Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Artif Organs ; 25(10): 960-5, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12456037

RESUMEN

Long-term maintenance of viability and expression of differentiated hepatocyte function is crucial for bioartificial liver support. We developed a new bioreactor design (ALEX), associated with a new extracellular autologous hepatocyte biomatrix (Porcine Autologous Biomatrix - PBM) support. To test this new bioreactor, we compared it to a standard BAL (BioArtificial Liver) cartridge in a ex vivo model using human plasma added to bilirubin, ammonium and lidocaine. A pathology study was performed on both bioreactors. The results suggest that ALEX allows a maximal contact between the perfusing plasma and the liver cells and a proper hepatocyte support by a cell-to-matrix attachment. ALEX is a suitable cell support bioreactor, guaranteeing long-term maintenance of the metabolic activity of hepatocytes when compared to a standard BAL cartridge.


Asunto(s)
Circulación Extracorporea , Hígado Artificial , Amoníaco/sangre , Animales , Bilirrubina/sangre , Reactores Biológicos , Hepatocitos , Humanos , Lidocaína/sangre , Tiempo de Protrombina , Porcinos , Ingeniería de Tejidos
2.
JAMA ; 272(8): 607-10, 1994.
Artículo en Inglés | MEDLINE | ID: mdl-8057516

RESUMEN

OBJECTIVES: To identify the types of medical devices causing needlestick injuries among Italian health care workers, to document the device-specific injury rates and time trends for different hollow-bore needles, and to compare injury rates from these devices with those reported in the United States. DESIGN: Longitudinal survey. SETTINGS: Twelve Italian acute care public hospitals. METHODS: Data were obtained from a multihospital surveillance database on the number of total injuries reported in each device category. Hospitals provided the corresponding number of devices used annually for each needle type. MAIN OUTCOME MEASURE: Number of needlestick injuries by type of hollow-bore needle per 100,000 devices used per year. RESULTS: A total of 2524 injuries from hollow-bore needles were reported. Disposable syringes/hypodermic needles accounted for 59.3% of injuries, followed by winged steel needles (33.1%), intravenous catheter stylets (5.4%), and vacuum-tube phlebotomy needles (2.2%). Intravenous catheter stylets had the highest needlestick injury rate (15.7/100,000 devices used), and disposable syringes had the lowest needlestick injury rate (3.8/100,000). In contrast to the other devices, the injury rate from winged steel needles increased from 6.2 per 100,000 in 1990 to 13.9 per 100,000 in 1992. CONCLUSIONS: The device-specific needlestick injury rates in Italy are similar to those reported in the United States, suggesting similar exposure experience in two countries. However, in contrast to the United States, needleless intravenous access is standard practice in Italy and thus eliminates one potential risk to Italian health workers. Implementation of safer equipment, such as shielded or retracting needles, and continuing training programs are needed to further reduce the hazards that health care workers face.


Asunto(s)
Accidentes de Trabajo/estadística & datos numéricos , Personal de Salud/estadística & datos numéricos , Agujas/clasificación , Lesiones por Pinchazo de Aguja/epidemiología , Intervalos de Confianza , Diseño de Equipo , Humanos , Italia/epidemiología , Estudios Longitudinales , Agujas/estadística & datos numéricos , Oportunidad Relativa , Riesgo , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...