Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Healthc Qual Res ; 35(6): 355-363, 2020.
Artículo en Español | MEDLINE | ID: mdl-33121917

RESUMEN

BACKGROUND AND OBJECTIVE: Doctors provide patients the information in written form by informed consents (IC), being the readability essential in the quality of care. The primary endpoint was to analyze the readability of IC published by the Chapter of Endovascular Surgery (CCEV) of the Spanish Society of Angiology and Vascular Surgery (SEACV) in 2019, and its evolution to those published by the SEACV in 2007. MATERIALS AND METHODS: The ICs were organized by sectors and we obtained the following parameters: syllables, words, phrases, average words/phrases and syllables/words, Flesch, Flesch-Szigriszt, Fernández-Huerta and Gunning-Fog indexes, as well as the grade on the Inflesz scale. RESULTS: The Flesch index classified the CCEV consents as very difficult, and the Gunning-Fog index reflected a readability equivalent to university texts. The Flesch-Szigriszt, Fernández-Huerta indexes and Inflesz scale classified them as normal. The ICs with less readability were those referring to supra-aortic trunks (SAT) and miscellaneous in the Fernández-Huerta (P<.020 and P<.05, respectively) and Flesch-Szigriszt (P<.05) indexes. However, ICs regarding venous pathology showed a better readability in this indexes (P<.006). CCEV consents were significantly longer than SEACV consents (P=.021). In addition, there was a decrease over time in the mean value of the Fernandez-Huerta and Flesch-Szigriszt indexes (P=.002). CONCLUSIONS: Although CCEV consents had a normal readability, it has been observed a decrease in the readability indexes compared to those published in 2007 by the SEACV. In addition the length and content of the ICs should be reviewed, especially those relating to SAT and miscellaneous.


Asunto(s)
Comprensión , Consentimiento Informado , Humanos
2.
Angiol. (Barcelona) ; 70(2): 60-65, mar.-abr. 2018. tab, graf
Artículo en Español | IBECS | ID: ibc-172327

RESUMEN

Objetivo: Evaluar el efecto anatómico a largo plazo de la reparación endovascular de la aorta torácica (TEVAR) en disecciones tipo B complicadas en comparación con segmentos no tratados de la aorta. Material y métodos: Entre enero de 2008 y septiembre de 2015, 18 pacientes con disección de aorta complicada tipo B se trataron mediante TEVAR con al menos un año de seguimiento en imágenes. Se realizaron angio-TC a los 3, 6, 12 meses y anualmente (media 25,25 ± 22,9 meses) a partir de entonces y se compararon con las angio-TC preoperatorias. Se registraron las medidas de mayor diámetro de la aorta, de la luz verdadera y de la luz falsa (LF) a nivel del segmento stentado, así como en segmentos no tratados de la aorta torácica y de la aorta abdominal supracelíaca. El análisis estadístico se realizó con un análisis de la varianza de efecto mixto para medidas repetidas. Resultados: La edad media fue de 57,67 años y un 88,9% eran hombres. La indicación de TEVAR fue: 5,6% síndrome de malperfusión, 27,8% hipertensión refractaria, 11,1% diámetro > 40mm, 50% dolor persistente y 5,6% hematoma periaórtico. El mayor diámetro de la aorta permaneció estable durante el seguimiento (p = 0,230), el diámetro de la luz verdadera en el segmento tratado aumentó (p = 0,005), y el diámetro de la LF disminuyó (p = 0,020). La trombosis completa de la LF se consiguió mediante la liberación de coils en aquellos casos con permeabilidad de LF y aumento del mayor diámetro de la aorta durante el seguimiento. Conclusiones: El tratamiento mediante TEVAR de disecciones agudas de aorta promueve la remodelación a largo plazo de los segmentos tratados en detrimento del diámetro de la LF en comparación con segmentos no tratados de la aorta. El uso de coils asocia trombosis a largo plazo de la LF y la estabilización del diámetro aórtico (AU)


Objective: To evaluate the long-term anatomical effect of thoracic endovascular aortic repair (TEVAR) in acute type B aortic dissection in comparison with untreated segments of the aorta. Material and methods. A total of 18 patients with complicated type B aortic dissection were treated with TEVAR between January 2008 and September 2015, and had over one-year follow-up imaging. Computed tomography angiograms obtained at 3, 6, and 12 months and long-term (mean 25.25 ± 22.9 months) were compared with baseline scans. The largest diameters of the stented thoracic aorta, stented true lumen, and stented false lumen (FL) were recorded at each time point, as well as the values in the unstented distal thoracic aorta and the abdominal aorta (supracoeliac). Changes over time were evaluated by a mixed effect analysis of variance model of repeated measurements. Results: The mean age of the patients was 57.67 years, and 88.9% were male. Indications for TEVAR were: 5.6% malperfusion, 27.8% refractory hypertension, 11.1% diameter > 40 mm, 50% persistent pain, and 5.6% peri-aortic haematoma. The maximum diameter of the stented thoracic aorta was stable (P = .230), the diameter of the stented true lumen increased (P = .005), and the diameter of the stented FL decreased (P = .020). Complete FL obliteration was achieved more significantly by liberating coils in those cases with residual patency of the FL and an increase in aortic diameter during follow-up. Conclusions: TEVAR of acute aortic dissection promotes long-term remodelling across the stented segment, with a significant long-term decrease of false lumen diameter compared to untreated segments of the aorta. The use of coils is significantly associated with long-term obliteration of the FL and stabilisation of aortic diameter (AU)


