Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Alzheimers Res Ther ; 16(1): 42, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38378643

RESUMEN

INTRODUCTION: Optical coherence tomography angiography (OCT-A) is a novel tool that allows the detection of retinal vascular changes. We investigated the association of macular vessel density (VD) in the superficial plexus assessed by OCT-A with measures of cerebrovascular pathology and atrophy quantified by brain magnetic resonance imaging (MRI) in non-demented individuals. METHODS: Clinical, demographical, OCT-A, and brain MRI data from non-demented research participants were included. We analyzed the association of regional macular VD with brain vascular burden using the Fazekas scale assessed in a logistic regression analysis, and the volume of white matter hyperintensities (WMH) assessed in a multiple linear regression analysis. We also explored the associations of macular VD with hippocampal volume, ventricle volume and Alzheimer disease cortical signature (ADCS) thickness assessed in multiple linear regression analyses. All analyses were adjusted for age, sex, syndromic diagnosis and cardiovascular variables. RESULTS: The study cohort comprised 188 participants: 89 with subjective cognitive decline and 99 with mild cognitive impairment. No significant association of regional macular VD with the Fazekas categories (all, p > 0.111) and WMH volume (all, p > 0.051) were detected. VD in the nasal quadrant was associated to hippocampal volume (p = 0.007), but no other associations of macular VD with brain atrophy measures were detected (all, p > 0.05). DISCUSSION: Retinal vascular measures were not a proxy of cerebrovascular damage in non-demented individuals, while VD in the nasal quadrant was associated with hippocampal atrophy independently of the amyloid status.


Asunto(s)
Vasos Retinianos , Tomografía de Coherencia Óptica , Humanos , Angiografía con Fluoresceína/métodos , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/patología , Atrofia/patología , Tomografía de Coherencia Óptica/métodos
2.
Alzheimers Res Ther ; 16(1): 38, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38365752

RESUMEN

BACKGROUND: Several studies have reported a relationship between retinal thickness and dementia. Therefore, optical coherence tomography (OCT) has been proposed as an early diagnosis method for Alzheimer's disease (AD). In this study, we performed a genome-wide association study (GWAS) aimed at identifying genes associated with retinal nerve fiber layer (RNFL) and ganglion cell inner plexiform layer (GCIPL) thickness assessed by OCT and exploring the relationships between the spectrum of cognitive decline (including AD and non-AD cases) and retinal thickness. METHODS: RNFL and GCIPL thickness at the macula were determined using two different OCT devices (Triton and Maestro). These determinations were tested for association with common single nucleotide polymorphism (SNPs) using adjusted linear regression models and combined using meta-analysis methods. Polygenic risk scores (PRSs) for retinal thickness and AD were generated. RESULTS: Several genetic loci affecting retinal thickness were identified across the genome in accordance with previous reports. The genetic overlap between retinal thickness and dementia, however, was weak and limited to the GCIPL layer; only those observable with all-type dementia cases were considered. CONCLUSIONS: Our study does not support the existence of a genetic link between dementia and retinal thickness.


Asunto(s)
Enfermedad de Alzheimer , Estudio de Asociación del Genoma Completo , Humanos , Puntuación de Riesgo Genético , Fibras Nerviosas , Tomografía de Coherencia Óptica/métodos , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/genética , Enfermedad de Alzheimer/complicaciones , Cognición
3.
Front Neurosci ; 17: 1076177, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36908784

RESUMEN

Background: Optical coherence tomography angiography (OCT-A) is a novel method in the dementia field that allows the detection of retinal vascular changes. The comparison of OCT-A measures with established Alzheimer's disease (AD)-related biomarkers is essential to validate the former as a marker of cerebrovascular impairment in the AD continuum. We aimed to investigate the association of macular vessel density (VD) in the superficial plexus quantified by OCT-A with the AT(N) classification based on cerebrospinal fluid (CSF) Aß1-42, p181-tau and t-tau measurements in individuals with mild cognitive impairment (MCI). Materials and methods: Clinical, demographic, ophthalmological, OCT-A and CSF core biomarkers for AD data from the Neuro-ophthalmology Research at Fundació ACE (NORFACE) project were analyzed. Differences in macular VD in four quadrants (superior, nasal, inferior, and temporal) among three AT(N) groups [Normal, Alzheimer and Suspected non-Alzheimer pathology (SNAP)] were assessed in a multivariate regression model, adjusted for age, APOE ε4 status, hypertension, diabetes mellitus, dyslipidemia, heart disease, chronic obstructive pulmonary disease and smoking habit, using the Normal AT(N) group as the reference category. Results: The study cohort comprised 144 MCI participants: 66 Normal AT(N), 45 Alzheimer AT(N) and 33 SNAP AT(N). Regression analysis showed no significant association of the AT(N) groups with any of the regional macular VD measures (all, p > 0.16). The interaction between sex and AT(N) groups had no effect on differentiating VD. Lastly, CSF Aß1-42, p181-tau and t-tau measures were not correlated to VD (all r < 0.13; p > 0.13). Discussion: Our study showed that macular VD measures were not associated with the AT(N) classification based on CSF biomarkers in patients with MCI, and did not differ between AD and other underlying causes of cognitive decline in our cohort.

4.
Sci Rep ; 12(1): 16938, 2022 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-36209290

RESUMEN

Optical coherence tomography angiography (OCT-A) allows the detection of retinal vessel density (VD) loss, which is a reflection of brain vascular pathology. We aimed to investigate differences in macular VD in the superficial plexus in a large cohort of individuals cognitively unimpaired (CU), with mild cognitive impairment due to Alzheimer´s disease (MCI-AD), MCI due to cerebrovascular pathology (MCI-Va), probable Alzheimer´s disease dementia (ADD) and Vascular Dementia (VaD). Clinical, demographical, ophthalmological and OCT-A data from the Neuro-ophthalmology Research at Fundació ACE (NORFACE) project were analyzed. Differences of macular VD in four quadrants (superior, nasal, inferior and temporal) among the five diagnostic groups were assessed in a multivariate regression model, adjusted by age, sex, education, hypertension, diabetes mellitus, heart disease and stroke. The study cohort comprised 672 participants: 128 CU, 120 MCI-AD, 111 MCI-Va, 257 ADD and 56 VaD. Regression analysis showed a significantly higher VD in the temporal quadrant in MCI-AD compared to CU participants (49.05 ± 4.91 vs 47.27 ± 4.17, p = 0.02, d = 0.40), and a significantly lower VD in the inferior quadrant in MCI-Va compared to CU participants (48.70 ± 6.57 vs 51.27 ± 6.39, p = 0.02, d = 0.40). Individuals with heart disease presented significantly lower VD in the inferior quadrant than those without (p = 0.01). The interaction of sex and diagnosis had no effect in differentiating VD. Mini-Mental State Examination (MMSE) scores were not correlated to VD (all r < 0.16; p > 0.07). In conclusion, our study showed that the MCI-AD and MCI-Va groups had significant differences in macular VD in opposite directions in the temporal and inferior quadrants, respectively, compared to CU participants, suggesting that macular VD might be able to differentiate two pathogenic pathways (AD- and cerebrovascular-related) in early stages of cognitive decline.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Cardiopatías , Enfermedad de Alzheimer/patología , Disfunción Cognitiva/diagnóstico , Angiografía con Fluoresceína/métodos , Cardiopatías/patología , Humanos , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/patología , Tomografía de Coherencia Óptica/métodos
5.
Alzheimers Res Ther ; 12(1): 37, 2020 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-32234080

RESUMEN

BACKGROUND: Optical coherence tomography (OCT) of the retina is a fast and easily accessible tool for the quantification of retinal structural measurements. Multiple studies show that patients with Alzheimer's disease (AD) exhibit thinning in several retinal layers compared to age-matched controls. Subjective cognitive decline (SCD) has been proposed as a risk factor for progression to AD. There is little data about retinal changes in preclinical AD and their correlation with amyloid-ß (Aß) uptake. AIMS: We investigated the association of retinal thickness quantified by OCT with Aß accumulation and conversion to mild cognitive impairment (MCI) over 24 months in individuals with SCD. METHODS: One hundred twenty-nine individuals with SCD enrolled in Fundació ACE Healthy Brain Initiative underwent comprehensive neuropsychological testing, OCT scan of the retina and florbetaben (FBB) positron emission tomography (PET) at baseline (v0) and after 24 months (v2). We assessed the association of sixteen retinal thickness measurements at baseline with FBB-PET status (+/-) and global standardize uptake value ratio (SUVR) as a continuous measure at v0 and v2 and their predictive value on clinical status change (conversion to mild cognitive impairment (MCI)) at v2. RESULTS: Mean age of the sample was 64.72 ± 7.27 years; 62.8% were females. Fifteen participants were classified as FBB-PET+ at baseline and 22 at v2. Every 1 µm of increased thickness in the inner nasal macular region conferred 8% and 6% higher probability of presenting a FBB-PET+ status at v0 (OR = 1.08, 95% CI = 1.02-1.14, p = 0.007) and v2 (OR = 1.06, 95% CI = 1.02-1.11, p = 0.004), respectively. Inner nasal macular thickness also positively correlated with global SUVR (at v0: ß = 0.23, p = 0.004; at v2: ß = 0.26, p = 0.001). No retinal measurements were associated to conversion to MCI over 24 months. CONCLUSIONS: Subtle retinal thickness changes in the macular region are already present in SCD and correlate with Aß uptake.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Disfunción Cognitiva , Retina , Anciano , Enfermedad de Alzheimer/diagnóstico , Péptidos beta-Amiloides/metabolismo , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Disfunción Cognitiva/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Retina/diagnóstico por imagen , Retina/patología
6.
Sci Rep ; 10(1): 1580, 2020 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-32005868

