Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Open Respir Arch ; 5(1): 100216, 2023.
Artículo en Español | MEDLINE | ID: mdl-37497247

RESUMEN

The 55th SEPAR Congress was held in Pamplona from 2 to 4 of June 2022. Once again, it was the referral scientific meeting for specialists in pulmonology, thoracic surgery, nursing, physiotherapy, paediatric respiratory diseases and other disciplines involved in respiratory care. The Spanish Society of Pulmonology and Thoracic Surgery showed its national and international leadership in the management of respiratory diseases, which was reflected in a program with an excellent content and a high scientific level. In this review, we offer a summary of some notable aspects covered in six selected areas of interest: pulmonary vascular diseases, non-invasive mechanical ventilation and sleep disorders, asthma, chronic obstructive pulmonary disease (COPD), interstitial lung diseases (ILD), and interventional pulmonolgy and lung transplant.

2.
Respiration ; 93(3): 162-169, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28088804

RESUMEN

BACKGROUND: Polygraphy (PG) remains the standard method of assessing noninvasive ventilation (NIV) effectiveness. Built-in software (BIS) of recent NIV equipment provides estimates of some ventilator parameters, but their usefulness is unclear. OBJECTIVES: To assess the reliability of BIS compared with PG in a cohort of obesity hypoventilation syndrome (OHS) patients on NIV. METHODS: Thirty stable OHS patients on NIV were evaluated in an outpatient setting with simultaneous PG and BIS recordings. The automated apnea-hypopnea event index (EIAUT) provided by Rescan and manual scoring based on available traces obtained from the software (EIBIS) were compared with manual PG scoring (EIPG). Each manual scoring was separately performed by 2 trained operators. Agreement between the 2 operators was assessed using the kappa coefficient. Pearson correlation and Bland-Altman plots were used to evaluate agreement between EIAUT, EIBIS, and EIPG. RESULTS: Twenty-six cases were valid for analysis (age ±61 years, 17 men). All patients were ventilated in the spontaneous/timed mode (mean inspiratory positive airway pressure 17 ± 3 cm H2O, mean expiratory positive airway pressure 10 ± 3 cm H2O). Cohen's kappa agreement between the operators was 0.7 for EIBIS and 0.84 for EIPG. EIBIS showed good correlation with EIPG (r2 = 0.79 p < 0.001), better than scoring provided by the automated analysis (r2 = 0.71, p < 0.006 for EIAUT vs. EIPG). CONCLUSIONS: In stable OHS patients on NIV, unattended home-based monitoring using Rescan is reproducible and reliable to assess quality of ventilation when compared with PG. In addition, manual scoring of events using data obtained with this device is more consistent than software-based automated analysis.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua/instrumentación , Ventilación no Invasiva/instrumentación , Síndrome de Hipoventilación por Obesidad/terapia , Programas Informáticos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pletismografía , Polisomnografía , Estudios Prospectivos , Ventilación Pulmonar , Reproducibilidad de los Resultados , Ventiladores Mecánicos
3.
Lung ; 194(3): 469-73, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27048175

RESUMEN

PURPOSE: In obstructive sleep apnea-hypopnea syndrome (OSAS), airway collapses and vibrations cause local and systemic inflammatory response and oxidative stress (OS). Our objective was to determine the presence of OS in the airway of patients with OSAS compared with controls without OSAS and determine its relation to treatment with CPAP and other clinical variables. METHOD: We performed a prospective observational case-control study with repeated measures. We recruited consecutive patients with SAHS diagnosed using complete polysomnography, and a parallel control group. We collected a sample of exhaled breath condensate (EBC) prior to nasal continuous positive airway pressure (CPAP) treatment and again after 4 months. The marker of OS used was 8-isoprostane (8-IPN). The variables analyzed were age, sex, anthropometric variables, apnea-hypopnea index (AHI), snoring, oxygenation, and polysomnographic variables. RESULTS: The study included 20 patients and 10 controls. In cases, the initial value of 8-IPN was 6.8 (1.9), and after nasal CPAP, it was 5.3 (1.2) pg/ml (p = 0.02). In controls, the value of 8-IPN was 5.6 (1.1) pg/ml (p = 0.04 compared to initial values). 8-IPN showed significant correlation with snoring, AHI, BMI, nocturnal desaturation index, and non-REM sleep. On multivariate analysis, only snoring was a significant predictor of 8-IPN. CONCLUSIONS: Snoring, and not OSAS severity, could be the phenomenon underlying the presence of local OS measured in the airway of patients with OSAS.


Asunto(s)
Dinoprost/análogos & derivados , Estrés Oxidativo , Apnea Obstructiva del Sueño/metabolismo , Ronquido/metabolismo , Adulto , Anciano , Índice de Masa Corporal , Pruebas Respiratorias , Estudios de Casos y Controles , Presión de las Vías Aéreas Positiva Contínua , Dinoprost/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/terapia , Ronquido/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...