Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Expert Rev Med Devices ; 20(6): 493-503, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37128658

RESUMEN

Atrial fibrillation is the most common arrythmia and it is linked to an increased risk of stroke. Even if anticoagulation therapy reduces the rate of stroke the benefits of this therapy have to be balanced with the increased risk of hemorrhagic event. Left atrial appendage closure is a valid alternative to long-term anticoagulation in patients with atrial fibrillation and high hemorrhagic risk. Actually new devices with different features have been tested and introduced progressively in the clinical practice. Improvements in preprocedural imaging evaluation and the learning curve of the operators led to percutaneous left atrial appendage closure a safe and effective procedure. A good knowledge of different devices and the technique of implant is necessary for optimization percutaneous left atrial appendage closure and the reduction of complications during the acute phase and follow up.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Anticoagulantes/uso terapéutico , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Resultado del Tratamiento , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Hemorragia/inducido químicamente , Hemorragia/complicaciones , Cateterismo Cardíaco
2.
J Cardiovasc Med (Hagerstown) ; 24(3): 191-199, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36753726

RESUMEN

AIMS: To assess the characteristics of left atrial appendage (LAA) stump and left atrial (LA) volume after standalone totally thoracoscopic LAA exclusion in 40 patients with nonvalvular atrial fibrillation (NVAF) and contraindications to oral anticoagulation (OAC), using cardiac computed tomography (CCT) and transoesophageal echocardiography (TOE). METHODS: Using CCT and TOE, we evaluated correct AtriClip Pro II positioning, the presence and characteristics of the LAA stump and the postprocedural LA volume, at 3 months' follow-up. Stump depth was measured with both CCT and TOE using a new method, based on left circumflex artery (LCX) course. RESULTS: After placement of AtriClip, all 40 patients discontinued OAC, and no stroke occurred. LAA exclusion was achieved in 40/40 patients at 3 months' follow-up. LAA stump (depth <10 mm in 12/18 stump, 67%) was observed in 18 patients. The overall (LA + LAA) volume and isolated LA volume were statistically different when comparing cases with and without LAA stump (P < 0.02). LAA ostium dimensions (perimeter and area) and LAA volume correlate with stump depth (P < 0.02). There was a high correlation between CCT and TOE in stump identification and depth measurement (P < 0.02). Compared with the baseline, CCT LA volume increased (P < 0.01) at 3 months' follow-up. CONCLUSION: Preprocedural and postprocedural CCT and TOE are useful and comparable in patients undergoing standalone totally thoracoscopic exclusion of LAA, because these imaging methods can identify anatomical LAA and LA characteristics predisposing for a postprocedural residual stump.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ecocardiografía Transesofágica , Accidente Cerebrovascular/etiología
3.
Medicina (Kaunas) ; 59(2)2023 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-36837606

RESUMEN

Electrical storm is a medical emergency characterized by ventricular arrythmia recurrence that can lead to hemodynamic instability. The incidence of this clinical condition is rising, mainly in implantable cardioverter defibrillator patients, and its prognosis is often poor. Early acknowledgment, management and treatment have a key role in reducing mortality in the acute phase and improving the quality of life of these patients. In an emergency setting, several measures can be employed. Anti-arrhythmic drugs, based on the underlying disease, are often the first step to control the arrhythmic burden; besides that, new therapeutic strategies have been developed with high efficacy, such as deep sedation, early catheter ablation, neuraxial modulation and mechanical hemodynamic support. The aim of this review is to provide practical indications for the management of electrical storm in acute settings.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Humanos , Calidad de Vida , Arritmias Cardíacas , Antiarrítmicos/uso terapéutico , Pronóstico
4.
J Clin Med ; 11(21)2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36362719

RESUMEN

BACKGROUND: Left atrial appendage occlusion is an increasingly proposed treatment for patients with atrial fibrillation and poor tolerance to anticoagulants. All endovascular devices require antithrombotic therapy. Anatomical and clinical variables predisposing to device-related thrombosis, as well as post-procedural peri-device leaks, could mandate the continuation or reintroduction of aggressive antithrombotic treatment. Because of the absence of foreign material inside the heart, epicardial appendage closure possibly does not necessitate antithrombotic therapy, but data of large series are missing. METHODS: Multidisciplinary team evaluation for standalone totally thoracoscopic epicardial appendage closure was done in 180 consecutive patients with atrial fibrillation and poor tolerance to antithrombotic therapy. One hundred and fifty-two patients consented (male 66.1%, mean age 76.1 ± 7.4, CHA2DS2VASc mean 5.3 ± 1.6, HASBLED mean 3.8 ± 1.1). Indications were cerebral hemorrhage (48%), gastro-intestinal bleeding (33.3%), and other bleeding (20.7%). No antithrombotic therapy was prescribed from the day of surgery to the latest follow up. RESULTS: Procedural success was 98.7%. At a mean follow up of 38.2 ± 18.8 months, cardioembolic and bleeding events were 1.3% and 0.6%, respectively. Among patients with a history of blood transfusions (41.1%), none needed further transfusions or treatment post procedure. CONCLUSION: Epicardial appendage occlusion without any antithrombotic therapy appears to be safe and effective. This strategy could be advised when minimization of bleeding risk concomitant to stroke prevention is needed.