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Disección/métodos , Aorta Torácica/cirugía , Procedimientos Endovasculares/métodos , Angiografía , Revascularización Miocárdica/métodos , Aorta Torácica/anatomía & histología , Trombosis/complicaciones , 28599 , Análisis de Varianza , Hipertensión/complicaciones , Comorbilidad , Insuficiencia Renal/complicaciones
3.
Angiología ; 68(2): 96-103, mar.-abr. 2016. ilus, tab
Artículo en Español | IBECS | ID: ibc-148294

RESUMEN

OBJETIVO: Nanopartículas calcificantes (NP) se han detectado recientemente en muestras arteriales humanas y parecen estar involucradas en el proceso de calcificación. Este estudio fue diseñado para probar la hipótesis de que las NP de origen humano podrían agravar la respuesta a la lesión arterial endotelial e inducir la calcificación vascular. MÉTODOS: La arteria carótida derecha de 24 conejos neozelandeses fue lesionada con un balón de angioplastia. Los animales fueron perfundidos por vía intravenosa con solución salina (100 ml) durante el experimento y se dividieron en 3 grupos: grupo A, control; grupo B, expuesto a NP (2 ml) obtenidas a partir de válvulas aórticas calcificadas y el grupo C, expuesto a NP (2 ml) y tratado después de la operación con atorvastatina (2,5 mg/kg/24 h). A los 30 días, los animales fueron sacrificados y se extirparon las 2 arterias carótidas, que fueron examinadas histológicamente. Análisis bioquímicos de sangre fueron realizados durante el estudio. RESULTADOS: El área de hiperplasia intimal fue significativamente mayor en la arteria carótida derecha lesionada en comparación con la arteria carótida izquierda no operada, en todos los grupos. No hubo variación significativa en la zona medial entre los animales. Morfométricamente, la relación de íntima/media (IMR) fue significativamente mayor en las carótidas dañadas en comparación con los controles. Un aumento significativo de IMR se encontró en el grupo B (1,81 ± 0,41) en comparación con el grupo A (0,38 ± 0,59; p = 0,004) o el grupo C (0,89 ± 0,79; p = 0,035). Las diferencias entre los grupos C y A no fueron significativas (p = 0,064). Se observaron calcificaciones en 6 animales, todos los cuales habían sido expuestos a NP (4 en el grupo B, 2 en el grupo C, p = 0,027). Los niveles plasmáticos de colesterol y triglicéridos se mantuvieron estables. CONCLUSIONES: Este estudio confirma la capacidad de las NP de origen humano de acelerar la hiperplasia y estimular la calcificación de zonas arteriales endoteliales previamente dañadas. Su administración sistémica resultó inofensiva en las arterias sanas. La atorvastatina demostró la capacidad de ralentizar este proceso


OBJECTIVE: Calcifying nanoparticles (NP) have been detected recently in calcified human arterial specimens, and are involved in the process of calcification. This study was designed to test the hypothesis that human-derived NP could worsen the response to arterial endothelial injury and induce vascular calcification. METHODS: The right carotid artery of 24 New Zealand rabbits was injured with an angioplasty balloon. Animals were perfused intravenously with saline (100 mL) during the experiment and divided into 3 groups: group A, control; group B, exposed to NP (2 mL) obtained from calcified aortic valves; and group C, exposed to NP (2 mL) and treated post-operatively with atorvastatin (2.5 mg/kg/24 h). At 30 days, both carotid arteries were removed and examined histologically. Blood measurements were monitored during the study. RESULTS: The intimal hyperplasia area was significantly larger in the injured right carotid artery compared with the left un-operated carotid artery in all groups. There was no significant variation in medial area between groups. Morphometrically, the intima/media ratio (IMR) was significantly higher in damaged carotids compared with controls. A significant increase in the IMR was found in group B (1.81 ± 0.41) compared with group A (0.38 ± 0.59; P=.004) or group C (0.89 ± 0.79; P=.035). Differences between groups C and A were not significant (P=.064). Calcifications were observed in 6 animals, all of which had been exposed to NP (4 in group B, and 2 in group C, P=.027). Plasma levels of cholesterol and triglycerides remained stable. CONCLUSIONS: his study confirms the ability of systemic inoculation of human-derived NP to accelerate hyperplasia and stimulate calcification in localised areas of arteries previously submitted to endothelial damage, while it was harmless in healthy arteries. Atorvastatin was demonstrated to slow down this process


