Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
JACC Clin Electrophysiol ; 9(6): 836-847, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36752462

RESUMEN

BACKGROUND: Multicenter ventricular tachycardia (VT) ablation studies have shown poorer outcomes compared with single-center experiences. This difference could be related to heterogeneous mapping and ablation strategies. OBJECTIVES: This study evaluated a homogenous simplified catheter ablation strategy for different substrates and compared the results with those of a single referral center. METHODS: This was a multicenter prospective VT ablation registry of patients with the following 4 causes of VT: previous myocardial infarction; previous myocarditis; arrhythmogenic right ventricular dysplasia; or idiopathic dilated cardiomyopathy. The procedural protocol included precise mapping and ablation steps with the combined endpoint of late potential (LP) abolition and noninducibility of VT. The long-term primary efficacy endpoint was freedom from VT. RESULTS: A total of 309 patients were enrolled. LPs were present in 70% of patients and were abolished in 83%. At the end of the procedure 74% of LPs were noninducible. The primary combined endpoint of LP abolition and noninducibility was achieved in 64% of patients with LPs at baseline. Freedom from VT at 12 months was observed in 67% of patients. In the overall study group, VT inducibility was the only predictor of freedom from VT (P = 0.013). In patients with LPs, the VT recurrence rate was lower both for patients with complete LP abolition (P = 0.040) and for patients meeting the composite endpoint (P = 0.035). CONCLUSIONS: A standardized VT mapping and ablation technique reproduced the procedural outcomes of a single referral center in a multicenter prospective study. LP abolition and noninducibility were effective in reducing VT recurrences in patients with 4 causes of cardiomyopathy. (Ventricular Tachycardia Ablation Registry; NCT03649022).


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Estudios Prospectivos , Resultado del Tratamiento , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología , Lipopolisacáridos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Sistema de Registros
2.
Minerva Cardiol Angiol ; 71(1): 91-99, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35080355

RESUMEN

BACKGROUND: Catheter ablation (CA) of atrial fibrillation (AF) is used routinely to establish rhythm control. There is mounting evidence that CA procedures should be performed during continuous oral anticoagulation and direct oral anticoagulants (DOACs) are considered the first anticoagulation strategy. Few real-life data are now available and even less in the Italian panorama. METHODS: IRIS is an Italian multicenter, non-interventional, prospective study which will be enrolled consecutive AF patients eligible for CA and treated with Rivaroxaban; patients in treatment with Rivaroxaban proceeded directly to CA while Rivaroxaban-naive patients were scheduled for CA after 4 weeks of uninterrupted anticoagulation unless the exclusion of atrial thrombi. Rivaroxaban was uninterrupted or shortly uninterrupted (<24 hours) prior CA, in line with routinely practice of each operator. Patients will be followed on continuous anticoagulation for 1 month after the ablation. The primary efficacy outcome is the cumulative incidence of all-cause death and systemic embolism while the primary safety outcome is the incidence of major bleeding events. The secondary outcomes are represented by non-major bleeding events. All events must be occurred within the first 30 days after the procedure. RESULTS: Two hundred fifty patients are expected to be enrolled and the study is estimated to be completed by the end of 2022. Up to now 56 patients have been enrolled. CONCLUSIONS: This study is the first large Italian prospective study on the management of Rivaroxaban in patients undergoing CA of AF. It aims to depict a comprehensive view of anticoagulation strategy prior CA in several Italian electrophysiology labs.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Rivaroxabán/efectos adversos , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Estudios Prospectivos , Inhibidores del Factor Xa/efectos adversos , Resultado del Tratamiento , Hemorragia/inducido químicamente , Hemorragia/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Sistema de Registros
4.
Heart Rhythm ; 18(8): 1292-1300, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33838316

RESUMEN

BACKGROUND: Sporadic high impedance values without other anomalies detected by remote monitoring of hybrid cardiac implantable electronic device systems have been described recently. The clinical significance and related hazard of this phenomenon are not fully understood. OBJECTIVE: The purpose of this study was to describe the prevalence, management, and outcomes associated with hybrid implantable cardioverter-defibrillator (ICD) systems. METHODS: We collected data on patients with sporadic high lead impedance alert on remote monitoring who had undergone implantation with a hybrid ICD system between January 2015 and December 2019. Pacing thresholds, sensing and impedance values, and temporal pattern of impedance values were collected by remote monitoring, at implantation, and during an in-office visit. RESULTS: Among 92 patients receiving a hybrid ICD, 15 (16.3%) had high impedance alert on remote monitoring (14 Boston Scientific and 1 St. Jude Medical ICD canisters paired with Medtronic or Biotronik DF-1 leads). Four patients had a cardiac resynchronization therapy-defibrillator (CRT-D), 7 a dual-chamber ICD, and 4 a single-chamber ICD. Three patients presented with high atrial lead impedance, 7 high right ventricular lead impedance, 1 high left ventricular impedance, and 2 high shock impedance values. All patients underwent follow-up by remote monitoring. Sporadic high impedance values were not associated with an adverse outcome or need for revision in all but 1 patient, who had continuously increasing pacing thresholds due to lead microfracture. CONCLUSION: In the absence of clear signs of lead fracture or connection issues, sporadic high pacing and shock impedance in hybrid implantable defibrillator systems can be safely managed by close follow-up.