5.
Radiol Med ; 125(11): 1200-1207, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32970273

RESUMEN

Cardiovascular diseases are still among the first causes of death worldwide with a huge impact on healthcare systems. Within these conditions, the correct diagnosis of coronary artery disease with the most appropriate imaging-based evaluations is of utmost importance. The sustainability of the healthcare systems, considering the high economic burden of modern cardiac imaging equipments, makes cost-effective analysis an important tool, currently used for weighing different costs and health outcomes, when policy makers have to allocate funds and to prioritize interventions, getting the most out of their financial resources. This review aims at evaluating cost-effective analysis in the more recent literature, focused on the role of Calcium Score, coronary computed tomography angiography and cardiac magnetic resonance.


Asunto(s)
Técnicas de Imagen Cardíaca/economía , Angiografía por Tomografía Computarizada/economía , Angiografía Coronaria/economía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen por Resonancia Magnética/economía , Calcificación Vascular/diagnóstico por imagen , Análisis Costo-Beneficio , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
6.
Radiol Med ; 123(12): 904-909, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30084107

RESUMEN

PURPOSE: To evaluate diagnostic accuracy and to perform an activity-based cost analysis of contrast-enhanced ultrasonography (CEUS) compared to computed tomography (CT) during annual surveillance after abdominal aortic aneurysm repair with endovascular procedure (EVAR). MATERIALS AND METHODS: This retrospective study included 137 patients in post-EVAR follow-up over a 6-year period (average post-operatory follow-up without aneurysm sac volumetric reduction). Sensitivity, specificity, positive predictive values, negative predictive values and accuracy were considered for CEUS using CT angiography (CTA) as reference standard. An activity-based cost analysis was performed to evaluate potential savings due to the introduction of CEUS as an alternative to CT, after the first year of postoperative negative controls. RESULTS: CEUS reported accuracy, sensitivity, specificity, positive predictive values, negative predictive values of 97.4, 96, 100, 100 and 93.1% in the detection and characterization of endoleaks. CEUS cost was € 84.7, and CTA cost was € 157.77, with a differential cost of € 73.07; using CEUS as an alternative to CT allowed a potential saving of 50.052,95 € during follow-up. CONCLUSIONS: CEUS is an accurate and cheap imaging method in post-EVAR follow-up patients, and it could be considered as a valid alternative to CTA, after the first year of negative controls, reducing the number of unnecessary CT examinations.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Angiografía por Tomografía Computarizada/economía , Angiografía por Tomografía Computarizada/métodos , Procedimientos Endovasculares , Ultrasonografía/economía , Ultrasonografía/métodos , Anciano , Anciano de 80 o más Años , Medios de Contraste , Análisis Costo-Beneficio , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sensibilidad y Especificidad
7.
Radiol Med ; 121(1): 12-8, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26210815

RESUMEN

PURPOSE: To establish the appropriate number of Cardiac-CT and Cardio-MR examinations, to determine an economically justified and sustainable investment in these two technologies, for an exclusive cardiologic use. MATERIALS AND METHODS: From July 2013 to July 2014, through a survey in four different Italian Departments of Radiology, data on the costs of Cardiac-CT and Cardiac-MR examinations were collected. For the evaluation of the costs of examinations, it was used an analytical accounting system, considering only the direct costs (consumables, health personnel work time, equipment amortization/maintenance) and other costs (utilities, services, etc.). Indirect costs (general costs) were not assessed. It was made a simulation, assuming an exclusive use of the CT and MR equipments for Cardiac-CT and Cardiac-MR examinations, calculating the annual number necessary to arrive at the Break Even Point (BEP: the point at which cost or expenses and revenue are equal). RESULTS: On the basis of the CT costs, in order to reach the BEP, performing only Cardiac-CT examinations, an average of 2641-2752 examinations/year is needed. The annual time commitment of the Medical Professional to ensure the number of examinations to reach the BEP is 2625-2750 h/year, equivalent to two Medical Doctors in a Cardiology Department. The recent Cardiac-CT Italian Registry, in the period January-June 2011, reports a number of examinations of 3455 patients in 47 different Centers, distributed throughout the whole national territory. With regard to MR, in order to reach the BEP, performing only Cardiac-MR examinations, an average of 2435-3123 examinations/year is needed. The annual time commitment of the Medical Professional to ensure the number of examinations to reach the BEP is 2437-3125 h/year, equivalent to two Medical Doctors in a Cardiology Department. The recent Cardiac-MR Italian Registry reports a number of examinations of 3776 patients in 40 Centers, distributed throughout the whole national territory. CONCLUSION: This research has shown that, only on the basis of costs, currently in Italy is anti-economic an exclusive use of CT or MR equipment for cardiac exams, unless it's not decided, regardless of the recent guidelines and clinical indications, to submit all patients with cardiac diseases (diseases of the coronary arteries and cardiomyopathies) to Cardiac-CT and Cardiac-MR examinations. This might likely to increase both the inappropriate examinations and either health spending and in the case of CT with important repercussions, in terms of radio-exposure, subject to forensic procedures.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Costos y Análisis de Costo , Imagen por Resonancia Magnética/economía , Imagen por Resonancia Magnética/estadística & datos numéricos , Tomografía Computarizada por Rayos X/economía , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Enfermedades Cardiovasculares/diagnóstico por imagen , Humanos , Italia , Sistema de Registros , Encuestas y Cuestionarios
9.
IEEE Trans Med Imaging ; 33(2): 566-76, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24239989