Asunto(s)
Animales , Masculino , Femenino , Conejos , Nanopartículas Calcificantes/análisis , Nanopartículas Calcificantes , Hiperplasia/diagnóstico , Hiperplasia/etnología , Calcificación Vascular/inducido químicamente , Calcificación Vascular/complicaciones , Calcificación Vascular/veterinaria , Traumatismos de las Arterias Carótidas/tratamiento farmacológico , Traumatismos de las Arterias Carótidas/veterinaria , Aterosclerosis/tratamiento farmacológico , Aterosclerosis/veterinaria
4.
Eur J Vasc Endovasc Surg ; 47(6): 640-6, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24725966

RESUMEN

OBJECTIVE: Calcifying nanoparticles (NPs) have been detected recently in calcified human arterial specimens and are involved in the process of calcification. This study was designed to test the hypothesis that human-derived NPs could worsen the response to arterial endothelial injury and induce vascular calcification. METHODS: The right carotid artery of 24 New Zealand rabbits was injured with an angioplasty balloon. Animals were perfused intravenously with saline (100 mL) during the experiment and divided into three groups: group-A, control; group-B, exposed to NPs (2 mL) obtained from calcified aortic valves; and group-C, exposed to NPs (2 mL) and treated postoperatively with atorvastatin (2.5 mg/kg/24 h). At 30 days, both carotid arteries were removed and examined histologically. Blood measurements were monitored during the study. RESULTS: The intimal hyperplasia area was significantly larger in the injured right carotid artery compared with the left unoperated carotid artery in all groups. There was no significant variation in medial area between groups. Morphometrically, the intima/media ratio (IMR) was significantly higher in damaged carotids compared with controls. A significant increase of IMR was found in group-B (1.81 ± 0.41) compared with group-A (0.38 ± 0.59; p = .004) or group-C (0.89 ± 0.79; p = .035). Differences between groups C and A were not significant (p = .064). Calcifications were observed in six animals, all of which had been exposed to NPs (4 in group-B, 2 in group-C, p = .027). Plasma levels of cholesterol and triglycerides remained stable. CONCLUSIONS: This research confirms the ability of systemic inoculation of human-derived NPs to accelerate hyperplasia and stimulate calcification in localized areas of arteries previously submitted to endothelial damage, while it was harmless in healthy arteries. Atorvastatin was demonstrated to slow down this process.


Asunto(s)
Nanopartículas Calcificantes/metabolismo , Traumatismos de las Arterias Carótidas/metabolismo , Músculo Liso Vascular/metabolismo , Calcificación Vascular/metabolismo , Angioplastia de Balón , Animales , Atorvastatina , Nanopartículas Calcificantes/administración & dosificación , Arterias Carótidas/metabolismo , Arterias Carótidas/patología , Traumatismos de las Arterias Carótidas/sangre , Traumatismos de las Arterias Carótidas/etiología , Traumatismos de las Arterias Carótidas/patología , Grosor Intima-Media Carotídeo , Colesterol/sangre , Modelos Animales de Enfermedad , Ácidos Heptanoicos/farmacología , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/farmacología , Hiperplasia , Masculino , Músculo Liso Vascular/efectos de los fármacos , Músculo Liso Vascular/lesiones , Músculo Liso Vascular/patología , Neointima , Pirroles/farmacología , Conejos , Factores de Tiempo , Triglicéridos/sangre , Calcificación Vascular/sangre , Calcificación Vascular/etiología , Calcificación Vascular/patología
7.
Angiología ; 61(6): 295-304, nov.-dic. 2009. tab, graf
Artículo en Español | IBECS | ID: ibc-81352

RESUMEN

Introducción. La cirugía abierta de AAA (CA) se asocia con un empeoramiento de la función sexual. A la reparación endovascular (EVAR) se le ha supuesto una menor incidencia de disfunción eréctil. Objetivos. Analizar la incidencia de disfunción sexual postoperatoria en pacientes tratados de AAA mediante CA o EVAR. Material y métodos. Estudio prospectivo mediante empleo de test IIEF-5 (International Index Erectile Function) para medición de disfunción sexual pre y postoperatoria desde enero de 2008 hasta junio de 2009. De 182 pacientes tratados, se incluyeron 112, 47 (42,0%) CA y 65 (58,0%) EVAR. Resultados. Edad media de 70 años (64,3 CA vs 74,7 EVAR, p=0,032). La prevalencia de impotencia preoperatoria fue elevada en ambos grupos y significativamente mayor en los tratados endovascularmente (40,5% CA vs 66,2% EVAR, p=0,017). Apareció en 5 pacientes (22,7%) tras EVAR y en 10 (35,7%) tras CA (p>0,05). Dentro del grupo EVAR, ambas iliacas internas fueron ocluidas a 3 pacientes (13,6%) y a 10 (45,5%) una. La oclusión unilateral de arteria hipogástrica no influyó en la aparición de impotencia (p>0,05), todas las oclusiones bilaterales sufrieron disfunción eréctil. La disfunción del grupo EVAR fue más severa, tanto durante el pre como en el postoperatorio. Conclusiones. La incidencia de disfunción sexual preoperatoria de los pacientes intervenidos de AAA es elevada. El tratamiento mediante EVAR no supone una protección significativa frente a la aparición de impotencia. La oclusión bilateral de arterias hipogástricas es causa de disfunción sexual, sin que la oclusión unilateral constituya un factor de riesgo significativo(AU)


Introduction. Open surgery (OS) of an abdominal aortic aneurysm (AAA) is associated with deterioration in sexual function. There appears to be lower incidence of erectile dysfunction with endovascular repair (EVAR). Objectives. To analyse the incidence of post-operative sexual dysfunction in AAA patients treated using OS or EVAR. Material and methods. A prospective study carried out from January 2008 until June 2009 using the IIEF test (International Index Erectile Function) to measure pre- and post-surgical sexual dysfunction. Out of a total of 182 patients treated, 112 patients were included in the study, of which 47 (42.0%) were treated using OS and 65 (58.0%) using EVAR.Results. The mean age was 70 years (64.3 OS vs. 74.7 EVAR, P=0.032). The prevalence of pre-surgical impotence was high in both groups and was significantly higher in those treated using EVAR (40.5% OS vs. 66.2% EVAR, P=0.017). Sexual dysfunction appeared in 5 patients (22.7%) after EVAR and in 10 (35.7%) after OS (P>0.05). Both internal iliacs were occluded in 3 (13.6%) patients in the EVAR group and occluded in one artery in 10 (45%) patients. The unilateral occlusion of the hypogastric artery had no effect on impotency (P>0.05). All the bilateral occlusions suffered erectile dysfunction. The dysfunction was more severe in the EVAR group, both before and after surgery. Conclusions. The incidence of pre-operative sexual dysfunction in AAA patients is high. Treatment using EVAR does not give any significant protection against impotency occurring. The bilateral occlusion of the hypogastric arteries is a cause of sexual dysfunction, although unilateral occlusion is a significant risk factor(AU)


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Angioplastia de Balón , Aneurisma de la Aorta Abdominal/cirugía , Disfunciones Sexuales Fisiológicas/epidemiología , Aneurisma de la Aorta Abdominal/complicaciones , Disfunción Eréctil/epidemiología
8.
Angiología ; 60(5): 359-363, sept.-oct. 2008. ilus
Artículo en Es | IBECS | ID: ibc-68516

RESUMEN

Introducción. Las técnicas endovasculares son útiles para el tratamiento de la enfermedad oclusiva ateroscleróticaen el sector aortoilíaco; la angioplastia transluminal percutánea con balón, con o sin la colocación de stent, estáampliamente aceptada. Una proporción importante de oclusiones de la arteria ilíaca puede recanalizarse con una combinaciónde angioplastia y stent, y muchas son las referencias bibliográficas al respecto, pero poco se ha comentado sobrerecanalizaciones tardías en oclusiones crónicas de injertos en este sector. Caso clínico. Mujer de 53 años de edad coninjerto iliofemoral izquierdo realizado hace cuatro años, ingresa por lesión trófica digital y dolor de reposo en pie izquierdo,refiere claudicación corta desde hace 3 meses, y presenta ausencia de pulsos en el miembro inferior izquierdo.En la arteriografía preoperatoria: obliteración de la arteria ilíaca externa en su origen con repermeabilización en la arteriafemoral común. Se logra mediante abordaje percutáneo contralateral la recanalización del bypass iliofemoral colocandodos stents solapados (8 × 37 mm proximal balón expandible y 7 × 100 mm distal recubierto) con buen resultadoangiográfico, recuperación del pulso femoral izquierdo y buena perfusión del pie. Conclusiones. La recanalización percutáneade una oclusión crónica de un injerto iliofemoral parece una excelente opción terapéutica en casos seleccionados,y más aún si se tiene en cuenta que las reintervenciones quirúrgicas son a menudo difíciles, y no exentas de complicaciones


