Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ultrasound Med Biol ; 35(12): 2042-54, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19854566

RESUMEN

The small size, high heart rate and small tissue displacement of a mouse require small sensors that are capable of high spatial and temporal tissue displacement resolutions and multichannel data acquisition systems with high sampling rates for simultaneous measurement of high fidelity signals. We developed and evaluated an ultrasound-based mouse vascular research system (MVRS) that can be used to characterize vascular physiology in normal, transgenic, surgically altered and disease models of mice. The system consists of multiple 10/20MHz ultrasound transducers, analog electronics for Doppler displacement and velocity measurement, signal acquisition and processing electronics and personal computer based software for real-time and off-line analysis. In vitro testing of the system showed that it is capable of measuring tissue displacement as low as 0.1mum and tissue velocity (mum/s) starting from 0. The system can measure blood velocities up to 9m/s (with 10MHz Doppler at a PRF of 125kHz) and has a temporal resolution of 0.1 milliseconds. Ex vivo tracking of an excised mouse carotid artery wall using our Doppler technique and a video pixel tracking technique showed high correlation (R(2)=0.99). The system can be used to measure diameter changes, augmentation index, impedance spectra, pulse wave velocity, characteristic impedance, forward and backward waves, reflection coefficients, coronary flow reserve and cardiac motion in murine models. The system will facilitate the study of mouse vascular mechanics and arterial abnormalities resulting in significant impact on the evaluation and screening of vascular disease in mice.


Asunto(s)
Interpretación de Imagen Asistida por Computador/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Transductores , Ultrasonografía Doppler de Pulso/instrumentación , Ultrasonografía Doppler de Pulso/veterinaria , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Ratones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
IEEE Trans Biomed Eng ; 52(10): 1764-70, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16235662

RESUMEN

We have developed and evaluated a high-frequency, real-time pulsed Doppler and physiological signal acquisition and analysis system specifically for use in mice. The system was designed to provide sampling rates up to 125 kilosamples/s (ksps) with software controlled data acquisition and analysis in real-time. Complex fast Fourier transforms are performed every 0.1 ms (or longer up to 10 ms) to provide 0.1-ms time resolution and using 64-1024 sample segments of the Doppler audio signals resulting in frequency resolution ranging from 122-1953 Hz. The system was evaluated by its response to frequency swept signals with slopes (accelerations) and magnitudes (velocities) comparable to actual blood velocity signals in mice. Signals up to a maximum frequency of 125 kHz and a maximum acceleration of 20 MHz/s were processed and displayed. This corresponds to a maximum velocity of 480 (960) cm/s and a maximum acceleration of 750 (1500) m/s2 when Doppler shifts are measured with a 20- (10-) MHz probe, thereby allowing us to measure high stenotic jet velocities. The directional transitions of the spectrogram across zero frequency and across Nyquist frequency (sampling rate/2) were smooth with no discernible artifacts. Signals with period as low as 2 ms were processed and displayed at sweep speed that is ten times that in clinical Doppler systems, so that measurements of small temporal events can be made with precision. Thus, the new system can measure higher blood velocities with higher spatial and temporal resolution than is possible using clinical Doppler systems adapted for use in mice.


Asunto(s)
Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Velocidad del Flujo Sanguíneo , Ecocardiografía Doppler de Pulso/instrumentación , Hemorreología/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Algoritmos , Animales , Inteligencia Artificial , Ecocardiografía Doppler de Pulso/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Hemorreología/métodos , Interpretación de Imagen Asistida por Computador/métodos , Ratones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA