Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Europace ; 25(10)2023 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-37789664

RESUMEN

AIMS: Electrophysiological (EP) operations that have traditionally involved long hospital lengths of stay (LOS) are now being undertaken as day case procedures. The coronavirus disease-19 pandemic served as an impetus for many centres to shorten LOS for EP procedures. This survey explores LOS for elective EP procedures in the modern era. METHODS AND RESULTS: An online survey consisting of 27 multiple-choice questions was completed by 245 respondents from 35 countries. With respect to de novo cardiac implantable electronic device (CIED) implantations, day case procedures were reported for 79.5% of implantable loop recorders, 13.3% of pacemakers (PMs), 10.4% of implantable cardioverter defibrillators (ICDs), and 10.2% of cardiac resynchronization therapy (CRT) devices. With respect to CIED generator replacements, day case procedures were reported for 61.7% of PMs, 49.2% of ICDs, and 48.2% of CRT devices. With regard to ablations, day case procedures were reported for 5.7% of atrial fibrillation (AF) ablations, 10.7% of left-sided ablations, and 17.5% of right-sided ablations. A LOS ≥ 2 days for CIED implantation was reported for 47.7% of PM, 54.5% of ICDs, and 56.9% of CRT devices and for 54.5% of AF ablations, 42.2% of right-sided ablations, and 46.1% of left-sided ablations. Reimbursement (43-56%) and bed availability (20-47%) were reported to have no consistent impact on the organization of elective procedures. CONCLUSION: There is a wide variation in the LOS for elective EP procedures. The LOS for some procedures appears disproportionate to their complexity. Neither reimbursement nor bed availability consistently influenced LOS.


Asunto(s)
Fibrilación Atrial , COVID-19 , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Humanos , Terapia de Resincronización Cardíaca/métodos , Tiempo de Internación , COVID-19/epidemiología , Encuestas y Cuestionarios
2.
World J Cardiol ; 15(10): 487-499, 2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37900906

RESUMEN

Cardiomyopathies represent a diverse group of heart muscle diseases with varying etiologies, presenting a diagnostic challenge due to their heterogeneous manifestations. Regular evaluation using cardiac imaging techniques is imperative as symptoms can evolve over time. These imaging approaches are pivotal for accurate diagnosis, treatment planning, and optimizing prognostic outcomes. Among these, cardiovascular magnetic resonance (CMR) stands out for its ability to provide precise anatomical and functional assessments. This manuscript explores the significant contributions of CMR in the diagnosis and management of patients with cardiomyopathies, with special attention to risk stratification. CMR's high spatial resolution and tissue characterization capabilities enable early detection and differentiation of various cardiomyopathy subtypes. Additionally, it offers valuable insights into myocardial fibrosis, tissue viability, and left ventricular function, crucial parameters for risk stratification and predicting adverse cardiac events. By integrating CMR into clinical practice, clinicians can tailor patient-specific treatment plans, implement timely interventions, and optimize long-term prognosis. The non-invasive nature of CMR reduces the need for invasive procedures, minimizing patient discomfort. This review highlights the vital role of CMR in monitoring disease progression, guiding treatment decisions, and identifying potential complications in patients with cardiomyopathies. The utilization of CMR has significantly advanced our understanding and management of these complex cardiac conditions, leading to improved patient outcomes and a more personalized approach to care.

3.
Eur Heart J Digit Health ; 4(1): 43-52, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36743871

RESUMEN

Aims: Remote monitoring (RM) is the standard of care for follow up of patients with cardiac implantable electronic devices. The aim of this study was to compare smartphone-based RM (SM-RM) using patient applications (myMerlinPulse™ app) with traditional bedside monitor RM (BM-RM). Methods and results: The retrospective study included de-identified US patients who received either SM-RM or BM-RM capable of implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators (Abbott, USA). Patients in SM-RM and BM-RM groups were propensity-score matched on age and gender, device type, implant year, and month. Compliance with RM was quantified as the proportion of patients enrolling in the RM system (Merlin.net™) and transmitting data at least once. Connectivity was measured by the median number of days between consecutive transmissions per patient. Of the initial 9714 patients with SM-RM and 26 679 patients with BM-RM, 9397 patients from each group were matched. Remote monitoring compliance was higher in SM-RM; significantly more patients with SM-RM were enrolled in RM compared with BM-RM (94.4 vs. 85.0%, P < 0.001), similar number of patients in the SM-RM group paired their device (95.1 vs. 95.0%, P = 0.77), but more SM-RM patients transmitted at least once (98.1 vs. 94.3%, P < 0.001). Connectivity was significantly higher in the SM-RM, with patients transmitting data every 1.2 (1.1, 1.7) vs. every 1.7 (1.5, 2.0) days with BM-RM (P < 0.001) and remained better over time. Significantly more SM-RM patients utilized patient-initiated transmissions compared with BM-RM (55.6 vs. 28.1%, P < 0.001). Conclusion: In this large real-world study, patients with SM-RM demonstrated improved compliance and connectivity compared with BM-RM.

4.
J Pers Med ; 13(2)2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36836420

RESUMEN

BACKGROUND: One of the reasons that high-frequency jet ventilation (HFJV) is used is due to the near immobility of thoracic structures. However, no study has quantified the movements of cardiac structures during HFJV compared with normal mechanical ventilation. METHODS: After ethical approval and written informed consent, we included 21 patients scheduled for atrial fibrillation ablation in this prospective crossover study. Each patient was ventilated with both normal mechanical ventilation and HFJV. During each ventilation mode, displacements of the cardiac structure were measured by the EnSite Precision mapping system using a catheter placed in the coronary sinus. RESULTS: The median [Q1-Q4] displacement was 2.0 [0.6-2.8] mm during HFJV and 10.5 [9.3-13.0] mm during conventional ventilation (p < 0.000001). CONCLUSION: This study quantifies the minimal movement of cardiac structures during HFJV compared to standard mechanical ventilation.

5.
Europace ; 25(3): 1025-1034, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36635857

RESUMEN

AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data. METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available. Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV. CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants.


Asunto(s)
Cardiomiopatías , Taquicardia Ventricular , Humanos , Bloqueo de Rama , Taquicardia Ventricular/etiología , Taquicardia Ventricular/complicaciones , Ventrículos Cardíacos , Electrocardiografía , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico
7.
Comput Biol Med ; 154: 106604, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36709520

RESUMEN

OBJECTIVE: The aim of this study is to propose a method to reduce the sensitivity of the estimated omnipolar electrogram (oEGM) with respect to the angle of the propagation wavefront. METHODS: A novel configuration of cliques taking into account all four electrodes of a squared cell is proposed. To test this approach, simulations of HD grids of cardiac activations at different propagation angles, conduction velocities, interelectrode distance and electrogram waveforms are considered. RESULTS: The proposed approach successfully provided narrower loops (essentially a straight line) of the electrical field described by the bipole pair with respect to the conventional approach. Estimation of the direction of propagation was improved. Additionally, estimated oEGMs presented larger amplitude, and estimations of the local activation times were more accurate. CONCLUSIONS: A novel method to improve the estimation of oEGMs in HD grid of electrodes is proposed. This approach is superior to the existing methods and avoids pitfalls not yet resolved. RELEVANCE: Robust tools for quantifying the cardiac substrate are crucial to determine with accuracy target ablation sites during an electrophysiological procedure.


Asunto(s)
Electrocardiografía , Corazón , Electrocardiografía/métodos , Corazón/fisiología , Electrodos , Factores de Tiempo
10.
World J Clin Cases ; 10(27): 9556-9572, 2022 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-36186196

RESUMEN

Coronavirus disease 2019 (COVID-19) is known to present with respiratory symptoms, which can lead to severe pneumonia and respiratory failure. However, it can have multisystem complications such as cardiovascular manifestations. The cardiovascular manifestations reported comprise myocarditis, cardiogenic shock, arrhythmias, pulmonary embolism, deep vein embolism, acute heart failure, and myocardial infarction. There is also an indirect impact of the pandemic on the management of cardiovascular care that has been shown clearly in multiple publications. In this review, we summarize the deadly relation of COVID-19 with cardiovascular events and the wider impact on several cardiovascular care areas by the pandemic situation.

11.
Europace ; 24(11): 1834-1843, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-36040858

RESUMEN

Since digital devices are increasingly used in cardiology for assessing cardiac rhythm and detecting arrhythmias, especially atrial fibrillation (AF), our aim was to evaluate the expectations and opinions of healthcare professionals in Europe on reimbursement policies for the use of digital devices (including wearables) in AF and other arrhythmias. An anonymous survey was proposed through announcements on the European Heart Rhythm Association website, social media channels, and mail newsletter. Two hundred and seventeen healthcare professionals participated in the survey: 32.7%, reported regular use of digital devices, 45.2% reported that they sometimes use these tools, 18.6% that they do not use but would like to. Only a minority (3.5%) reported a lack of trust in digital devices. The survey highlighted a general propensity to provide medical consultation for suspected AF or other arrhythmias detected by a consumer-initiated use of digital devices, even if time constraints and reimbursement availability emerged as important elements. More than 85% of respondents agreed that reimbursement should be applied for clinical use of digital devices, also in different settings such as post-stroke, post-cardioversion, post-ablation, and in patients with palpitations or syncope. Finally, 73.6% of respondents confirmed a lack of reimbursement fees in their country for physicians' consultations (tracings interpretation) related to digital devices. Digital devices, including wearables, are increasingly and widely used for assessing cardiac rhythm and detecting AF, but a definition of reimbursement policies for physicians' consultations is needed.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Encuestas de Atención de la Salud , Pautas de la Práctica en Medicina , Resultado del Tratamiento , Encuestas y Cuestionarios
12.
Europace ; 24(10): 1541-1547, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35531864

RESUMEN

There is an increasing pressure on demonstrating the value of medical interventions and medical technologies resulting in the proposal of new approaches for implementation in the daily practice of innovative treatments that might carry a substantial cost. While originally mainly adopted by pharmaceutical companies, in recent years medical technology companies have initiated novel value-based arrangements for using medical devices, in the form of 'outcomes-based contracts', 'performance-based contracts', or 'risk-sharing agreements'. These are all characterized by linking coverage, reimbursement, or payment for the innovative treatment to the attainment of pre-specified clinical outcomes. Risk-sharing agreements have been promoted also in the field of electrophysiology and offer the possibility to demonstrate the value of specific innovative technologies proposed in this rapidly advancing field, while relieving hospitals from taking on the whole financial risk themselves. Physicians deeply involved in the field of devices and technologies for arrhythmia management and invasive electrophysiology need to be prepared for involvement as stakeholders. This may imply engagement in the evaluation of risk-sharing agreements and specifically, in the process of assessment of technology performances or patient outcomes. Scientific Associations may have an important role in promoting the basis for value-based assessments, in promoting educational initiatives to help assess the determinants of the learning curve for innovative treatments, and in promoting large-scale registries for a precise assessment of patient outcomes and of specific technologies' performance.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas , Prorrateo de Riesgo Financiero , Industria Farmacéutica , Humanos
13.
J Clin Med ; 11(3)2022 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-35160027

RESUMEN

BACKGROUND: Atrial anti-tachycardia pacing (A-ATP) of the right atrium (RA) has been shown to decrease the burden of atrial fibrillation (AF) in patients with dual-chamber pacemakers. The aim of this study is to identify the novel predictors of effective A-ATP for terminating AF in patients with AF undergoing catheter ablation. METHODS: This study included 41 consecutive patients undergoing a first ablation procedure for paroxysmal (PAF: n = 21) or persistent (PEF: n = 20) AF. We prospectively evaluated predictors of AF termination after A-ATP. The coefficient of variation (CoV = SD/mean × 100) of the dominant frequencies (DFs) was calculated to evaluate the variability in atrial activation. RESULTS: AF was terminated by A-ATP in 29% of PAF and 5% of PEF patients. In these patients, simultaneous high-rate pacing from the RA and the coronary sinus (CS) terminated AF in 71% of patients, in whom the mean AF cycle length (CL) before A-ATP was longer (214 ± 23 vs. 177 ± 35 ms, p = 0.02) and became slower after A-ATP (234 ± 37 vs. 176 ± 32 ms, p < 0.01), compared to unsuccessful patients. The CoV of the DFs before A-ATP were lower in both RA (6.2 ± 2.0 vs. 15.3 ± 7.9, p = 0.02) and CS (11.0 ± 7.9 vs. 24.3 ± 9.3, p < 0.01) in successful patients. CONCLUSIONS: Simultaneous biatrial A-ATP from the RA and CS could terminate AF in patients with PAF. The predictors for successful termination include longer AF CL and higher AF stability.

14.
Europace ; 24(2): 313-330, Feb. 2022. graf, ilus, tab
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1352856

RESUMEN

Abstract We aim to provide a critical appraisal of basic concepts underlying signal recording and processing technologies applied for (I) atrial fibrillation (AF) mapping to unravel AF mechanisms and/or identifying target sites for AF therapy and (ii) AF detection, to optimize usage of technologies, stimulate research aimed at closing knowledge gaps, and developing ideal AF recording and processing technologies. Recording and processing techniques for assessment of electrical activity during AF essential for diagnosis and guiding ablative therapy including body surface electrocardiograms (ECG) and endo- or epicardial electrograms (EGM) are evaluated. Discussion of (I) differences in uni-, bi-, and multi-polar (omnipolar/Laplacian) recording modes, (ii) impact of recording technologies on EGM morphology, (iii) global or local mapping using various types of EGM involving signal processing techniques including isochronal-, voltage- fractionation-, dipole density-, and rotor mapping, enabling derivation of parameters like atrial rate, entropy, conduction velocity/direction, (iv) value of epicardial and optical mapping, (v) AF detection by cardiac implantable electronic devices containing various detection algorithms applicable to stored EGMs, (vi) contribution of machine learning (ML) to further improvement of signals processing technologies. Recording and processing of EGM (or ECG) are the cornerstones of (body surface) mapping of AF. Currently available AF recording and processing technologies are mainly restricted to specific applications or have technological limitations. Improvements in AF mapping by obtaining highest fidelity source signals (e. g. catheter­electrode combinations) for signal processing (e. g. filtering, digitization, and noise elimination) is of utmost importance. Novel acquisition instruments (multi-polar catheters combined with improved physical modelling and ML techniques) will enable enhanced and automated interpretation of EGM recordings in the near future.


Asunto(s)
Fibrilación Atrial , Electrocardiografía , Aprendizaje Automático , Frecuencia Cardíaca
15.
Europace ; 24(2): 285-295, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-34491328

RESUMEN

AIMS: In arrhythmogenic cardiomyopathy (ACM), sustained ventricular tachycardia (VT) typically displays a left bundle branch block (LBBB) morphology while a right bundle branch block (RBBB) morphology is rare. The present study assesses the VT morphology in ACM patients with sustained VT and their clinical and genetic characteristics. METHODS AND RESULTS: Twenty-six centres from 11 European countries provided information on 954 ACM patients who had ≥1 episode of sustained VT spontaneously documented during patients' clinical course. Arrhythmogenic cardiomyopathy was defined according to the 2010 Task Force Criteria, and VT morphology according to the QRS pattern in V1. Overall, 882 (92.5%) patients displayed LBBB-VT alone and 72 (7.5%) RBBB-VT [alone in 42 (4.4%) or in combination with LBBB-VT in 30 (3.1%)]. Male sex prevalence was 79.3%, 88.1%, and 56.7% in the LBBB-VT, RBBB-VT, and LBBB + RBBB-VT groups, respectively (P = 0.007). First RBBB-VT occurred 5 years after the first LBBB-VT (46.5 ± 14.4 vs 41.1 ± 15.8 years, P = 0.011). An implanted cardioverter-defibrillator was more frequently implanted in the RBBB-VT (92.9%) and the LBBB + RBBB-VT groups (90%) than in the LBBB-VT group (68.1%) (P < 0.001). Mutations in PKP2 predominated in the LBBB-VT (65.2%) and the LBBB + RBBB-VT (41.7%) groups while DSP mutations predominated in the RBBB-VT group (45.5%). By multivariable analysis, female sex was associated with LBBB + RBBB-VT (P = 0.011) while DSP mutations were associated with RBBB-VT (P < 0.001). After a median follow-up of 103 (51-185) months, death occurred in 106 (11.1%) patients with no intergroup difference (P = 0.176). CONCLUSION: RBBB-VT accounts for a significant proportion of sustained VTs in ACM. Sex and type of pathogenic mutations were associated with VT type, female sex with LBBB + RBBB-VT, and DSP mutation with RBBB-VT.


Asunto(s)
Cardiomiopatías , Taquicardia Ventricular , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/epidemiología , Bloqueo de Rama/terapia , Cardiomiopatías/complicaciones , Cardiomiopatías/epidemiología , Cardiomiopatías/genética , Electrocardiografía , Femenino , Humanos , Masculino , Prevalencia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/genética
16.
Europace ; 24(2): 313-330, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-34878119

RESUMEN

We aim to provide a critical appraisal of basic concepts underlying signal recording and processing technologies applied for (i) atrial fibrillation (AF) mapping to unravel AF mechanisms and/or identifying target sites for AF therapy and (ii) AF detection, to optimize usage of technologies, stimulate research aimed at closing knowledge gaps, and developing ideal AF recording and processing technologies. Recording and processing techniques for assessment of electrical activity during AF essential for diagnosis and guiding ablative therapy including body surface electrocardiograms (ECG) and endo- or epicardial electrograms (EGM) are evaluated. Discussion of (i) differences in uni-, bi-, and multi-polar (omnipolar/Laplacian) recording modes, (ii) impact of recording technologies on EGM morphology, (iii) global or local mapping using various types of EGM involving signal processing techniques including isochronal-, voltage- fractionation-, dipole density-, and rotor mapping, enabling derivation of parameters like atrial rate, entropy, conduction velocity/direction, (iv) value of epicardial and optical mapping, (v) AF detection by cardiac implantable electronic devices containing various detection algorithms applicable to stored EGMs, (vi) contribution of machine learning (ML) to further improvement of signals processing technologies. Recording and processing of EGM (or ECG) are the cornerstones of (body surface) mapping of AF. Currently available AF recording and processing technologies are mainly restricted to specific applications or have technological limitations. Improvements in AF mapping by obtaining highest fidelity source signals (e.g. catheter-electrode combinations) for signal processing (e.g. filtering, digitization, and noise elimination) is of utmost importance. Novel acquisition instruments (multi-polar catheters combined with improved physical modelling and ML techniques) will enable enhanced and automated interpretation of EGM recordings in the near future.


Asunto(s)
Fibrilación Atrial , Cardiología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Mapeo del Potencial de Superficie Corporal , Atrios Cardíacos , Humanos , América Latina
17.
Eur Heart J Digit Health ; 3(3): 341-358, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36712155