Introduction. Endovascular techniques are useful for treating atherosclerotic occlusive disease in the aortoiliacsegment; percutaneous transluminal angioplasty with balloon, with or without the placement of a stent, is widelyaccepted. A high proportion of occlusions in the iliac artery can be recanalised with a combination of angioplasty andstent, and many cases have been reported in the literature; little has been said, however, about late recanalisations inchronic occlusions of grafts in this segment. Case report. A 53-year-old female with a left iliofemoral graft that had beenperformed four years earlier; the patient was admitted to hospital due to trophic lesions in the toes and rest pain in theleft foot, reported a three-month history of short claudication, and had no pulse in the lower left limb. In the preoperativearteriography: obliteration of the external iliac artery at its origin with restoration of patency in the common femoralartery. Using a contralateral percutaneous approach, the iliofemoral bypass was recanalised by placing two overlappingstents (8 × 37 mm proximal to the expandable balloon and 7 × 100 mm distal covered) with a good angiographicoutcome, recovery of the left femoral pulse and good perfusion of the foot. Conclusions. Percutaneous recanalisation ofa chronic occlusion of an iliofemoral graft seems to be an excellent therapeutic option in selected cases, and even moreso if we bear in mind that surgical reinterventions are often difficult to perform and are not free of complications


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Oclusión de Injerto Vascular/diagnóstico , Oclusión de Injerto Vascular/cirugía , Aneurisma Ilíaco/cirugía , Procedimientos Quirúrgicos Cardiovasculares/métodos , Angioplastia Coronaria con Balón/métodos , Angiografía/métodos , Trombosis/complicaciones , Trombosis/diagnóstico , Procedimientos Quirúrgicos Cardiovasculares/tendencias , Procedimientos Quirúrgicos Cardiovasculares , Angioplastia de Balón/métodos , Angioplastia de Balón/tendencias , Arteria Ilíaca/patología , Arteria Ilíaca/cirugía , Arteria Ilíaca
9.
Angiología ; 60(1): 17-25, ene.-feb. 2008. ilus, tab
Artículo en Es | IBECS | ID: ibc-64057

RESUMEN

Introducción. El tratamiento convencional de la patología compleja del arco aórtico requiere abordajes quirúrgicosagresivos, con una elevada morbimortalidad. La combinación de cirugía abierta y de procedimientos endovascularespuede reducir la agresión quirúrgica. Objetivo. Determinar los resultados a corto y medio plazo de la reparaciónhíbrida de las patologías complejas del arco aórtico mediante estudio prospectivo de observación. Pacientes y métodos.De 71 pacientes consecutivos sometidos a tratamiento endovascular de aorta torácica entre enero de 2000 y junio de2007, 10 requirieron técnicas híbridas. Las patologías aórticas intervenidas fueron: tres aneurismas arterioscleróticos(30%), tres disecciones tipo B (30%), tres pseudoaneurismas (30%) y una subclavia derecha aberrante (10%). Un pacienterequirió el anclaje de la endoprótesis en la zona 0 (10%), seis en la zona 1 (60%) y tres en la zona 2 (30%). Resultados.Tres pacientes fueron tratados de manera emergente (30%), consiguiendo un éxito clínico inicial del 90% y totaldel 100%. Un paciente falleció por neumonía asociada a ventilación mecánica. Sólo se observó un accidente cerebrovascular(10%), con una total recuperación clínica. Los pacientes con pseudoaneurismas y los que requirieron anclaje en lazona 1 mostraron una mayor estancia en la Unidad de Cuidados Intensivos y hospitalaria. El seguimiento medio de la seriefue de 13,5 meses (intervalo: 1-36 meses), con una supervivencia completa de la serie tras el postoperatorio inmediato,sin recidivas de las patologías intervenidas ni complicaciones relacionadas con el dispositivo endovascular. Conclusiones.El tratamiento híbrido de patologías complejas del arco aórtico presenta una pequeña incidencia de parálisismedulares y mortalidad, obteniendo unos resultados óptimos a corto y medio plazo


Introduction. The conventional treatment of complex aortic arch pathology requires invasive surgical approaches,with high morbidity and mortality rates. Combining open surgery and endovascular procedures can reduce the degree ofsurgical invasiveness. Aim. To determine short- and medium-term outcomes of hybrid repair of complex aortic archpathologies by means of a prospective observation-based study. Patients and methods. Of a sample of 71 consecutivepatients who underwent endovascular treatment of the thoracic aorta between January 2000 and June 2007, 10 requiredthe use of hybrid techniques. The aortic pathologies that were treated were: three arteriosclerotic aneurysms (30%),three type B dissections (30%), three pseudoaneurysms (30%) and one aberrant right subclavian (10%). In one patientthe stent had to be anchored in zone 0 (10%), six in zone 1 (60%) and three in zone 2 (30%). Results. Three patients weretreated emergently (30%), initial clinical success being 90% and the total success, 100%. One patient died of pneumoniaresulting from mechanical ventilation. Only one cerebrovascular accident (10%) was observed, with full clinicalrecovery. The patients with pseudoaneurysms and those who required anchoring in zone 1 spent a longer period of timein the Intensive Care Unit and also in the hospital ward. The mean follow-up time of the series was 13.5 months (range:1-36 months), with survival of the whole series after the immediate post-operative period; there were no recurrences ofthe pathologies that had been treated in the operations or complications related to the endovascular device. Conclusions.The hybrid treatment of complex aortic arch pathologies does present a small incidence of spinal paralysis and mortality,but short- and medium-term outcomes are optimum


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Procedimientos Quirúrgicos Vasculares/métodos , Enfermedades de la Aorta/cirugía , Aorta Torácica , Resultado del Tratamiento , Estudios de Seguimiento
10.
Angiología ; 59(6): 445-449, nov.-dic. 2007. ilus
Artículo en Es | IBECS | ID: ibc-62699

RESUMEN

Introducción. La fístula aortoentérica primaria es una excepcional, pero devastadora, etiología de sangrado digestivo.El ser portador de un aneurisma de aorta abdominal constituye el mayor factor de riesgo. La tríada clínica clásica es hemorragiadigestiva alta, dolor abdominal y masa abdominal pulsátil. La prueba diagnóstica con más utilidad es la tomografíacomputarizada con contraste intravenoso, a pesar de que la endoscopia se indica en los casos con sangrado digestivo. El tratamientoquirúrgico con injerto sintético in situ es la técnica de elección en casos sin elevado nivel de contaminación. La reparaciónendovascular es una alternativa factible en pacientes seleccionados. Caso clínico. Presentamos un caso de fístula aortoentéricaprimaria en el que se sospechó ruptura inminente de un aneurisma de aorta abdominal con su hallazgo intraoperatorio.Describimos las características etiológicas y clínicas, además de discutir el algoritmo diagnóstico actual y el papel de las nuevastécnicas endovasculares en su tratamiento


Introduction. Aortoenteric fistula is a rare but devastating cause of gastrointestinal bleeding. The traditionalclinical triad is upper gastrointestinal bleeding, abdominal pain and pulsatile abdominal mass. The computedtomographic scan with iodinated contrast is the most suitable diagnostic test although endoscopy is considered in allpatients with massive gastrointestinal bleeding. In-situ aortic reconstruction is the approach of choice in cases withoutextensive local level of contamination. The endovascular repair is a feasible alternative to traditional surgical treatmentin select patients. Case report. We present a case of primary aortoenteric fistula with intraoperative diagnosis in whichpreoperative suspect was ruptured of abdominal aortic aneurysm. We describe etiological and clinical features anddiscuss the update diagnostic tools and the role of new endovascular management


Asunto(s)
Humanos , Masculino , Anciano , Aneurisma de la Aorta/complicaciones , Aneurisma de la Aorta/diagnóstico , Factores de Riesgo , Endoscopía/métodos , Fístula Intestinal/cirugía , Angiografía/métodos , Diagnóstico Diferencial , Hemorragia Gastrointestinal/complicaciones , Hemorragia Gastrointestinal/diagnóstico , Fístula Intestinal/complicaciones , Fístula Intestinal/diagnóstico , Dolor Abdominal/diagnóstico , Dolor Abdominal/etiología , Aorta Abdominal/patología , Aorta Abdominal/cirugía , Duodeno/patología , Duodeno/cirugía , Duodeno
11.
Angiología ; 59(supl.2): s115-s119, jun. 2007. ilus
Artículo en Es | IBECS | ID: ibc-055982

RESUMEN

Objetivo. Se analiza la evolución natural del tratamiento endovascular de las lesiones esteno-oclusivas ateroscleróticas, intentando identificar los mecanismos etiopatogénicos responsables del fracaso técnic o de esta terapia. Desarrollo. Frente a la concepción clásica de que la recurrencia estenótica era debida principalmente a un fenómeno de hiperplasia intimal, actualmente se acepta que los dos mecanismos que contribuyen a la reestenosis son el remodelado arterial en el lugar de la lesión, que puede suponer hasta un 80% de la pérdida tardía de la luz, y la hiperplasia por medio de la proliferación celular. Aunque el empleo de stent puede reducir el efecto constrictivo del remodelado, su presencia dentro del vaso representa un estímulo proliferativo neointimal. La aplicación de braquiterapia y el desarrollo de stents temporales biodegradables con potencialidad de terapia génica o liberación de nuevos fármacos puede ser una alternativa futura para el control e inhibición de estas lesiones estenosantes. Conclusión. La reestenosis es una causa frecuente de fracaso de los procedimientos endovasculares


Aim. In this study we analyse the natural history of the endovascular treatment of atherosclerotic stenoocclusive lesions in an attempt to identify the etiopathogenic mechanisms responsible for the technical failure of this therapy. Development. In contrast to the classical conception that the recurrence of stenosis was mainly due to an intimal hyperplasia phenomenon, today it is accepted that the two mechanisms that contribute to restenosis are arterial remodelling at the site of the lesion, which can lead to up to 80% of the later loss of lumen, and hyperplasia by means of cell proliferation. Although the use of a stent can reduce the constrictive effect of the remodelling, its presence inside the vessel acts as a stimulant for neointimal proliferation. Application of brachytherapy and the development of biodegradable temporary stents with the possibility of gene therapy or the release of new drugs can be an alternative in the future for controlling and inhibiting these stenosing lesions. Conclusions. Restenosis is a frequent cause of failure in endovascular procedures