Asunto(s)
Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Monitoreo Fisiológico/métodos , Telemedicina/métodos , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Impedancia Eléctrica , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
5.
J Cardiovasc Electrophysiol ; 31(7): 1694-1701, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32369225

RESUMEN

BACKGROUND: Ablation index (AI) is a new lesion quality marker that has been demonstrated to allow a high single-procedure arrhythmia-free survival in single-center studies. This prospective, multi-center study was designed to evaluate the reproducibility of pulmonary vein (PV) isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV isolation and were divided in four study groups according to operator's preference in choosing the ablation catheter (a contact force (ST) or contact force surround flow (STSF) catheter) and the AI setting (330-450 or 380-500 at anterior wall or posterior wall, respectively). RESULTS: At 12 months a high rate of freedom from AF recurrences was observed in patients with both paroxysmal and persistent AF (91% vs 83.3%; P = .039). There was no difference in the rate of AF recurrence among the four study groups (4.5% in group ST330-450, 12.2% in group ST 380-500, 14.9% in group STSF330-450, 9.4% in group STSF380-500; P = .083). Recurrence was also similar between patients treated with a ST (8%) or STSF catheter (12.1%; P = .2), and within patients targeting an AI settings of 330 to 450 (10.9%) or 380 to 500 (10.3%; P = .64). In patients with paroxysmal AF, there was no difference (P = .12) in the 1-year freedom from AF recurrence among 14 operators that performed ≥10 ablation procedure. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion resulted in high rate of 1-year freedom from AF recurrence, irrespective of the ablation catheters, AI settings, and operator.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Sistema de Registros , Reproducibilidad de los Resultados , Resultado del Tratamiento
6.
Pacing Clin Electrophysiol ; 42(7): 874-881, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31045257

RESUMEN

BACKGROUND: Atrial fibrillation (AF) ablation outcome is still operator dependent. Ablation Index (AI) is a new lesion quality marker that has been demonstrated to allow acute durable pulmonary vein (PV) isolation followed by a high single-procedure arrhythmia-free survival. This prospective, multicenter study was designed to evaluate the reproducibility of acute PV isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV encircling and were divided in four study groups according to operator preference in choosing the ablation catheter (a contact force [ST] or contact force surround flow [STSF] catheter) and the AI setting (330 at posterior and 450 at anterior wall or 380 at posterior and 500 at anterior wall). Radiofrequency was delivered targeting interlesion distance ≤6 mm. RESULTS: The rate of first-pass PV isolation (ST330 90 ± 16%, ST380 87 ± 19%, STSF330 90 ± 17%, STSF380 91 ± 15%, P = .585) was similar among the four study groups, whereas procedure (ST330 129 ± 44 minutes, ST380 144 ± 44 minutes, STSF330 120 ± 72 minutes, STSF380 125 ± 73 minutes, P < .001) and fluoroscopy time (ST330 542 ± 285 seconds, ST380 540 ± 416 seconds, STSF330 257 ± 356 seconds, STSF380 379 ± 454 seconds, P < 0.001) significantly differed. The difference in the rate of first-pass isolation was not statistical different (P = .06) among the 12 operators that performed at least 15 procedures. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion results in high and comparable rate of acute PV isolation among operator performing ablation with different catheters, AI settings, procedure, and fluoroscopy times.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Reproducibilidad de los Resultados
7.
Circ J ; 82(4): 974-982, 2018 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-29415917

