RESUMEN
Background: Laparoscopic surgery with pneumoperitoneum increases respiratory system elastance due to the augmented intra-abdominal pressure. We aim to evaluate to which extent positive end-expiratory pressure (PEEP) is able to counteract abdominal hypertension preventing progressive lung collapse and how rib cage elastance influences PEEP effect. Methods: Forty-four Wistar rats were mechanically ventilated and randomly assigned into three groups: control (CTRL), pneumoperitoneum (PPT) and pneumoperitoneum with restricted rib cage (PPT-RC). A pressure-volume (PV) curve followed by a recruitment maneuver and a decremental PEEP trial were performed in all groups. Thereafter, animals were ventilated using PEEP of 3 and 8 cmH2O divided into two subgroups used to evaluate respiratory mechanics or computed tomography (CT) images. In 26 rats, we compared respiratory system elastance (Ers) at the two PEEP levels. In 18 animals, CT images were acquired to calculate total lung volume (TLV), total volume and air volume in six anatomically delimited regions of interest (three along the cephalo-caudal and three along the ventro-dorsal axes). Results: PEEP of minimal Ers was similar in CTRL and PPT groups (3.8 ± 0.45 and 3.5 ± 3.89 cmH2O, respectively) and differed from PPT-RC group (9.8 ± 0.63 cmH2O). Chest restriction determined a right- and downward shift of the PV curve, increased Ers and diminished TLV and lung aeration. Increasing PEEP augmented TLV in CTRL group (11.8 ± 1.3 to 13.6 ± 2 ml, p < 0.05), and relative air content in the apex of PPT group (3.5 ± 1.4 to 4.6 ± 1.4% TLV, p < 0.03) and in the middle zones in PPT-RC group (21.4 ± 1.9 to 25.3 ± 2.1% TLV cephalo-caudally and 18.1 ± 4.3 to 22.0 ± 3.3% TLV ventro-dorsally, p < 0.005). Conclusion: Regional lung recruitment potential during pneumoperitoneum depends on rib cage elastance, reinforcing the concept of PEEP individualization according to the patient's condition.
RESUMEN
Mixtures of anhydrous ethyl alcohol and gasoline substituted for pure gasoline as a fuel in many Brazilian vehicles. Consequently, the concentrations of volatile organic compounds (VOCs) such as ketones, other organic compounds, and particularly aldehydes increased in many Brazilian cities. The current study aims to investigate whether formaldehyde, acetaldehyde, or mixtures of both impair lung function, morphology, inflammatory and redox responses at environmentally relevant concentrations. For such purpose, C57BL/6 mice were exposed to either medical compressed air or to 4 different mixtures of formaldehyde and acetaldehyde. Eight hours later animals were anesthetized, paralyzed and lung mechanics and morphology, inflammatory cells and IL-1ß, KC, TNF-α, IL-6, CCL2, MCP-1 contents, superoxide dismutase and catalalase activities were determined. The extra pulmonary respiratory tract was also analyzed. No differences could be detected between any exposed and control groups. In conclusion, no morpho-functional alterations were detected in exposed mice in relation to the control group.
Asunto(s)
Acetaldehído/toxicidad , Contaminantes Atmosféricos/toxicidad , Formaldehído/toxicidad , Pulmón/efectos de los fármacos , Compuestos Orgánicos Volátiles/toxicidad , Contaminación del Aire , Animales , Fenómenos Biomecánicos , Femenino , Pulmón/patología , Pulmón/fisiopatología , Mediciones del Volumen Pulmonar , Masculino , Ratones Endogámicos C57BL , Modelos Animales , Mucosa Nasal/efectos de los fármacos , Mucosa Nasal/metabolismo , Mucosa Nasal/patología , Estrés Oxidativo/efectos de los fármacos , Estrés Oxidativo/fisiología , Presión , Ventilación Pulmonar , Factores de TiempoRESUMEN
BACKGROUND: A decremental positive end-expiratory pressure (PEEP) trial after full lung recruitment allows for the adjustment of the lowest PEEP that prevents end-expiratory collapse (open-lung PEEP). For a tidal volume (Vt) approaching zero, the PEEP of minimum respiratory system elastance (PEEP(minErs)) is theoretically equal to the pressure at the mathematical inflection point (MIP) of the pressure-volume curve, and seems to correspond to the open-lung PEEP in a decremental PEEP trial. Nevertheless, the PEEP(minErs) is dependent on Vt and decreases as Vt increases. To circumvent this dependency, we proposed the use of a second-order model in which the volume-independent elastance (E1) is used to set open-lung PEEP. METHODS: Pressure-volume curves and a recruitment maneuver followed by decremental PEEP trials, with a Vt of 6 and 12 mL/kg, were performed in 24 Wistar rats with acute lung injury induced by intraperitoneally injected (n = 8) or intratracheally instilled (n = 8) Escherichia coli lipopolysaccharide. In 8 control animals, the anterior chest wall was surgically removed after PEEP trials, and the protocol was repeated. Airway pressure (Paw) and flow (F) were continuously acquired and fitted by the linear single-compartment model (Paw = Rrs·F + Ers·V + PEEP, where Rrs is the resistance of the respiratory system, and V is volume) and the volume-dependent elastance model (Paw = Rrs·F + E1 + E2·V·V + PEEP, where E2·V is the volume-dependent elastance). From each model, PEEPs of minimum Ers and E1 (PEEP(minE1)) were identified and compared with each respective MIP. The accuracy of PEEPminE1 and PEEPminErs in estimating MIP was assessed by bias and precision plots. Comparisons among groups were performed with the unpaired t test whereas a paired t test was used between the control group before and after chest wall removal and within groups at different Vts. All P values were then corrected for multiple comparisons by the Bonferroni procedure. RESULTS: In all experimental groups, PEEPminErs, but not PEEPminE1, tended to decrease as Vt increased. The difference between MIP and PEEPminE1 exhibited a lower bias compared with the difference between MIP and PEEPminErs (P < 0.001). The PEEPminE1 was always significantly higher than the PEEPminErs (7.7 vs 3.8, P < 0.001) and better approached MIP (7.7 vs 7.3 cm H2O with P = 0.04 at low Vt, and 7.8 vs 7.1 cm H2O with P < 0.001 at high Vt). CONCLUSIONS: PEEPminE1 better identifies the open-lung PEEP independently of the adjusted Vt, and may be a practical, more individualized approach for PEEP titration.