Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 12(7)2023 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-37048729

RESUMEN

BACKGROUND: Little is known about the influence of the duration of the kidney back-table preparation period and kidney temperature on graft outcomes after transplantation. The aim of this study is to investigate the back-table duration and its relation to graft outcome and the relation between kidney temperature and graft outcome. METHODS: In this prospective cohort study, deceased donor kidney temperature is measured at fixed time points using an infrared thermometer during back-table preparation and transplantation. Additionally, the back-table duration is measured using a timer. RESULTS: Between September 2020 and July 2021, 49 kidneys were prospectively included in this study. Median back-table duration was 33.7 (standard deviation ± 14.1) min and donor kidney temperature increased up to 14.9 °C (±2.8) after 60 min of back-table preparation. Mean implantation time was 24.9 (±7.6) min and kidney temperature increased up to 25.9 °C (±2.4) after 30 min of implantation time. Longer back-table duration was significantly associated with higher rates of delayed graft function (p = 0.037). However, this observation did not sustain at 3 and 6-months post-transplantation. No association was found between kidney temperature and graft outcomes. CONCLUSION: Longer back-table duration is significantly associated with DGF after deceased donor kidney transplantation. No association was observed between kidney temperature and graft outcomes of deceased donor kidneys.

2.
Surgery ; 173(6): 1438-1446, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36973127

RESUMEN

BACKGROUND: Difficulty scoring systems are important for the safe, stepwise implementation of new procedures. We designed a retrospective observational study for building a difficulty score for robotic pancreatoduodenectomy. METHODS: The difficulty score (PD-ROBOSCORE) aims at predicting severe postoperative complications after robotic pancreatoduodenectomy. The PD-ROBOSCORE was developed in a training cohort of 198 robotic pancreatoduodenectomies and was validated in an international multicenter cohort of 686 robotic pancreatoduodenectomies. Finally, all centers tested the model during the early learning curve (n = 300). Growing difficulty levels (low, intermediate, high) were defined using cut-off values set at the 33rd and 66th percentile (NCT04662346). RESULTS: Factors included in the final multivariate model were a body mass index of ≥25 kg/m2 for males and ≥30 kg/m2 for females (odds ratio:2.39; P < .0001), borderline resectable tumor (odd ratio:1.98; P < .0001), uncinate process tumor (odds ratio:1.69; P < .0001), pancreatic duct size <4 mm (odds ratio:1.59; P < .0001), American Society of Anesthesiologists class ≥3 (odds ratio:1.59; P < .0001), and hepatic artery originating from the superior mesenteric artery (odds ratio:1.43; P < .0001). In the training cohort, the absolute score value (odds ratio = 1.13; P = .0089) and difficulty groups (odds ratio = 2.35; P = .041) predicted severe postoperative complications. In the multicenter validation cohort, the absolute score value predicted severe postoperative complications (odds ratio = 1.16, P < .001), whereas the difficulty groups did not (odds ratio = 1.94, P = .082). In the learning curve cohort, both absolute score value (odds ratio:1.078, P = .04) and difficulty groups (odds ratio: 2.25, P = .017) predicted severe postoperative complications. Across all cohorts, a PD-ROBOSCORE of ≥12.51 doubled the risk of severe postoperative complications. The PD-ROBOSCORE score also predicted operative time, estimated blood loss, and vein resection. The PD-ROBOSCORE predicted postoperative pancreatic fistula, delayed gastric emptying, postpancreatectomy hemorrhage, and postoperative mortality in the learning curve cohort. CONCLUSION: The PD-ROBOSCORE predicts severe postoperative complications after robotic pancreatoduodenectomy. The score is readily available via www.pancreascalculator.com.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Robótica , Masculino , Femenino , Humanos , Pancreaticoduodenectomía/efectos adversos , Pancreaticoduodenectomía/métodos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Páncreas/cirugía , Fístula Pancreática/etiología , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/patología
3.
Transplant Proc ; 53(6): 1836-1845, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34049699

RESUMEN

BACKGROUND: Organ transplantation is a life-saving intervention that improves quality of life of patients with irreversible organ failure. Although exercise training immediately after transplantation has been suggested to be beneficial, such interventions remain rare in stable transplant recipients, whereas effects of high-intensity training (HIT) are even less frequently investigated. Moreover, sustainability of such interventions has not yet been reported. We investigated the effects of a 6-month, cycling-based HIT program on physical performance in long-term stable solid organ transplant (SOT) recipients, with follow-up evaluation after 6 months. METHODS: Forty-two adult, stable, and selected SOT recipients participated in a 6-month individualized home- and group-based HIT program. Exercise capacity (VO2max), maximal power (Wmax), and body mass index were measured before, at the end, and 6 months after completion of the intervention. RESULTS: The study comprised 12 heart, 7 lung, 8 liver, and 15 kidney recipients (mean age, 41.4 ± 11.1 years; median time posttransplant, 3.4 [1.7-8.0] years). For 6 months, VO2max increased in the heart, lung, and kidney groups, Wmax increased in the heart group, and body mass index decreased in the liver group. Six months after the HIT program, the achieved gain in exercise capacity had disappeared in all groups. CONCLUSION: Despite voluntary participation selection bias, our observations indicate that HIT is safe and may result in a beneficial effect on physical performance in selected, stable SOT recipients. However, there was no sustained beneficial effect once training stopped. Larger scale and longer term studies are still required to investigate longevity of improvement and overall beneficial effects on clinical outcomes.


Asunto(s)
Trasplante de Órganos , Receptores de Trasplantes , Adulto , Ejercicio Físico , Tolerancia al Ejercicio , Humanos , Persona de Mediana Edad , Trasplante de Órganos/efectos adversos , Calidad de Vida
5.
J Vasc Surg Cases Innov Tech ; 6(4): 562-565, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33134643

RESUMEN

Surgical shunt therapy may be required when pharmacologic, endoscopic, and radiologic treatment of chronic splanchnic vein thrombosis have failed. In this case report, we present a new interposition shunt for the treatment of refractory rectal variceal bleeding: the inferior mesoiliacal shunt between the inferior mesenteric vein and the left common iliac vein using a cryopreserved iliac venous graft. The postoperative course was complicated by shunt thrombosis at day 2, probably owing to inadvertent interruption of anticoagulation and a decrease in the shunt flow rate. Surgical thrombectomy was performed successfully. The patient presented no relapse of rectal bleeding and was asymptomatic and well at the 12-month follow-up.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA