Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
ACS Omega ; 9(3): 3262-3275, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38284094

RESUMEN

The ability of the centrifugal Lab-on-a-Disc (LoaD) platform to closely mimic the "on bench" liquid handling steps (laboratory unit operations (LUOs)) such as metering, mixing, and aliquoting supports on-disc automation of bioassay without the need for extensive biological optimization. Thus, well-established bioassays, normally conducted manually using pipettes or using liquid handling robots, can be relatively easily automated in self-contained microfluidic chips suitable for use in point-of-care or point-of-use settings. The LoaD's ease of automation is largely dependent on valves that can control liquid movement on the rotating disc. The optimum valving strategy for a true low-cost and portable device is rotationally actuated valves, which are actuated by changes in the disc spin-speed. However, due to tolerances in disc manufacturing and variations in reagent properties, most of these valving technologies have inherent variation in their actuation spin-speed. Most valves are actuated through stepped increases in disc spin-speed until the motor reaches its maximum speed (rarely more than 6000 rpm). These manufacturing tolerances combined with this "analogue" mechanism of valve actuation limits the number of LUOs that can be placed on-disc. In this work, we present a novel valving mechanism called low-high-low serial dissolvable film (DF) valves. In these valves, a DF membrane is placed in a dead-end pneumatic chamber. Below an actuation spin-speed, the trapped air prevents liquid wetting and dissolving the membrane. Above this spin-speed, the liquid will enter and wet the DF and open the valve. However, as DFs take ∼40 s to dissolve, the membrane can be wetted, and the disc spin-speed reduced before the film opens. Thus, by placing valves in a series, we can govern on which "digital pulse" in spin-speeding a reagent is released; a reservoir with one serial valve will open on the first pulse, a reservoir with two serial valves on the second, and so on. This "digital" flow control mechanism allows the automation of complex assays with high reliability. In this work, we first describe the operation of the valves, outline the theoretical basis for their operation, and support this analysis with an experiment. Next, we demonstrate how these valves can be used to automate the solid-phase extraction of DNA on on-disc LAMP amplification for applications in plant pathogen detection. The disc was successfully used to extract and detect, from a sample lysed off-disc, DNA indicating the presence of thermally inactivated Clavibacter michiganensis ssp. michiganensis (Cmm), a bacterial pathogen on tomato leaf samples.

2.
Anal Chim Acta ; 1288: 342159, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38220291

RESUMEN

BACKGROUND: Biomedical diagnostic and lab automation solutions built on the Lab-on-a-Disc (LoaD) platform has great potential due to their independence from specialised micro-pumps and their ease of integration, through direct pipetting, with manual or automated workflows. However, a challenge for all microfluidic chips is their cost of manufacture when each microfluidic disc must be customized for a specific application. In this paper, we present centrifugal discs with programmable fluidic networks. RESULTS: Based on dissolvable film valves, we present two technologies. The first, based on recently introduced pulse-actuated dissolvable film valves, is a centrifugal disc which, depending on how it is loaded, is configured to perform either six sequential reagent releases through one reaction chamber or three sequential reagent releases through two reaction chambers. In the second approach, we use the previously introduced electronic Lab-on-a-Disc (eLoaD) wireless valve array, which can actuate up to 128 centrifugo-pneumatic dissolvable film valves in a pre-defined sequence. In this approach we present a disc which can deliver any one of 8 reagent washes to any one of four reaction chambers. We use identical discs to demonstrate the first four sequential washes through two reaction chambers and then two sequential washes through four reaction chambers. SIGNIFICANCE: These programmable fluidic networks have the potential to allow a single disc architecture to be applied to multiple different assay types and so can offer a lower-cost and more integrated alternative to the standard combination of micro-titre plate and liquid handling robot. Indeed, it may even be possible to conduct multiple different assays concurrently. This can have the effect of reducing manufacturing costs and streamlining supply-chains and so results in a more accessible diagnostic platform.