RESUMEN

BACKGROUND: Our aim was to evaluate the clinical outcome of paroxysmal atrial fibrillation (AF) ablation with contact force technology, using an automated lesion tagging system (VISITAGTM module) with strict criteria of catheter stability.Methods and Results:We enrolled 200 consecutive patients who underwent pulmonary vein isolation (PVI) in 11 centers and were followed up for 12 months. The stability setting was within 3 mm for ≥10 s and for ≥15 s in 47% and 53% of patients, respectively. A mean of 67.2±21.9 VISITAGs was acquired. Freedom from atrial tachyarrhythmias at follow-up was 77.5% (155/200), and the contiguity between lesions was associated with a higher chronic success rate (96% vs. 77.1%; log-rank P=0.036). Radiofrequency (RF), fluoroscopy times, and recurrence rates at the 12-month follow-up were significantly lower than in a comparison group of 80 patients without VISITAGTM module (42.7±14.5 vs. 50.9±23.6 min; P=0.032; 11.6±7.8 vs. 18.4±12.8 min; P=0.003 and 22.5% vs. 41.2%; P=0.02). Two major complications (1 cardiac tamponade and 1 minor stroke) were observed only in the control group. CONCLUSIONS: Paroxysmal AF ablation with contact force technology and strict criteria of stability using the VISITAG module was a safe procedure, associated with an improvement in efficiency and a reduction of atrial tachyarrhythmia recurrence at the 12-month follow-up compared with manual annotation. Contiguity between lesions seemed to enhance effectiveness outcomes.


Asunto(s)
Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Venas Pulmonares/fisiopatología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Taquicardia/patología , Taquicardia/prevención & control , Resultado del Tratamiento , Adulto Joven
8.
J Cardiovasc Echogr ; 25(1): 26-28, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-28465924

RESUMEN

A 55-year-old man complaining of worsening dyspnea on exertion was diagnosed with restrictive interventricular septal defect, left ventricular noncompaction (LVNC), mild aortic valve stenosis and aorto-right ventricular fistula. He underwent surgical aortic valve replacement with a mechanical bileaflet valve (St. Jude n. 23) and contextual direct suture of interventricular septal defect and closure of aorto-right ventricular fistula. At 2 years of follow-up, the patient was in good general condition. A complete echocardiographic examination showed normalization of left ventricular dimensions and ejection fraction. Furthermore, left ventricular trabeculations became less evident and no longer met the diagnostic criteria for noncompaction. In our case, the expected left ventricular reverse remodeling after cardiac surgery was associated with a significant reduction in LVNC features. In conclusion, physicians should be careful in avoiding overdiagnosis of LVNC, whose features may indeed reflect only the hypertrabeculated morphology of a normal or pathological heart.

9.
J Interv Card Electrophysiol ; 42(1): 21-6, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25378035

RESUMEN

PURPOSE: Catheter-tissue contact is critical for effective lesion creation in radiofrequency catheter ablation (RFCA). In a multicenter prospective study, we assessed the relationship between catheter contact force (CF) during RFCA for paroxysmal atrial fibrillation (AF) and clinical recurrences over a mid-term follow-up. METHODS: All patients underwent RFCA for paroxysmal AF by antral pulmonary vein (PV) isolation, aiming at entry and exit conduction block in all PVs. A new open-irrigated tip catheter with CF sensing (SmartTouch(TM), Biosense Webster Inc. CA) was used. All patients were followed for at least 12 months and the relationship between CF and clinical outcomes assessed. RESULTS: One year follow-up was available in 92/95 of the patients enrolled. Acute PV isolation was achieved in 100 % of the veins. Mean CF during RFCA was 12.2 ± 3.9 g. Mean force-time integral (FTI) was 733 ± 505 gs. Following the 3-month blanking period, 17 (18 %) patients experienced at least 1 atrial tachyarrhythmia relapse. There was no statistical difference in mean CF (13 ± 3.4 g vs 12 ± 4 g, p = 0.32) and mean FTI (713 ± 487 gs vs 822 ± 590 gs, p = 0.42) between patients with and without arrhythmia recurrences. Recurrences were recorded in 22 % of patients achieving a mean FTI value below the median of 544 gs and in 15 % of patients with a mean FTI value above the median (p = 0.64). CONCLUSIONS: RFCA with CF data during PV isolation for paroxysmal AF improves physician's knowledge on catheter-tissue contact. In the present dataset, however, higher CF values did not impact mid-term clinical RFCA outcome.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/prevención & control , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Seguimiento , Humanos , Italia , Estudios Longitudinales , Persona de Mediana Edad , Recurrencia , Estrés Mecánico , Resultado del Tratamiento
11.
Europace ; 16(3): 335-40, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24337158

