Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 92(5): 053507, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243229

RESUMEN

The neutral beam injectors of the ITER experiment will rely on negative ion sources to produce 16.7 MW beams of H/D particles accelerated at 1 MeV. The prototype of these sources was built and is currently operated in the SPIDER (Source for the Production of Ions of Deuterium Extracted from a Radio frequency plasma) experiment, part of the Neutral Beam Test Facility of Consorzio RFX, Padua. In the SPIDER, the H-/D- ion source is coupled to a three grid, 100 kV acceleration system. One of the main goals of the experimentation in SPIDER is to uniformly maximize the extracted current density; to achieve this, it is important to study the density of negative ions available in the proximity of the ion acceleration system. In SPIDER, line-integrated measurements of negative ion density are performed by a cavity ring down spectroscopy diagnostic. Its principle of operation is based on the absorption of the photons of a laser beam pulse by H-/D- photo-detachment; the absorption detection is enhanced by trapping the laser pulse in an optical cavity, containing the absorbing medium (i.e., negative ions). This paper presents and discusses the CRDS diagnostic setup in the SPIDER, including the first measurements of negative ion density, correlated with the main source parameters.

2.
Rev Sci Instrum ; 91(11): 113503, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33261442

RESUMEN

Thermal Helium Beam (THB) diagnostic is widely used for measuring the electron density and temperature in the boundary region of fusion plasmas, edges, and scrape-off layers. In its standard configuration, it measures three HeI lines (667.8 nm, 706.5 nm, and 728.1 nm) and, by using a collisional-radiative model, evaluates ne and Te from the ratios of their intensities. At large neutral He density (n0 ≳ 1017 m-3), radiation re-absorption is not negligible and it has to be taken into account; it can be estimated by measuring the intensity of the fourth HeI line, λ = 501.6 nm. The original THB diagnostic of the RFX-mod experiment has been upgraded, setting up the fourth line intensity acquisition. A Czerny-Turner spectrograph separates the lines, and the old multichannel photomultiplier (PMT) detectors are replaced with the new Multi-Pixel Photon Counter (MPPC). Two 16-channel MPPC array modules allow the observation of 32 signals (4 lines × 8 spatial points). Since the MPPCs are not sensitive to the magnetic field, the whole system can be installed near the experimental device, allowing a large reduction in the optical fibers' length with a gain in the collected signal intensity. This new THB will be installed in the new experiment RFX-mod2, the upgrade of the RFX-mod device. The RFX-mod2 will operate as both reversed field pinch and tokamak, and the goal of the THB is the evaluation of the edge electron density and temperature profiles in the two magnetic configurations, in D or H plasmas. This paper describes the system, the performance of the MPPC compared with the PMTs, the alignment, and the calibration.

4.
Rev Sci Instrum ; 91(3): 033314, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32259950

RESUMEN

A movable Allison type emittance scanner is being developed to characterize the phase-space distribution of the beamlets of spectral phase interferometry for direct electric-field reconstruction, the prototype RF negative ion source of the ITER heating neutral beam injector. To test the electronics and verify the capability of the device to resolve nearby beamlets, a compact RF ion source prototype has been set up, capable of accelerating 1 mA of helium ions up to a voltage of 2 kV. A commercial 100 W RF generator creates a plasma inside a Pyrex tube, with a density between 1015 and 1016 m-3 and an electron temperature up to 15 eV. Three multi-aperture grids in accel-decel configuration extract and accelerate the ions, which are measured with a Faraday cup. We present in this paper the characterization of the ion source and its first operation, showing that it is suitable for the commissioning of the Allison scanner.

5.
Rev Sci Instrum ; 91(1): 013316, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-32012575

RESUMEN

The NIO1 (Negative Ion Optimization phase 1) source can provide continuous beam operation, which is convenient for systematic parameter and equipment studies. Even in the pure volume production regime, the source yield was found to depend on conditioning procedures. Magnetic configuration tests continued adding magnets to the existing setup; the filter field component Bx has been progressively extended to span the -12 to 5 mT range, and as a trend, source performances improved with |Bx|. The progress of camera beam diagnostics and of the quality of the volume-produced H- beam is also shown. The status, off-line results, and reliability of a first NIO1 cesium oven are discussed; other upgrades in preparation (cavity ring down spectrometer, the end calorimeter, and conceptual tests of the energy recovery system) are also listed.

