Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Can J Cardiol ; 34(9): 1165-1173, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30170672

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) can cause injury to the atrioventricular conduction system. We evaluated the effect of transcatheter heart valve (THV) type on the rate of new pacemaker implantation and length of hospital stay. METHODS: Patients across all hospitals performing transfemoral TAVR in the province of British Columbia between 2012 and 2016 participated in a mandated registry with linkages to provincial health databases. We evaluated 1141 patients undergoing successful transfemoral TAVR for native aortic valve stenosis with 5 commonly used valves. RESULTS: Valves implanted were balloon-expandable (BEV) (n = 728), self-expandable (SEV) (n = 341), and mechanically-expandable (MEV) (n = 72). Baseline clinical characteristics were similar between groups: mean age 82.5 years with multiple comorbidities. The mean Society of Thoracic Surgeons predicted risk of mortality was 6.0%. Indwelling temporary pacemakers after TAVR varied by THV type: (BEV) 4.0%, (SEV) 69.3%, and (MEV) 63.0% (P < 0.002). The need for a new permanent pacemaker varied by THV type: (BEV) 6.6%, (SEV) 24.0%, and (MEV) 32.8% at 30 days (P < 0.001). At 1 year, permanent pacemaker rates continued to rise, and remained divergent: (BEV) 8.9%, (SEV) 26.9%, and (MEV) 35.9% (P < 0.001). Median length of stay varied according to THV type: (BEV) 1, (SEV) 3, and (MEV) 4 days (P < 0.001 across groups). Crude mortality rates were not statistically different by THV type, either at 30 days (BEV 3.0%, SEV 2.9%, and MEV 0.0%; P = 0.33), or at 1 year (BEV 10.3%, SEV 15.0%, and MEV 8.3%; P = 0.11). CONCLUSIONS: The choice of a THV device was associated with significant differences in the need for post-TAVR temporary pacemakers, hospital length of stay, and both early and late pacemaker implantation rates. These differences may have an impact on patient morbidity and resource utilization.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Tiempo de Internación/estadística & datos numéricos , Marcapaso Artificial/estadística & datos numéricos , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/epidemiología , Colombia Británica/epidemiología , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/estadística & datos numéricos , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/clasificación , Humanos , Masculino , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia , Periodo Posoperatorio , Diseño de Prótesis , Sistema de Registros/estadística & datos numéricos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...