3.
Anal Chim Acta ; 1280: 341859, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37858565

RESUMEN

BACKGROUND: Lab-on-a-disc (LoaD) technology has emerged as a transformative approach for point-of-care diagnostics and high-throughput testing. The promise of integrating multiple laboratory functions onto a single integrated platform has significant implications for healthcare, especially in resource-limited settings. However, one of the primary challenges faced in the design and manufacture of LoaD devices is the integration of effective valving mechanisms. These valves are essential for fluid control and routing, but their intricacy often leads to complexities in design and increased vulnerability to failure. This emphasizes the need for improved designs and manufacturing processes without complex, integrated valving mechanisms. (96) RESULTS: We describe a fully automated biological workflow and reagent actuation on a LoaD device without an integrated valving system. The Two Degrees-of-Freedom (2DoF) custom centrifuge alters the centre of rotation, facilitating fluid flow direction changes on the microfluidic platform through a custom programmed interface. A novel 360-degree fluid manipulation approach via secondary planetary gear motion enabled sequential assay reagent actuation without embedded valve triggering, with the addition of infinite incubation times and efficient use of platform realty. The simplified LoaD platform uses clever design, with intermediate flow chambers to avoid cross contamination between reagent steps. Notably, the optimized LoaD platform demonstrated a two-fold DNA yield at higher HEK-293 cell concentrations compared to commercially available spin-column kits. This significantly simplified LoaD platform successfully automated a common, complex workflow without inhibiting DNA purification. (129) SIGNIFICANCE: This system exhibits the clever coupling of both 2DoF and centrifugal microfluidics to create an autonomous testing package capable of eradicating the need for complex valving systems to automate biological workflows on LoaDs. This automated system has outperformed commercially available DNA extraction kits for higher cell counts. The platform's elimination of valve requirements ensures unlimited sample incubation times and enhances reliability, making it a straightforward option for automated biological workflows, particularly in diagnostics. (73).


Asunto(s)
ADN , Técnicas Analíticas Microfluídicas , Humanos , Células HEK293 , Reproducibilidad de los Resultados , Microfluídica , Pruebas en el Punto de Atención , Dispositivos Laboratorio en un Chip
4.
Sci Rep ; 7(1): 1750, 2017 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-28496112

RESUMEN

Diagnosis of seizure disorders such as epilepsy currently relies on clinical examination and electroencephalogram recordings and is associated with substantial mis-diagnosis. The miRNA, miR-134 (MIR134 in humans), has been found to be elevated in brain tissue after experimental status epilepticus and in human epilepsy cells and their detection in biofluids may serve as unique biomarkers. miRNAs from unprocessed human plasma and human cerebrospinal fluid samples were used in a novel electrochemical detection based on electrocatalytic platinum nanoparticles inside a centrifugal microfluidic device where the sandwich assay is formed using an event triggered release system, suitable for the rapid point-of-care detection of low abundance biomarkers of disease. The device has the advantage of controlling the rotation speed of the centrifugal device to pump nanoliter volumes of fluid at a set time and manipulate the transfer of liquids within the device. The centrifugal platform improves reaction rates and yields by proposing efficient mixing strategies to overcome diffusion-limited processes and improve mass transport rates, resulting in reduced hybridization times with a limit of detection of 1 pM target concentration. Plasma and cerebrospinal fluid samples (unprocessed) from patients with epilepsy or who experienced status epilepticus were tested and the catalytic response obtained was in range of the calibration plot. This study demonstrates a rapid and simple detection for epilepsy biomarkers in biofluid.


Asunto(s)
Dispositivos Laboratorio en un Chip , MicroARNs/sangre , MicroARNs/líquido cefalorraquídeo , Nanomedicina Teranóstica/instrumentación , Adulto , Anciano de 80 o más Años , Tampones (Química) , Estudios de Casos y Controles , Catálisis , Electrodos , Epilepsia/sangre , Epilepsia/líquido cefalorraquídeo , Femenino , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Hibridación de Ácido Nucleico , Adulto Joven
5.
Biosens Bioelectron ; 77: 759-66, 2016 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-26513282

RESUMEN

Highly sensitive and label free detection of prostate specific antigen (PSA) still remains a challenge in prostate cancer diagnosis. In this paper, we propose a sensitive electrochemical immunosensor based on electrocatalytic platinum nanoparticles conjugated to a recombinant scFv antibody. Gold disc electrodes functionalised with a l-Cysteine (Cys) self-assembled monolayer (SAM) were used to covalently bind PSA specific monoclonal antibody (anti-PSA) using N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide (EDC/NHS) chemistry. Immunosensing was completed using sandwich-type immunoreaction of the PSA-antigen (1-30 ng/mL) between anti-PSA immobilized on the l-Cys modified electrode using label free electrochemical impedance (EIS) technique. Furthermore, highly specific in-house generated scFv fragments as receptor proteins were utilised for one step site-directed immobilisation on the surface of platinum nanoparticles (PtNPs). To improve the sensitivity of the immunoassay, these scFV labelled electrocatalytic PtNPs were then used for covalent hybridisation to the PSA modified electrode and then applied in a hybridisation assay to determine the concentration of the PSA by measuring the faradaic current associated with reduction of peroxide in solution. Semi-log plots of the PSA concentration vs. faradaic current are linear from 1 to 30 ng/mL and pM concentrations can be detected without the need for molecular, e.g., PCR or NASBA, amplification.


Asunto(s)
Conductometría/instrumentación , Inmunoensayo/instrumentación , Nanopartículas del Metal/química , Nanoconjugados/química , Antígeno Prostático Específico/análisis , Anticuerpos de Cadena Única/química , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/inmunología , Biomarcadores de Tumor/análisis , Catálisis , Galvanoplastia/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Nanopartículas del Metal/ultraestructura , Nanoconjugados/ultraestructura , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Anticuerpos de Cadena Única/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...