RESUMEN

This work presents the results of a new tool for 3-D segmentation, quantification and visualization of cardiac left atrium fibrosis, based on late gadolinium enhancement magnetic resonance imaging (LGE-MRI), for stratifying patients with atrial fibrillation (AF) that are candidates for radio-frequency catheter ablation. In this study 10 consecutive patients suffering AF with different grades of atrial fibrosis were considered. LGE-MRI and magnetic resonance angiography (MRA) images were used to detect and quantify fibrosis of the left atrium using a threshold and 2-D skeleton based approach. Quantification and 3-D volumetric views of atrial fibrosis were compared with quantification and 3-D bipolar voltage maps measured with an electro-anatomical mapping (EAM) system, the clinical reference standard technique for atrial substrate characterization. Segmentation and quantification of fibrosis areas proved to be clinically reliable among all different fibrosis stages. The proposed tool obtains discrepancies in fibrosis quantification less than 4% from EAM results and yields accurate 3-D volumetric views of fibrosis of left atrium. The novel 3-D visualization and quantification tool based on LGE-MRI allows detection of cardiac left atrium fibrosis areas. This noninvasive method provides a clinical alternative to EAM systems for quantification and localization of atrial fibrosis.


Asunto(s)
Fibrosis/patología , Gadolinio , Atrios Cardíacos/patología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Humanos
10.
Radiol Med ; 119(8): 595-600, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24297596

RESUMEN

PURPOSE: This study was done to identify left atrial fibrosis in a group of consecutive patients with atrial fibrillation (AF) candidate for percutaneous radiofrequency catheter ablation (RFCA) by using a late-enhancement magnetic resonance (LE-MR) sequence, and to validate the technique by comparison with electroanatomical mapping (EAM). MATERIALS AND METHODS: We enrolled 37 patients (29 males; mean age, 61 years) candidate for percutaneous RFCA of AF, who were studied with LE-MR and EAM. To identify left AF we used a three-dimensional LE sequence with cardiac gating and respiratory navigator. The EAM study involved the acquisition of 200 points in the left atrium (LA). The LA was divided into seven segments (pulmonary vein antra, floor, anterior wall, posterior wall-roof). Two blinded radiologists assessed the presence of fibrosis (area of hyperintense signal), reaching a consensus in discordant cases. Inter-observer variability was also evaluated to estimate the reproducibility of the method. We analysed the anatomical agreement between the results obtained with LE-MR imaging and EAM. RESULTS: Five patients were excluded because of to poor image quality. As for the other 32 patients, inter-observer agreement was good [Cohen's kappa κ = 0.72 with 95 % confidence interval (CI) of 0.55, 0.89]. In the classification of LA segments affected by fibrosis, LE-MR had a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 66 % (95 % CI 53.7 %, 77.2 %); 87 % (95 % CI 80.9 %, 91.9 %); 69 % (95 % CI 56.5 %, 80.1 %); 85.5 % (95 % CI 79.1 %, 90.6 %) and 81 % (95 % CU 75.1 %, 85.7 %). CONCLUSIONS: Despite the small size of the sample studied, the LE-MR sequence proved more useful for excluding the presence of AF than for confirming its existence. Identification of AF prior to RFCA is paramount to select those patients who are truly amenable to the ablation procedure, which is expensive and not entirely free of risks.


Asunto(s)
Atrios Cardíacos/patología , Aumento de la Imagen , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Femenino , Fibrosis/diagnóstico , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Factores de Tiempo
11.
J Cardiovasc Med (Hagerstown) ; 12(12): 885-6, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22011555

RESUMEN

Cardiac lipomas are extremely rare neoplasms. We report the case of a 72-year-old woman with an incidental finding of a cardiac mass.


Asunto(s)
Atrios Cardíacos/patología , Neoplasias Cardíacas/diagnóstico , Lipoma/diagnóstico , Anciano , Diagnóstico Diferencial , Femenino , Humanos , Hallazgos Incidentales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...