Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Intervalo de año de publicación
1.
Front Reprod Health ; 5: 1239175, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37965590

RESUMEN

The present study compares two protocols for ovarian controlled stimulation in terms of number of cumulus-oocyte complexes and metaphase II oocytes. We employed a single injection of 150mcg of corifollitropin alfa after a 7-day oral contraceptive pill-free interval for TAIL group and a conventional administration of corifollitropin alfa after a 5-day OCP-free interval with additional rFSH from 8th of ovarian controlled stimulation. Prospective, randomized, comparative, non-inferiority, opened and controlled trial carried out in 180 oocyte donors 31 were excluded, 81 were randomized to the control group and 68 to the TAIL group. No differences were found in the number of follicles larger than 14 and 17 mm at triggering day. However, a lower number of cumulus-oocyte complexes and metaphase II oocytes were obtained in TAIL group compared to the control group, expressed as median (interquartile range): 10.5 (5.5-19) vs. 14 [11-21] and 9 (4-13) vs. 12 (9-17) respectively. Additionally, the incidence of failed retrieval or metaphase II oocytes = 0 was higher in TAIL group 7(10.3%) vs. 1(1.2%) p = 0.024. The use of a single injection of corifollitropin alfa after a 7-day oral contraceptive pill-free interval in oocyte donors resulted in a lower number of cumulus-oocyte complexes and metaphase II oocytes. No additional rFSH was administered in this group. Clinical Trial Registration: https://www.clinicaltrialsregister.eu/ctr-search/trial/2019-001343-44/results.

2.
Front Endocrinol (Lausanne) ; 14: 1285040, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38027116

RESUMEN

Introduction: Embryo implantation is a complex and poorly understood process. Most studies to date have focused on the analysis of the endometrium at the end of the estrogenic phase, while the available data on its importance after secretory transformation are limited and inconsistent. Current evidence does not allow for a conclusive interpretation of the changes observed in the pre-implantation endometrium, whether in the natural or replacement cycle, and their relevance in the development of a pregnancy or the implications for clinical practice. Methods: Multicenter prospective observational cohort study. Based on our sample size calculation, the study group will consist of 206 women (exposed or "compaction" group: 103 women with a decrease of ≥ 5% in endometrial thickness between the estrogenic phase and the day of embryo transfer; non-exposed "non-compaction" group: 103 women with similar or greater endometrial thickness between these time points). The main objective of this study is to compare the ongoing pregnancy rates in natural cycles for euploid embryo transfer in patients who present endometrial compaction at the time of transfer versus those who with a stable or greater endometrial thickness with respect to the estrogenic phase. The estimated duration of the study is 30 months. Inclusion criteria are: 18 to 50 years of age, with primary or secondary infertility, subjected to endometrial preparation in a modified natural cycle for transfer of a genetically euploid blastocyst, from their own oocyte or oocyte donation, with a normal uterine cavity. Exclusion criteria are: uterine or endometrial disease (e.g., multiple myomatosis, severe adenomyosis, Asherman syndrome, refractory endometrium), conditions that prevent correct ultrasound assessment (tilted uterus), or a history of recurrent implantation failure or repeated miscarriages. Discussion: The findings from this study will provide valuable insights into the potential influence of the "endometrial compaction" phenomenon on reproductive outcomes during natural cycle endometrial preparation. By examining this aspect, we aim to contribute to a better understanding of the factors that may impact successful outcomes in fertility treatments.


Asunto(s)
Implantación del Embrión , Transferencia de Embrión , Embarazo , Humanos , Femenino , Estudios Prospectivos , Índice de Embarazo , Transferencia de Embrión/métodos , Endometrio , Estudios Observacionales como Asunto , Estudios Multicéntricos como Asunto
3.
Artículo en Español | LILACS-Express | LILACS, LIPECS | ID: biblio-1522479

RESUMEN

Los ultrasonidos de alta definición en tiempo real (HDLive US) incorporan un software que calcula la propagación de la luz a través de superficies y en relación con la dirección de la misma. Esta fuente de luz puede ser posicionada libremente con el fin de iluminar las áreas de interés deseadas, permitiendo así imágenes de mejor calidad, una mayor sensación de profundidad y una visión más sencilla de superficies fetales. Mostramos casos de embriones y fetos normales, así como algunas malformaciones para señalar las posibilidades de esta nueva tecnología. El auténtico potencial de esta nueva tecnología esta aún por revelar. La HDLive representa, en nuestra opinión, una verdadera innovación y un paso más hacia una visión anatómica mucho más realista de estructuras normales y patológicas fetales.


High definition real time ultrasound (HDLive US) incorporates software that calculates the propagation of light through surface structures in relation to light direction. This light source can be freely positioned in order to illuminate the desired area of interest allowing better image quality, better sensation of deepness and easier visualization of fetal surfaces. Cases of normal embryos, fetuses and common fetal malformations are shown. The full potential of this new technology is still to be revealed. HDlive represents, in our opinion, an innovative tool and a step towards an even more realistic anatomical visualization of normal and malformed fetuses.

4.
Prog. obstet. ginecol. (Ed. impr.) ; 50(4): 216-223, abr. 2007. ilus, tab
Artículo en Es | IBECS | ID: ibc-052984

RESUMEN

Objetivo: Ésta es una somera revisión de las posibilidades en ultrasonografía 3D y 4D disponibles actualmente, que creemos de interés para los obstetras y ginecólogos. Método: Se describen los fundamentos de las técnicas actuales y las técnicas complementarias, así como las aplicaciones en obstetricia, ginecología y reproducción humana. Conclusión: El actual desarrollo de los modos de adquisición y software permite el manejo de las imágenes para optimizar el análisis de los datos y, de este modo, mejorar la certeza diagnóstica en diferentes áreas de la ginecología y la obstetricia


Objective: To provide a brief review of the currently available possibilities of 3D-4D ultrasonography, which we believe are of interest to obstetricians and gynecologists. Methods: We describe the basic principles of current techniques, complementary techniques, and their applications in obstetrics, gynecology and human reproduction. Conclusion: The current development of acquisition modes and software allows image manipulation to optimize data analysis and improves diagnostic accuracy in obstetrics and gynecology


Asunto(s)
Femenino , Embarazo , Humanos , Ultrasonografía Prenatal/métodos , Enfermedades Fetales , Amniocentesis , Flujometría por Láser-Doppler , Anomalías Congénitas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...