Asunto(s)
Humanos , Angioplastia/efectos adversos , Arteriopatías Oclusivas/cirugía , Oclusión de Injerto Vascular/etiología , Enfermedades Vasculares/cirugía , Arteriosclerosis/cirugía , Falla de Prótesis , Implantación de Prótesis Vascular/efectos adversos
13.
Angiología ; 57(5): 381-388, sept.-oct. 2005. tab
Artículo en Es | IBECS | ID: ibc-040987

RESUMEN

Introducción. Aunque la arteriografía se considera el patrón de referencia para la valoración de la arteriopatía periférica, la variabilidad en su interpretación es causa frecuente de disparidad diagnóstica y de tratamiento. Objetivo. Valorar la fiabilidad diagnóstica de la arteriografía preoperatoria y determinar la precisión y variabilidad interobservador, así como su implicación en la toma de decisiones terapéuticas. Pacientes y métodos. Se diseñó un estudio prospectivo en el que 100 angiografías de extremidades inferiores, seleccionadas aleatoriamente, se evaluaron de manera ciega e independiente por tres cirujanos vasculares. Las arterias se categorizaron como permeables, gravemente enfermas, ocluidas o no diagnóstica a diferentes niveles. La concordancia se expresó como valores κ y se analizó la opción terapéutica propuesta por cada observador basada en la historia clínica y hallazgos angiográficos. Resultados. El porcentaje de segmentos arteriales no identificados en la arteriografía preoperatoria (no diagnósticos) fue sorprendentemente elevado: 18% tibial anterior, 21% tibial posterior, 28% peronea. La concordancia global fue buena en segmento aórtico (κ = 0,78), ilíaco (κ = 0,76), femoral (κ = 0,61) y poplíteo supragenicular (κ = 0,64); moderado para poplítea infragenicular (κ = 0,50), y pobre para troncos tibiales (κ = 0,22). Aunque en el 70% de casos los tres observadores propusieron idéntico tratamiento (κ = 0,65, concordancia alta), en un 30% el plan terapéutico inicial basado en la angiografía preoperatoria no coincidía, y en un 19% de los casos este plan debió modificarse de acuerdo con los hallazgos intraoperatorios. Conclusiones. La importante variabilidad interobservador en la valoración de segmentos infrageniculares debe tenerse en cuenta cuando otros métodos diagnósticos se comparan con la angiografía preoperatoria. Este trabajo cuestiona su fiabilidad, enfatiza la necesidad de estudios angiográficos intraoperatorios y señala un importante sesgo en la interpretación de publicaciones cuando se intenta comparar esta prueba preoperatoria con respecto a otros métodos no invasivos


Introduction. Although arteriography is considered to be the reference standard for evaluation of peripheral arterial disease, the variations in its interpretation often lead to disparities in both diagnosis and in treatment. Aims. Our aim was to assess the diagnostic reliability of preoperative arteriography and to determine interobserver variability and accuracy, as well as the role it plays in making decisions about therapy. Patients and methods. A prospective study was designed in which 100 randomly selected angiography scans of lower extremities were examined by 3 vascular surgeons in a blind, independent manner. Arteries were classed as being patent, severely ill, occluded or not diagnosed at different levels. Agreement was expressed as κ values, and we analysed the therapeutic option proposed by each observer based on the patient record and angiography findings. Results. The percentage of arterial segments that were not identified in the preoperative arteriography (not diagnosed) was surprisingly high: 18% tibialis anterior; 21% tibialis posterior; 28% peroneal. Overall agreement was good in the aortic (κ = 0.78), iliac (κ = 0.76), femoral (κ = 0.61) and above-the-knee popliteal (κ = 0.64) segments; it was found to be moderate for the below-the-knee popliteal segment (κ = 0.50), and poor for the tibial branches (κ = 0.22). Although the 3 observers proposed identical treatment in 70% of the cases (κ = 0.65, high agreement), in 30% of cases the initial therapy plan based on the preoperative angiography did not coincide, and in 19% of cases this plan had to be modified to fit intraoperative findings. Conclusions. The important degree of interobserver variability seen in the evaluation of below-the-knee segments must be taken into account when other methods of diagnosis are compared to preoperative angiography. In this work we question its reliability, underline the need for intraoperative angiographic studies and call attention to an important bias in the interpretation of publications when attempts are made to compare this preoperative test with other non-invasive methods


Asunto(s)
Adulto , Humanos , Angiografía/métodos , Angiografía , Arteriopatías Oclusivas/fisiopatología , Arteriopatías Oclusivas/cirugía , Extremidad Inferior/lesiones , Extremidad Inferior , Enfermedades Vasculares Periféricas/diagnóstico , Enfermedades Vasculares Periféricas/cirugía , Arteriopatías Oclusivas/etiología , Toma de Decisiones
14.
Angiología ; 56(6): 587-594, nov. 2004. ilus
Artículo en Es | IBECS | ID: ibc-36827

RESUMEN

Introducción. La relación de las malformaciones vasculares con la aparición de claudicación intermitente es excepcional. Caso clínico. Presentamos el caso de un varón de 70 años, fumador, diabético y dislipémico, que acude por claudicación intermitente a corta distancia, con dolor de reposo ocasional en ambas extremidades inferiores. Tras la exploración clínica y hemodinámica, se realiza el estudio arteriográfico. La ilíaca primitiva derecha se encuentra ocluida, existen estenosis de ambas femorales profundas en sus orígenes, además de observarse obstrucción femoropoplítea bilateral. Tras la realización de un bypass iliofemoral derecho se lleva a cabo una tromboendarterectomía de femoral común y profunda izquierdas. Como hallazgo operatorio se observa un drenaje anómalo unilateral del cayado de la safena interna en la vena femoral profunda, se cruza sobre la arteria del mismo nombre, la comprime y desplaza originando cierto grado de fibrosis a su alrededor. En la arteriotomía se percibe una grave disminución del calibre de la luz arterial a este nivel, originada tanto por un aumento de la placa aterosclerótica, como por la compresión extrínseca causada por la disposición aberrante de la safena interna. Conclusión. Constituye la primera descripción de esta malformación anatómica en los grandes vasos inguinales, y se observa directamente su probable intervención sobre los factores etiopatogénicos morfológicos y hemodinámicos del proceso arteriosclerótico, y, por consiguiente, en la isquemia de la extremidad (AU)


Asunto(s)
Masculino , Persona de Mediana Edad , Humanos , Arteria Femoral/cirugía , Arteria Femoral , Arteria Femoral/patología , Vena Safena/cirugía , Vena Safena/fisiopatología , Vena Safena , Claudicación Intermitente/diagnóstico , Claudicación Intermitente , Arteriosclerosis/complicaciones , Arteriosclerosis/diagnóstico , Angiografía , Factores de Riesgo , Arteriosclerosis , Arteriosclerosis/patología , Arteriosclerosis/fisiopatología
15.
Angiología ; 56(2): 147-157, mar. 2004. ilus, tab
Artículo en Es | IBECS | ID: ibc-33159

RESUMEN

Objetivo. Analizar los resultados del tratamiento endovascular de los aneurismas de aorta abdominal, valorando las variaciones que se producen en el calibre de dichos aneurismas y la evolución de las posibles fugas durante el seguimiento a medio plazo. Pacientes y métodos. Hemos realizado este tipo de tratamiento en 110 pacientes, intervenidos desde 1999 hasta la actualidad, con un seguimiento medio de 32 meses, y exponemos nuestros resultados antes del alta y durante el seguimiento. El 98,2 por ciento de nuestros pacientes eran varones, con una edad media de 77 ñ 3,2 años (57-88). El 79 por ciento de estos pacientes cumplían los criterios de la ASA III-IV, y el resto eran mayores de 65 años siguiendo la normativa del protocolo del Instituto Carlos III. Sólo un paciente entró en nuestro protocolo, con 57 años, por deseo propio de que lo trataran de forma endovascular y no mediante cirugía abierta. Los calibres de los aneurismas tratados oscilaron entre 50 y 85 mm, con una media de 62,3 mm (ñ 5,7). No se incluyen en esta serie pacientes con aneurismas aórticos menores y con aneurismas ilíacos que precisaban tratamiento. Resultados. El tiempo medio por intervención fue de 95 minutos. A todos los pacientes se les intervino con anestesia epidural. La mortalidad fue del 0,91 por ciento (un paciente) La estancia media postoperatoria ha sido de 3,82 dias, algo elevada, ya que están incluidos los pacientes con procedimientos aortomonoilíacos y con derivación femorofemoral. Dos pacientes fallecieron por rotura aneurismática durante elprimer año, sin que existieran fugas previas; los dos pacientes se trataron de aneurismas con un calibre de 80 mm, sin la presencia de trombo en su interior, lo que debió facilitar el deslizamiento del dispositivo. Prácticamente no hemos encontrados fugas en nuestra serie (5,45 por ciento durante el seguimiento, y sí una disminución en el calibre de los aneurismas en un 82 por ciento de los pacientes. Conclusiones. Pensamos que disponemos en la actualidad de un procedimiento con una eficacia probada y seguro si hacemos una buena selección de los pacientes. Las prótesis aortoaórticas rara vez están indicadas; siempre se prefieren las aortouniilíacas y, fundamentalmente, las billíacas (AU)


Asunto(s)
Masculino , Persona de Mediana Edad , Humanos , Aneurisma de la Aorta/complicaciones , Aneurisma de la Aorta/diagnóstico , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/cirugía , Prótesis e Implantes , Factores de Riesgo , Angiografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...