Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Food Chem ; 406: 135032, 2023 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-36493572

RESUMEN

During the 2020-21 olive oil campaign, the contribution of harvesting operations to mineral oil saturated (MOSH) and aromatic hydrocarbon (MOAH) contamination was studied. Oils extracted from hand-picked olives (15 different olive groves) generally had background MOSH (<2.7 mg/kg), and no quantifiable MOAH. In 40% of the cases, an important contamination increase was observed after harvesting operations. Except for one sample (325.8 and 111.0 mg/kg of MOSH and MOAH, respectively), other samples reached 4.3-33.7 mg/kg of MOSH and 1.1-11.3 mg/kg of MOAH. Accidental leaks of lubricants and/or contact with lubricated mechanical parts, were identified as important sources of contamination. Chromatographic traces obtained by on-line high-performance liquid chromatography (HPLC)-gas chromatography (GC)-flame ionization detection (FID) allowed for source identification. A comprehensive two-dimensional gas chromatographic platform (GC × GC) with parallel FID/MS detection was implemented for confirmation and to attempt the characterization of the contaminations. Good harvesting practices are suggested to minimize contamination risks.


Asunto(s)
Hidrocarburos Aromáticos , Aceite Mineral , Aceite Mineral/química , Aceite de Oliva/análisis , Contaminación de Alimentos/análisis , Hidrocarburos Aromáticos/análisis , Cromatografía de Gases/métodos
2.
Sci Rep ; 12(1): 10413, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35729207

RESUMEN

Several studies highlighted a correlation between exhaled air volatile organic compounds (VOCs) and some pathological conditions, such as chronic kidney disease (CKD), chronic liver disease, etc. In fact, in literature has been reported that CKD is characterized by an increased concentration of ammonia, trimethylamine (TMA) and isoprene compared to healthy subjects. Currently, there is not a validate and standardized method to detect VOCs. For this purpose, we examined the utility of selected ion flow tube-mass spectrometry (SIFT-MS) to measure VOCs in CKD patients and we evaluated the possible correlation between VOCs and the presence of CKD and its stage. We enrolled 68 CKD patients under conservative therapy and 54 healthy subjects. The analysis of the VOCs of the exhaled air of the enrolled subjects was performed by SIFT-MS. Among all the VOCs analyzed, the most relevant results by ROC curves were observed for TMA, acetone, ammonia and dimethyl sulfide. We found that a breath TMA concentration superior to 26 ppbv characterizes a 6.11 times greater risk of CKD, compared to subjects with lower levels. Moreover, we detected an increased concentration of acetone and ammonia in CKD patients compared to healthy subjects. We highlight the potential utility of SIFT-MS in CKD clinical management.Clinical trial registry: R.S. 15.19 of 6 February 2019.


Asunto(s)
Insuficiencia Renal Crónica , Compuestos Orgánicos Volátiles , Acetona/análisis , Amoníaco , Pruebas Respiratorias/métodos , Humanos , Insuficiencia Renal Crónica/diagnóstico , Compuestos Orgánicos Volátiles/análisis
3.
J Chromatogr A ; 1627: 461396, 2020 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-32823101

RESUMEN

Comprehensive two-dimensional gas chromatography (GC×GC) based on flow-modulation (FM) is gaining increasing attention as an alternative to thermal modulation (TM), the recognized GC×GC benchmark, thanks to its lower operational cost and rugged performance. An accessible, rational procedure to perform method translation between the two platforms would be highly valuable to facilitate compatibility and consequently extend the flexibility and applicability of GC×GC. To enable an effective transfer, the methodology needs to ensure preservation of the elution pattern, separation power, and sensitivity. Here, a loop-type thermal modulation system with dual detection (TM-GC×GC-MS/FID) used for the targeted analysis of allergens in fragrances is selected as reference method. Initially, six different columns configurations are systematically evaluated for the flow-modulated counterpart. The set-up providing the most consistent chromatographic separation (20 m x 0.18 mm dc x 0.18 µm df + 1.8 m x 0.18 mm dc x 0.18 µm df) is further evaluated to assess its overall performance in terms of sensitivity, linearity, accuracy, and pattern reliability. The experimental results convincingly show that the method translation procedure is effective and allows successful transfer of the target template metadata. Additionally, the FM-GC×GC-MS/FID system is suitable for challenging applications such as the quantitative profiling of complex fragrance materials.