RESUMEN

The role of subclinical atrial fibrillation as a cause of cryptogenic stroke is unambiguously established. Long-term electrocardiogram (ECG) monitoring remains the sole method for determining its presence following a negative initial workup. This position paper of the European Society of Cardiology Working Group on e-Cardiology first presents the definition, epidemiology, and clinical impact of cryptogenic ischaemic stroke, as well as its aetiopathogenic association with occult atrial fibrillation. Then, classification methods for ischaemic stroke will be discussed, along with their value in providing meaningful guidance for further diagnostic efforts, given disappointing findings of studies based on the embolic stroke of unknown significance construct. Patient selection criteria for long-term ECG monitoring, crucial for determining pre-test probability of subclinical atrial fibrillation, will also be discussed. Subsequently, the two major classes of long-term ECG monitoring tools (non-invasive and invasive) will be presented, with a discussion of each method's pitfalls and related algorithms to improve diagnostic yield and accuracy. Although novel mobile health (mHealth) devices, including smartphones and smartwatches, have dramatically increased atrial fibrillation detection post ischaemic stroke, the latest evidence appears to favour implantable cardiac monitors as the modality of choice; however, the answer to whether they should constitute the initial diagnostic choice for all cryptogenic stroke patients remains elusive. Finally, institutional and organizational issues, such as reimbursement, responsibility for patient management, data ownership, and handling will be briefly touched upon, despite the fact that guidance remains scarce and widespread clinical application and experience are the most likely sources for definite answers.

18.
Circ Genom Precis Med ; 14(5): e003222, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34461752

RESUMEN

BACKGROUND: Brugada syndrome (BrS) is associated with mutations in the cardiac sodium channel gene, SCN5A. However, genetic studies of patients with BrS with arrhythmic events have been limited. We sought to compare various clinical, ECG, and electrophysiological parameters according to SCN5A genotype in a large cohort of BrS probands with first arrhythmic event. METHODS: Survey on Arrhythmic Events in Brugada Syndrome is a survey of 10 Western and 4 Asian countries, gathering 678 patients with BrS with first arrhythmic event. Only probands were included, and SCN5A genotype adjudicated. Patients without appropriate genetic data were excluded. Associations of genotype with clinical features were analyzed. RESULTS: The study group comprised 392 probands: 92 (23.5%) SCN5A+(44 pathogenic/likely pathogenic [P/LP] and 48 variants of unknown significance) and 300 (76.5%) SCN5A-.SCN5A missense variants and the patients hosting them were similar regardless of adjudication. A higher proportion of patients with P/LP were pediatric (<16 years) compared with SCN5A- (11.4% versus 3%, P=0.023). The proportion of females was higher among patients with P/LP compared with SCN5A- (18.2% versus 6.3%, P=0.013). P/LP probands were more likely to have a family history of sudden cardiac death compared with SCN5A- (41.9% versus 16.8%, P<0.001). A higher proportion of patients with P/LP were White compared with SCN5A- (87.5% versus 47%, P<0.001). Ethnicity (odds ratio, 5.41 [2.8-11.19], P<0.001) and family history of sudden cardiac death (odds ratio, 2.73 [1.28-5.82], P=0.009) were independent variables associated with P/LP genotype following logistic regression. CONCLUSIONS: The genetic basis of BrS has a complex relationship with gender, ethnicity, and age. Probands hosting a P/LP variant tended to experience their first arrhythmic event at a younger age and to have events triggered by fever compared with patients with SCN5A-. In addition, they were more likely to be White and to have family history of sudden cardiac death. Among females, a P/LP variant suggests an increased risk of being symptomatic. This association should be further studied on an ethnically specific basis in large prospectively collected international cohorts.


Asunto(s)
Síndrome de Brugada/genética , Síndrome de Brugada/fisiopatología , Electrocardiografía , Genotipo , Canal de Sodio Activado por Voltaje NAV1.5/genética , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores Sexuales
19.
Acta Cardiol ; 76(4): 431-439, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33406996