RESUMEN

Building on previous studies that report thinning of the macula in Alzheimer's disease (AD) and mild cognitive impairment (MCI) patients, the use of optical coherence tomography (OCT) has been proposed as a potential biomarker for AD. However, other studies contradict these results. A total of 930 participants (414 cognitively healthy people, 192 with probable amnestic MCI, and 324 probable AD patients) from a memory clinic were consecutively included in this study and underwent a spectral domain OCT scan (Maestro, Topcon) to assess total macular volume and thickness. Macular width measurements were also taken in several subregions (central, inner, and outer rings) and in layers such as the retinal nerve fiber (RNFL) and ganglion cell (CGL). The study employed a design of high ecological validity, with adjustment by age, education, sex, and OCT image quality. AD, MCI, and control groups did not significantly vary with regard to volume and retinal thickness in different layers. When these groups were compared, multivariate-adjusted analysis disclosed no significant differences in total (p = 0.564), CGL (p = 0.267), RNFL (p = 0.574), and macular thickness and volume (p = 0.380). The only macular regions showing significant differences were the superior (p = 0.040) and nasal (p = 0.040) sectors of the inner macular ring. However, adjustment for multiple comparisons nullified this significance. These results are not supporting existing claims for the usefulness of macular thickness as a biomarker of cognitive impairment in a memory unit. OCT biomarkers for AD should be subject to further longitudinal testing.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico , Mácula Lútea/diagnóstico por imagen , Tomografía de Coherencia Óptica , Anciano , Enfermedad de Alzheimer/patología , Biomarcadores , Estudios de Casos y Controles , Disfunción Cognitiva/diagnóstico , Disfunción Cognitiva/patología , Femenino , Humanos , Mácula Lútea/patología , Masculino
8.
Sci Rep ; 9(1): 8698, 2019 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-31213626

RESUMEN

Visual impairment is common in people living with dementia and regular ophthalmological exams may improve their quality of life. We evaluated visual function in a cohort of elderly individuals and analyzed its association with their degree of cognitive impairment. Participants underwent neurological and neuropsychological exams, neuro-ophthalmological assessment (visual acuity, intraocular pressure, rates of past ophthalmological pathologies, use of ocular correction, treatments and surgeries) and optical coherence tomography (OCT) scan. We analyzed differences in ophthalmological characteristics among diagnostic groups. The final sample of 1746 study participants aged ≥ 50 comprised 229 individuals with Subjective Cognitive Decline (SCD), 695 with mild cognitive impairment (MCI) and 833 with Dementia (Alzheimer disease: n = 660; vascular dementia: n = 92, Lewy body dementia: n = 34; frontotemporal dementia: n = 19 and other: n = 28). Age, gender and education were used as covariates. Patients with Dementia, compared to those with SCD and MCI, presented worse visual acuity (p < 0.001), used less visual correction (p = 0.02 and p < 0.001, respectively) and fewer ophthalmological treatments (p = 0.004 and p < 0.001, respectively) and underwent fewer ocular surgeries (p = 0.009 and p < 0.001, respectively). OCT image quality worsened in parallel to cognitive decline (Dementia vs SCD: p = 0.008; Dementia vs MCI: p < 0.001). No group differences in past ophthalmological disorders or abnormal OCT findings were detected. Efforts should be made to ensure dementia patients undergo regular ophthalmological assessments to correct their visual function in order to improve their quality of life.


Asunto(s)
Envejecimiento , Disfunción Cognitiva/fisiopatología , Memoria/fisiología , Trastornos de la Visión/fisiopatología , Anciano , Anciano de 80 o más Años , Disfunción Cognitiva/diagnóstico , Estudios de Cohortes , Demencia/diagnóstico , Demencia/fisiopatología , Femenino , Humanos , Presión Intraocular/fisiología , Modelos Logísticos , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas/estadística & datos numéricos , Servicio Ambulatorio en Hospital , Calidad de Vida , Tomografía de Coherencia Óptica/métodos , Trastornos de la Visión/diagnóstico , Agudeza Visual/fisiología
9.
Sci Rep ; 8(1): 16345, 2018 11 05.
Artículo en Inglés | MEDLINE | ID: mdl-30397251