Asunto(s)
Cromatografía de Gases/métodos , Alérgenos/análisis , Calibración , Cromatografía de Gases/normas , Ionización de Llama , Límite de Detección , Perfumes/análisis , Perfumes/normas , Reproducibilidad de los Resultados
4.
Int J Biol Markers ; 34(2): 205-209, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30852948

RESUMEN

BACKGROUND: The purpose of this case report is to describe the potential that metabolomics breath analysis may have in cancer disease monitoring. The advances in mass spectrometry instrumentation allow the accurate real-time analysis of volatile metabolites exhaled in the breath. The application of such non-invasive devices may provide innovative and complementary monitoring of the physio-pathological conditions of cancer patients. CASE PRESENTATION: A 59-year-old Caucasian woman with spindle cell malignant mesenchymal sarcoma of the presacral region started a first-line therapy with non-pegylated liposomal doxorubicin and ifosfamide associated with pelvic radiant treatment. After two cycles of chemotherapy plus radiotherapy, a significant pulmonary disease progression was reported. Thus, a second-line therapy with trabectedin was administered. However, after only two cycles of treatment a re-staging computed tomography scan reported further cancer disease progression of the target pulmonary lesions as well as occurrence of new satellite bilateral nodules. Real-time analysis of breath exhaled volatile organic compounds, performed by select ion flow tube mass spectrometry (SIFT-MS) during the follow-up of the patient, showed a specific metabolic pattern not observed in the breath of other soft tissue sarcoma patients who achieved clinical benefit from the treatments. CONCLUSIONS: This case report revealed the importance of the non-invasive real-time volatile organic compounds breath analysis to distinguish individual specific chemo-resistance phenotypes among soft tissue sarcoma patients. Such observation seems to suggest that breath metabolomics may be particularly useful for monitoring cancer disease progression in soft tissue sarcoma patients where only cost-effective diagnostic tools, such as positron emission tomography and computed tomography, are available.


Asunto(s)
Metabolómica , Sarcoma/metabolismo , Sarcoma/patología , Pruebas Respiratorias , Terapia Combinada , Espiración , Femenino , Humanos , Persona de Mediana Edad , Pronóstico , Sarcoma/terapia
5.
J Chromatogr A ; 1536: 122-136, 2018 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-28760605

RESUMEN

The possibility to transfer methods from thermal to differential-flow modulated comprehensive two-dimensional gas chromatographic (GC×GC) platforms opens interesting perspectives for routine analysis of complex samples. Flow modulated platforms avoid the use of cryogenics, thereby simplifying laboratory operations and analyst supervision during intensive analytical sessions. This study evaluates the feasibility of transferring a fingerprinting method capable of classifying and discriminating cocoa samples based on the volatiles fraction composition according to their origin and processing steps. Previously developed principles of GC×GC method translation are applied to an original fingerprinting method, developed for a loop-type thermal modulated GC×GC-MS system, to engineer a method for a reverse-injection differential flow modulated platform (GC×2GC-MS/FID) with a dual-parallel secondary column and dual detection. Effective method translation preserves analytes elution order, 1D resolution, and 2D pattern coherence. The experimental results confirm the feasibility of translating fingerprinting method conditions while preserving the informative power of 2D peak patterns for sample classification and discrimination. Correct translation enables effective transfer of metadata (e.g., compound names and MS fragmentation patterns) by automatic template transformation and matching from the original/reference method to its translated counterpart. Although the adoption of a narrow bore (i.e. 0.1mm dc) column in the first-dimension enabled operation under close-to-optimal conditions with the differential-flow modulation platform, due to the dual-parallel columns in the second-dimension, it resulted in lower overall method sensitivity. Nevertheless, fingerprinting accuracy was preserved and most of the key-aroma compounds and technological markers were effectively mapped, thus limiting the loss of fingerprinting information.


Asunto(s)
Cacao/química , Técnicas de Química Analítica/métodos , Cromatografía de Gases , Tecnología de Alimentos/métodos , Metadatos
6.
J Chromatogr A ; 1480: 70-82, 2017 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-28007300

RESUMEN

The possibility to transfer methods from thermal to differential-flow modulated comprehensive two-dimensional gas chromatographic (GC×GC) platforms is of high interest to improve GC×GC flexibility and increase the compatibility of results from different platforms. The principles of method translation are here applied to an original method, developed for a loop-type thermal modulated GC×GC-MS/FID system, suitable for quali-quantitative screening of suspected fragrance allergens. The analysis conditions were translated to a reverse-injection differential flow modulated platform (GC×2GC-MS/FID) with a dual-parallel secondary column and dual detection. The experimental results, for a model mixture of suspected volatile allergens and for raw fragrance mixtures of different composition, confirmed the feasibility of translating methods by preserving 1D elution order, as well as the relative alignment of resulting 2D peak patterns. A correct translation produced several benefits including an effective transfer of metadata (compound names, MS fragmentation pattern, response factors) by automatic template transformation and matching from the original/reference method to its translated counterpart. The correct translation provided: (a) 2D pattern repeatability, (b) MS fragmentation pattern reliability for identity confirmation, and (c) comparable response factors and quantitation accuracy within a concentration range of three orders of magnitude. The adoption of a narrow bore (i.e. 0.1mm dc) first-dimension column to operate under close-to-optimal conditions with the differential-flow modulation GC×GC platform was also advantageous in halving the total analysis under the translated conditions.


Asunto(s)
Alérgenos/análisis , Cromatografía de Gases/métodos , Metadatos , Perfumes/química , Cromatografía de Gases/instrumentación , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA