Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 28(Pt 2): 410-418, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33650552

RESUMEN

It has been shown previously both in vitro and in vivo that microbeam irradiation (MBI) can control malignant tumour cells more effectively than the clinically established concepts of broad beam irradiation. With the aim to extend the international capacity for microbeam research, the first MBI experiment at the biomedical beamline SYRMEP of the Italian synchrotron facility ELETTRA has been conducted. Using a multislit collimator produced by the company TECOMET, arrays of quasi-parallel microbeams were successfully generated with a beam width of 50 µm and a centre-to-centre distance of 400 µm. Murine melanoma cell cultures were irradiated with a target dose of approximately 65 Gy at a mean photon energy of ∼30 keV with a dose rate of 70 Gy s-1 and a peak-to-valley dose of ∼123. This work demonstrated a melanoma cell reduction of approximately 80% after MBI. It is suggested that, while a high energy is essential to achieve high dose rates in order to deposit high treatment doses in a short time in a deep-seated target, for in vitro studies and for the treatment of superficial tumours a spectrum in the lower energy range might be equally suitable or even advantageous.


Asunto(s)
Fotones , Sincrotrones , Animales , Ratones , Método de Montecarlo
2.
Radiat Prot Dosimetry ; 163(2): 141-7, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24757175

RESUMEN

The authors examine the radiation field produced in the vicinity of the main beam dump of the FERMI free-electron laser under the impact of a 1.4-GeV electron beam. Electromagnetic and neutron dose rates are calculated with the Fluka Monte Carlo code and compared with ionisation chamber and superheated drop detector measurements in various positions around the dump. Experimental data and simulation results are in good agreement with a maximum deviation of 25 % in a single location.


Asunto(s)
Electrones , Rayos Láser , Modelos Estadísticos , Aceleradores de Partículas/instrumentación , Radiometría/métodos , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Método de Montecarlo , Dosis de Radiación , Dispersión de Radiación
3.
Radiology ; 259(3): 684-94, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21436089

RESUMEN

PURPOSE: To prospectively evaluate the diagnostic contribution of mammography with synchrotron radiation in patients with questionable or suspicious breast abnormalities identified at combined digital mammography (DM) and ultrasonography (US). MATERIALS AND METHODS: The ethics committee approved this prospective study, and written informed consent was obtained from all patients. Mammography with synchrotron radiation was performed with a phase-detection technique at a synchrotron radiation laboratory. Forty-nine women who met at least one of the inclusion criteria (palpable mass, focal asymmetry, architectural distortion, or equivocal or suspicious mass at DM; none clarified at US) were enrolled. Forty-seven women (mean age, 57.8 years ± 8.8 [standard deviation]; age range, 43-78 years) completed the study protocol, which involved biopsy or follow-up for 1 year as the reference standard. Breast Imaging Reporting and Data System (BI-RADS) scores of 1-3 were considered to indicate a negative result, while scores 4-5 were considered to indicate a positive result. The visibility of breast abnormalities and the glandular parenchymal structure at DM and at mammography with synchrotron radiation was compared by using the Wilcoxon signed rank test. RESULTS: In 29 of the 31 patients with a final diagnosis of benign entity, mammography with synchrotron radiation yielded BI-RADS scores of 1-3. In 13 of the remaining 16 patients with a final diagnosis of malignancy, mammography with synchrotron radiation yielded BI-RADS scores of 4-5. Therefore, a sensitivity of 81% (13 of 16 patients) and a specificity of 94% (29 of 31 patients) were achieved with use of the described BI-RADS dichotomization system. CONCLUSION: These study results suggest that mammography with synchrotron radiation can be used to clarify cases of questionable or suspicious breast abnormalities identified at DM. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11100745/-/DC1.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Sincrotrones , Adulto , Anciano , Biopsia , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Sensibilidad y Especificidad , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...