1.
Med Oral Patol Oral Cir Bucal ; 24(3): e398-e403, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-31011142

RESUMEN

BACKGROUND: The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. MATERIAL AND METHODS: In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV): > 32 Ncm (CG) and < 32 Ncm (LTG) and two different groups of equal sample size, 161 implants each, were distinguished. Crestal bone reabsorption, and the implant failure rate were evaluated after 2-years of follow-up. RESULTS: The bone reabsorption in LTG (0.49 ± 0.11 mm ) was significantly greater than CG (0.22 ± 0.04 mm), p<0.001. However, the survival rate after 2-years of follow-up was quite high and similar for both groups: 96.89% for LTG and 97.52% for CG and no statistically significant differences have been found among the two groups for the implant failure rate (p=0.455).The Odds Ratio (OR) of implant failure was of 1.258 (95% CI 0.332, 4.772), but results were not statistical significant, p=0.740. CONCLUSIONS: The present study showed that although implants with ITV> 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant differences among the two groups for what concerning the failure rate during the 2 years of follow-up and OR. These results permit us to suppose that the cut-off of ITV >32 Ncm for immediate loading implants, could be reduced to inferior values. However further studies are necessary to indicate precise clinical guidelines.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Carga Inmediata del Implante Dental , Implantación Dental Endoósea , Fracaso de la Restauración Dental , Humanos , Estudios Retrospectivos , Torque
2.
Clin Neuropharmacol ; 19(5): 439-43, 1996 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-8889287

RESUMEN

Acute single-dose response of drug-induced parkinsonism (DIP) to L-Dopa and apomorphine challenge was evaluated in a double-blind crossover study in 12 schizophrenic patients. There were two noteworthy negative findings. First, neither L-Dopa nor apomorphine produced significant improvements in DIP and second, no changes (neither improvement nor worsening) were found in patients' psychiatric status. Findings suggest that, for a stimulation dose reaching almost 90% of the responsive dose for idiopathic Parkinson's disease, no significant changes may reasonably be expected in the parkinsonism of schizophrenic patients treated with neuroleptic drugs.


Asunto(s)
Antiparkinsonianos/uso terapéutico , Apomorfina/uso terapéutico , Levodopa/uso terapéutico , Actividad Motora/efectos de los fármacos , Enfermedad de Parkinson Secundaria/tratamiento farmacológico , Enfermedad de Parkinson Secundaria/etiología , Esquizofrenia/inducido químicamente , Esquizofrenia/tratamiento farmacológico , Adulto , Análisis de Varianza , Antipsicóticos/efectos adversos , Estudios Cruzados , Método Doble Ciego , Femenino , Humanos , Enfermedad de Parkinson Secundaria/fisiopatología , Escalas de Valoración Psiquiátrica , Esquizofrenia/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...