RESUMEN

The use of optical coherence tomography (OCT) has been suggested as a potential biomarker for Alzheimer's Disease based on previously reported thinning of the retinal nerve fiber layer (RNFL) in Alzheimer's disease's (AD) and Mild Cognitive Impairment (MCI). However, other studies have not shown such results. 930 individuals (414 cognitively healthy individuals, 192 probable amnestic MCI and 324 probable AD) attending a memory clinic were consecutively included and underwent spectral domain OCT (Maestro, Topcon) examinations to assess differences in peripapillary RNFL thickness, using a design of high ecological validity. Adjustment by age, education, sex and OCT image quality was performed. We found a non-significant decrease in mean RNFL thickness as follows: control group: 100,20 ± 14,60 µm, MCI group: 98,54 ± 14,43 µm and AD group: 96,61 ± 15,27 µm. The multivariate adjusted analysis revealed no significant differences in mean overall (p = 0.352), temporal (p = 0,119), nasal (p = 0,151), superior (p = 0,435) or inferior (p = 0,825) quadrants between AD, MCI and control groups. These results do not support the usefulness of peripapillary RNFL analysis as a marker of cognitive impairment or in discriminating between cognitive groups. The analysis of other OCT measurements in other retinal areas and layers as biomarkers for AD should be tested further.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Fibras Nerviosas/metabolismo , Tomografía de Coherencia Óptica , Anciano , Enfermedad de Alzheimer/metabolismo , Biomarcadores/metabolismo , Estudios de Cohortes , Femenino , Humanos , Masculino
10.
J Ophthalmol ; 2018: 8285637, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30046464

RESUMEN

PURPOSE: To present the outcomes of hybrid multifocal and monofocal intraocular lenses (IOLs) and to compare with refractive and diffractive multifocal IOLs (MFIOLs). METHODS: Three hundred twenty eyes (160 patients) underwent cataract surgery with randomized IOLs bilateral implantation. Changes in uncorrected and distance-corrected logMAR distance, intermediate and near (UNVA and DCNVA) visual acuity (VA), contrast sensitivity (CS), presence of dysphotopsia, spectacle independence, and patient satisfaction were analyzed. RESULTS: Postoperative VA in the hybrid (OptiVis) group was improved in all distances (p < 0.001). OptiVis acted superiorly to monofocal IOLs in UNVA and DCNVA (p < 0.001 for both) and to refractive ones in DCNVA (p < 0.005). Distance, mesopic, without glare CS in OptiVis was lower than in the monofocal group and similar to other MFIOLs. No differences in dysphotopsia pre- and postoperatively and spectacle independence in near for OptiVis and refractive MFIOLs were detected. OptiVis patients were more satisfied than those with monofocal IOLs (p=0.015). CONCLUSIONS: After cataract surgery, patients with OptiVis improved VA in all distances. Near and intermediate VA was better than monofocal, and DCNVA was better than the refractive group. CS was lower in OptiVis than in the monofocal group, but there was no difference between MFIOLs. Patient satisfaction was higher in OptiVis than in the monofocal group. This trial is registered with NCT03512626.

12.
Retina ; 35(6): 1240-6, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25650709

RESUMEN

PURPOSE: To evaluate the effect of vitreous floaters on intraocular straylight. METHODS: Records of bilaterally phakic patients with unilateral complaint of floaters as the main symptom were identified from an electronic database. Patients who underwent straylight measurements on both affected and unaffected eyes using a C-Quant straylight meter were selected. Data were collected on age, sex, visual acuity, straylight measurements, and optical coherence tomography. The unaffected eye served as a control. RESULTS: Fifteen cases were included (7 women and 8 men; mean age, 54.3 years; age range, 24-71 years). Visual acuity was not correlated with the complaint of floaters. Average straylight value in eyes with floaters was 1.426 log(s) (±0.23 SD) with a median value of 1.52 log(s). The mean value for fellow eyes was 1.275 (±0.23 SD) with a median of 1.25 log(s). The differences between both groups using a Wilcoxon matched-pair signed-rank test was statistically significant at P = 0.0009. On optical coherence tomography, most patients had a confirmed or probable posterior vitreous detachment. However, in four patients, a posterior vitreous detachment was absent in the affected eyes. Vitreous floaters were inconsistently imaged by optical coherence tomography, with only a few patients presenting appreciable condensations close to the retinal surface. These were present in both affected and unaffected eyes. CONCLUSION: Intraocular straylight is significantly increased in eyes affected by floaters. No correlation was seen with vision or optical coherence tomography appearance. Straylight is an independent objective measure of visual perception that seems to be closely correlated to complaints expressed by patients experiencing floaters.


Asunto(s)
Oftalmopatías/fisiopatología , Deslumbramiento , Dispersión de Radiación , Cuerpo Vítreo/fisiopatología , Adulto , Anciano , Oftalmopatías/diagnóstico , Femenino , Humanos , Luz , Masculino , Persona de Mediana Edad , Tomografía de Coherencia Óptica , Agudeza Visual/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...