1.
Rev Sci Instrum ; 92(5): 053543, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243308

RESUMEN

Neutron-yield diagnostics at the NIF have been upgraded to include 48 detectors placed around the NIF target chamber to assess the DT-neutron-yield isotropy for inertial confinement fusion experiments. Real-time neutron-activation detectors are used to understand yield asymmetries due to Doppler shifts in the neutron energy attributed to hotspot motion, variations in the fuel and ablator areal densities, and other physics effects. In order to isolate target physics effects, we must understand the contribution due to neutron scattering associated with the different hardware configurations used for each experiment. We present results from several calibration experiments that demonstrate the ability to achieve our goal of 1% or better precision in determining the yield isotropy.

2.
Rev Sci Instrum ; 90(1): 013702, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30709218

RESUMEN

The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically bent crystal imager developed for the National Ignition Facility (NIF), which will allow inertial confinement fusion capsule implosions to be radiographed close to stagnation. This is not possible using the standard pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter signal in the final stages of the implosion. The CBI mitigates the broadband self-emission from the capsule hot spot by using the extremely narrow bandwidth inherent to near-normal-incidence Bragg diffraction. Implementing a backlighter system based on near-normal reflection in the NIF chamber presents unique challenges, requiring the CBI to adopt novel engineering and operational strategies. The CBI currently operates with an 11.6 keV backlighter, making it the highest energy radiography diagnostic based on spherically bent crystals to date. For a given velocity, Doppler shift is proportional to the emitted photon energy. At 11.6 keV, the ablation velocity of the backlighter plasma results in a Doppler shift that is significant compared to the bandwidth of the instrument and the width of the atomic line, requiring that the shift be measured to high accuracy and the optics aligned accordingly to compensate. Experiments will be presented that used the CBI itself to measure the backlighter Doppler shift to an accuracy of better than 1 eV. These experiments also measured the spatial resolution of CBI radiographs at 7.0 µm, close to theoretical predictions. Finally, results will be presented from an experiment in which the CBI radiographed a capsule implosion driven by a 1 MJ NIF laser pulse, demonstrating a significant (>100) improvement in the backlighter to self-emission ratio compared to the pinhole-based area-backlighter configuration.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...