RESUMEN

BACKGROUND: Studies on the use of non-vitamin K antagonist oral anticoagulants in unselected patients with atrial fibrillation (AF) show that clinical characteristics and dosing practices differ per region, but lack data on edoxaban. METHODS: With data from Edoxaban Treatment in routiNe clinical prActice for patients with AF in Europe (ETNA-AF-Europe), a large prospective observational study, we compared clinical characteristics (including the dose reduction criteria for edoxaban: creatinine clearance 15-50 mL/min, weight ≤60 kg, and/or use of strong p-glycoprotein inhibitors) of patients from Belgium and the Netherlands (BeNe) with those from other European countries (OEC). RESULTS: Of all 13,639 patients in ETNA-AF-Europe, 2579 were from BeNe. BeNe patients were younger than OEC patients (mean age: 72.3 vs 73.9 years), and had lower CHA2DS2-VASc (mean: 2.8 vs 3.2) and HAS-BLED scores (mean: 2.4 vs 2.6). Patients from BeNe less often had hypertension (61.6% vs 80.4%), and/or diabetes mellitus (17.3% vs 23.1%) than patients from OEC. Moreover, relatively fewer patients in BeNe were prescribed the reduced dose of 30 mg edoxaban (14.8%) than in OEC (25.4%). Overall, edoxaban was dosed according to label in 83.1% of patients. Yet, 30 mg edoxaban was prescribed in the absence of any dose reduction criteria in 36.9% of 30 mg users (5.5% of all patients) in BeNe compared with 35.5% (9.0% of all patients) in OEC. CONCLUSION: There were several notable differences between BeNe and OEC regarding clinical characteristics and dosing practices in patients prescribed edoxaban, which are relevant for the local implementation of dose evaluation and optimisation. TRIAL REGISTRATION: NCT02944019; Date of registration: October 24, 2016.


Asunto(s)
Fibrilación Atrial , Inhibidores del Factor Xa/uso terapéutico , Piridinas/uso terapéutico , Tiazoles/uso terapéutico , Anciano , Anticoagulantes , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Bélgica/epidemiología , Europa (Continente)/epidemiología , Humanos , Países Bajos/epidemiología , Estudios Prospectivos , Resultado del Tratamiento
20.
Circulation ; 143(14): 1359-1373, 2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33401956

RESUMEN

BACKGROUND: Left ventricular (LV) scar on late gadolinium enhancement (LGE) cardiac magnetic resonance has been correlated with life-threatening arrhythmic events in patients with apparently idiopathic ventricular arrhythmias (VAs). We investigated the prognostic significance of a specific LV-LGE phenotype characterized by a ringlike pattern of fibrosis. METHODS: A total of 686 patients with apparently idiopathic nonsustained VA underwent contrast-enhanced cardiac magnetic resonance. A ringlike pattern of LV scar was defined as LV subepicardial/midmyocardial LGE involving at least 3 contiguous segments in the same short-axis slice. The end point of the study was time to the composite outcome of all-cause death, resuscitated cardiac arrest because of ventricular fibrillation or hemodynamically unstable ventricular tachycardia and appropriate implantable cardioverter defibrillator therapy. RESULTS: A total of 28 patients (4%) had a ringlike pattern of scar (group A), 78 (11%) had a non-ringlike pattern (group B), and 580 (85%) had normal cardiac magnetic resonance with no LGE (group C). Group A patients were younger compared with groups B and C (median age, 40 vs 52 vs 45 years; P<0.01), more frequently men (96% vs 82% vs 55%; P<0.01), with a higher prevalence of family history of sudden cardiac death or cardiomyopathy (39% vs 14% vs 6%; P<0.01) and more frequent history of unexplained syncope (18% vs 9% vs 3%; P<0.01). All patients in group A showed VA with a right bundle-branch block morphology versus 69% in group B and 21% in group C (P<0.01). Multifocal VAs were observed in 46% of group A patients compared with 26% of group B and 4% of group C (P<0.01). After a median follow-up of 61 months (range, 34-84 months), the composite outcome occurred in 14 patients (50.0%) in group A versus 15 (19.0%) in group B and 2 (0.3%) in group C (P<0.01). After multivariable adjustment, the presence of LGE with ringlike pattern remained independently associated with increased risk of the composite end point (hazard ratio, 68.98 [95% CI, 14.67-324.39], P<0.01). CONCLUSIONS: In patients with apparently idiopathic nonsustained VA, nonischemic LV scar with a ringlike pattern is associated with malignant arrhythmic events.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Ventrículos Cardíacos/fisiopatología , Adulto , Arritmias Cardíacas/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Análisis de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...