RESUMEN

AIMS: Catheter-tissue contact is critical for effective lesion creation in radiofrequency catheter ablation (RFCA). In a multicentre prospective study, we assessed the effect of direct contact force (CF) measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). METHODS AND RESULTS: A new open-irrigated tip catheter with CF sensing (SmartTouch™, Biosense Webster Inc.) was used. All the patients underwent the first ablation procedure for paroxysmal AF with antral pulmonary vein (PV) isolation, aiming at entry and exit conduction block in all PVs. Ninety-five patients were enroled in nine centres and successfully underwent ablation. Overall procedure time, fluoroscopy time, and ablation time were 138.0 ± 67.0, 14.3 ± 11.2, and 33.8 ± 19.4 min, respectively. The mean CF value during ablation was 12.2 ± 3.9 g. Force time integral (FTI) analysis showed that patients achieving a value below the median of 543.0gs required longer procedural (158.0 ± 74.0 vs. 117.0 ± 52.0 min, P = 0.004) and fluoroscopy (17.5 ± 13.0 vs. 11.0 ± 7.7 min, P = 0.007) times as compared with those in whom FTI was above this value. Patients in whom the mean CF during ablation was >20 g required shorter procedural time (92.0 ± 23.0 vs. 160.0 ± 67.0 min, P = 0.01) as compared with patients in whom this value was <10 g. Four groin haematomas were the only complications observed. CONCLUSION: Contact force during RFCA for PV isolation affects procedural parameters, in particular procedural and fluoroscopy times, without increasing complications.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Fluoroscopía , Sistema de Conducción Cardíaco/cirugía , Tempo Operativo , Venas Pulmonares/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estrés Mecánico , Tacto , Transductores , Resultado del Tratamiento , Adulto Joven
12.
Eur Heart J ; 33(11): 1344-50, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22285581

RESUMEN

AIMS: Patients at risk of sudden cardiac death (SCD) after myocardial infarction (MI) can be offered therapy with implantable cardioverter defibrillators (ICDs). Whether plasma biomarkers can help risk stratify for SCD and ventricular arrhythmias (VT/VF) is unclear. METHODS AND RESULTS: The primary objective of the CAMI-GUIDE study is to assess the predictive role of C-reactive protein for SCD or VT/VF in ischaemic patients with the ejection fraction <30% and ICDs. Secondary endpoints included all-cause mortality, hospitalizations, and death from heart failure. Additional analyses incorporated cystatin-C and NT-ProBNP in multi-marker approach for the prediction of adverse outcomes. A total of 300 patients were enrolled. All-cause mortality at 2 years was 22.6%, mortality from heart failure was 8.3%. Primary endpoint occurred in 17.3%. At a competing risk multivariable analysis adjusted for baseline variables, no significant difference in primary endpoint was found between patients with C-reactive protein ≤3 vs. >3 mg/L [heart rate (HR) 0.91 (0.50-1.64) P = 0.76], while C-reactive protein >3 mg/L was strongly associated with mortality due to heart failure [HR: 3.17 (1.54-6.54) P = 0.002]. NT-proBNP above median was significantly associated with the primary endpoint [adjusted HR: 1.46 (1.020-2.129) P = 0.042]. A risk function, including the three biomarkers, NYHA class and resting HR, allowed stratification of patient mortality risk from 5 to 50%. CONCLUSION: C-reactive protein >3 mg/L is not associated with SCD or fast VT/VF, however, is a strong predictor of HF mortality. Biomarkers combined with clinical markers allow an excellent risk stratification of mortality at 2 years.


Asunto(s)
Proteína C-Reactiva/metabolismo , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Infarto del Miocardio/sangre , Taquicardia Ventricular/terapia , Anciano , Biomarcadores/metabolismo , Métodos Epidemiológicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Taquicardia Ventricular/sangre , Taquicardia Ventricular/mortalidad
14.
J Cardiovasc Med (Hagerstown) ; 8(4): 293-9, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17413310

RESUMEN

BACKGROUND: Patients at risk of sudden cardiac death (SCD) after myocardial infarction (MI) can currently be offered effective means of prevention, such as implantable cardioverter-defibrillators (ICD). However, predictors of SCD able to identify those patients who are at higher risk are still lacking. Whether C-reactive protein (CRP), a serum inflammatory marker with established prognostic accuracy after MI, can also be a predictor of SCD is unclear. METHODS: The CAMI GUIDE study is designed to evaluate the prognostic role of CRP in patients undergoing ICD implantation after MI according to MADIT II criteria (i.e. left ventricular ejection fraction

Asunto(s)
Proteína C-Reactiva/metabolismo , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Infarto del Miocardio/terapia , Biomarcadores/sangre , Estudios de Cohortes , Interpretación Estadística de Datos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Estudios de Seguimiento , Humanos , Italia/epidemiología , Infarto del Miocardio/sangre , Infarto del Miocardio/complicaciones , Infarto del Miocardio/mortalidad , Selección de Paciente , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Proyectos de Investigación , Medición de Riesgo , Factores de Riesgo , Tamaño de la Muestra , Taquicardia Ventricular/sangre , Taquicardia Ventricular/prevención & control , Resultado del Tratamiento , Fibrilación Ventricular/sangre , Fibrilación Ventricular/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...