6.
Rev Sci Instrum ; 87(2): 02B320, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932048

RESUMEN

Neutral Beam Injectors (NBIs), which need to be strongly optimized in the perspective of DEMO reactor, request a thorough understanding of the negative ion source used and of the multi-beamlet optics. A relatively compact radio frequency (rf) ion source, named NIO1 (Negative Ion Optimization 1), with 9 beam apertures for a total H(-) current of 130 mA, 60 kV acceleration voltage, was installed at Consorzio RFX, including a high voltage deck and an X-ray shield, to provide a test bench for source optimizations for activities in support to the ITER NBI test facility. NIO1 status and plasma experiments both with air and with hydrogen as filling gas are described. Transition from a weak plasma to an inductively coupled plasma is clearly evident for the former gas and may be triggered by rising the rf power (over 0.5 kW) at low pressure (equal or below 2 Pa). Transition in hydrogen plasma requires more rf power (over 1.5 kW).

7.
Rev Sci Instrum ; 87(2): 02B925, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932097

RESUMEN

This paper presents the results of numerical simulations and experimental tests carried out to assess the feasibility and suitability of graphite castellated tiles as beam-facing component in the diagnostic calorimeter of the negative ion source SPIDER (Source for Production of Ions of Deuterium Extracted from Radio frequency plasma). The results indicate that this concept could be a reliable, although less performing, alternative for the present design based on carbon fiber composite tiles, as it provides thermal measurements on the required spatial scale.

8.
Rev Sci Instrum ; 85(2): 02A718, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593452

RESUMEN

Operation of the thermonuclear fusion experiment ITER requires additional heating via injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction in Padova, the production of negative ions will be studied and optimised. STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) is a diagnostic used to characterise the SPIDER beam during short pulse operation (several seconds) to verify if the beam meets the ITER requirements about the maximum allowed beam non-uniformity (below ±10%). The major components of STRIKE are 16 1D-CFC (Carbon-Carbon Fibre Composite) tiles, observed at the rear side by a thermal camera. This contribution gives an overview of some tests under high energy particle flux, aimed at verifying the thermo-mechanical behaviour of several CFC prototype tiles. The tests were performed in the GLADIS facility at IPP (Max-Plank-Institut für Plasmaphysik), Garching. Dedicated linear and nonlinear simulations were carried out to interpret the experiments and a comparison of the experimental data with the simulation results is presented. The results of some morphological and structural studies on the material after exposure to the GLADIS beam are also given.

9.
Rev Sci Instrum ; 81(10): 10D715, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033908

RESUMEN

The edge of the reversed field pinch experiment RFX-mod (R=2 m, a=0.46 m) is characterized by a complex magnetic topology and strong pressure gradients. A set of fast spectroscopic diagnostics has been designed to characterize both main plasma edge parameters and turbulence, including coherent structures (blobs) and radial profiles of the thermodynamic variables. Measurements of the edge radial profiles of electron density (n(e)), temperature (T(e)), and pressure (P(e)) are obtained by a thermal helium beam diagnostic, which locally measures the ratios of the spectral lines emitted by a neutral He cloud puffed into hydrogen plasma discharges. A gas puff imaging system allows the high frequency (1 MHz bandwidth) measurement of the fluctuations of He I emissivity in the same positions. The system measures both the intermittent behavior of the edge turbulence and n(e), T(e), and P(e) profiles of the corresponding coherent structures, with a resolution down to 6 µs. The optical diagnostics are complemented by a set of triaxial magnetic coils to simultaneously characterize the edge magnetic field.

10.
Rev Sci Instrum ; 81(12): 123509, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21198025

RESUMEN

An in situ window cleaning system by laser blow-off through optical fiber has been developed on the basis of a feasibility study previously presented. The beam generated by a Q-switched Nd:YAG laser is launched in a vacuum box into a high damage threshold optical fiber through a lens. The fiber output is focused on the impurities-coated surface of a vacuum window exposed to the plasma of the RFX-mod experiment, and it is remotely controlled with an xy motion system to scan the entire surface. We first investigate the energy density threshold necessary to ablate the deposited impurity substrate on removed dirty windows: above threshold, a single laser pulse recovers ∼95% of the window transmission before its exposure to the plasma, while below it the efficiency of the cleaning process is too poor. The system so conceived was then used to clean the three collection windows of the Main Thomson scattering diagnostic on RFX-mod. We also present results obtained applying the same technique to the SiO-protected Al mirror used for the Z(eff) diagnostic: an energy threshold for efficient impurity removal without mirror damage is first identified, then ablation tests are executed and analyzed in terms of recovered reflectivity. The SIMS technique is used both with windows and mirror to study the composition of surfaces before and after the ablation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...