfusion imaging (CTPI) and microvessel density (MVD). MATERIALS AND METHODS: Hepatic CTPI and IVIM were performed in 16 rabbit liver VX2 tumor models. Hepatic arterial perfusion (HAP), hepatic arterial perfusion index (HPI), Blood flow (BF), and blood volume (BV) from CTPI were measured. Apparent diffusion coefficient (ADC), true diffusion coefficient (D), perfusion fraction (f), and pseudo-diffusion coefficient (D*) from IVIM were measured. MVD was counted with CD34 stain. The microcirculation features with IVIM were compared with CTPI parameters and MVD. RESULTS: Strong linear correlations were found between D value (0.89±0.21×10-3mm2/s) and HAP (15.83±6.97ml/min/100mg) (r=0.755, P=0.001) and between f value (12.64±6.66%) and BV (9.74±5.04ml/100mg) (r=0.693, P=0.004). Moderate linear correlations were observed between ADC (1.07±0.32×10-3mm2/s) and HAP (r=0.538, P=0.039), respectively; and between D value and MVD (9.31±2.57 vessels at 400×magnification) (r=0.509, P=0.044). No correlations were found between D* (119.90±37.67×10-3mm2/s) and HAP, HPI (68.34±12.91%), BF (4.95±2.16ml/min/100mg), BV. CONCLUSION: IVIM parameters can characterize microcirculation to certain extent and separate it from pure water molecular diffusion. There is fair correlation between D or ADC value and CTPI parameters or MVD, but no correlation between D* or f value and CTPI parameters or MVD except f value and BV, which is still unclear and need further clinical studies to validate.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias Hepáticas/diagnóstico por imagen , Hígado/diagnóstico por imagen , Movimiento (Física) , Imagen de Perfusión , Tomografía Computarizada por Rayos X , Animales , Volumen Sanguíneo , Femenino , Masculino , Microcirculación , Microvasos/patología , Neoplasias/patología , Conejos
4.
Coron Artery Dis ; 26(4): 308-16, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25714067

RESUMEN

PURPOSE: To assess the impact of chest circumference (CC)-adjusted tube current and iterative reconstructions (iDose) on individualized radiation dose reduction and image quality (IQ) in ECG-triggered computed tomography coronary angiography (CTCA). MATERIALS AND METHODS: A total of 102 patients underwent retrospectively ECG-triggered CTCA utilizing CC-adapted tube current [mAs=1000×(0.051×CC-23.765)/900] and filtered back projection (FBP) reconstruction (group A). On the basis of the CC-adjusted tube current technique, 54 patients (group B) underwent retrospective ECG-triggered CTCA with a 20% mAs reduction compared with group A and 90 patients (group C) underwent prospective ECG-triggered CTCA with an 80% mAs reduction compared with group A; both groups B and C were reconstructed with FBP and iDose. Subjective IQ was assessed, and image noise, signal-to-noise, and contrast-to-noise ratios (SNR and CNR) were quantified. RESULTS: Patients in group A had the highest radiation dose, followed by group B and group C. iDose provided decreased image noise and increased SNR and CNR, as did subjective IQ. The image noise was higher and SNR and CNR in group B were obviously lower than those in group A with FBP, but in group B, iDose4 increased the mean objective IQ. There was no difference between group B with iDose and group A with FBP, as was the case with subjective IQ. CONCLUSION: The combination of a CC-adapted technique, prospective triggering, and partial iterative reconstruction techniques reduces the radiation dose significantly, without significant degradation of IQ.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...